System Timestamp Status Name Description

HAWA28 2/13/2024 1:38:44 AM OFF EVENT_221 External power limitation


HAWA28 2/13/2024 1:39:10 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 2:13:49 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 2:14:27 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 2:49:15 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 2:51:34 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 3:23:45 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 3:24:21 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 3:26:31 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 3:26:41 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 3:58:40 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 3:59:00 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 4:33:42 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 4:36:39 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 4:59:45 AM ON EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 4:59:45 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 4:59:45 AM ON EVENT_433 Pitch system setup test active
HAWA28 2/13/2024 5:01:25 AM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 5:01:25 AM OFF EVENT_433 Pitch system setup test active
HAWA28 2/13/2024 5:01:25 AM ON EVENT_006 System OK
HAWA28 2/13/2024 5:01:26 AM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 5:02:24 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 5:04:26 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 5:05:20 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 5:09:15 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 5:09:26 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 5:28:49 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 5:28:49 AM OFF EVENT_002 No Errors
HAWA28 2/13/2024 5:28:49 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 5:31:12 AM ON EVENT_310 Fault reset
HAWA28 2/13/2024 5:31:12 AM ON EVENT_308 Idling command
HAWA28 2/13/2024 5:31:13 AM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 5:31:13 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter

WindSCADA 11.0 SP9.0 Page 1 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 5:31:13 AM ON EVENT_002 No Errors


HAWA28 2/13/2024 5:31:31 AM ON EVENT_006 System OK
HAWA28 2/13/2024 5:31:31 AM OFF EVENT_308 Idling command
HAWA28 2/13/2024 6:19:57 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 6:21:28 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 6:54:46 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 6:56:40 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 7:29:19 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 7:30:36 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 8:03:48 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 8:06:32 AM ON EVENT_221 External power limitation
HAWA28 2/13/2024 8:38:20 AM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 8:41:47 AM OFF EVENT_058 Demand to stop by an external device
HAWA28 2/13/2024 8:41:47 AM ON EVENT_166 Normal operation
HAWA28 2/13/2024 8:41:47 AM ON EVENT_181 Spinning position
HAWA28 2/13/2024 8:41:52 AM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 8:42:49 AM ON EVENT_182 Start-up
HAWA28 2/13/2024 8:42:49 AM OFF EVENT_181 Spinning position
HAWA28 2/13/2024 8:44:46 AM ON EVENT_183 Load operation
HAWA28 2/13/2024 8:44:46 AM OFF EVENT_182 Start-up
HAWA28 2/13/2024 8:58:31 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 8:58:31 AM OFF EVENT_002 No Errors
HAWA28 2/13/2024 8:58:31 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 8:58:31 AM OFF EVENT_183 Load operation
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1205 DC Link over-voltage
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1262 IOC, Rotor Converter
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1288 Overspeed
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1253 Ground Fault, Rotor
HAWA28 2/13/2024 8:58:40 AM ON EVENT_014 Generator overspeed

HAWA28 2/13/2024 8:58:40 AM ON EVENT_335 Generator overspeed 2


HAWA28 2/13/2024 8:58:40 AM ON EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/13/2024 9:07:10 AM ON EVENT_156 Repair


HAWA28 2/13/2024 9:37:10 AM ON EVENT_273 Manual or service time excessive
HAWA28 2/13/2024 10:14:13 AM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:13 AM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1016 Pitch Communication short term fault axis 1

WindSCADA 11.0 SP9.0 Page 2 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:14:13 AM ON EVENT_118 Emergency stop nacelle or hub


HAWA28 2/13/2024 10:14:13 AM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM ON EVENT_016 Rotor Monitor Over Speed


HAWA28 2/13/2024 10:14:13 AM ON EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:14:13 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:13 AM ON EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:13 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:13 AM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 10:14:13 AM ON EVENT_308 Idling command
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM OFF EVENT_014 Generator overspeed

HAWA28 2/13/2024 10:14:13 AM OFF EVENT_335 Generator overspeed 2


HAWA28 2/13/2024 10:14:13 AM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:13 AM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:13 AM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:13 AM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:13 AM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:13 AM OFF EVENT_308 Idling command
HAWA28 2/13/2024 10:14:13 AM ON EVENT_419 CCU reports Generator over speed

HAWA28 2/13/2024 10:14:14 AM ON EVENT_047 Service switch hydraulic top cabinet


HAWA28 2/13/2024 10:14:14 AM OFF EVENT_419 CCU reports Generator over speed

HAWA28 2/13/2024 10:14:14 AM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 10:14:14 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:14 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:14 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:14 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:14 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:14 AM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 10:14:14 AM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:14 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1205 DC Link over-voltage
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1262 IOC, Rotor Converter
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1288 Overspeed
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1253 Ground Fault, Rotor
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter

WindSCADA 11.0 SP9.0 Page 3 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:14:15 AM ON EVENT_120 Pitch controller communications fault


HAWA28 2/13/2024 10:14:15 AM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:15 AM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:15 AM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:18 AM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 10:14:19 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:19 AM OFF EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:14:21 AM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:21 AM ON EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:14:21 AM ON EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:21 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 10:14:22 AM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:22 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:22 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:22 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:22 AM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:23 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:23 AM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:14:23 AM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:14:23 AM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:14:26 AM OFF EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:14:26 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 10:14:51 AM ON EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_118 Emergency stop nacelle or hub
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_016 Rotor Monitor Over Speed

WindSCADA 11.0 SP9.0 Page 4 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_177 Tower vibration


HAWA28 2/13/2024 10:14:51 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/13/2024 10:14:52 AM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 10:14:53 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 10:14:53 AM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 10:14:54 AM ON EVENT_310 Fault reset


HAWA28 2/13/2024 10:14:54 AM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 10:14:58 AM ON EVENT_344 Pitch malfunction 2 or 3 blades

HAWA28 2/13/2024 10:15:09 AM ON EVENT_087 Restart time delay


HAWA28 2/13/2024 10:15:09 AM ON EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM ON EVENT_916 Grid Monitor opens safety chain


HAWA28 2/13/2024 10:15:09 AM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 10:15:09 AM ON EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:15:09 AM ON EVENT_118 Emergency stop nacelle or hub
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM ON EVENT_016 Rotor Monitor Over Speed


HAWA28 2/13/2024 10:15:09 AM ON EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:15:09 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:15:09 AM ON EVENT_310 Fault reset
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 5 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:15:09 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_060 Yaw limit switch activated


HAWA28 2/13/2024 10:15:09 AM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_344 Pitch malfunction 2 or 3 blades

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_328 UPS fault


HAWA28 2/13/2024 10:15:09 AM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_916 Grid Monitor opens safety chain
HAWA28 2/13/2024 10:15:09 AM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:09 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:09 AM ON EVENT_208 Converter communication fault

HAWA28 2/13/2024 10:15:09 AM ON EVENT_047 Service switch hydraulic top cabinet


HAWA28 2/13/2024 10:15:09 AM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 10:15:09 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:15:09 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:09 AM ON EVENT_101 DTA or MCC Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:10 AM ON EVENT_041 Tower vibration sensor failure


HAWA28 2/13/2024 10:15:10 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:15:10 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:15:10 AM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 10:15:10 AM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 10:15:10 AM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 10:15:12 AM OFF EVENT_148 Generator fan service switch
HAWA28 2/13/2024 10:15:12 AM ON EVENT_1277 MarkStat Process
HAWA28 2/13/2024 10:15:12 AM OFF EVENT_208 Converter communication fault

HAWA28 2/13/2024 10:15:12 AM ON EVENT_328 UPS fault


HAWA28 2/13/2024 10:15:14 AM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:17 AM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 10:15:17 AM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 10:15:17 AM ON EVENT_087 Restart time delay

WindSCADA 11.0 SP9.0 Page 6 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:15:17 AM OFF EVENT_118 Emergency stop nacelle or hub


HAWA28 2/13/2024 10:15:17 AM OFF EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:17 AM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:27 AM OFF EVENT_101 DTA or MCC Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:50 AM ON EVENT_310 Fault reset


HAWA28 2/13/2024 10:15:50 AM OFF EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:15:51 AM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 10:15:51 AM OFF EVENT_1277 MarkStat Process
HAWA28 2/13/2024 10:20:17 AM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 10:21:51 AM OFF EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 10:21:51 AM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 10:21:51 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 10:23:15 AM ON EVENT_333 Grid frequency and voltage inhibit start
HAWA28 2/13/2024 10:23:15 AM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:23:15 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:23:25 AM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 10:23:25 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:23:45 AM OFF EVENT_333 Grid frequency and voltage inhibit start
HAWA28 2/13/2024 10:26:51 AM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 10:28:46 AM ON EVENT_189 Manual yaw operation
HAWA28 2/13/2024 10:28:47 AM OFF EVENT_189 Manual yaw operation
HAWA28 2/13/2024 11:17:40 AM ON EVENT_1202 Contactor or Breaker
HAWA28 2/13/2024 11:22:33 AM ON EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1218 Power Supply
HAWA28 2/13/2024 11:22:38 AM ON EVENT_063 Safety chain

WindSCADA 11.0 SP9.0 Page 7 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 11:22:38 AM ON EVENT_177 Tower vibration


HAWA28 2/13/2024 11:22:38 AM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 11:22:38 AM ON EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 11:22:38 AM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:22:38 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:22:38 AM ON EVENT_1210 HSSL / HSLA, Rotor converter


HAWA28 2/13/2024 11:22:39 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 11:36:31 AM ON EVENT_156 Repair


HAWA28 2/13/2024 11:36:31 AM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 11:36:31 AM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 11:36:31 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 11:36:31 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM ON EVENT_009 Undervoltage


HAWA28 2/13/2024 11:36:31 AM ON EVENT_423 At least one variable is forced in the system
HAWA28 2/13/2024 11:36:31 AM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 11:36:31 AM ON EVENT_328 UPS fault
HAWA28 2/13/2024 11:36:31 AM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 11:36:31 AM ON EVENT_166 Normal operation
HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:36:33 AM ON EVENT_001 Program start PLC


HAWA28 2/13/2024 11:36:34 AM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 11:36:34 AM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 11:36:34 AM ON EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 11:36:39 AM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 11:36:39 AM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 11:36:39 AM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 11:36:39 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA28 2/13/2024 11:36:49 AM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 11:38:31 AM OFF EVENT_120 Pitch controller communications fault

WindSCADA 11.0 SP9.0 Page 8 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 11:39:34 AM OFF EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 11:39:34 AM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 11:46:00 AM ON EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 11:46:00 AM ON EVENT_345 Battery drive after grid fault


HAWA28 2/13/2024 11:46:00 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 11:56:21 AM ON EVENT_171 Service key brake release


HAWA28 2/13/2024 12:00:28 PM OFF EVENT_171 Service key brake release
HAWA28 2/13/2024 12:36:50 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 12:38:07 PM ON EVENT_036 Holding speed exceeded with brakes applied
HAWA28 2/13/2024 12:38:07 PM ON EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_047 Service switch hydraulic top cabinet
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_036 Holding speed exceeded with brakes applied
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 1:03:19 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 1:03:19 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 1:03:19 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 1:03:20 PM OFF EVENT_1228 Tachometer


HAWA28 2/13/2024 1:03:21 PM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 1:03:21 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 1:03:21 PM ON EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 1:03:21 PM ON EVENT_345 Battery drive after grid fault


HAWA28 2/13/2024 1:10:12 PM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 1:10:12 PM ON EVENT_063 Safety chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_060 Yaw limit switch activated


