You are on page 1of 6

EDP 70

POWER PROTECTION
from 40 to 60 kVA
POWER PROTECTION

Integrated service Excellent Advanced


for total safety performance Battery Care
levels

Easy to use Maximum


information

Safety necessary
for many Customising
applications your UPS

Whatever your can guarantee high


business, it is essential reliability, maximum
for you to be able to protection, Double
count on a clean, Conversion technology,
uninterrupted power microprocessor
supply. Innovative and controlled functions
easy to use, UPS of the and diagnostics and
EDP 70 range provide advanced battery care.
the ideal answer to All at extremely low
your requirements.They running costs.
The safety necessary requirements. And when you Excellent
for many applications want to know what your UPS performance levels
is doing, just look at the
EDP 70 uses Double display, which will give you all To guarantee the reliability and
Conversion Technology, the the information you want, safety that you need, EDP 70
safest and most reliable quickly and easily.You don't uninterruptible power systems
architecture for extreme even have to worry about have a full set of innovative
power supply conditions.This testing the batteries: the UPS features to ensure extremely
offers the maximum carries out the test high performance levels: the
automatically. standard size of the neutral
wire of all UPS in this range is
1.7 times the size of the phase
wire, thus ensuring complete
Integrated service for compatibility with non-linear
RESERVE/BYPASS SUPPLY
MANUAL
MAINTENANCE
BYPASS total safety loads, even in the presence of
a high crest factor (3:1).They
ELETRONIC

AC SUPPLY
RECTIFIER INVERTER STATIC
SWITCH The high reliability of this UPS also have excellent
can be improved even further performance levels with
BATTERY

with the addition of LIFE2000, unbalanced loads.


the only remote monitoring EDP 70 performs at high levels
CRITICAL
LOAD program designed for real-time even when the power supply
troubleshooting.Your UPS quality is not constant. In
TOP SECURITY practice, this means that there
TOP RELIABILITY maintains regular contact with
TOP QUALITY POWER the Chloride Customer is a high tolerance range for
voltages and frequencies
protection against all kinds of outside rated values, and
network disturbance: from fluctuations of up to ± 20%
surges to frequency can be tolerated without
fluctuations, from momentary having to use the batteries.
transients to full black-outs.
The inverter remains in
operation at all times,
supplying the load directly and
keeping output voltage and Service Centre and, in the
frequency at constant levels, event of disturbance, warns
irrespective of the input values. the operators so that they can
A static switch and reserve intervene, often remotely and
line provide additional even before you have noticed
protection for your system. that there is a problem. At
regular intervals, a report is
transmitted to the Service
Centre with all the information
Easy to use relating to UPS performance.
This program truly allows you
Designed with the latest to delegate the care of your
technology, the UPS of the system to our experts who
EDP 70 range are compact, will take appropriate action in
light and quiet.They are also each instance.
reliable and easy to use,
working diligently and
discreetly and adapting to any
Advanced Battery Maximum Customising your
Care information UPS
We never tire of emphasising Another great advantage of There are numerous options
the importance of the EDP 70 is that it keeps you available to customise your
batteries. In the event of a constantly informed. All the EDP 70 UPS. Here are just a
power failure, the batteries information relating to tests small selection. Connectivity
provide a reserve power and check-ups performed by options include the shutdown
supply for long enough to the microprocessor is and monitoring software (Easy
automatically recorded in the Plus, EPRA and MOP UPS),
Power History and displayed in the communication kit for the
the manner which you prefer. J-BUS protocol and the
A serial port and a computer ManageUPS card. Hardware
interface allow connection to options include the galvanic
software applications, while a isolation transformer, the
description of the current harmonic filter and the remote
operating parameters can be display unit. Moreover, with the
viewed on the liquid crystal Multicom option, you can have
display in 6 different languages. up to three serial ports, while
To make it even easier, there the Multiplexer option allows
allow your computer system are further options: a remote up to four AS/400™ or
to be shut down in an display unit that can follow you equivalent systems to be
ordered manner and without anywhere, an adapter connected at the same time.
any data loss. (ManageUPS) that allows
Therefore, battery reliability monitoring via Tel Net,
and replacement costs are network and SNMP; two
among the most important graphic software options Easy
factors to be considered when Plus for local control and Easy
choosing a UPS. At Chloride Plus Remote Access for
we have always attached
primary importance to the
battery. Once a week, EDP 70
carries out a fully automatic
battery test. Further, the
battery recharge voltage is
automatically compensated remote control – for easy
according to temperature. monitoring of your installation.
These and other important Yet another option available
features mean that you can with EDP 70 is a monitoring
rely on EDP 70 to check your and control program, with an
power supply source and to exclusive function: round-the-
handle it extremely efficiently, clock shutdown service
increasing battery life by 30% software which shuts down
or more. your network when required.
As you can imagine, this all
adds up to considerable
reductions in running costs.
POWER PROTECTION

THREE-PHASE OUTPUT

TECHNICAL CHARACTERISTICS 400 500 600

Output power with cosϕ = 0.8 (kVA) 40 50 60


INPUT
Rectifier supply voltage (V) 400 ± 20% 3-phase + neutral
Reserve voltage (V) 400 ± 10% (380V, 415V selectable) 3-phase + neutral
Frequency (Hz) 50 ± 5% (60 Hz selectable)
OUTPUT
Voltage (V) 400 (380V, 415V selectable) 3-phase + neutral
Neutral 1.7 times the size of the phase wire
Voltage stability (%)
- static ±1 ±1 ±1
- due to load variation 0 - 100% ±5 ±5 ±5
Response time < 5 ms < 5 ms < 5 ms
Frequency (Hz) 50 (60 Hz selectable)
Frequency stability (%)
- with network synchronisation ± 0.75; 1.5; 3.0; 6.0; (selectable)
- with own oscillator 0,05 0,05 0,05
Harmonic distortion
- with 100% linear load < 3% < 3% < 3%
- with 100% non-linear load and crest factor 3:1 < 5% < 5% < 5%
Inverter overload 125% for 10 min.; 150% for 1 min.

