You are on page 1of 14

MAN Diesel A/S

Main Engine Room Data


www.manbw.dk/ceas/erd

Main Engine

6K90ME-C6
IMO-NOx compliant

Project name
Project type
Project number
Date
Yard
Country
Made by
Department

Datos motor principal


Proyecto final LLM

Raquel Torrent

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Specified Main Engine and Ratings

Further reading: www.manbw.com/Papers/Basic_Principles_Of_Ship_Propulsion.pdf p. 20-29

Specified Main Engine and Ratings


Turbocharger/engine version
Type of propeller
Cylinder oil lubricator type
Sulphur content in fuel

high eff.t/c
Fixed pitch
Alpha ACC (power control)
3.0

Nominal Maximum Continuous Rating (NMCR)


Nominal engine power
Nominal engine speed
Mean effective pressure
Mean piston speed

(NMCR)

kW
r/min
bar
m/s

27,420
104.0
18.0
8.0

Specified MCR (SMCR)


Engine shaft power
Engine speed
Mean effective pressure
Mean piston speed

kW
r/min
bar
m/s

25,203
97.0
17.8
7.4

Matching point (Opt).


Optimising point
Engine shaft power
Engine speed

% of SMCR
kW
r/min

100.0
25,203
97.0

Normal Continuous Rating (NCR)


Service power
Engine shaft power
Engine speed

% of SMCR
kW
r/min

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

85.0
21,422
91.9

Page 2

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Ambient reference conditions


ISO Conditions
Scavenge air coolant temperature
Ambient air temperature
Barometric pressure
Exhaust gas back pressure

C
C
mbar
mmWC

25.0
25.0
1,000
300

Tropical conditions
Sea water temperature
Central water temperature
Ambient air temperature
Barometric pressure

C
C
C
mbar

32.0
36.0
45.0
1,000

Specified ambient conditions


Scavenge air coolant temperature
Ambient air temperature
Barometric pressure

C
C
mbar

10.0
10.0
1,000

Further reading: www.manbw.com/Papers/Influence_Of_Ambient_Temperature_Conditions.pdf p. 7-11

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 3

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Expected SFOC, Lube Oil Consumption, Air and Exhaust gas data
Tolerances
Reference LCV of fuel
SFOC tolerance (matching point)
Exhaust gas amount tolerance
Exhaust gas temperature tolerance

kJ/kg
%
%
C

42,700
+/- 5
+/- 5
-/+ 15

ISO ambient conditions


Specific Fuel Oil Consumption
Nominal Maximum Continuous Rating
(NMCR)
SMCR
Optimising point
NCR

g/kWh
g/kWh
g/kWh
g/kWh

171.0
170.5
170.5
167.1

Exhaust Gas Amount


SMCR
Optimising point
NCR

kg/h
kg/h
kg/h

247,700
247,700
219,200

Exhaust Gas Temperature


SMCR
Optimising point
NCR

C
C
C

241
241
230

Air consumption
SMCR
Optimising point
NCR

kg/s
kg/s
kg/s

67.6
67.6
59.9

Tropical ambient conditions


Specific Fuel Oil Consumption
SMCR
Optimising point
NCR

g/kWh
g/kWh
g/kWh

173.7
173.7
170.2

Exhaust Gas Amount


SMCR
Optimising point
NCR

kg/h
kg/h
kg/h

232,600
232,600
205,800

Exhaust Gas Temperature


SMCR
Optimising point
NCR

C
C
C

274
274
263

Air consumption
SMCR
Optimising point
NCR

kg/s
kg/s
kg/s

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

63.4
63.4
56.2

Page 4

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Specified ambient conditions


Specific Fuel Oil Consumption
SMCR
Optimising point
NCR

g/kWh
g/kWh
g/kWh

167.6
167.6
164.3

Exhaust Gas Amount


SMCR
Optimising point
NCR

kg/h
kg/h
kg/h

255,900
255,900
226,400

Exhaust Gas Temperature


SMCR
Optimising point
NCR

C
C
C

215
215
205

Air consumption
SMCR
Optimising point
NCR

kg/s

69.9
69.9
61.9

kg/24h

50.7

g/kWh

0.77
0.77
0.77

kg/s
kg/s

Consumption of Lubrication Oils


System Oil
Consumption per 24 hours

Cylinder Oil (SLOC)


