Professional Documents
Culture Documents
Event Log Feb1
Event Log Feb1
Selected Systems:
* The value for the below 3 fields 'Power, WindSpeed and Gen.Speed' will be displayed as '-' when the data is missing
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 10:14:22 AM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:22 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:22 AM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1511 Generator Over Speed Opened Safety Chain
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_916 Grid Monitor opens safety chain
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:09 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:09 AM ON EVENT_208 Converter communication fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_101 DTA or MCC Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_101 DTA or MCC Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 11:39:34 AM OFF EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 11:39:34 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 11:46:00 AM ON EVENT_276 Pitch Converter not ready axis 3
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_276 Pitch Converter not ready axis 3
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 1:03:19 PM ON EVENT_213 Battery voltage not OK axis 2
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 1:10:12 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_276 Pitch Converter not ready axis 3
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:13 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:13 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:13 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:14 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:14 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:25 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:37 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:37 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:54 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:54 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:54 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:54 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:55 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:55 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:58 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:00 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:00 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:01 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:01 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:04 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:05 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:05 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:10 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:10 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:10 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:10 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:11 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:11 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:11 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:32 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:32 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:33 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:33 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:33 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:33 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:34 PM ON EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:34 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:34 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:34 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:34 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:36 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:36 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:36 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:37 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:37 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:37 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:04 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:04:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:04:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:04:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:21 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_302 Brake pads worn warning
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_153 Generator brushes worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/13/2024 2:04:35 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 2:27:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 2:27:11 PM ON EVENT_423 At least one variable is forced in the system
HAWA28 2/13/2024 2:27:11 PM ON EVENT_328 UPS fault
HAWA28 2/13/2024 2:27:11 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 2:27:12 PM ON EVENT_001 Program start PLC
HAWA28 2/13/2024 2:27:13 PM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 2:27:14 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 2:27:19 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 2:27:19 PM OFF EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 7:44:27 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 7:44:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:38 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:47 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:48 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:57 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 7:45:08 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:17 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:18 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:18 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:27 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:28 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:28 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:38 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:38 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:48 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:48 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:46:08 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:08 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:46:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:46:18 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:24 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_302 Brake pads worn warning
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_153 Generator brushes worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 7:46:25 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:26 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:27 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:36 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 8:01:28 PM ON EVENT_423 At least one variable is forced in the system