HAWA28 2/13/2024 1:10:12 PM ON EVENT_1018 Pitch Communication short term fault axis 3

WindSCADA 11.0 SP9.0 Page 9 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 1:10:12 PM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 1:10:12 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_016 Rotor Monitor Over Speed


HAWA28 2/13/2024 1:10:12 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 1:10:13 PM ON EVENT_041 Tower vibration sensor failure


HAWA28 2/13/2024 1:10:13 PM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 1:10:13 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 1:10:13 PM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 1:10:13 PM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 1:10:13 PM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 1:10:17 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 1:10:32 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 1:10:32 PM ON EVENT_302 Brake pads worn warning
HAWA28 2/13/2024 1:11:12 PM ON EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 1:11:12 PM ON EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 1:11:12 PM ON EVENT_281 Hydraulic brake test accumulator pressure
warning
HAWA28 2/13/2024 1:20:21 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 1:20:21 PM ON EVENT_084 Gearbox oil temperature too low
HAWA28 2/13/2024 1:56:10 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 1:59:59 PM ON EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 1:59:59 PM ON EVENT_153 Generator brushes worn
HAWA28 2/13/2024 2:00:04 PM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 2:00:04 PM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 2:00:04 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 2:00:04 PM OFF EVENT_063 Safety chain

HAWA28 2/13/2024 2:00:04 PM OFF EVENT_009 Undervoltage


HAWA28 2/13/2024 2:00:04 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 2:00:10 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_345 Battery drive after grid fault

WindSCADA 11.0 SP9.0 Page 10 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_161 Overvoltage protection fuse fault


HAWA28 2/13/2024 2:00:10 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 2:00:10 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:10 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:10 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:10 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:11 PM OFF EVENT_1242 Grid Loss
HAWA28 2/13/2024 2:00:12 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:12 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:13 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:13 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:13 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:13 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:13 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:13 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:14 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:14 PM ON EVENT_060 Yaw limit switch activated

WindSCADA 11.0 SP9.0 Page 11 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:14 PM ON EVENT_161 Overvoltage protection fuse fault


HAWA28 2/13/2024 2:00:14 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:14 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:24 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:24 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:25 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:34 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:34 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:37 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 12 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:37 PM OFF EVENT_060 Yaw limit switch activated


HAWA28 2/13/2024 2:00:37 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:37 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:37 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:37 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:44 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:44 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:53 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:53 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:54 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:54 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:54 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:54 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:54 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 13 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:55 PM OFF EVENT_060 Yaw limit switch activated


HAWA28 2/13/2024 2:00:55 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:55 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:55 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:58 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:58 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:59 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:59 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:00 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:00 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:00 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:00 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_060 Yaw limit switch activated

WindSCADA 11.0 SP9.0 Page 14 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:00 PM OFF EVENT_161 Overvoltage protection fuse fault


HAWA28 2/13/2024 2:01:00 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:00 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:01 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:01 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:01 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:04 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:05 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:05 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:06 PM ON EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:01:06 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:01:07 PM OFF EVENT_035 Emergency stop downtower


HAWA28 2/13/2024 2:01:09 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:09 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:09 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:10 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:10 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:10 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:10 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:10 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure

WindSCADA 11.0 SP9.0 Page 15 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:11 PM ON EVENT_310 Fault reset


HAWA28 2/13/2024 2:01:11 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:11 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:11 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:11 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:11 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:11 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:14 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:24 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:24 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:31 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:01:32 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:32 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:32 PM ON EVENT_161 Overvoltage protection fuse fault

WindSCADA 11.0 SP9.0 Page 16 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:32 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:33 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:33 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:33 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:33 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:33 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:33 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:33 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:34 PM ON EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:34 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:34 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:34 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:34 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:34 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:35 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 17 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:35 PM OFF EVENT_060 Yaw limit switch activated


HAWA28 2/13/2024 2:01:35 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:36 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:36 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:36 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:36 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:36 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:36 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:37 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:01:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:37 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:01:37 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:37 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:44 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:44 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:54 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:54 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:01:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:56 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:02:04 PM OFF EVENT_161 Overvoltage protection fuse fault

WindSCADA 11.0 SP9.0 Page 18 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:02:04 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:14 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:25 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:35 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:45 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:45 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:55 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:55 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:02:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

WindSCADA 11.0 SP9.0 Page 19 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:02:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:05 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:05 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:15 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:15 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:15 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:25 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:25 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:35 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:35 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:45 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:45 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:45 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:55 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:03:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:55 PM ON EVENT_161 Overvoltage protection fuse fault

WindSCADA 11.0 SP9.0 Page 20 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:03:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:04:05 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:04:05 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:05 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:04:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:04:15 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 2:04:15 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:21 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_302 Brake pads worn warning
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_153 Generator brushes worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 2:04:21 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:23 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:23 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:23 PM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:04:23 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:04:23 PM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 2:04:23 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:23 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:23 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 21 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:04:24 PM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 2:04:24 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:35 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:04:35 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:04:39 PM ON EVENT_310 Fault reset


HAWA28 2/13/2024 2:04:39 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:40 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:40 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:53 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:53 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:53 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:04:53 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:04 PM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 2:05:05 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:05:05 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:06 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:05:06 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:13 PM OFF EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 2:05:13 PM OFF EVENT_281 Hydraulic brake test accumulator pressure
warning
HAWA28 2/13/2024 2:05:41 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 2:05:41 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 2:05:43 PM ON EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 2:05:43 PM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA28 2/13/2024 2:05:43 PM ON EVENT_433 Pitch system setup test active
HAWA28 2/13/2024 2:05:43 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 2:07:23 PM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 2:07:23 PM OFF EVENT_433 Pitch system setup test active
HAWA28 2/13/2024 2:07:23 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 2:07:37 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:07:53 PM ON EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 2:08:09 PM ON EVENT_258 Gearbox manual operation
HAWA28 2/13/2024 2:08:48 PM OFF EVENT_258 Gearbox manual operation
HAWA28 2/13/2024 2:08:53 PM OFF EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 2:09:06 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:09:06 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 2:09:06 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 2:09:06 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:09:07 PM OFF EVENT_310 Fault reset

WindSCADA 11.0 SP9.0 Page 22 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:09:07 PM ON EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:09:07 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:10:23 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:10:23 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 2:10:23 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 2:10:23 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:10:24 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:10:24 PM ON EVENT_290 Idling in speed control
HAWA28 2/13/2024 2:10:24 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:10:24 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:10:24 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:10:24 PM OFF EVENT_290 Idling in speed control
HAWA28 2/13/2024 2:11:02 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:13:10 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 2:13:11 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 2:13:14 PM ON EVENT_156 Repair
HAWA28 2/13/2024 2:13:20 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:13:20 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 2:13:20 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 2:13:20 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:13:21 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 2:13:21 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:13:21 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:13:27 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 2:13:28 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 2:13:37 PM ON EVENT_156 Repair
HAWA28 2/13/2024 2:14:14 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:14:14 PM OFF EVENT_084 Gearbox oil temperature too low
HAWA28 2/13/2024 2:14:17 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:14:17 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 2:14:17 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 2:14:17 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 2:14:17 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:14:18 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:14:18 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:16:11 PM OFF EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 2:17:17 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 2:18:58 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:18:59 PM OFF EVENT_310 Fault reset

WindSCADA 11.0 SP9.0 Page 23 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:18:59 PM ON EVENT_310 Fault reset


HAWA28 2/13/2024 2:19:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:19:00 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 2:19:00 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:19:31 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 2:19:32 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 2:19:32 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:19:33 PM ON EVENT_181 Spinning position
HAWA28 2/13/2024 2:19:45 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:45 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:19:45 PM OFF EVENT_181 Spinning position
HAWA28 2/13/2024 2:19:45 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:19:48 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:48 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:19:48 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:19:49 PM ON EVENT_181 Spinning position
HAWA28 2/13/2024 2:19:49 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:49 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:19:49 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:19:49 PM OFF EVENT_181 Spinning position
HAWA28 2/13/2024 2:19:59 PM ON EVENT_156 Repair
HAWA28 2/13/2024 2:20:47 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:47 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:20:47 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:20:48 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:48 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:20:48 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:20:50 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:50 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:20:50 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:20:53 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:53 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:20:53 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:27:11 PM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 2:27:11 PM ON EVENT_156 Repair
HAWA28 2/13/2024 2:27:11 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 2:27:11 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 2:27:11 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 2:27:11 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 24 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:27:11 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_035 Emergency stop downtower


HAWA28 2/13/2024 2:27:11 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_423 At least one variable is forced in the system
HAWA28 2/13/2024 2:27:11 PM ON EVENT_328 UPS fault
HAWA28 2/13/2024 2:27:11 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 2:27:12 PM ON EVENT_001 Program start PLC
HAWA28 2/13/2024 2:27:13 PM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 2:27:14 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 2:27:19 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 2:27:19 PM OFF EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM ON EVENT_310 Fault reset


HAWA28 2/13/2024 2:27:22 PM ON EVENT_002 No Errors
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 2:27:23 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 2:27:53 PM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 2:28:16 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 2:28:17 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 2:28:17 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:28:47 PM ON EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 2:29:45 PM ON EVENT_156 Repair
HAWA28 2/13/2024 2:29:47 PM OFF EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 2:31:17 PM OFF EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 2:31:17 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 2:53:31 PM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 2:53:31 PM OFF EVENT_002 No Errors
HAWA28 2/13/2024 2:53:31 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:53:31 PM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 2:53:42 PM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 2:53:42 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 2:54:01 PM ON EVENT_282 Hydraulic brake test

WindSCADA 11.0 SP9.0 Page 25 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:55:01 PM OFF EVENT_282 Hydraulic brake test


HAWA28 2/13/2024 2:59:45 PM ON EVENT_273 Manual or service time excessive
HAWA28 2/13/2024 4:37:40 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 4:37:40 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 4:37:40 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 4:37:40 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 4:37:41 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 5:49:54 PM ON EVENT_221 External power limitation
HAWA28 2/13/2024 6:01:34 PM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 6:01:34 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 6:01:39 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 6:04:52 PM ON EVENT_221 External power limitation
HAWA28 2/13/2024 6:44:36 PM OFF EVENT_221 External power limitation
HAWA28 2/13/2024 6:44:36 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 6:44:41 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 7:32:10 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 7:42:04 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 7:42:09 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:42:09 PM OFF EVENT_009 Undervoltage
HAWA28 2/13/2024 7:42:09 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 7:42:09 PM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 7:42:09 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 7:42:10 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:42:10 PM OFF EVENT_1242 Grid Loss
HAWA28 2/13/2024 7:42:10 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 7:42:27 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:42:27 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 7:42:27 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 7:42:27 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 7:42:27 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:42:51 PM ON EVENT_189 Manual yaw operation
HAWA28 2/13/2024 7:43:48 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:43:48 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 7:43:48 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 7:43:48 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 7:43:48 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:43:49 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:43:49 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:44:27 PM ON EVENT_118 Emergency stop nacelle or hub

WindSCADA 11.0 SP9.0 Page 26 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:44:27 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 7:44:28 PM OFF EVENT_087 Restart time delay