SMCR
Optimising point
NCR

g/kWh
g/kWh

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 5

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Necessary Capacities of Auxiliary Machinery (SMCR)


Layout of Systems
Cooling water system
Seawater inlet temperature
Central water outlet temperature
Tropical ambient air temperature

C
C
C

Lubricating oil system


Separate hydraulic control oil system
Separate turbocharger L.O. system

Central cooling
32.0
36.0
45.0

No
No

Pumps
Fuel oil circulating pump
Flow capacity
Pump head

m/h
bar

11.0
6.0

Fuel oil supply pump


Flow capacity
Pump head

m/h
bar

6.9
4.0

Jacket water pump


Flow capacity
Pump head

m/h
bar

200.0
3.0

Central cooling water pump


Flow capacity
Pump head

m/h
bar

640.0
2.5

Seawater pump
Flow capacity
Pump head

m/h
bar

810.0
2.5

Lubricating oil pump


Flow capacity
Pump head

m/h
bar

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

600.0
4.6

Page 6

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Coolers
Scavenge air coolers
Heat dissipation
Central water flow

kW
m/h

10,630
363

Lubricating oil cooler


Heat dissipation
Lubricating oil flow
Central water flow

kW
m/h
m/h

2,280
600
277

Jacket water cooler


Heat dissipation
Jacket water flow
Central water flow

kW
m/h
m/h

3,580
200
277

Central cooler
Heat dissipation
Central water flow
Seawater flow

kW
m/h
m/h

16,490
640
810

Fuel oil preheater


Heat capacity
290
kW
The pump heads stated are for guidance only, and depend on the actual pressure drop across coolers, filters, etc.
in the systems.
Pertaining cooling water flow diagram, temperatures, viscosities and pressures for pumps and coolers, see "Engine
Project Guide".

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 7

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Starting Air System, Engine dimensions, Tanks, etc.


Starting air system, 30.0 bar g
Reversible engine
Receiver volume (12 starts)
Compressors (total)

m
m/h

2 x 11.0
660.0

Main engine dimensions


Dimensions
Length excl. tuning wheel, tanktop
Min length excl. tuning wheel, c/l
Max length incl. tuning wheel, c/ll
Cylinder distance
Width of bedplate
Distance, foot - crankshaft c/ll

mm
mm
mm
mm
mm
mm

12,447
12,502
13,147
1,602
4,286
1,699

Overhaul
Normal lift, c/l - crane hook
Crane capacity, normal lifting procedure
Double jib crane, c/l - deck beam
Crane capacity, double jib crane

mm
t
mm
t

12,800
10.0
12,375
2 x 5.00

Weight
Weight of main engine, dry
927.0
t
Weight of water and oil in engine
14.4
t
The real engine length at crankshaft centreline level (c/l) may be between the above min and max lengths, and
depends on the vibration conditions of the main engine and shaft system, i.e. on whether a vibration damper need
to be installed.
The mass can vary up to 10% depending on the design and options chosen

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 8

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Dimensions of tanks, centrifuges and aux. blowers


Fuel oil system
Marine diesel oil service tank, 4 hour
m
Fuel oil settling tanks, 2 x 12 hour
m
Fuel oil centrifuge, 98 C
l/h
Fuel oil service tank, 6 h/95 C
m
The capacity of the F.O. centrifuge(s) is for guidance only. Actual capacity should be given by the maker

20.0
2 x 60.0
7,403
30.0

Lubrication oil system


Lube oil storage tanks,(2x3 months)
Lube oil centrifuge, 95 C
Lube oil bottom (sump) tank, appr.

m
l/h
m

2 x 6.1
3,729
36.4

Cylinder oil system


Cylinder oil storage tanks
Cylinder oil service tank

m
m

2 x 56.0
4.4

Various drain tanks


Stuffing box drain tank
Scavenge air drain tank

m
m

0.30
0.40

Air cooler cleaning unit


Air cooler cleaning tank
Capacity of pump

m/h

0.60
2.00

1.25

kW

2 x 104

Jacket water
Expansion tank for jacket water

Auxiliary blower(s)
Electric motor rating of aux.blower(s)

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 9

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Tables of SFOC and Exhaust Gas Data


Part Load Data at ISO Ambient Conditions
Load

Power

Speed

SFOC

Exh. gas
amount

Exh. gas
temp.

