1 2 3 4 5 6 7 8 9 10 11 12

N
nw

ne
A A

E
W

se
sw
S

PURLIN 1133

70CSx40x10x2MM 1090

439
B B
9x14MM
MOUNTING
HOLE 8 Nos.

20°

2278
1400
C C
RAFTER
70CSx40x10x2MM
7 8
22
4 0 0

439
1
MODULE-545Wp to 550Wp

D GENERAL NOTES
D
550
1. ALL DIMENSION ARE IN MM.
2. GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
PURLIN CLEAT 4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
LU60x60x5MM WASHERS.

CHECK BOX
AS FOR INFORMATION FOR
BUILT APPROVAL ONLY FABRICATION

E E

451.6
695
REVISIONS
COLUMN-
NO. DATE REMARKS DRAWN CHECKED
100CS40X10X2
00 12-03-24 --- JK SM

F 5 F
3 0

700
300

PROJECT_TITLE:
FRONT BRACING
PROVISION OF 630 kWp GRID CONNECTED
40LUx40x2MM

200
ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
±0.000 LVL BASE PLATE ±0.000 LVL
CLIENT:
NGL 250x250x6 MM NGL
BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY
75

EPC-CONTRACTOR:

MEC POWER INFRASTRUCTURE PVT. LTD.


H VIEW-A H
ANCHOR FASTNERS
20° DEGREE CONSULTANT:

RELATIVE ECO ENERGY SOLUTIONS

DRAWING_TITLE:

20° MMS-1PX6
PV MODULE TABLE
I I
DRAWING_NO:

M.1.1

SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N
nw

ne
A A

E
W

se
sw
S

1133
1090

439
B B
9x14MM
MOUNTING
HOLE 8 Nos.

2278
1400
A
C 6890.5 C

18.5(Typ.)
1133

439
439
MODULE-545Wp to 550Wp

D 945.3 2500 2500 945.3 GENERAL NOTES


1.
2.
ALL DIMENSION ARE IN MM.
GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
D
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
WASHERS.

CHECK BOX
AS FOR INFORMATION FOR
BUILT APPROVAL ONLY FABRICATION

E E
2278

1400
REVISIONS
LU40x40x2mm NO. DATE REMARKS DRAWN CHECKED

00 12-03-24 --- JK SM

F F

3460 3460
PROJECT_TITLE:

PURLIN-A PURLIN-B

439
PROVISION OF 630 kWp GRID CONNECTED
ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
CLIENT:

A BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY
1 2 3
EPC-CONTRACTOR:

TOP VIEW & GRID DETAILS MEC POWER INFRASTRUCTURE PVT. LTD.
H H
MOUNTING STRUCTURE 1PX6 TABLE
CONSULTANT:

RELATIVE ECO ENERGY SOLUTIONS

DRAWING_TITLE:

MMS-1PX6 TOP VIEW


PV MODULE TABLE
I I
DRAWING_NO:

M.1.1

SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

E
W

se
sw
S

1133
1090

439
B B
9x14MM
MOUNTING
HOLE 8 Nos.

2278
1400
C 710 6 C

58 451.6 200

439
D 40 GENERAL NOTES
1. ALL DIMENSION ARE IN MM.
MODULE-545Wp to 550Wp

D
2. GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
WASHERS.

CHECK BOX
AS FOR INFORMATION FOR
APPROVAL ONLY FABRICATION

250
100

100

BUILT

E E

REVISIONS

NO. DATE REMARKS DRAWN CHECKED


10

00 12-03-24 --- JK SM

F F
(18x28mm SLOT) (14x25mm SLOT)
COLUMN TO RAFTER HOLE COLUMN TO BRACING HOLE
PROJECT_TITLE:

PROVISION OF 630 kWp GRID CONNECTED


ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
WEB-COLUMN CLIENT:

BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY

EPC-CONTRACTOR:

MEC POWER INFRASTRUCTURE PVT. LTD.


H H
CONSULTANT:
COLUMN- 100CS40X10X2
RELATIVE ECO ENERGY SOLUTIONS

DRAWING_TITLE:

COLUMN PART DRAWING


I I
DRAWING_NO:

M.1.1

SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

E
W
1550

se
sw
S

15
50
55 1400 95 1133
1090

439
B B
9x14MM
MOUNTING

90
2 HOLE 8 Nos.
(14x25mm SLOT) (14x25mm SLOT)
CLEAT CLEAT

2278
1400
C C

439
MODULE-545Wp to 550Wp

D GENERAL NOTES
1. ALL DIMENSION ARE IN MM.
D
2. GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
WASHERS.