HAWA28 2/13/2024 7:44:32 PM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 7:44:32 PM OFF EVENT_189 Manual yaw operation
HAWA28 2/13/2024 7:44:32 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 7:44:32 PM ON EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 7:44:32 PM ON EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 7:44:32 PM ON EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 7:44:32 PM ON EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 7:44:32 PM ON EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 7:44:32 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 7:44:32 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 7:44:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:33 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:33 PM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:44:33 PM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 7:44:34 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 7:44:34 PM OFF EVENT_1018 Pitch Communication short term fault axis 3
HAWA28 2/13/2024 7:44:34 PM OFF EVENT_1017 Pitch Communication short term fault axis 2
HAWA28 2/13/2024 7:44:34 PM OFF EVENT_1016 Pitch Communication short term fault axis 1
HAWA28 2/13/2024 7:44:37 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:37 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:37 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:38 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:38 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:47 PM ON EVENT_153 Generator brushes worn
HAWA28 2/13/2024 7:44:47 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:47 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:47 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:48 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:48 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:52 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:44:52 PM ON EVENT_302 Brake pads worn warning

WindSCADA 11.0 SP9.0 Page 27 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:44:57 PM OFF EVENT_161 Overvoltage protection fuse fault


HAWA28 2/13/2024 7:44:57 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:57 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:44:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:07 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 7:45:08 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:08 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:17 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:17 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:17 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:18 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:18 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:18 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:27 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:27 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:27 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:28 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:28 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:28 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:32 PM ON EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:45:32 PM ON EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 7:45:32 PM ON EVENT_281 Hydraulic brake test accumulator pressure
warning
HAWA28 2/13/2024 7:45:38 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:38 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:38 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:38 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:38 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure

WindSCADA 11.0 SP9.0 Page 28 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:45:48 PM OFF EVENT_161 Overvoltage protection fuse fault


HAWA28 2/13/2024 7:45:48 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:48 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:48 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:48 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:58 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:58 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:58 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:45:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:46:08 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:46:08 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:08 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:08 PM ON EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:46:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:08 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:46:13 PM ON EVENT_189 Manual yaw operation
HAWA28 2/13/2024 7:46:18 PM OFF EVENT_161 Overvoltage protection fuse fault
HAWA28 2/13/2024 7:46:18 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:18 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:24 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_302 Brake pads worn warning
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_016 Rotor Monitor Over Speed
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_153 Generator brushes worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_060 Yaw limit switch activated
HAWA28 2/13/2024 7:46:25 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:26 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:27 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:36 PM ON EVENT_310 Fault reset

WindSCADA 11.0 SP9.0 Page 29 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:46:36 PM OFF EVENT_118 Emergency stop nacelle or hub


HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 7:46:37 PM OFF EVENT_310 Fault reset


HAWA28 2/13/2024 7:46:37 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 7:46:38 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:39 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:52 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 7:46:52 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 7:47:09 PM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 7:47:13 PM OFF EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 7:47:13 PM OFF EVENT_281 Hydraulic brake test accumulator pressure
warning
HAWA28 2/13/2024 7:49:37 PM OFF EVENT_087 Restart time delay
HAWA28 2/13/2024 8:01:28 PM ON EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 8:01:28 PM ON EVENT_156 Repair
HAWA28 2/13/2024 8:01:28 PM ON EVENT_087 Restart time delay
HAWA28 2/13/2024 8:01:28 PM ON EVENT_003 Manual Stop
HAWA28 2/13/2024 8:01:28 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:28 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 8:01:28 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 8:01:28 PM ON EVENT_035 Emergency stop downtower


HAWA28 2/13/2024 8:01:28 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 8:01:28 PM ON EVENT_423 At least one variable is forced in the system
HAWA28 2/13/2024 8:01:28 PM ON EVENT_328 UPS fault
HAWA28 2/13/2024 8:01:28 PM ON EVENT_166 Normal operation
HAWA28 2/13/2024 8:01:28 PM ON EVENT_189 Manual yaw operation
HAWA28 2/13/2024 8:01:29 PM ON EVENT_001 Program start PLC
HAWA28 2/13/2024 8:01:30 PM ON EVENT_411 Automatic start up after grid outage disabled
HAWA28 2/13/2024 8:01:30 PM OFF EVENT_166 Normal operation
HAWA28 2/13/2024 8:01:32 PM ON EVENT_310 Fault reset
HAWA28 2/13/2024 8:01:32 PM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 8:01:32 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:33 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 8:01:38 PM OFF EVENT_035 Emergency stop downtower
HAWA28 2/13/2024 8:01:41 PM ON EVENT_002 No Errors

WindSCADA 11.0 SP9.0 Page 30 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 8:01:41 PM ON EVENT_310 Fault reset


HAWA28 2/13/2024 8:01:42 PM OFF EVENT_310 Fault reset
HAWA28 2/13/2024 8:02:12 PM OFF EVENT_424 System re-initialization after grid outage
HAWA28 2/13/2024 8:04:19 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 8:04:38 PM ON EVENT_006 System OK
HAWA28 2/13/2024 8:04:38 PM OFF EVENT_003 Manual Stop
HAWA28 2/13/2024 8:04:52 PM OFF EVENT_189 Manual yaw operation
HAWA28 2/13/2024 8:05:08 PM ON EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 8:06:08 PM OFF EVENT_282 Hydraulic brake test
HAWA28 2/13/2024 8:07:38 PM OFF EVENT_411 Automatic start up after grid outage disabled

HAWA28 2/13/2024 8:07:38 PM OFF EVENT_087 Restart time delay


HAWA28 2/13/2024 8:07:38 PM ON EVENT_181 Spinning position
HAWA28 2/13/2024 8:08:38 PM ON EVENT_182 Start-up
HAWA28 2/13/2024 8:08:38 PM OFF EVENT_181 Spinning position
HAWA28 2/13/2024 8:08:38 PM ON EVENT_091 Gearbox warm up
HAWA28 2/13/2024 8:10:00 PM OFF EVENT_091 Gearbox warm up
HAWA28 2/13/2024 8:10:42 PM ON EVENT_183 Load operation
HAWA28 2/13/2024 8:10:42 PM OFF EVENT_182 Start-up
HAWA28 2/13/2024 8:12:44 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 8:12:44 PM ON EVENT_308 Idling command
HAWA28 2/13/2024 8:12:44 PM ON EVENT_147 Load shutdown
HAWA28 2/13/2024 8:12:44 PM OFF EVENT_183 Load operation
HAWA28 2/13/2024 8:12:51 PM ON EVENT_184 Shut down
HAWA28 2/13/2024 8:12:51 PM OFF EVENT_147 Load shutdown
HAWA28 2/13/2024 8:12:59 PM ON EVENT_156 Repair
HAWA28 2/13/2024 8:13:11 PM OFF EVENT_184 Shut down
HAWA28 2/13/2024 8:25:27 PM OFF EVENT_156 Repair
HAWA28 2/13/2024 8:25:27 PM OFF EVENT_308 Idling command
HAWA28 2/13/2024 8:25:27 PM ON EVENT_181 Spinning position
HAWA28 2/13/2024 8:25:28 PM ON EVENT_006 System OK
HAWA28 2/13/2024 8:26:27 PM ON EVENT_182 Start-up
HAWA28 2/13/2024 8:26:27 PM OFF EVENT_181 Spinning position
HAWA28 2/13/2024 8:28:28 PM ON EVENT_183 Load operation
HAWA28 2/13/2024 8:28:28 PM OFF EVENT_182 Start-up

WindSCADA 11.0 SP9.0 Page 31 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 11:00:43 PM ON EVENT_221 External power limitation

CCU Event details:

Events EVENT_104, EVENT_105, EVENT_106, EVENT_107, EVENT_112, EVENT_113, EVENT_114, EVENT_115, EVENT_141, EVENT_142, EV

WindSCADA 11.0 SP9.0 Page 32 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Category Event Type Power Wind Speed Gen. Speed CCU
(kW) (m/s) (Rpm) Event

No Fault Information -5 6.1 33 No


No Fault Information -5 9.4 32 No
No Fault Information -5 8.0 39 No
No Fault Information -5 5.8 29 No
No Fault Information -5 5.7 35 No
No Fault Information -5 4.5 27 No
No Fault Information -5 7.6 20 No
No Fault Information -5 6.7 24 No
No Fault Information -5 8.0 24 No
No Fault Information -3 5.0 25 No
No Fault Information -5 6.9 27 No
No Fault Information -5 6.7 29 No
No Fault Information -5 3.7 37 No
No Fault Information -2 8.9 29 No
User Information -11 6.4 23 No
No Fault Information -11 6.4 23 No
Pitch Information -11 6.4 23 No
User Information -3 6.4 0 No
Pitch Information -3 6.4 0 No
No Fault Information -3 6.4 0 No
No Fault Information -5 6.4 0 No
No Fault Information -3 6.7 20 No
No Fault Information -2 5.7 25 No
No Fault Information -2 7.5 27 No
No Fault Information -5 9.1 20 No
No Fault Information -5 7.7 22 No
Unused Fault -2 6.5 29 No
No Fault Information -2 6.5 29 No
No Fault Information -2 6.5 29 No
No Fault Information -2 8.2 22 No
User Information -2 8.2 22 No
No Fault Information -2 7.5 22 No
Unused Fault -2 7.5 22 No

WindSCADA 11.0 SP9.0 Page 33 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault Information -2 7.5 22 No
No Fault Information -7 6.0 24 No
User Information -7 6.0 24 No
No Fault Information -5 7.2 24 No
No Fault Information -6 7.1 30 No
No Fault Information -5 7.1 28 No
No Fault Information -2 6.7 31 No
No Fault Information -5 6.4 33 No
No Fault Information -5 6.1 33 No
No Fault Information -5 5.7 34 No
No Fault Information -5 6.0 37 No
No Fault Information -5 5.8 28 No
External Stop Information -2 5.8 30 No
No Fault Information -2 5.8 30 No
No Fault Information -2 5.8 30 No
No Fault Information -5 6.4 46 No
No Fault Information -6 6.4 94 No
No Fault Information -6 6.4 94 No
No Fault Information -17 5.2 1045 No
No Fault Information -17 5.2 1045 No
Unused Fault 242 4.2 1030 No
No Fault Information 242 4.2 1030 No
No Fault Information 242 4.2 1030 No
No Fault Information 242 4.2 1030 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Multiple Safety Critical fault -12 3.7 771 No

Multiple Information -12 3.7 771 No


Multiple Safety Critical fault -12 3.7 771 No

User Information -3 4.6 0 No


User Fault -5 5.5 0 No
No Fault Information -2 0.0 0 No
Multiple Fault -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 34 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
User Information -2 0.0 0 No
Multiple Safety Critical fault -2 0.0 0 No

Multiple Information -2 0.0 0 No


User Information -2 0.0 0 No
Azimuth Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
User Information -2 0.0 0 No
User Information -2 0.0 0 No
Multiple Safety Critical fault -2 0.0 0 No

Multiple Safety Critical fault -2 0.0 0 No

Multiple Safety Critical fault -2 0.0 0 No

Multiple Information -2 0.0 0 No


Azimuth Information -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
No Fault Information -2 0.0 0 No
User Information -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
User Information -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
No Fault Information -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Sensor Fault Fault -2 0.0 0 No
Azimuth Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 35 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Pitch Fault -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Grid Warning -2 0.0 0 No
No Fault Information -2 0.0 0 No
User Information -2 0.0 0 No
No Fault Information -2 3.1 0 No
User Information -2 3.1 0 No
No Fault Information -2 3.1 0 No
User Information -2 3.1 0 No
Sensor Fault Fault -2 3.1 0 No
Azimuth Fault -2 3.1 0 No
Azimuth Information -2 3.1 0 No
Pitch Fault -2 3.1 0 No
Grid Warning -2 3.1 0 No
Frequency Fault -2 3.1 0 No
Converter
Misc Fault -2 3.1 0 No
User Information -2 3.1 0 No
No Fault Information -2 3.1 0 No
Azimuth Information -2 3.1 0 No
Pitch Warning -2 3.1 0 No
Pitch Warning -2 3.1 0 No
Pitch Warning -2 3.1 0 No
Frequency Fault -2 3.1 0 No
Converter
Misc Fault -2 3.1 0 No
Sensor Fault Fault -2 3.1 0 No
Azimuth Fault -2 3.1 0 No
Pitch Fault -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
User Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
No Fault Information -6 4.3 0 No
User Information -6 4.3 0 No
User Information -6 4.3 0 No
Multiple Information -6 4.3 0 No