% of SMCR
100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0

kW
25,203
23,943
22,683
21,423
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821

r/min
97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4

g/kWh
170.5
169.2
168.1
167.1
166.3
165.8
165.5
165.8
166.5
167.4
168.6
170.1
171.7
173.5

kg/h
247,700
238,300
228,800
219,200
209,300
199,100
188,500
177,500
166,000
154,100
141,700
128,800
115,400
101,700

C
240.6
235.7
232.1
229.8
228.9
229.2
230.9
233.8
238.1
243.7
250.6
258.8
267.1
273.2

Air suction temperature: 25.0 C


Cooling water temperature: 25.0 C

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 10

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Part Load Data at Tropical Ambient Conditions


Load

Power

Speed

SFOC

Exh. gas
amount

Exh. gas
temp.

% of SMCR
100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0

kW
25,203
23,943
22,683
21,423
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821

r/min
97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4

g/kWh
173.7
172.4
171.2
170.2
169.4
168.9
168.6
168.9
169.6
170.6
171.8
173.2
174.9
176.8

kg/h
232,600
223,800
214,900
205,800
196,500
187,000
177,000
166,700
155,900
144,700
133,000
120,900
108,400
95,500

C
273.5
268.6
265.0
262.7
261.7
262.1
263.7
266.7
271.0
276.6
283.5
292.0
300.7
307.2

Air suction temperature: 45.0 C


Cooling water temperature: 36.0 C

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 11

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Part Load Data at Specified Ambient Conditions


Load

Power

Speed

SFOC

Exh. gas
amount

Exh. gas
temp.

% of SMCR
100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0

kW
25,203
23,943
22,683
21,423
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821

r/min
97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4

g/kWh
167.6
166.4
165.3
164.3
163.5
163.0
162.7
163.0
163.7
164.6
165.8
167.2
168.8
170.6

kg/h
255,900
246,200
236,400
226,400
216,200
205,700
194,800
183,400
171,500
159,200
146,300
133,000
119,200
105,000

C
215.3
210.4
206.9
204.6
203.6
204.0
205.6
208.6
212.9
218.4
225.3
233.4
241.2
247.0

Air suction temperature: 10.0 C


Cooling water temperature: 10.0 C

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 12

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Tables of Cooler Heat


Engine load (% SMCR)
Engine power (kW)
Engine speed (r/min)

Scavenge air amount +/- 5% (kg/h)


Scavenge air pressure (bar abs)
Scavenge air temperature BEFORE air cooler (C)
Scavenge air temperature AFTER air cooler (C)
Scavenge air cooler heat (kW)

ISO Ambient Conditions

Air suction temperature: 25.0C

Jacket water cooler heat (kW)


Main lubrication oil heat (kW)

Cooling water temperature: 25.0C

kW

r/min

kg/h

bar (abs)

kW

kW

kW

100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0
30.0
25.0

25,203
23,943
22,683
21,422
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821
7,561
6,301

97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4
64.9
61.1

243,400
234,200
225,000
215,600
205,900
196,000
185,600
174,800
163,500
151,800
139,600
126,900
113,700
100,200
86,300
72,100

3.7
3.5
3.3
3.2
3.0
2.9
2.7
2.5
2.4
2.2
2.0
1.9
1.7
1.6
1.5
1.4

189.0
182.0
175.0
168.0
160.0
152.0
144.0
136.0
127.0
117.0
108.0
97.0
88.0
78.0
69.0
60.0

37.0
36.0
34.0
33.0
32.0
31.0
30.0
29.0
29.0
28.0
27.0
27.0
26.0
26.0
33.0
32.0

10,340
9,590
8,850
8,110
7,380
6,650
5,920
5,200
4,490
3,800
3,130
2,510
1,950
1,460
1,040
700