HAWA28 2/13/2024 8:01:28 PM ON EVENT_328 UPS fault
HAWA28 2/13/2024 8:01:28 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 8:01:28 PM ON EVENT_189 Manual yaw operation
HAWA28 2/13/2024 8:01:29 PM ON EVENT_001 Program start PLC
HAWA28 2/13/2024 8:01:30 PM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 8:01:30 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 8:01:32 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 8:01:32 PM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 8:01:32 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:33 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 8:01:38 PM OFF EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 8:01:41 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
Events EVENT_104, EVENT_105, EVENT_106, EVENT_107, EVENT_112, EVENT_113, EVENT_114, EVENT_115, EVENT_141, EVENT_142, EV
Selected Systems:
* The value for the below 3 fields 'Power, WindSpeed and Gen.Speed' will be displayed as '-' when the data is missing
HAWA23 2/4/2024 11:21:20 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA23 2/4/2024 11:21:20 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA24 2/4/2024 11:21:08 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA24 2/4/2024 11:21:08 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA25 2/4/2024 1:25:00 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_009 Undervoltage
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_116 Grid voltage fault
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA25 2/4/2024 1:25:09 PM ON EVENT_157 Secondary rotor brake does not close
HAWA25 2/4/2024 1:25:14 PM OFF EVENT_213 Battery voltage not OK axis 2
HAWA25 2/4/2024 1:25:24 PM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA25 2/4/2024 1:25:24 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA25 2/4/2024 1:25:24 PM OFF EVENT_276 Pitch Converter not ready axis 3
HAWA25 2/4/2024 1:26:17 PM OFF EVENT_157 Secondary rotor brake does not close
HAWA25 2/4/2024 1:30:33 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:30:33 PM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA25 2/4/2024 1:31:19 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:31:19 PM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA25 2/4/2024 1:31:19 PM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA25 2/4/2024 1:31:19 PM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA25 2/4/2024 1:31:24 PM ON EVENT_124 Pitch Overrun 0deg
HAWA25 2/4/2024 1:31:29 PM OFF EVENT_124 Pitch Overrun 0deg
HAWA25 2/4/2024 1:36:29 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA25 2/4/2024 1:38:10 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:38:41 PM ON EVENT_006 System OK
HAWA25 2/11/2024 12:36:17 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/11/2024 12:36:17 PM OFF EVENT_006 System OK
HAWA25 2/11/2024 12:38:27 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/11/2024 12:38:27 PM ON EVENT_006 System OK
HAWA25 2/18/2024 11:36:33 AM ON EVENT_383 Uncontrol battery test active
HAWA25 2/18/2024 11:36:33 AM OFF EVENT_006 System OK
HAWA25 2/18/2024 11:38:20 AM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 11:38:20 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 11:38:21 AM ON EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA25 2/18/2024 2:32:30 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA25 2/18/2024 2:46:35 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA25 2/18/2024 2:47:00 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_009 Undervoltage
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_116 Grid voltage fault
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA26 2/4/2024 11:21:22 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA26 2/4/2024 11:21:22 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA26 2/5/2024 12:08:50 AM OFF EVENT_027 Secondary hydraulic braking time too long
HAWA27 2/4/2024 11:21:34 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA27 2/4/2024 11:21:34 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA27 2/13/2024 5:02:05 AM ON EVENT_157 Secondary rotor brake does not close
HAWA27 2/13/2024 5:03:33 AM OFF EVENT_383 Uncontrol battery test active
HAWA27 2/13/2024 5:04:16 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA27 2/13/2024 5:04:34 AM ON EVENT_006 System OK
HAWA27 2/15/2024 10:21:51 AM ON EVENT_157 Secondary rotor brake does not close
HAWA27 2/15/2024 10:21:51 AM OFF EVENT_006 System OK
HAWA27 2/15/2024 10:22:31 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA27 2/15/2024 10:22:33 AM ON EVENT_006 System OK
HAWA28 2/3/2024 6:32:33 PM ON EVENT_383 Uncontrol battery test active
HAWA28 2/3/2024 6:32:33 PM OFF EVENT_006 System OK
HAWA28 2/3/2024 6:34:39 PM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/3/2024 6:34:39 PM ON EVENT_006 System OK
HAWA28 2/4/2024 5:40:39 AM ON EVENT_1226 Grid frequency
HAWA28 2/4/2024 5:40:39 AM ON EVENT_543 Turbine Limit Protection Over Frequency
HAWA28 2/4/2024 5:40:39 AM OFF EVENT_006 System OK
HAWA28 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA28 2/4/2024 5:40:39 AM ON EVENT_116 Grid voltage fault
HAWA28 2/4/2024 5:40:39 AM ON EVENT_1202 Contactor or Breaker
HAWA28 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA28 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA28 2/4/2024 5:45:52 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA28 2/4/2024 5:45:53 AM ON EVENT_387 Communication fault pitch controller Axis 2
HAWA28 2/4/2024 5:45:53 AM ON EVENT_345 Battery drive after grid fault
HAWA28 2/4/2024 5:45:57 AM ON EVENT_577 Malfunction Triplepitch System Axis 2
HAWA28 2/4/2024 6:00:36 AM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/4/2024 11:21:10 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/4/2024 11:21:10 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/4/2024 11:21:37 AM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1511 Generator Over Speed Opened Safety Chain
HAWA28 2/11/2024 4:15:07 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/11/2024 4:15:16 PM ON EVENT_1063 Pitch Conv. DC Link voltage low axis 2
HAWA28 2/11/2024 4:16:17 PM OFF EVENT_1063 Pitch Conv. DC Link voltage low axis 2
HAWA28 2/11/2024 4:18:57 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/11/2024 4:19:00 PM OFF EVENT_009 Undervoltage
HAWA28 2/11/2024 4:19:00 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/11/2024 4:19:37 PM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1511 Generator Over Speed Opened Safety Chain
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_419 CCU reports Generator over speed
HAWA28 2/13/2024 10:14:14 AM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1511 Generator Over Speed Opened Safety Chain