WindSCADA 11.0 SP9.0 Page 36 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Fault -6 4.3 0 No
Sensor Fault Fault -6 4.3 0 No
Azimuth Fault -6 4.3 0 No
Azimuth Information -6 4.3 0 No
Pitch Fault -6 4.3 0 No
Frequency Fault -6 4.3 0 No
Converter
Misc Fault -6 4.3 0 No
Multiple Safety Critical fault -6 4.3 0 No

Multiple Safety Critical fault -6 4.3 0 No

Multiple Safety Critical fault -6 4.3 0 No

Multiple Safety Critical fault -6 4.3 0 No

No Fault Information -10 4.7 0 No


Pitch Safety Critical fault -10 4.7 0 No

Pitch Safety Critical fault -10 4.7 0 No

No Fault Information -6 4.2 0 No


No Fault Information -6 4.2 0 No
Pitch Safety Critical fault -6 4.3 0 No

No Fault Information -6 4.3 0 No


Multiple Safety Critical fault -6 4.3 0 No

Grid Information -6 4.3 0 No


Grid Fault -6 4.3 0 No
Multiple Fault -6 4.3 0 No
Pitch Fault -6 4.3 0 No
No Fault Information -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
User Information -6 4.3 0 No
Multiple Safety Critical fault -6 4.3 0 No

Multiple Information -6 4.3 0 No


User Information -6 4.3 0 No
Azimuth Information -6 4.3 0 No
No Fault Information -6 4.3 0 No
Multiple Safety Critical fault -6 4.3 0 No

WindSCADA 11.0 SP9.0 Page 37 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Safety Critical fault -6 4.3 0 No

Azimuth Information -6 4.3 0 No


Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Safety Critical fault -6 4.3 0 No

Multiple Warning -6 4.3 0 No


Pitch Safety Critical fault -6 4.3 0 No

Pitch Safety Critical fault -6 4.3 0 No

Grid Information -6 4.3 0 No


Pitch Fault -6 4.3 0 No
Grid Fault -6 4.3 0 No
Grid Fault -6 4.3 0 No
Frequency Fault -6 4.3 0 No
Converter
User Information -6 4.3 0 No
No Fault Information -6 4.3 0 No
Azimuth Information -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Pitch Warning -6 4.3 0 No
Frequency Fault -6 4.3 0 No
Converter
Frequency Fault -6 4.3 0 No
Converter
Sensor Fault Fault - - - No
Azimuth Fault - - - No
Pitch Fault - - - No
Pitch Warning - - - No
Pitch Warning - - - No
Pitch Warning - - - No
User Information - - - No
Unused Fault - - - No
Frequency Fault - - - No
Converter
Multiple Warning - - - No
Grid Fault -3 3.4 0 No
Grid Information -3 3.3 0 No
Misc Information -3 3.3 0 No
No Fault Information -3 3.3 0 No

WindSCADA 11.0 SP9.0 Page 38 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
User Information -3 3.3 0 No
Grid Fault -3 3.3 0 No
Grid Fault -3 3.3 0 No
Pitch Fault -7 4.3 0 No
Frequency Fault -7 4.3 0 No
Converter
Frequency Fault -7 4.3 0 No
Converter
No Fault Information -7 2.7 0 No
User Information -7 2.7 0 No
Multiple Information -7 2.7 0 No
Multiple Fault -7 2.7 0 No
Sensor Fault Fault -7 2.7 0 No
Azimuth Fault -7 2.7 0 No
Azimuth Information -7 2.7 0 No
Multiple Safety Critical fault -7 2.7 0 No

Multiple Safety Critical fault -7 2.7 0 No

Multiple Safety Critical fault -7 2.7 0 No

Multiple Safety Critical fault -7 2.7 0 No

No Fault Information -23 3.2 0 No


Unused Fault -23 3.2 0 No
Misc Information -7 4.3 0 No
Grid Information -4 3.3 0 No
Misc Information -4 3.3 0 No
No Fault Information -4 3.3 0 No
Grid Information 0 4.6 0 No
Grid Fault 0 4.6 0 No
Grid Fault 0 4.6 0 No
Unused Fault 0 2.9 0 No
Grid Fault 0 2.9 0 No
Grid Information 0 4.3 0 No
Misc Information 0 5.0 0 No
User Information 0 4.5 0 No
User Information 0 6.1 0 No
Unused Fault 0 3.3 0 No
User Information 0 1.4 10 No
Unused Fault 0 5.1 10 No
Multiple Safety Critical fault 0 5.1 10 No

WindSCADA 11.0 SP9.0 Page 39 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Fault 0 5.1 10 No
Pitch Warning 0 5.1 10 No
Pitch Warning 0 5.1 10 No
Pitch Warning 0 5.1 10 No
Multiple Information 0 5.1 10 No
Azimuth Information 0 5.1 10 No
Unused Fault 0 5.1 10 No
Multiple Safety Critical fault 0 5.1 10 No

Multiple Safety Critical fault 0 5.1 10 No

Unused Fault 0 5.1 10 No


Frequency Fault 0 0.0 10 No
Converter
User Information 0 3.7 0 No
No Fault Information 0 3.7 0 No
User Information 0 3.7 0 No
Pitch Fault 0 3.7 0 No
Multiple Safety Critical fault 0 3.7 0 No

Multiple Safety Critical fault 0 3.7 0 No

Grid Fault 0 3.7 0 No


Misc Information 0 3.7 0 No
Grid Fault 0 3.7 0 No
Multiple Warning 0 3.7 0 No
Unused Fault 0 3.7 0 No
No Fault Information 0 3.7 0 No
Multiple Safety Critical fault 0 3.7 0 No

Multiple Safety Critical fault 0 3.7 0 No

Misc Fault 0 3.6 0 No


Grid Information 0 3.4 0 No
No Fault Information 0 3.4 0 No
User Information 0 3.4 0 No
Pitch Safety Critical fault 0 3.6 0 No

Pitch Safety Critical fault 0 3.6 0 No

Pitch Safety Critical fault 0 3.6 0 No

Pitch Safety Critical fault 0 3.6 0 No

Misc Fault 0 5.0 0 No


Pitch Fault 0 2.9 0 No

WindSCADA 11.0 SP9.0 Page 40 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Information 0 4.7 0 No
No Fault Information 0 4.7 0 No
Pitch Safety Critical fault 0 3.1 0 No

Pitch Fault 0 3.1 0 No


Pitch Safety Critical fault 0 3.1 0 No

User Information 0 6.1 0 No


User Information 0 4.2 0 No
Unused Fault 0 7.5 4 No
Brake Information 0 6.0 28 No
Multiple Safety Critical fault 0 6.0 28 No

No Fault Information 0 6.4 0 No


User Information 0 6.4 0 No
Brake Information 0 6.4 0 No
Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Multiple Safety Critical fault 0 6.4 0 No

Pitch Fault 0 6.4 0 No


No Fault Information 0 6.4 0 No
Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Pitch Safety Critical fault 0 6.4 0 No

Unused Fault 0 5.1 0 No


Pitch Safety Critical fault 0 5.6 0 No

Pitch Safety Critical fault 0 5.6 0 No

Pitch Safety Critical fault 0 5.6 0 No

Pitch Fault 0 5.6 0 No


Multiple Fault 0 4.3 0 No
Multiple Safety Critical fault 0 4.3 0 No

Azimuth Information 0 4.3 0 No


Pitch Warning 0 4.3 0 No

WindSCADA 11.0 SP9.0 Page 41 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Pitch Warning 0 4.3 0 No
Pitch Warning 0 4.3 0 No
Multiple Safety Critical fault 0 4.3 0 No

Multiple Information 0 4.3 0 No


Multiple Safety Critical fault 0 4.3 0 No

Frequency Fault 0 4.3 0 No


Converter
Sensor Fault Fault 0 0.0 0 No
Azimuth Fault 0 0.0 0 No
Pitch Fault 0 0.0 0 No
Pitch Warning 0 0.0 0 No
Pitch Warning 0 0.0 0 No
Pitch Warning 0 0.0 0 No
Grid Warning 0 0.0 0 No
Brake Fault 0 0.0 0 No
Brake Warning 0 0.0 0 No
Gearbox Fault 0 0.0 0 No
Brake Fault 0 0.0 0 No
Brake Warning 0 0.0 0 No
Misc Fault 0 0.0 0 No
Gearbox Information 0 0.0 0 No
Pitch Fault 0 0.0 0 No
Misc Fault -3 0.0 0 No
Generator Warning -3 0.0 0 No
Grid Information -2 0.0 0 No
Misc Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
Multiple Safety Critical fault -2 0.0 0 No

Grid Fault -2 0.0 0 No


Grid Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Brake Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Pitch Safety Critical fault -2 0.0 0 No

Pitch Safety Critical fault -2 0.0 0 No

Pitch Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 42 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Pitch Safety Critical fault -2 0.0 0 No

Grid Warning -2 0.0 0 No


Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Pitch Safety Critical fault -2 0.0 0 No

Pitch Safety Critical fault -2 0.0 0 No

Pitch Safety Critical fault -2 0.0 0 No

No Fault Information -2 0.0 0 No


Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 43 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 44 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 45 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 46 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
User Information -2 0.0 0 No
Multiple Safety Critical fault -2 0.0 0 No

User Information -2 0.0 0 No


No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 47 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Brake Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Brake Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 48 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
User Information -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
User Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 49 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Misc Fault -2 0.0 0 No
Azimuth Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Brake Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 50 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter

WindSCADA 11.0 SP9.0 Page 51 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 52 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -3 0.0 0 No
Frequency Fault -3 0.0 0 No
Converter
Misc Fault -3 0.0 0 No
Grid Warning -3 0.0 0 No
Frequency Fault -3 0.0 0 No
Converter
Misc Fault -3 0.0 0 No
Grid Warning -8 4.8 0 No
Frequency Fault -8 4.8 0 No
Converter
Misc Fault -8 4.8 0 No
No Fault Information -9 6.2 0 No
Brake Fault -9 6.2 0 No
Brake Warning -9 6.2 0 No
Multiple Information -9 6.2 0 No
Generator Warning -9 6.2 0 No
Misc Fault -9 6.2 0 No
Multiple Fault -9 6.2 0 No
Sensor Fault Fault -9 6.2 0 No
Gearbox Fault -9 6.2 0 No
Azimuth Fault -9 6.2 0 No
Azimuth Information -9 6.2 0 No
Multiple Safety Critical fault -9 6.2 0 No

Multiple Safety Critical fault -9 6.2 0 No

Multiple Safety Critical fault -9 6.2 0 No

No Fault Information -9 6.2 0 No


Misc Fault -9 6.2 0 No
No Fault Information -7 6.9 0 No
Misc Fault -7 6.9 0 No
Pitch Safety Critical fault -7 6.9 0 No

