Total
Dia Nos of Total C.L
Discription of Bar Shape of the Bar(MM) Spacing No Length Unit Wt Total Wt (Kg)
(MM) col Nos (in mm)
(In Mtr)
Col Type C1
Col Size 250 x 375 mm
Clear Cover 40 mm
No of Col 16 Nos
5000
From Pile cap top to Plinth beam bottom 2800 mm as per site condition
h/4 = 700 mm
162
Triangular stirrup
170 170 8 100 16 16 256 840 215.04 0.395 84.95
8 150 10 16 160 840 134.40 0.395 53.10
170 170
80
Col Type C2
Col Size 250 x 450 mm
Clear Cover 40 mm
No of Col 10 Nos
Calculation
12000 a.2 16 4 10 40 0 0.00 1.580 0.00
not provided
0
12000
0
by ratio
5000
7000
Page 1 of 2
GF COLUMN
SDL A
Total
Dia Nos of Total C.L
Discription of Bar Shape of the Bar(MM) Spacing No Length Unit Wt Total Wt (Kg)
(MM) col Nos (in mm)
(In Mtr)
From Pile cap top to Plinth beam bottom 2800 mm as per site condition
h/4 = 700 mm
362
362
162
Triangular stirrup
203 203 8 100 16 10 160 972 155.52 0.395 61.44
8 150 10 10 100 972 97.20 0.395 38.40
203 203
80
Col Type C3
Col Size 250 x 300 mm
Clear Cover 40 mm
No of Col 8 Nos
Calculation
12000 a.2 16 2 8 16 0 0.00 1.580 0.00
not provided
0
12000
0
by ratio
5000
7000
From Pile cap top to Plinth beam bottom 2800 mm as per site condition
h/4 = 700 mm
162
TOTAL 610.46
Page 2 of 2
This document was created with the Win2PDF “Print to PDF” printer available at
https://www.win2pdf.com
This version of Win2PDF 10 is for evaluation and non-commercial use only.
Visit https://www.win2pdf.com/trial/ for a 30 day trial license.
This page will not be added after purchasing Win2PDF.
https://www.win2pdf.com/purchase/