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:09 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:09 AM ON EVENT_208 Converter communication fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:09 AM ON EVENT_101 DTA or MCC Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:14 AM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:17 AM OFF EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:17 AM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_101 DTA or MCC Fuse or Motor protection alarm
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_276 Pitch Converter not ready axis 3
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 1:03:19 PM ON EVENT_213 Battery voltage not OK axis 2
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 1:10:12 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_212 Battery voltage not OK axis 1
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_274 Pitch Converter not ready axis 1
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_276 Pitch Converter not ready axis 3
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:13 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:14 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:14 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:54 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:54 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:58 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:01 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:10 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:11 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:32 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:33 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:33 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:34 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:34 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:36 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:01:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:02:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:03:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:04:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 2:04:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/13/2024 2:04:35 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA28 2/13/2024 2:27:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 7:44:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:47 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:44:57 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 7:45:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:17 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:18 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:27 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:28 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:38 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:48 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:48 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:45:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:46:08 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm
HAWA28 2/13/2024 7:46:18 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA28 2/13/2024 7:47:13 PM OFF EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 8:01:28 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:28 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/14/2024 4:53:43 PM ON EVENT_1511 Generator Over Speed Opened Safety Chain
HAWA28 2/14/2024 7:52:24 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA28 2/14/2024 7:52:24 PM OFF EVENT_1504 Dta Estop Opened Safety Chain
HAWA28 2/14/2024 7:52:32 PM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain
HAWA28 2/14/2024 7:52:40 PM OFF EVENT_275 Pitch Converter not ready axis 2
HAWA29 2/4/2024 11:21:15 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA29 2/4/2024 11:21:15 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA29 2/4/2024 12:26:33 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain
HAWA29 2/4/2024 12:26:33 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA29 2/4/2024 2:17:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain
HAWA29 2/4/2024 2:17:11 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain
HAWA29 2/4/2024 2:17:11 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain
Events EVENT_104, EVENT_105, EVENT_106, EVENT_107, EVENT_112, EVENT_113, EVENT_114, EVENT_115, EVENT_141, EVENT_14
No Fault ON -4 10.5 0 No
No Fault OFF -4 10.5 0 No
Pitch Fault -6 12.0 6 No
Pitch Fault -3 10.1 25 No
Pitch Fault -3 9.9 18 No
Pitch Fault -6 6.9 0 No
e User fault -2 8.4 3 No
Test required axis Pitch Safety Critical fault -2 8.4 3 No
No Fault ON -5 8.0 0 No
No Fault OFF -5 8.0 0 No
Pitch Fault -3 8.8 19 No
Pitch Fault -3 9.0 25 No
Pitch Fault -3 6.6 7 No
Pitch Fault -3 7.2 7 No
e User fault -2 10.0 28 No
Test required axis Pitch Safety Critical fault -2 10.0 28 No
No Fault ON -2 5.0 13 No
e User fault -10 7.7 31 No
No Fault OFF -10 7.7 31 No
e User fault -9 8.2 0 No
No Fault ON -9 8.2 0 No
e User fault -13 7.7 31 No
No Fault OFF -13 7.7 31 No
e User fault -4 5.7 0 No
No Fault ON -4 5.7 0 No
e User fault -5 5.5 27 No
No Fault OFF -5 5.5 27 No
e User fault -6 4.5 0 No
No Fault ON -6 4.5 0 No
Grid Fault 87 5.1 1044 No
No Fault OFF 87 5.1 1044 No
Unused Fault -15 6.0 1057 No
Grid Fault 0 5.6 1028 No
Unused Fault 0 7.0 276 No
No Fault Fault 0 6.6 14 No
User Fault 0 4.7 10 No
t Pitch Fault 0 6.4 10 No
controller Axis 2 Misc Fault 0 6.4 10 No
tem Axis 2 Pitch Safety Critical fault 0 3.1 12 No
No Fault ON -8 11.8 0 No
No Fault OFF -8 11.8 0 No
Pitch Fault -8 10.5 0 No
Pitch Fault -3 12.7 0 No
e User fault -2 9.0 5 No
Test required axis Pitch Safety Critical fault -2 9.0 5 No
No Fault ON -6 11.8 60 No
No Fault OFF -6 11.8 60 No
Pitch Fault -5 10.8 50 No
Pitch Fault -4 11.0 47 No
Pitch Fault -5 10.1 22 No
Pitch Fault -10 10.5 17 No
e User fault -2 10.1 34 No
Test required axis Pitch Safety Critical fault -2 10.1 34 No
ned Safety Chain Multiple Safety Critical fault -10 3.1 1036 No
No Fault ON -5 7.1 0 No
e User fault -11 6.4 23 No
No Fault OFF -11 6.4 23 No
e User fault -3 6.4 0 No
No Fault ON -3 6.4 0 No
ter Unused Fault -2 6.5 29 No
No Fault OFF -2 6.5 29 No
ter Unused Fault -2 7.5 22 No
No Fault ON -7 6.0 24 No
ter Unused Fault 242 4.2 1030 No
No Fault OFF 242 4.2 1030 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Multiple Safety Critical fault -12 3.7 771 No
ned Safety Chain Multiple Safety Critical fault -12 3.7 771 No
ned Safety Chain Multiple Safety Critical fault -15 4.4 66607 No
No Fault ON -5 11.5 0 No
No Fault OFF -5 11.5 0 No
Pitch Fault -3 12.8 0 No
Pitch Fault -3 12.4 19 No
Pitch Fault -3 11.7 18 No
Pitch Fault -3 9.8 0 No
e User fault -2 7.5 24 No
Test required axis Pitch Safety Critical fault -2 7.5 24 No