Pitch Safety Critical fault -7 6.9 0 No

No Fault Information -7 6.9 0 No


Misc Fault -7 6.9 0 No
No Fault Information -7 6.9 0 No
Misc Fault -7 6.9 0 No

WindSCADA 11.0 SP9.0 Page 53 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault Information -8 7.2 0 No
Misc Fault -8 7.2 0 No
Pitch Safety Critical fault -8 4.5 0 No

Pitch Safety Critical fault -8 4.5 0 No

No Fault Information -7 3.4 0 No


Misc Fault -7 3.4 0 No
No Fault Information -7 4.0 0 No
Misc Fault -7 4.0 0 No
No Fault Information -7 3.2 0 No
Misc Fault -7 3.2 0 No
No Fault Information -7 3.2 0 No
Misc Fault -7 3.2 0 No
Misc Information -7 5.1 0 No
No Fault Information -7 5.1 0 No
Misc Fault -7 5.1 0 No
No Fault Information -7 4.8 0 No
Misc Fault -7 4.8 0 No
Brake Fault -7 6.4 0 No
Brake Warning -7 6.4 0 No
User Information -6 5.0 0 No
User Information -6 5.0 0 No
User Information -6 7.1 0 No
Pitch Safety Critical fault -6 7.1 0 No

Pitch Information -6 7.1 0 No


No Fault Information -6 7.1 0 No
User Information -7 6.1 0 No
Pitch Information -7 6.1 0 No
No Fault Information -7 6.1 0 No
Unused Fault -7 5.5 0 No
Brake Information -7 7.0 0 No
User Information -7 6.9 0 No
User Information -10 5.7 0 No
Brake Information -11 5.6 0 No
No Fault Information -7 6.7 3 No
User Information -7 6.7 3 No
User Information -7 6.7 3 No
Misc Fault -7 6.7 3 No
No Fault Information -7 7.1 4 No

WindSCADA 11.0 SP9.0 Page 54 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Misc Fault -7 7.1 4 No
Unused Fault -7 7.1 4 No
No Fault Information -2 5.7 0 No
User Information -2 5.7 0 No
User Information -2 5.7 0 No
Misc Fault -2 5.7 0 No
No Fault Information -2 5.7 0 No
No Fault Information -2 5.7 0 No
No Fault Information -2 5.7 0 No
Misc Fault -2 5.7 0 No
No Fault Information -2 5.7 0 No
No Fault Information -2 5.7 0 No
Unused Fault -2 7.0 4 No
User Information -2 6.4 19 No
User Information -2 7.1 18 No
User Information -2 3.3 15 No
No Fault Information -2 4.8 10 No
User Information -2 4.8 10 No
User Information -2 4.8 10 No
Misc Fault -2 4.8 10 No
User Information -3 5.8 1 No
No Fault Information -3 5.8 1 No
Misc Fault -3 5.8 1 No
User Information -3 8.1 0 No
User Information -3 7.7 0 No
User Information -2 4.8 0 No
Misc Fault -2 6.0 10 No
Gearbox Information -2 6.0 10 No
No Fault Information -2 5.7 10 No
User Information -2 5.7 10 No
User Information -2 5.7 10 No
User Information -2 5.7 10 No
No Fault Information -2 5.7 10 No
Unused Fault -3 4.0 0 No
No Fault Information -3 4.0 0 No
Grid Information -2 7.5 0 No
No Fault Information -2 6.0 0 No
No Fault Information -2 3.4 0 No
No Fault Information -2 4.5 0 No

WindSCADA 11.0 SP9.0 Page 55 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault Information -2 4.5 0 No
No Fault Information -2 4.8 0 No
No Fault Information -2 4.8 0 No
No Fault Information -2 4.8 0 No
User Information -2 3.6 0 No
User Information -2 3.6 0 No
No Fault Information -2 3.6 0 No
No Fault Information -8 4.7 0 No
Unused Fault -3 6.2 13 No
No Fault Information -3 6.2 13 No
No Fault Information -3 6.2 13 No
No Fault Information -3 6.2 13 No
Unused Fault -10 5.3 15 No
No Fault Information -10 5.3 15 No
No Fault Information -10 5.3 15 No
No Fault Information -2 4.8 20 No
Unused Fault -2 4.8 20 No
No Fault Information -2 4.8 20 No
No Fault Information -2 4.8 20 No
No Fault Information -2 4.8 20 No
User Information -3 6.7 6 No
Unused Fault -3 5.3 5 No
No Fault Information -3 5.3 5 No
No Fault Information -3 5.3 5 No
Unused Fault -3 5.3 5 No
No Fault Information -3 5.3 5 No
No Fault Information -3 5.3 5 No
Unused Fault -3 5.2 9 No
No Fault Information -3 5.2 9 No
No Fault Information -3 5.2 9 No
Unused Fault -15 5.5 16 No
No Fault Information -15 5.5 16 No
No Fault Information -15 5.5 16 No
Misc Information -8 8.6 0 No
User Information -8 8.6 0 No
No Fault Information -8 8.6 0 No
User Information -8 8.6 0 No
Pitch Fault -8 8.6 0 No
Multiple Safety Critical fault -8 8.6 0 No

WindSCADA 11.0 SP9.0 Page 56 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Safety Critical fault -8 8.6 0 No

User Information -8 8.6 0 No


Multiple Safety Critical fault -8 8.6 0 No

Multiple Safety Critical fault -8 8.6 0 No

Misc Information -8 8.6 0 No


Multiple Warning -8 8.6 0 No
No Fault Information -8 8.6 0 No
Misc Fault -6 7.7 0 No
Grid Information -6 6.9 0 No
No Fault Information -6 6.7 0 No
Pitch Fault -6 5.3 0 No
User Information -6 5.3 0 No
Multiple Safety Critical fault -7 5.0 0 No

Multiple Safety Critical fault -7 5.0 0 No

Multiple Safety Critical fault -7 5.0 0 No

Multiple Safety Critical fault -7 5.0 0 No

No Fault Information -7 5.0 0 No


No Fault Information -7 5.0 0 No
Misc Fault -7 5.0 0 No
No Fault Information -15 5.5 0 No
Misc Information -5 6.2 0 No
User Information -5 6.9 0 No
User Information -5 5.6 0 No
No Fault Information -5 5.6 0 No
Brake Information -5 4.7 0 No
User Information -5 6.1 0 No
Brake Information -5 6.6 1 No
Grid Information -5 4.8 1 No
No Fault Information -5 4.8 1 No
Grid Fault -1 5.0 17 No
No Fault Information -1 5.0 17 No
No Fault Information -1 5.0 17 No
Grid Fault -1 5.0 17 No
Unused Fault 0 5.7 10 No
Grid Fault 0 5.7 10 No
Brake Information 0 5.6 10 No

WindSCADA 11.0 SP9.0 Page 57 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Brake Information 0 6.0 11 No
User Fault 0 5.6 10 No
No Fault Information 0 8.8 0 No
User Information 0 8.8 0 No
User Information 0 8.8 0 No
User Information 0 8.8 0 No
No Fault Information 0 8.2 0 No
No Fault Information 0 8.5 0 No
No Fault Information 0 6.1 0 No
No Fault Information 0 6.1 0 No
No Fault Information 0 2.7 0 No
No Fault Information 0 5.3 0 No
No Fault Information 0 7.9 0 No
No Fault Information 0 7.9 0 No
No Fault Information 0 9.0 0 No
Unused Fault 0 7.9 0 No
Grid Fault -10 7.6 2 No
No Fault Information -3 7.9 2 No
Grid Fault -3 7.9 2 No
Grid Fault -3 7.9 2 No
Misc Information -3 7.9 2 No
No Fault Information -3 7.9 2 No
No Fault Information -3 7.2 2 No
Unused Fault -3 7.2 2 No
Unused Fault -3 7.2 2 No
No Fault Information -5 8.0 0 No
No Fault Information -5 8.0 0 No
User Information -5 8.0 0 No
User Information -5 8.0 0 No
No Fault Information -5 8.0 0 No
User Information -7 8.9 0 No
No Fault Information -5 7.9 0 No
No Fault Information -5 7.9 0 No
User Information -5 7.9 0 No
User Information -5 7.9 0 No
No Fault Information -5 7.9 0 No
No Fault Information -4 8.1 0 No
No Fault Information -4 8.1 0 No
User Information -4 7.7 0 No

WindSCADA 11.0 SP9.0 Page 58 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Safety Critical fault -4 7.7 0 No

No Fault Information -9 8.4 0 No


Multiple Fault -2 8.6 0 No
User Information -2 8.6 0 No
No Fault Information -2 8.6 0 No
Multiple Information -2 8.6 0 No
Azimuth Information -2 8.6 0 No
Pitch Warning -2 8.6 0 No
Pitch Warning -2 8.6 0 No
Pitch Warning -2 8.6 0 No
Multiple Safety Critical fault -2 8.6 0 No

Multiple Safety Critical fault -2 8.6 0 No

Frequency Fault -2 8.6 0 No


Converter
Misc Fault -2 0.0 0 No
Sensor Fault Fault -2 0.0 0 No
Azimuth Fault -2 0.0 0 No
Pitch Fault -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Pitch Warning -2 0.0 0 No
Grid Warning -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Generator Warning -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Brake Fault -2 0.0 0 No
Brake Warning -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 59 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Pitch Fault -2 0.0 0 No
No Fault Information -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Gearbox Fault -2 0.0 0 No
Brake Fault -2 0.0 0 No
Brake Warning -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 60 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
Grid Warning -2 0.0 0 No
Frequency Fault -2 0.0 0 No
Converter
Misc Fault -2 0.0 0 No
User Information -2 0.0 0 No
Grid Warning -2 7.0 0 No
Frequency Fault -2 7.0 0 No
Converter
Misc Fault -2 7.0 0 No
No Fault Information -2 8.2 0 No
Brake Fault -2 8.2 0 No
Brake Warning -2 8.2 0 No
Multiple Information -2 8.2 0 No
Generator Warning -2 8.2 0 No
Multiple Fault -2 8.2 0 No
Sensor Fault Fault -2 8.2 0 No
Gearbox Fault -2 8.2 0 No
Azimuth Fault -2 8.2 0 No
Azimuth Information -2 8.2 0 No
No Fault Information -2 7.9 0 No
No Fault Information -2 8.2 0 No
No Fault Information -2 9.0 0 No
No Fault Information -4 7.9 0 No

WindSCADA 11.0 SP9.0 Page 61 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
User Information -4 7.9 0 No
Multiple Safety Critical fault -4 7.9 0 No

Multiple Safety Critical fault -4 7.9 0 No

Multiple Safety Critical fault -4 7.9 0 No

No Fault Information -6 8.5 0 No


No Fault Information -6 8.5 0 No
No Fault Information -4 7.9 0 No
No Fault Information -5 7.7 0 No
No Fault Information -5 7.9 0 No
No Fault Information -5 7.9 0 No
Misc Information -5 8.6 0 No
Brake Fault -5 7.5 0 No
Brake Warning -5 7.5 0 No
No Fault Information -4 8.8 0 No
Misc Information -6 6.2 0 No
User Information -6 6.2 0 No
No Fault Information -6 6.2 0 No
User Information -6 6.2 0 No
Pitch Fault -6 6.2 0 No
Multiple Safety Critical fault -6 6.2 0 No

