Professional Documents
Culture Documents
C. Generator
D. COMRESSOR
We will be replaced old 37.5 KW 2 set Air Compressor by one set new 50 KW Air compressor.
Electricity savings (160 days) 2022 = 37.5x2 -50 = 25 KW
Yearly savings 2022 = 25x24x160 =96000 KWH
Calculations :
A ) Stenter , NG save = 1865971.1- 1703790.3 =162180.8 m3
Estimted GHG reduction = 162180.8 x0.001884 =305.5 Ton CO2
Electricity save =1953120-1147653 =805465 KWH
Estimted GHG reduction = 805465 x0.000575 =463.1 Ton CO2
B ) COMPACTOR.
Estimated NG Savings = 453491.1 -294769.2 =158721.9 m3 NG
Estimted GHG reduction = 158721.9 x 0.001884 =299 Ton CO2