3,160
3,040
2,930
2,810
2,690
2,570
2,460
2,340
2,220
2,110
1,990
1,870
1,750
1,640
1,520
1,400

2,020
2,000
1,970
1,930
1,890
1,850
1,810
1,760
1,700
1,640
1,570
1,500
1,420
1,340
1,250
1,140

48.0
47.0
45.0
44.0
43.0
42.0
41.0
40.0
40.0
39.0
38.0
38.0
37.0
44.0
44.0
43.0

10,630
9,880
9,130
8,380
7,630
6,900
6,160
5,430
4,710
4,010
3,320
2,690
2,120
1,620
1,180
830

3,220
3,100
2,980
2,860
2,740
2,620
2,500
2,380
2,260
2,140
2,030
1,910
1,790
1,670
1,550
1,430

2,060
2,030
2,000
1,960
1,930
1,880
1,840
1,780
1,730
1,670
1,600
1,530
1,450
1,360
1,270
1,160

10,200
9,470
8,740
8,020
7,300
6,580
5,860
5,150
4,450
3,770
3,110
2,490
1,940
1,450
1,040
700

3,110
2,990
2,880
2,760
2,650
2,530
2,420
2,300
2,190
2,070
1,950
1,840
1,720
1,610
1,490
1,380

1,990
1,970
1,940
1,900
1,870
1,820
1,780
1,730
1,670
1,620
1,550
1,480
1,400
1,320
1,230
1,120

Tropical Ambient Conditions


100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0
30.0
25.0

25,203
23,943
22,683
21,422
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821
7,561
6,301

Air suction temperature: 45.0C

97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4
64.9
61.1

Specified Ambient Conditions


100.0
95.0
90.0
85.0
80.0
75.0
70.0
65.0
60.0
55.0
50.0
45.0
40.0
35.0
30.0
25.0

25,203
23,943
22,683
21,422
20,162
18,902
17,642
16,382
15,122
13,862
12,602
11,341
10,081
8,821
7,561
6,301

97.0
95.4
93.7
91.9
90.0
88.1
86.1
84.0
81.8
79.5
77.0
74.3
71.5
68.4
64.9
61.1

228,200
219,700
211,000
202,200
193,100
183,800
174,000
163,900
153,300
142,300
130,800
118,900
106,600
93,900
80,800
67,600

Cooling water temperature: 36.0C

3.6
3.4
3.2
3.1
2.9
2.8
2.6
2.5
2.3
2.1
2.0
1.8
1.7
1.6
1.4
1.3

Air suction temperature: 10.0C

251,700
242,200
232,700
222,900
212,900
202,600
191,900
180,700
169,000
156,900
144,200
131,100
117,500
103,500
89,200
74,500

214.0
207.0
200.0
192.0
184.0
176.0
168.0
159.0
149.0
140.0
129.0
119.0
108.0
98.0
89.0
80.0

Cooling water temperature: 10.0C

3.7
3.5
3.4
3.2
3.0
2.9
2.7
2.6
2.4
2.2
2.1
1.9
1.7
1.6
1.5
1.4

167.0
160.0
154.0
147.0
140.0
132.0
124.0
116.0
108.0
99.0
89.0
80.0
70.0
61.0
52.0
44.0

22.0
21.0
19.0
18.0
17.0
16.0
15.0
14.0
14.0
13.0
12.0
12.0
11.0
11.0
18.0
17.0

Scavenge air pressue and air cooler data for guidance only - not to be used for dimensioning of turbochargers and scavenge air coolers. See the design specification of the engine.

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 13

6K90ME-C6 with 2 x TCA77-20


SMCR: 25,203 kW at 97.0 RPM
Opt. point: 100.0 % IMO NOx compliance

Engine Room Dimensioning


www.manbw.dk/ceas/erd

Alternative Engines and Turbochargers, Further Reading


Alternative Engines
SMCR: 25,203 kW at 97.0 rpm. Optimization point: 100.0
Nominal MCR
Power

Specified MCR
RPM

Opt point

SFOC
(ISO)

Overhaul
height H1

Overhaul
height H3

Lengthmin

Width

Weight

[% SMCR]

[% SMCR]

[g/kWh]

[mm]

[mm]

[mm]

[mm]

[t]

