You are on page 1of 1

SuperServer 1019D-4C/14CN/16C-RA/DN13TP+ Quick Reference Guide

Board Layout System Features Accessing the System and installing the add-on Card
1 2 3 4 5 6 7 8 9 10 11 12 SuperServer Model Variation Table Installing the Air Shroud
PCB EDGE
SuperServer Motherboard Processor PWS model Wattage The 1019D-4C/14CN/16C-RA/DN13TP+ supports two types of PCI-E expansion card air shrouds, one for full-height cards and one for half-height cards
1019D-4C-RAN13TP+ X11SDW-4C-TP13F+ PWS-804P-1R 800W
LED2
Intel® Xeon® D-2123IT (Optional)
PRESS FIT PRESS FIT
UID 1

JUIDB1

JUSBCOM1

JBM2
MH6
JSXB1A A
1019D-4C-RDN13TP+ X11SDW-4C-TP13F+ Intel® Xeon® D-2123IT PWS-601D-1R 600W 1. Position the air shrouds in the chassis, as illustrated below. The air shroud fits just behind the fans.
JPCIE1

LED3

37 COM1
1019D-14CN-RAN13TP+ X11SDW-14CN-TP13F+ Intel® Xeon® D-2177NT PWS-804P-1R 800W 2. Slide the air shroud into the grooves just behind the fan rack. If necessary, move any cables that interfere with the air shroud placement.
USB 4/5(3.0)
1019D-14CN-RDN13TP+ X11SDW-14CN-TP13F+ Intel® Xeon® D-2177NT PWS-601D-1R 600W 3. Remove perforated tabs, if necessary, for a good fit.

JPUSB1
LAN 2/3/4/5/6/7/8/9
JIPMB1

LAN 1
IPMI_LAN MH3
36
LEDT8 LEDT5 LEDT4 LEDT1

1019D-16C-RAN13TP+ X11SDW-16C-TP13F+ Intel® Xeon® D-2183IT PWS-804P-1R 800W


A A
C A A

LEDM1
A
C C C C
JPL1
JLANLED2
A A A A
JPI2C1

LEDT2
LEDT6
1019D-16C-RDN13TP+ X11SDW-16C-TP13F+ Intel® Xeon® D-2183IT PWS-601D-1R 600W
C

JLANLED1
C C C

LEDT7

LEDT3
JSMB1 JI2C1 JI2C2 JWD1 JPME2

JTGLED2
35 LAN 12/13 LAN 10/11
13

JSDP1
34
JSDP3 J2 JMD3:M.2-P System Features
JSXB1B : PCI-E X16+X16

JBM1 PCI-E 3.0 X1


J1
14
JTGLED1
JGP1
Processors

JSDP2
JVGA1 JLANLED3
33

S-SATA0
Incorrect
JPUSB1:

COM2 USB4/5 WAKE UP

15 Intel® Xeon® D-2123IT, Intel® Xeon® D-2177NT, and Intel® Xeon® D-2183IT
1-2:ENABLE

JMD1_SRW1 2-3:DISABLE

32
JMD1_SRW2 JPL1:
LAN1
1-2:ENABLE
2-3:DISABLE

Motherboards
JI2C1/JI2C2:
JMD3_SRW1
S-SATA1
1-2:ENABLE

16
2-3:DISABLE

JVRM1
31
JWD1:WAT CH DOG

JMD1:M.2-H
1-2:RST

JMD2_SRW1
2-3:NMI
JL1

JRK1
PCI-E 3.0 X4 / I-SATA4
JPME2:
1-2:NORMAL
2-3:ME MANUFACTURING MODE

JSD1
X11SDW-4C-TP13F+, X11SDW-14CN-TP13F+, and X11SDW-16C-TP13F+

DIMMB1
DIMMA1
DIMME1
DIMMD1

17
JPG1:VGA
1-2:ENABLE

JPG1
2-3:DISABLE
BAR CODE

JPL2
JSIM1
X11SDW-4C-TP13F+ Chassis
30 REV:1.00
For 1019D-4C/14CN/16C-RDN13TP+ systems: CSE-515M-R601
JPL3 DESIGNED IN USA
18
JPV1
JPL2:
LAN 2/3/4/5
1-2:ENABLE
2-3:DISABLE
For 1019D-4C/14CN/16C-RAN13TP+ systems: CSE-515M-R804 Incorrect
Memory
JPL3:

29
LAN 6/7/8/9
1-2:ENABLE
2-3:DISABLE

JMD2:M.2-H
JPCIE3

JSXB1C
PCI-E 3.0 X2 / S-SATA4
MH5 Supports 256GB of ECC RDIMM and 512GB LRDIMM DDR4 up to 2666MHz in four DIMM slots
Chipset
JL1:
CHASSIS
INTRUSION