1550 CHECK BOX

10
55 1400 95 40 AS FOR INFORMATION FOR
BUILT APPROVAL ONLY FABRICATION

E E

70
2
40

(14x25mm SLOT) (14x25mm SLOT) REVISIONS

CLEAT CLEAT NO. DATE REMARKS DRAWN CHECKED

00 12-03-24 --- JK SM

F F
TOP FLANGE (VIEW Y-Y)

PROJECT_TITLE:

PROVISION OF 630 kWp GRID CONNECTED


ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
CLIENT:

BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY

EPC-CONTRACTOR:
1550
50
MEC POWER INFRASTRUCTURE PVT. LTD.
H 280 670 550 H

10
40 CONSULTANT:

RELATIVE ECO ENERGY SOLUTIONS

DRAWING_TITLE:

70
2 RAFTER PART DRAWING
(14x25mm SLOT)
I I
70

RAFTER BRACING (18x28mm SLOT)


RAFTER COLUMN DRAWING_NO:

M.1.1

WEB-RAFTER SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J
RAFTER 70CS40x10x2mm CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

E
W

se
sw
S
36.2 61.5 61.5 30.7
1090 1090 1090 40
1133
1090

70

439
B 2
B
9x14MM
(10x25mm SLOT TYP.) (10x25mm SLOT TYP.) (10x25mm SLOT TYP.) (10x25mm SLOT TYP.) MOUNTING
40

HOLE 8 Nos.
MODULE MODULE MODULE MODULE

2278
1400
C C
TOP FLANGE (VIEW Y-Y)

439
MODULE-545Wp to 550Wp

D GENERAL NOTES
1. ALL DIMENSION ARE IN MM.
D
2. GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
WASHERS.

Y Y CHECK BOX
3460 AS
BUILT
FOR
APPROVAL
INFORMATION
ONLY
FOR
FABRICATION

50 50 50 25
70

E 458 427 1973 427 40 E


35

35

35

70
35

35
2
35

(14x25mm SLOT TYP.) (14x25mm SLOT TYP.) (14x25mm SLOT TYP.) (14x25mm SLOT TYP.) REVISIONS
CLEAT HOLE CLEAT HOLE CLEAT HOLE CLEAT HOLE NO. DATE REMARKS DRAWN CHECKED
(TABLE-3 HOLE) (TABLE-6 HOLE) (TABLE-3 HOLE) (TABLE-6 HOLE)
00 12-03-24 --- JK SM
X X
F F

WEB-PURLIN-A
PROJECT_TITLE:

PROVISION OF 630 kWp GRID CONNECTED


ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
CLIENT:

BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY

EPC-CONTRACTOR:

MEC POWER INFRASTRUCTURE PVT. LTD.


H 3460 H
CONSULTANT:

1733 477 1250 40


RELATIVE ECO ENERGY SOLUTIONS

70
2 DRAWING_TITLE:
40

(14x25mm SLOT TYP.) (14x25mm SLOT TYP.)


SAG ANGLE HOLE SAG ANGLE HOLE PURLIN-A PART DRAWING
I (TABLE-3 HOLE) (TABLE-6 HOLE) I
DRAWING_NO:

M.1.1
PURLIN-A 70CSx40x10x2MM
BOTTAM FLANGE (VIEW X-X) SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

E
W

se
sw
30.7 61.5 61.5 36.2
S

1090 1090 1090 40 1133


1090

70

439
B 2 B
(10x25mm SLOT TYP.) (10x25mm SLOT TYP.) (10x25mm SLOT TYP.) (10x25mm SLOT TYP.) 9x14MM
40

MOUNTING
MODULE MODULE MODULE MODULE HOLE 8 Nos.

2278
1400
C TOP FLANGE (VIEW Y-Y) C

439
MODULE-545Wp to 550Wp

D GENERAL NOTES
1. ALL DIMENSION ARE IN MM.
D
2. GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
3. SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
WASHERS.
Y Y
CHECK BOX
3460 FOR INFORMATION FOR
AS
APPROVAL ONLY FABRICATION
50 50 50 BUILT

25 427 1973 427 458 40


E E

70
2

(14x25mm SLOT TYP.) (14x25mm SLOT TYP.) (14x25mm SLOT TYP.)


CLEAT HOLE CLEAT HOLE CLEAT HOLE X REVISIONS
70

X (14x25mm SLOT TYP.)