Multiple Safety Critical fault -6 6.2 0 No

User Information -6 6.2 0 No


Multiple Safety Critical fault -6 6.2 0 No

Misc Information -6 6.2 0 No


Multiple Warning -6 6.2 0 No
No Fault Information -6 6.2 0 No
User Information -6 6.2 0 No
Misc Fault -6 8.0 0 No
Grid Information -6 8.9 0 No
No Fault Information -6 8.9 0 No
No Fault Information -6 7.7 0 No
Misc Fault -6 7.7 0 No
Pitch Fault -6 7.7 0 No
No Fault Information -6 7.5 0 No
User Information -6 6.6 0 No
No Fault Information -6 6.5 0 No

WindSCADA 11.0 SP9.0 Page 62 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Safety Critical fault -6 6.5 0 No

Multiple Safety Critical fault -6 6.5 0 No

Multiple Safety Critical fault -6 6.5 0 No

No Fault Information -6 6.5 0 No


No Fault Information -8 7.1 0 No
Misc Information -6 8.0 0 No
User Information -5 7.0 0 No
No Fault Information -5 9.4 0 No
User Information -5 9.4 0 No
User Information -5 6.9 0 No
Brake Information -5 6.6 0 No
Brake Information -10 7.2 0 No
Grid Information -3 5.2 18 No

No Fault Information -3 5.2 18 No


No Fault Information -3 5.2 18 No
No Fault Information -6 7.0 92 No
No Fault Information -6 7.0 92 No
Gearbox Information -6 7.0 92 No
Gearbox Information -6 4.6 1060 No
No Fault Information 36 4.6 1042 No
No Fault Information 36 4.6 1042 No
No Fault Information 261 6.5 1030 No
User Information 261 6.5 1030 No
No Fault Information 261 6.5 1030 No
No Fault Information 261 6.5 1030 No
No Fault Information -10 5.0 1084 No
No Fault Information -10 5.0 1084 No
User Information -8 3.6 798 No
No Fault Information -9 6.9 261 No
User Information -2 6.9 24 No
User Information -2 6.9 24 No
No Fault Information -2 6.9 24 No
No Fault Information -5 7.0 24 No
No Fault Information -4 6.0 88 No
No Fault Information -4 6.0 88 No
No Fault Information -15 5.4 1045 No
No Fault Information -15 5.4 1045 No

WindSCADA 11.0 SP9.0 Page 63 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault Information 622 7.6 1252 No

T_141, EVENT_142, EVENT_286, EVENT_100015

WindSCADA 11.0 SP9.0 Page 64 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

Selected Systems:

* The value for the below 3 fields 'Power, WindSpeed and Gen.Speed' will be displayed as '-' when the data is missing

System Timestamp Status Name Description

HAWA23 2/2/2024 3:00:17 AM ON EVENT_383 Uncontrol battery test active


HAWA23 2/2/2024 3:00:17 AM OFF EVENT_006 System OK
HAWA23 2/2/2024 3:01:58 AM ON EVENT_157 Secondary rotor brake does not close
HAWA23 2/2/2024 3:02:23 AM OFF EVENT_383 Uncontrol battery test active
HAWA23 2/2/2024 3:02:37 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA23 2/2/2024 3:02:39 AM ON EVENT_006 System OK
HAWA23 2/4/2024 5:40:39 AM ON EVENT_1226 Grid frequency
HAWA23 2/4/2024 5:40:39 AM ON EVENT_543 Turbine Limit Protection Over Frequency
HAWA23 2/4/2024 5:40:39 AM OFF EVENT_006 System OK
HAWA23 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA23 2/4/2024 5:40:39 AM ON EVENT_116 Grid voltage fault
HAWA23 2/4/2024 5:40:39 AM ON EVENT_1202 Contactor or Breaker
HAWA23 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA23 2/4/2024 5:40:52 AM ON EVENT_345 Battery drive after grid fault
HAWA23 2/4/2024 5:40:52 AM ON EVENT_144 Blade angle asymmetry
HAWA23 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA23 2/4/2024 5:45:53 AM OFF EVENT_133 Batteries Charging
HAWA23 2/4/2024 5:45:54 AM ON EVENT_388 Communication fault pitch controller Axis 3
HAWA23 2/4/2024 5:45:54 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA23 2/4/2024 5:45:54 AM ON EVENT_120 Pitch controller communications fault
HAWA23 2/4/2024 5:45:54 AM OFF EVENT_388 Communication fault pitch controller Axis 3
HAWA23 2/4/2024 5:45:54 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA23 2/4/2024 11:21:20 AM ON EVENT_120 Pitch controller communications fault
HAWA23 2/4/2024 11:21:20 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA23 2/4/2024 11:21:20 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA23 2/4/2024 11:21:20 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA23 2/4/2024 11:21:20 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA23 2/4/2024 11:21:22 AM ON EVENT_001 Program start PLC


HAWA23 2/4/2024 11:21:28 AM OFF EVENT_120 Pitch controller communications fault
HAWA23 2/4/2024 11:21:39 AM OFF EVENT_001 Program start PLC
HAWA23 2/4/2024 11:21:39 AM ON EVENT_006 System OK
HAWA23 2/5/2024 12:02:42 AM ON EVENT_157 Secondary rotor brake does not close

WindSCADA 11.0 SP9.0 Page 65 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA23 2/5/2024 12:02:42 AM OFF EVENT_006 System OK


HAWA23 2/5/2024 12:03:41 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA23 2/5/2024 12:03:47 AM ON EVENT_006 System OK
HAWA23 2/9/2024 2:00:33 AM ON EVENT_383 Uncontrol battery test active
HAWA23 2/9/2024 2:00:33 AM OFF EVENT_006 System OK
HAWA23 2/9/2024 2:00:55 AM ON EVENT_157 Secondary rotor brake does not close
HAWA23 2/9/2024 2:02:15 AM OFF EVENT_383 Uncontrol battery test active
HAWA23 2/9/2024 2:03:22 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA23 2/9/2024 2:03:25 AM ON EVENT_006 System OK
HAWA23 2/16/2024 1:00:49 AM ON EVENT_383 Uncontrol battery test active
HAWA23 2/16/2024 1:00:49 AM OFF EVENT_006 System OK
HAWA23 2/16/2024 1:02:20 AM ON EVENT_157 Secondary rotor brake does not close
HAWA23 2/16/2024 1:02:54 AM OFF EVENT_383 Uncontrol battery test active
HAWA23 2/16/2024 1:03:31 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA23 2/16/2024 1:03:33 AM ON EVENT_006 System OK
HAWA24 2/3/2024 7:08:49 PM ON EVENT_383 Uncontrol battery test active
HAWA24 2/3/2024 7:08:49 PM OFF EVENT_006 System OK
HAWA24 2/3/2024 7:10:57 PM OFF EVENT_383 Uncontrol battery test active
HAWA24 2/3/2024 7:10:57 PM ON EVENT_006 System OK
HAWA24 2/4/2024 5:40:39 AM ON EVENT_1226 Grid frequency
HAWA24 2/4/2024 5:40:39 AM ON EVENT_543 Turbine Limit Protection Over Frequency
HAWA24 2/4/2024 5:40:39 AM OFF EVENT_006 System OK
HAWA24 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA24 2/4/2024 5:40:39 AM ON EVENT_116 Grid voltage fault
HAWA24 2/4/2024 5:40:39 AM ON EVENT_1202 Contactor or Breaker
HAWA24 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA24 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA24 2/4/2024 5:46:03 AM ON EVENT_447 Pitch rate deviation axis 1
HAWA24 2/4/2024 5:46:04 AM OFF EVENT_133 Batteries Charging
HAWA24 2/4/2024 5:46:04 AM ON EVENT_449 Pitch rate deviation axis 3
HAWA24 2/4/2024 5:46:04 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA24 2/4/2024 5:46:04 AM ON EVENT_345 Battery drive after grid fault
HAWA24 2/4/2024 5:46:04 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA24 2/4/2024 5:46:05 AM ON EVENT_388 Communication fault pitch controller Axis 3
HAWA24 2/4/2024 5:46:05 AM OFF EVENT_345 Battery drive after grid fault
HAWA24 2/4/2024 5:46:05 AM OFF EVENT_388 Communication fault pitch controller Axis 3
HAWA24 2/4/2024 5:46:05 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA24 2/4/2024 5:46:05 AM ON EVENT_120 Pitch controller communications fault
HAWA24 2/4/2024 5:46:08 AM ON EVENT_358 Malfunction Triplepitch System

WindSCADA 11.0 SP9.0 Page 66 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA24 2/4/2024 5:46:08 AM ON EVENT_578 Malfunction Triplepitch System Axis 3

HAWA24 2/4/2024 5:46:08 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA24 2/4/2024 5:46:08 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA24 2/4/2024 11:21:08 AM ON EVENT_120 Pitch controller communications fault
HAWA24 2/4/2024 11:21:08 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA24 2/4/2024 11:21:08 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA24 2/4/2024 11:21:08 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA24 2/4/2024 11:21:08 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA24 2/4/2024 11:21:08 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA24 2/4/2024 11:21:09 AM ON EVENT_001 Program start PLC


HAWA24 2/4/2024 11:21:15 AM OFF EVENT_120 Pitch controller communications fault
HAWA24 2/4/2024 11:21:25 AM OFF EVENT_001 Program start PLC
HAWA24 2/4/2024 11:26:06 AM ON EVENT_383 Uncontrol battery test active
HAWA24 2/4/2024 11:26:06 AM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA24 2/4/2024 11:27:17 AM OFF EVENT_383 Uncontrol battery test active
HAWA24 2/4/2024 11:27:17 AM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA24 2/4/2024 11:27:17 AM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA24 2/4/2024 11:27:17 AM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA24 2/4/2024 11:27:17 AM ON EVENT_006 System OK
HAWA24 2/4/2024 11:27:17 AM OFF EVENT_006 System OK
HAWA24 2/4/2024 11:27:33 AM ON EVENT_124 Pitch Overrun 0deg
HAWA24 2/4/2024 11:27:47 AM OFF EVENT_124 Pitch Overrun 0deg
HAWA24 2/4/2024 11:27:49 AM ON EVENT_144 Blade angle asymmetry
HAWA24 2/4/2024 11:27:57 AM OFF EVENT_144 Blade angle asymmetry
HAWA24 2/4/2024 11:32:17 AM ON EVENT_383 Uncontrol battery test active
HAWA24 2/4/2024 11:32:17 AM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA24 2/4/2024 11:32:17 AM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA24 2/4/2024 11:32:17 AM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA24 2/4/2024 11:33:59 AM OFF EVENT_383 Uncontrol battery test active
HAWA24 2/4/2024 11:33:59 AM ON EVENT_006 System OK
HAWA24 2/4/2024 11:39:29 AM ON EVENT_1201 Blown Fuses
HAWA24 2/4/2024 11:39:29 AM OFF EVENT_006 System OK
HAWA24 2/4/2024 11:40:51 AM OFF EVENT_1201 Blown Fuses

WindSCADA 11.0 SP9.0 Page 67 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA24 2/4/2024 11:40:58 AM ON EVENT_006 System OK