MH2
28 CPU
System on Chip
USB 0/1 JNVI2C1
19
JPWR1

Correct
MH7
Expansion Slots
Two PCI-E 3.0 x16 slots
JUSB1

USB 2/3
One M.2 M-Key 2280/22110 for NVMe/SATA
JUSB2

S-SATA3
JPH1 JF1 One M.2 B-Key 2242/3042 for SSD and WAN card
One M.2 E-Key 2230 for WiFi Warning: Do not tilt or
27
JF1:
PWR OH HDD PWR
RST X FF NIC2 NIC1 LED LED
ON

wiggle the riser bracket


JD1:
1-3:PWR LED
JPT1:TPM
1-2:ENABLE BT1

Input/Output
4-7:SPEAKER 2-3:DISABLE

S-SATA2 JSTBY1
MH1 20 when lifting it up.
JD1

26
S-SGPIO1
JPT1

MH4
3

Four internal SATA3 (6Gbps) ports supporting RAID 0, 1, 5, 10


JBT1
4
FAN2
FAN1

1
2 LED1
One front COM port
JTPM1

Power LED
FANB

FANA

JPW1
One front VGA port
Replacing the Fans and Power Supply
7 FAN4 FAN3

25 24 23 22 21
Network
Nine RJ45 1GbE LAN ports, four 10G SFP+ LAN ports, and one RJ45 dedicated IPMI LAN port
No. Jumper & Description Storage Drives System Fans Power Supply
1 UID: Unit Identifier Switch Two internal SATA3 2.5" drive bays The fans can adjust their speed according to the heat level sensed in the system, The power supplies are auto-switching capable. The 800W AC
2 LED2: UID LED Power which results in more efficient and quieter fan operation. Fan speed is controlled by IPMI. power supplies can operate at a 100V to 240V input range.
Each fan has its own separate tachometer. The 600W DC power supplies can operate at -48V DC input
3 LED3: Overheat/Power Fail/Fan Fail LED For 1019D-4C/14CN/16C-RDN13TP+ systems: Two 600W DC redundant power supplies
For 1019D-4C/14CN/16C-RAN13TP+ systems: Two 800W AC redundant power supplies If a fan fails, the remaining fans will ramp up to full speed, the overheat/fan fail LED on range. If replacing a power supply, the system does not need
4 JBM1: Disable IPMI Shared LAN the control panel will blink on and off, and an alarm will sound. Replace any failed fan at to be powered down.
Cooling
5 J1: M.2 SMBus Enable/Disable Five 40 x 56 mm redundant (N+1) and hot-swappable fans
your earliest convenience with the same type and model.
6 LAN6 - LAN13: 1G LAN Ports (from I350) Dimensions
7 JSDP3: Software-Defined Pins (For I350 LAN2) (WxHxD) 17.2 x 1.7 x 15.7 in (437 x 43 x 398.78 mm)
8 LAN2&LAN3/LAN4&LAN5: 10G SFP+/10G LAN
9 LAN2/IPMI LAN: 1G LAN Port (from I210) / Dedicated IPMI LAN Port Front View and Rear Features
10 COM1/USB3.1
11 JLANLED: LAN Activity LED Header AC PWS LED
12 JBM2: Disable Dedicated IPMI Shared LAN
13 JMD3: M.2 Slot E-Key 2230 (USB2.0 / PCI-E x1)
14 S-SATA0: SATA3.0 DC PWS LED
15 JMD1: M.2 Slot M-Key 2280/22110 (SATA3.0 / PCI-E x4) VGA Control Service/Asset I/O Ports PCI-E
Port Panel Tag (BMC label)
16 JRK1: RAID Key
17 JSD1: SATA DOM Power
18 JPV1: 12V 8-pin DC Power
19
Lever
JPWR1: 24-pin ATX Power Release Button
20 JSTBY1: Standby Power
21 S-SGPIO1: Serial Link General Purpose I/O Redundant and hot-swappable fans Redundant power supply BMC Password Label Caution
22 BT1: Onboard Battery
Front View Control Panel SAFETY INFORMATION
23 LED1: Power LED Pull-out tag with BMC unique
24 JBT1: CMOS Clear password underneath. IMPORTANT: See installation instructions and safety warning
1 2 3 4 5 Control Panel Features
25 JTPM1: Trusted Platform Module (TPM)/Port 80 before connecting system to power supply.
26 JPT1: TPM Enable/Disable
Item Features Description Each system comes with a unique http://www.supermicro.com/about/policies/safety_information.cfm
27 JPH1: 4-pin HDD Power 1 Informational LED Indicates one of multiple conditions default password for the ADMIN
28 JNVI2C1: Non-volatile Memory (NVMe) I²C Indicates network activity on LAN port 2 user. WARNING:
2 NIC2 LED
2 1 when flashing. This can be found on a sticker To reduce risk of electric shock/damage to equipment, disconnect
29 JMD2: M.2 Slot B-Key 2242/3042 (USB2.0/USB3.0/SATA3.0/PCI-E x2) PULL
3 NIC1 LED Indicates network activity on LAN port 1 on the motherboard and a sticker power from server by disconnecting all power cords from electrical
30 JSIM1: Nano SIM Card Slot when flashing.
underneath the service tag on outlets.
31 JVGA1: VGA 4 HDD LED Indicates hard drive activity when flashing. chassis. If any CPU socket empty, install protective plastic CPU cap.
32 JPME2: Manufacturing Mode Select Indicates power is being supplied to the If necessary, the password can
5 Power LED system power supply.
33 JWD1: Watch Dog Timer be reset by the Supermicro WARNING:
34 JI²C1/JI²C2: SMB to PCI-E Slots Enable/Disable The UID is used to switch/turn on/turn off
6 UID Button UID LED next to the PCI-E slots. IPMICFG tool. Always be sure all power supplies for this system have the same
35 JSMB1: System Management Bus Header power output. If mixed power supplies are installed, the system
The main power button is used to apply
36 LEDM1: BMC 7 Power or remove power from the power supply For more information, please visit will not operate.
37 JIPMB1: System Management Bus Header (for IPMI only) 6 7 to the server. https://www.supermicro.com/en/solutions/management-software/bmc-resources For more information go to: http://www.supermicro.com/support

http://www.supermicro.com MNL-2275-QRG Rev. 1.0