[kW]

8K80MC-C6

28,880

104.0

85.0

100.0

168.7

11,900

11,300

13,952

4,088

926

9K80MC-C6

32,490

104.0

94.0

100.0

165.1

11,900

11,300

16,526

4,088

1,065

6K90MC-C6

27,420

104.0

85.0

100.0

170.5

12,800

12,375

12,447

4,286

986

7K90MC-C6

31,990

104.0

91.9

100.0

165.6

12,800

12,375

14,049

4,286

1,106

8K80ME-C6

28,880

104.0

85.0

100.0

168.7

11,900

11,300

13,952

4,088

870

9K80ME-C6

32,490

104.0

94.0

100.0

165.1

11,900

11,300

16,526

4,088

1,001

6K80ME-C9

27,180

104.0

90.9

100.0

170.8

12,550

11,925

10,700

4,480

760

7K80ME-C9

31,710

104.0

90.9

100.0

165.8

12,550

11,925

12,034

4,480

860

6K90ME-C6

27,420

104.0

85.0

100.0

170.5

12,800

12,375

12,447

4,286

927

31,990

104.0

91.9

100.0

165.6

12,800

12,375

14,049

4,286

1,040

7K90ME-C6

Engine room

Lowest opt
point

= selected engine

= lowest value

= highest value

Alternative Turbochargers
Central Seawater
cool. water pump flow
pump

Lub. oil cooler


heat diss.

oil flow

c.w. flow

Jacket water
Central cooler
cooler flow,
heat
diss.
c.w. flow s.w. flow
c.w.

Min. motor
rating for aux
blowers

[m/h]

[m/h]

[m/h]

[kW]

[m/h]

[m/h]

[m/h]

[kW]

[m/h]

[m/h]

[kW]

2 x TCA77-20

640

810

600

2,280

600

277

277

16,490

640

810

2 x 104.0

2 x NA70/T9

660

820

600

2,340

600

297

297

16,710

660

820

2 x 104.0

2 x TPL80-B12

650

810

600

2,330

600

287

287

16,540

650

810

2 x 104.0

2 x TPL85-B14

650

820

610

2,450

610

287

287

16,660

650

820

2 x 104.0

2 x MET71MA

650

810

610

2,310

610

287

287

16,520

650

810

2 x 104.0

2 x MET71SE II

650

810

610

2,310

610

287

287

16,520

650

810

2 x 104.0

2 x MET71SE

650

810

610

2,310

610

287

287

16,520

650

810

2 x 104.0

2 x MET83MA

650

820

610

2,370

610

287

287

16,580

650

820

2 x 104.0

2 x MET83SE II

650

820

610

2,370

610

287

287

16,580

650

820

2 x 104.0

650

820

610

2,370

610

287

287

16,580

650

820

2 x 104.0

2 x MET83SE

Lub. oil
flow

= selected turbocharger

s.w. = seawater

c.w. = central water

References and Further Reading


www.manbw.com/Papers/Basic_Principles_Of_Ship_Propulsion.pdf (Feb. 8th 2006)
Layout/load diagrams, running points, combinator curves, propeller propulsion, propeller types/dimensions, flow and operating conditions, ship types, hull
resistance/forms, load lines.

www.manbw.com/Papers/Influence_Of_Ambient_Temperature_Conditions.pdf (Mar. 16th 2006)


Influence of ambient temperature conditions on engine operation, engine room ventilation, special high/low temperature precautions, adjustable bypass
system.

www.manbw.com/Papers/Propulsion_Trends_in_Bulk_Carriers.pdf (Mar. 16th 2006)


Greater market demand for bulk carriers, double skinned hull design, sizes and classes, propulsion power demand, average bulk carriers, Handysize,
Panamax,

www.manbw.com/Papers/
Technical papers on propulsion trends in tankers/bulkers/shuttle tankers/container ships, exhaust gas boiler, emission control, LNG carrier, ME-GI
engines, Alpha ACC, engine noise, vibration aspects.

Local time CPH (GMT + 01:00): Jul 16th 2007 18:55 This report is for guidance only and can only be used in the initial stages of projects.
The final design values are always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel A/S.

Page 14

You might also like