HAWA24 2/8/2024 6:00:23 AM ON EVENT_383 Uncontrol battery test active
HAWA24 2/8/2024 6:00:23 AM OFF EVENT_006 System OK
HAWA24 2/8/2024 6:02:04 AM OFF EVENT_383 Uncontrol battery test active
HAWA24 2/8/2024 6:02:05 AM ON EVENT_006 System OK
HAWA24 2/15/2024 4:59:45 AM ON EVENT_383 Uncontrol battery test active
HAWA24 2/15/2024 4:59:45 AM OFF EVENT_006 System OK
HAWA24 2/15/2024 5:01:47 AM OFF EVENT_383 Uncontrol battery test active
HAWA24 2/15/2024 5:01:47 AM ON EVENT_006 System OK
HAWA25 2/4/2024 5:40:37 AM ON EVENT_116 Grid voltage fault
HAWA25 2/4/2024 5:40:37 AM OFF EVENT_006 System OK
HAWA25 2/4/2024 5:40:37 AM ON EVENT_008 Overvoltage
HAWA25 2/4/2024 5:40:38 AM ON EVENT_1202 Contactor or Breaker
HAWA25 2/4/2024 5:40:38 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA25 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA25 2/4/2024 5:45:39 AM ON EVENT_133 Batteries Charging
HAWA25 2/4/2024 5:46:02 AM ON EVENT_447 Pitch rate deviation axis 1
HAWA25 2/4/2024 5:46:02 AM OFF EVENT_133 Batteries Charging
HAWA25 2/4/2024 5:46:02 AM ON EVENT_449 Pitch rate deviation axis 3
HAWA25 2/4/2024 5:46:02 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA25 2/4/2024 5:46:03 AM ON EVENT_345 Battery drive after grid fault
HAWA25 2/4/2024 5:46:03 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA25 2/4/2024 5:46:03 AM ON EVENT_388 Communication fault pitch controller Axis 3
HAWA25 2/4/2024 5:46:03 AM ON EVENT_120 Pitch controller communications fault
HAWA25 2/4/2024 5:46:03 AM OFF EVENT_345 Battery drive after grid fault
HAWA25 2/4/2024 5:46:03 AM OFF EVENT_388 Communication fault pitch controller Axis 3
HAWA25 2/4/2024 5:46:03 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA25 2/4/2024 5:46:07 AM ON EVENT_358 Malfunction Triplepitch System

HAWA25 2/4/2024 5:46:07 AM ON EVENT_578 Malfunction Triplepitch System Axis 3

HAWA25 2/4/2024 5:46:07 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA25 2/4/2024 5:46:07 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA25 2/4/2024 11:21:17 AM ON EVENT_120 Pitch controller communications fault
HAWA25 2/4/2024 11:21:17 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA25 2/4/2024 11:21:17 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/4/2024 11:21:17 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 68 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA25 2/4/2024 11:21:17 AM ON EVENT_009 Undervoltage


HAWA25 2/4/2024 11:21:17 AM ON EVENT_116 Grid voltage fault
HAWA25 2/4/2024 11:21:17 AM ON EVENT_008 Overvoltage
HAWA25 2/4/2024 11:21:17 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 11:21:17 AM ON EVENT_208 Converter communication fault

HAWA25 2/4/2024 11:21:18 AM ON EVENT_001 Program start PLC


HAWA25 2/4/2024 11:21:24 AM ON EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 11:21:24 AM ON EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 11:21:24 AM ON EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 11:21:35 AM OFF EVENT_001 Program start PLC


HAWA25 2/4/2024 11:23:18 AM OFF EVENT_120 Pitch controller communications fault
HAWA25 2/4/2024 12:02:59 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA25 2/4/2024 12:03:32 PM OFF EVENT_008 Overvoltage


HAWA25 2/4/2024 12:03:32 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 12:03:32 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 12:03:32 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 12:03:33 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 12:03:33 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 12:03:33 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 12:08:07 PM ON EVENT_120 Pitch controller communications fault


HAWA25 2/4/2024 12:08:07 PM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA25 2/4/2024 12:08:07 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/4/2024 12:08:07 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/4/2024 12:08:07 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA25 2/4/2024 12:08:07 PM ON EVENT_009 Undervoltage


HAWA25 2/4/2024 12:08:07 PM ON EVENT_116 Grid voltage fault
HAWA25 2/4/2024 12:08:07 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 12:08:07 PM ON EVENT_208 Converter communication fault

HAWA25 2/4/2024 12:08:09 PM ON EVENT_001 Program start PLC


HAWA25 2/4/2024 12:08:15 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 12:08:15 PM ON EVENT_214 Battery voltage not OK axis 3

WindSCADA 11.0 SP9.0 Page 69 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA25 2/4/2024 12:08:15 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 12:08:25 PM OFF EVENT_001 Program start PLC


HAWA25 2/4/2024 12:14:34 PM ON EVENT_120 Pitch controller communications fault
HAWA25 2/4/2024 12:14:34 PM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA25 2/4/2024 12:14:34 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/4/2024 12:14:34 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/4/2024 12:14:34 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA25 2/4/2024 12:14:34 PM ON EVENT_009 Undervoltage


HAWA25 2/4/2024 12:14:34 PM ON EVENT_116 Grid voltage fault
HAWA25 2/4/2024 12:14:34 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 12:14:34 PM ON EVENT_208 Converter communication fault

HAWA25 2/4/2024 12:14:35 PM ON EVENT_001 Program start PLC


HAWA25 2/4/2024 12:14:41 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 12:14:41 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 12:14:41 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 12:14:51 PM OFF EVENT_001 Program start PLC


HAWA25 2/4/2024 12:16:34 PM OFF EVENT_120 Pitch controller communications fault
HAWA25 2/4/2024 1:24:59 PM OFF EVENT_208 Converter communication fault

HAWA25 2/4/2024 1:25:00 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_009 Undervoltage
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_116 Grid voltage fault
HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/4/2024 1:25:04 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA25 2/4/2024 1:25:05 PM ON EVENT_274 Pitch Converter not ready axis 1

HAWA25 2/4/2024 1:25:05 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA25 2/4/2024 1:25:05 PM ON EVENT_276 Pitch Converter not ready axis 3

HAWA25 2/4/2024 1:25:09 PM ON EVENT_157 Secondary rotor brake does not close
HAWA25 2/4/2024 1:25:14 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 1:25:14 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 1:25:14 PM OFF EVENT_212 Battery voltage not OK axis 1

WindSCADA 11.0 SP9.0 Page 70 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA25 2/4/2024 1:25:14 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 1:25:14 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 1:25:14 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA25 2/4/2024 1:25:24 PM OFF EVENT_276 Pitch Converter not ready axis 3

HAWA25 2/4/2024 1:26:17 PM OFF EVENT_157 Secondary rotor brake does not close
HAWA25 2/4/2024 1:30:33 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:30:33 PM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA25 2/4/2024 1:31:19 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:31:19 PM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA25 2/4/2024 1:31:19 PM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA25 2/4/2024 1:31:19 PM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA25 2/4/2024 1:31:24 PM ON EVENT_124 Pitch Overrun 0deg
HAWA25 2/4/2024 1:31:29 PM OFF EVENT_124 Pitch Overrun 0deg
HAWA25 2/4/2024 1:36:29 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA25 2/4/2024 1:36:29 PM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA25 2/4/2024 1:38:10 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/4/2024 1:38:41 PM ON EVENT_006 System OK
HAWA25 2/11/2024 12:36:17 PM ON EVENT_383 Uncontrol battery test active
HAWA25 2/11/2024 12:36:17 PM OFF EVENT_006 System OK
HAWA25 2/11/2024 12:38:27 PM OFF EVENT_383 Uncontrol battery test active
HAWA25 2/11/2024 12:38:27 PM ON EVENT_006 System OK
HAWA25 2/18/2024 11:36:33 AM ON EVENT_383 Uncontrol battery test active
HAWA25 2/18/2024 11:36:33 AM OFF EVENT_006 System OK
HAWA25 2/18/2024 11:38:20 AM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 11:38:20 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 11:38:21 AM ON EVENT_201 IO Card 28V power supply failed or
Communication failure

WindSCADA 11.0 SP9.0 Page 71 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA25 2/18/2024 11:38:36 AM OFF EVENT_383 Uncontrol battery test active


HAWA25 2/18/2024 11:41:32 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA25 2/18/2024 11:41:33 AM OFF EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 11:41:33 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 11:41:39 AM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 11:41:39 AM ON EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA25 2/18/2024 11:41:40 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 11:44:28 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA25 2/18/2024 11:44:29 AM OFF EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 11:44:29 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 11:44:46 AM ON EVENT_006 System OK
HAWA25 2/18/2024 12:29:51 PM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA25 2/18/2024 12:29:51 PM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 12:29:51 PM OFF EVENT_006 System OK
HAWA25 2/18/2024 12:29:52 PM ON EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA25 2/18/2024 1:01:20 PM ON EVENT_273 Manual or service time excessive
HAWA25 2/18/2024 2:32:30 PM ON EVENT_120 Pitch controller communications fault
HAWA25 2/18/2024 2:32:30 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/18/2024 2:32:30 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/18/2024 2:32:30 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/18/2024 2:32:30 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA25 2/18/2024 2:32:31 PM ON EVENT_001 Program start PLC


HAWA25 2/18/2024 2:32:37 PM OFF EVENT_120 Pitch controller communications fault
HAWA25 2/18/2024 2:32:47 PM OFF EVENT_001 Program start PLC
HAWA25 2/18/2024 2:34:58 PM ON EVENT_006 System OK
HAWA25 2/18/2024 2:40:33 PM ON EVENT_1204 Code sequencing
HAWA25 2/18/2024 2:40:33 PM ON EVENT_1218 Power Supply
HAWA25 2/18/2024 2:40:33 PM OFF EVENT_006 System OK
HAWA25 2/18/2024 2:40:33 PM ON EVENT_063 Safety chain

HAWA25 2/18/2024 2:46:35 PM ON EVENT_120 Pitch controller communications fault


HAWA25 2/18/2024 2:46:35 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/18/2024 2:46:35 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/18/2024 2:46:35 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 72 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA25 2/18/2024 2:46:35 PM ON EVENT_009 Undervoltage


HAWA25 2/18/2024 2:46:35 PM ON EVENT_116 Grid voltage fault
HAWA25 2/18/2024 2:46:35 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/18/2024 2:46:35 PM ON EVENT_208 Converter communication fault

HAWA25 2/18/2024 2:46:36 PM ON EVENT_001 Program start PLC


HAWA25 2/18/2024 2:46:52 PM OFF EVENT_001 Program start PLC
HAWA25 2/18/2024 2:46:59 PM OFF EVENT_208 Converter communication fault

HAWA25 2/18/2024 2:47:00 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_009 Undervoltage
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_116 Grid voltage fault
HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA25 2/18/2024 2:47:04 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA25 2/18/2024 2:47:07 PM OFF EVENT_120 Pitch controller communications fault


HAWA25 2/18/2024 2:47:54 PM ON EVENT_006 System OK
HAWA26 2/3/2024 7:08:49 PM ON EVENT_383 Uncontrol battery test active
HAWA26 2/3/2024 7:08:49 PM OFF EVENT_006 System OK
HAWA26 2/3/2024 7:10:53 PM OFF EVENT_383 Uncontrol battery test active
HAWA26 2/3/2024 7:10:53 PM ON EVENT_006 System OK
HAWA26 2/4/2024 5:40:38 AM ON EVENT_116 Grid voltage fault
HAWA26 2/4/2024 5:40:39 AM OFF EVENT_006 System OK
HAWA26 2/4/2024 5:40:39 AM ON EVENT_1202 Contactor or Breaker
HAWA26 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA26 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA26 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA26 2/4/2024 5:46:02 AM ON EVENT_447 Pitch rate deviation axis 1
HAWA26 2/4/2024 5:46:03 AM OFF EVENT_133 Batteries Charging
HAWA26 2/4/2024 5:46:04 AM ON EVENT_449 Pitch rate deviation axis 3
HAWA26 2/4/2024 5:46:04 AM ON EVENT_345 Battery drive after grid fault
HAWA26 2/4/2024 5:46:04 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA26 2/4/2024 5:46:04 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA26 2/4/2024 5:46:05 AM ON EVENT_388 Communication fault pitch controller Axis 3
HAWA26 2/4/2024 5:46:05 AM OFF EVENT_388 Communication fault pitch controller Axis 3
HAWA26 2/4/2024 5:46:05 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA26 2/4/2024 5:46:05 AM ON EVENT_120 Pitch controller communications fault
HAWA26 2/4/2024 5:46:05 AM OFF EVENT_345 Battery drive after grid fault
HAWA26 2/4/2024 5:46:08 AM ON EVENT_358 Malfunction Triplepitch System