CLEAT HOLE (TABLE-3 HOLE) (TABLE-6 HOLE) (TABLE-6 HOLE) NO. DATE REMARKS DRAWN CHECKED
(TABLE-6 HOLE)
00 12-03-24 --- JK SM

F F

WEB-PURLIN-B
PROJECT_TITLE:

PROVISION OF 630 kWp GRID CONNECTED


ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
CLIENT:

BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY

EPC-CONTRACTOR:

3460 MEC POWER INFRASTRUCTURE PVT. LTD.


H H
1250 477 1733
40

40 CONSULTANT:

70
RELATIVE ECO ENERGY SOLUTIONS
2

(14x25mm SLOT TYP.) (14x25mm SLOT TYP.) DRAWING_TITLE:


SAG ANGLE HOLE SAG ANGLE HOLE
(TABLE-6 HOLE) (TABLE-3 HOLE)
PURLIN-B PART DRAWING
I I
DRAWING_NO:
PURLIN-B 70CSx40x10x2MM M.1.1
BOTTAM FLANGE (VIEW X-X)
SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

E
W

se
sw
S

1133
1090

439
B B
9x14MM
MOUNTING
HOLE 8 Nos.

2278
1400
C 1500 C
50 50
1400
40

40

439
MODULE-545Wp to 550Wp

D GENERAL NOTES
1. ALL DIMENSION ARE IN MM.
D
(14x25mm SLOT) (14x25mm SLOT) 2.
3.
GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
SAG ANGLE HOLE SAG ANGLE HOLE 4. DIMENSION OF STRUCTURE STEEL AS PER IS 811.

40 5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING


WASHERS.

CHECK BOX
AS FOR INFORMATION FOR
BUILT APPROVAL ONLY FABRICATION

SAG ANGLE LU40X40x2MM


E E

REVISIONS

NO. DATE REMARKS DRAWN CHECKED

00 12-03-24 --- JK SM

F F
700
37 37
625.3
40

40
PROJECT_TITLE:

PROVISION OF 630 kWp GRID CONNECTED


ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
G OVER BIKANER DIVISION G
CLIENT:
(14x25mm SLOT) (14x25mm SLOT)
FRONT BRACING TO FRONT BRACING TO BIKANER DIVISION-ELECTRICAL/NORTH
RAFTER HOLE RAFTER HOLE 40 WESTERN RALWAY

EPC-CONTRACTOR:

MEC POWER INFRASTRUCTURE PVT. LTD.


H H
CONSULTANT:

RELATIVE ECO ENERGY SOLUTIONS


FRONT BRACING LU40X40x2MM
DRAWING_TITLE:

FRONT,SAG ANGLE PART


DRAWING
I I
DRAWING_NO:

M.1.1

SHEET_NO. 1 OF 1 SCALE N.T.S

DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
N

nw

ne
A A

35
25 25

E
W
50 5

se
sw
S

35
1133
1090

439
B B

110

180

110
9x14MM
MOUNTING
HOLE 8 Nos.

35

35
35

2278
1400
35
C C
(14x25mm SLOT)

70
BRACING PLATE
HOLE
70

439
MODULE-545Wp to 550Wp
GENERAL NOTES
D 1. ALL DIMENSION ARE IN MM. D
STIFFNER-70x70x5mm 2.
3.
4.
GENERAL TOLERANCE FOR CLASS 'M' IN ACCORDANCE WITH ISO 2768.
SPECIFICATION OF STRUCTURE STEEL AS PER IS 2062.
DIMENSION OF STRUCTURE STEEL AS PER IS 811.
5. ONE SET OF HARDWARE INCLUDES 1 BOLT, 1NUT 2 PLAIN & 1 SPRING
BRACING PLATE 180x100x3MM WASHERS.

CHECK BOX
AS FOR INFORMATION FOR
BUILT APPROVAL ONLY FABRICATION

E E

(14x25mm SLOT) (14x25mm SLOT)

50
REVISIONS

PLATE HOLE CLEAT HOLE NO. DATE REMARKS DRAWN CHECKED


250
50

00 12-03-24 --- JK SM

F 25 25 F
5 50

25
PROJECT_TITLE:

60

60
PROVISION OF 630 kWp GRID CONNECTED

35
ROOF TOP SOLAR POWER PLANT AT 15
STATIONS OF AMRIT BHARAT SCHEME
250

250
G 150 100
OVER BIKANER DIVISION G
STIFFENER 60 CLIENT:

70x70x5mm SIDE VIEW


BIKANER DIVISION-ELECTRICAL/NORTH
WESTERN RALWAY

EPC-CONTRACTOR:

3MM FILLET 30 30
MEC POWER INFRASTRUCTURE PVT. LTD.
H WELD H
CONSULTANT:

100
50

50 150 50 RELATIVE ECO ENERGY SOLUTIONS

DRAWING_TITLE:

(14x25mm SLOT) L-CLEAT, BASE PLATE &


I 60 CLEAT HOLE
STIFFENER PLATE PART DRAWING
I
TOP VIEW SIDE VIEW DRAWING_NO:
TOP VIEW
M.1.1

SHEET_NO. 1 OF 1 SCALE N.T.S


BASE PLATE 250X250X6MM CLEAT 60x60x5MM DRAWN JK SHEET_SIZE A1

J CHECKED SM REVISION 00 J
APPROVED -------------- DATE 12-03-24

1 2 3 4 5 6 7 8 9 10 11 12