GENERAL
Autonomy (minutes)* 16 12 10
Operating temperature (°C) - 10 / + 40 - 10 / + 40 - 10 / + 40
Relative humidity (without condensation at 20° C) < 90% < 90% < 90%
Colour RAL 7035 RAL 7035 RAL 7035
Noise at 1 metre (dBA) 55 62 62
AC/AC performance (%) 92,0 92,3 92,3
DC/AC performance (%) 92,8 93,3 93,3
DIMENSIONS AND WEIGHTS
Height (mm) 1400 1400 1400
Width (mm) 700 700 700
Depth (mm) 730 730 730
UPS weight without batteries (kg) 460 530 550

* Requires an additional battery cubicle 450 mm wide


AUSTRALIA ITALY THAILAND UK
Chloride Hytek Chloride Silectron Chloride Power Protection Chloride Power Protection
Unit CIA & CIB Via Fornace 30 127/25 Panjathani Tower, 20th Floor (Chloride World Headquarters)
Centrecourt Business Park 40023 Castel Guelfo (BO) Nonsee Road George Curl Way
25-27 Paul Street North Italy Chongnonsee,Yannawa Southampton
NORTH RYDE NSW 2113 Telephone: +39 0542 632 111 Bangkok 10120 Hampshire, SO18 2RY
Australia Facsimile: +39 0542 632 120 Thailand United Kingdom
Telephone: +61 2 98881266 Telephone: + 66 2 6810100 Telephone: +44 (0) 23 8061 0311
Facsimile: +61 2 9888 1966 Facsimile: +66 2 6810109 Facsimile: +44 (0) 23 8061 0852
PORTUGAL
BRAZIL Chloride Power Protection TURKEY Oneac UK
Chloride Power Protection Rua dos Tercos 574 Masterguard 18 & 20 Blacklands Way
Latin America Zona Industrial de Canelas E-5 Bostanci Koprusu Kavsagi Abingdon Business Park
Rua Arizona 1349, 6° Andar 4405 270 Canelas Vila Nova de Gaia Sebnem Sokak Nº 10, Kat: 3-4-7-8 Abingdon
Brooklyn Novo Portugal 81110 Bostanci – Istanbul Oxfordshire OX14 1DY
Sao Paulo CEP 04567-002 Telephone: +351 22 7151 210 Turkey United Kingdom
Brazil Facsimile: + 351 22 7126 337 Telephone: +90 216 464 47 00 Telephone: +44 (0) 1235 534721
Telephone: +55 11 5505 4661 Facsimile: +90 216 464 47 15 Facsimile: + 44 (0) 1235 534197
Facsimile: +55 11 5505 4832 SINGAPORE
Chloride Power Protection UAE USA
FRANCE 80 Marine Parade Road Chloride Industrial Middle-East (CIME) Oneac Corporation
Chloride Power Protection #10-08 Parkway Parade PO Box 17693 27944 North Bradley Road
1 rue Felix Potin Singapore 449269 Dubai Libertyville
ZA Les Belles Vues Telephone: +65 348 5288 United Arab Emirates Illinois 60048-9700
91290 Arpajon Facsimile: +65 348 3400 Telephone: +971 4 8818848 USA
France Facsimile: +971 4 8814518 Telephone: +1 847 816 6000
Telephone: +33 1 6926 1281 Facsimile: +1 847 680 5124
Facsimile: +33 1 6083 1816 SPAIN Chloride Power Protection Middle-Est
Chloride Boar Union House, 5th Floor Chloride Power Protection
Chloride Telecom Systems Azufre 8-10 Port Saeed Road 28430 N. Ballard Drive
ZA Les Rolandières Polígono Industrial Sur PO Box 72536 Lake Forest
35120 Dol de Bretagne 28770 Colmenar Viejo, Madrid Dubai Illinois 60045
France Spain United Arab Emirates USA
Telephone: + 33 2 99 48 2068 Telephone: +34 91 848 8400 Telephone: +971 4 2115125 Telephone: +1 800 239 2257
Facsimile: + 33 2 99 48 3394 Facsimile: +34 91 845 5132 Facsimile: +971 4 2115101 Facsimile: +1 800 833 6829

Chloride Industrial Systems


30 Avenue Montgolfier - BP 90
ISO 9001
F-69684 Chassieu Cedex
France
Telephone: +33 4 7840 1356
Facsimile: +33 4 7890 5890
Cert. No FM 10144
GERMANY This publication is for information purposes only.
Masterguard The company has a policy of continuous product
Schallershofer Str. 141 improvement and therefore reserves the right to
D-91056 Erlangen
Germany POWER PROTECTION vary any information quoted herein without prior
notice.
Telephone: +49 9131 9855 100 MKA3L0UKE70
Facsimile: +49 9131 9855 270 www.chloridepower.com EDP 70/ed.11/09-2001/UK