WindSCADA 11.0 SP9.0 Page 73 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA26 2/4/2024 5:46:08 AM ON EVENT_578 Malfunction Triplepitch System Axis 3

HAWA26 2/4/2024 5:46:08 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA26 2/4/2024 5:46:08 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA26 2/4/2024 11:21:22 AM ON EVENT_120 Pitch controller communications fault
HAWA26 2/4/2024 11:21:22 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA26 2/4/2024 11:21:22 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA26 2/4/2024 11:21:22 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA26 2/4/2024 11:21:22 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA26 2/4/2024 11:21:22 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA26 2/4/2024 11:21:23 AM ON EVENT_001 Program start PLC


HAWA26 2/4/2024 11:21:31 AM OFF EVENT_120 Pitch controller communications fault
HAWA26 2/4/2024 11:21:40 AM OFF EVENT_001 Program start PLC
HAWA26 2/4/2024 11:26:20 AM ON EVENT_383 Uncontrol battery test active
HAWA26 2/4/2024 11:26:21 AM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA26 2/4/2024 11:27:31 AM OFF EVENT_383 Uncontrol battery test active
HAWA26 2/4/2024 11:27:31 AM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA26 2/4/2024 11:27:31 AM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA26 2/4/2024 11:27:31 AM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA26 2/4/2024 11:27:31 AM ON EVENT_006 System OK
HAWA26 2/4/2024 11:27:31 AM OFF EVENT_006 System OK
HAWA26 2/4/2024 11:27:43 AM ON EVENT_124 Pitch Overrun 0deg
HAWA26 2/4/2024 11:27:57 AM OFF EVENT_124 Pitch Overrun 0deg
HAWA26 2/4/2024 11:28:02 AM ON EVENT_144 Blade angle asymmetry
HAWA26 2/4/2024 11:28:07 AM OFF EVENT_144 Blade angle asymmetry
HAWA26 2/4/2024 11:32:31 AM ON EVENT_383 Uncontrol battery test active
HAWA26 2/4/2024 11:32:31 AM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA26 2/4/2024 11:32:31 AM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA26 2/4/2024 11:32:31 AM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA26 2/4/2024 11:34:11 AM OFF EVENT_383 Uncontrol battery test active
HAWA26 2/4/2024 11:34:11 AM ON EVENT_006 System OK
HAWA26 2/5/2024 12:03:46 AM ON EVENT_027 Secondary hydraulic braking time too long

HAWA26 2/5/2024 12:03:46 AM OFF EVENT_006 System OK

WindSCADA 11.0 SP9.0 Page 74 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA26 2/5/2024 12:08:50 AM OFF EVENT_027 Secondary hydraulic braking time too long

HAWA26 2/5/2024 12:08:58 AM ON EVENT_006 System OK


HAWA26 2/6/2024 6:01:24 AM ON EVENT_383 Uncontrol battery test active
HAWA26 2/6/2024 6:01:24 AM OFF EVENT_006 System OK
HAWA26 2/6/2024 6:03:04 AM OFF EVENT_383 Uncontrol battery test active
HAWA26 2/6/2024 6:03:04 AM ON EVENT_006 System OK
HAWA26 2/13/2024 5:01:53 AM ON EVENT_383 Uncontrol battery test active
HAWA26 2/13/2024 5:01:53 AM OFF EVENT_006 System OK
HAWA26 2/13/2024 5:03:32 AM OFF EVENT_383 Uncontrol battery test active
HAWA26 2/13/2024 5:03:32 AM ON EVENT_006 System OK
HAWA27 1/31/2024 2:50:41 PM ON EVENT_383 Uncontrol battery test active
HAWA27 1/31/2024 2:50:41 PM OFF EVENT_006 System OK
HAWA27 1/31/2024 2:52:22 PM OFF EVENT_383 Uncontrol battery test active
HAWA27 1/31/2024 2:52:22 PM ON EVENT_006 System OK
HAWA27 2/4/2024 5:40:37 AM ON EVENT_116 Grid voltage fault
HAWA27 2/4/2024 5:40:37 AM OFF EVENT_006 System OK
HAWA27 2/4/2024 5:40:38 AM ON EVENT_1202 Contactor or Breaker
HAWA27 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA27 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA27 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA27 2/4/2024 5:45:50 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA27 2/4/2024 5:45:51 AM ON EVENT_345 Battery drive after grid fault
HAWA27 2/4/2024 5:45:51 AM ON EVENT_387 Communication fault pitch controller Axis 2
HAWA27 2/4/2024 5:45:55 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA27 2/4/2024 5:45:55 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA27 2/4/2024 5:46:00 AM OFF EVENT_133 Batteries Charging
HAWA27 2/4/2024 5:46:01 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA27 2/4/2024 5:46:01 AM OFF EVENT_345 Battery drive after grid fault
HAWA27 2/4/2024 5:46:01 AM ON EVENT_120 Pitch controller communications fault
HAWA27 2/4/2024 5:46:01 AM OFF EVENT_387 Communication fault pitch controller Axis 2
HAWA27 2/4/2024 5:46:01 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA27 2/4/2024 6:00:35 AM ON EVENT_1218 Power Supply
HAWA27 2/4/2024 6:00:35 AM ON EVENT_063 Safety chain

HAWA27 2/4/2024 11:21:34 AM ON EVENT_120 Pitch controller communications fault


HAWA27 2/4/2024 11:21:34 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA27 2/4/2024 11:21:34 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 75 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA27 2/4/2024 11:21:34 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA27 2/4/2024 11:21:34 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA27 2/4/2024 11:21:34 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA27 2/4/2024 11:21:35 AM ON EVENT_001 Program start PLC


HAWA27 2/4/2024 11:21:41 AM OFF EVENT_120 Pitch controller communications fault
HAWA27 2/4/2024 11:21:42 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA27 2/4/2024 11:21:48 AM ON EVENT_144 Blade angle asymmetry


HAWA27 2/4/2024 11:21:51 AM OFF EVENT_001 Program start PLC
HAWA27 2/4/2024 11:21:51 AM OFF EVENT_144 Blade angle asymmetry
HAWA27 2/4/2024 11:22:01 AM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA27 2/4/2024 11:26:32 AM ON EVENT_383 Uncontrol battery test active


HAWA27 2/4/2024 11:26:32 AM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA27 2/4/2024 11:27:53 AM OFF EVENT_383 Uncontrol battery test active
HAWA27 2/4/2024 11:27:53 AM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA27 2/4/2024 11:27:53 AM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA27 2/4/2024 11:27:53 AM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA27 2/4/2024 11:27:53 AM ON EVENT_006 System OK
HAWA27 2/4/2024 11:27:53 AM OFF EVENT_006 System OK
HAWA27 2/4/2024 11:27:57 AM ON EVENT_124 Pitch Overrun 0deg
HAWA27 2/4/2024 11:28:03 AM OFF EVENT_124 Pitch Overrun 0deg
HAWA27 2/4/2024 11:32:53 AM ON EVENT_383 Uncontrol battery test active
HAWA27 2/4/2024 11:32:53 AM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA27 2/4/2024 11:32:53 AM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA27 2/4/2024 11:32:53 AM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA27 2/4/2024 11:34:33 AM OFF EVENT_383 Uncontrol battery test active
HAWA27 2/4/2024 11:34:33 AM ON EVENT_006 System OK
HAWA27 2/6/2024 6:01:34 AM ON EVENT_383 Uncontrol battery test active
HAWA27 2/6/2024 6:01:34 AM OFF EVENT_006 System OK
HAWA27 2/6/2024 6:02:01 AM ON EVENT_157 Secondary rotor brake does not close
HAWA27 2/6/2024 6:03:15 AM OFF EVENT_383 Uncontrol battery test active
HAWA27 2/6/2024 6:05:27 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA27 2/6/2024 6:05:46 AM ON EVENT_006 System OK
HAWA27 2/13/2024 5:01:53 AM ON EVENT_383 Uncontrol battery test active
HAWA27 2/13/2024 5:01:53 AM OFF EVENT_006 System OK

WindSCADA 11.0 SP9.0 Page 76 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA27 2/13/2024 5:02:05 AM ON EVENT_157 Secondary rotor brake does not close
HAWA27 2/13/2024 5:03:33 AM OFF EVENT_383 Uncontrol battery test active
HAWA27 2/13/2024 5:04:16 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA27 2/13/2024 5:04:34 AM ON EVENT_006 System OK
HAWA27 2/15/2024 10:21:51 AM ON EVENT_157 Secondary rotor brake does not close
HAWA27 2/15/2024 10:21:51 AM OFF EVENT_006 System OK
HAWA27 2/15/2024 10:22:31 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA27 2/15/2024 10:22:33 AM ON EVENT_006 System OK
HAWA28 2/3/2024 6:32:33 PM ON EVENT_383 Uncontrol battery test active
HAWA28 2/3/2024 6:32:33 PM OFF EVENT_006 System OK
HAWA28 2/3/2024 6:34:39 PM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/3/2024 6:34:39 PM ON EVENT_006 System OK
HAWA28 2/4/2024 5:40:39 AM ON EVENT_1226 Grid frequency
HAWA28 2/4/2024 5:40:39 AM ON EVENT_543 Turbine Limit Protection Over Frequency
HAWA28 2/4/2024 5:40:39 AM OFF EVENT_006 System OK
HAWA28 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA28 2/4/2024 5:40:39 AM ON EVENT_116 Grid voltage fault
HAWA28 2/4/2024 5:40:39 AM ON EVENT_1202 Contactor or Breaker
HAWA28 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA28 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA28 2/4/2024 5:45:52 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA28 2/4/2024 5:45:53 AM ON EVENT_387 Communication fault pitch controller Axis 2
HAWA28 2/4/2024 5:45:53 AM ON EVENT_345 Battery drive after grid fault
HAWA28 2/4/2024 5:45:57 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA28 2/4/2024 5:45:57 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA28 2/4/2024 5:46:01 AM OFF EVENT_133 Batteries Charging
HAWA28 2/4/2024 5:46:03 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA28 2/4/2024 5:46:06 AM OFF EVENT_387 Communication fault pitch controller Axis 2
HAWA28 2/4/2024 5:46:06 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/4/2024 5:46:06 AM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/4/2024 5:46:06 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA28 2/4/2024 6:00:35 AM ON EVENT_1218 Power Supply
HAWA28 2/4/2024 6:00:35 AM ON EVENT_063 Safety chain

HAWA28 2/4/2024 6:00:35 AM ON EVENT_177 Tower vibration


HAWA28 2/4/2024 6:00:36 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/4/2024 6:00:36 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/4/2024 6:00:36 AM ON EVENT_1209 HSSL / HSLA, Line converter

WindSCADA 11.0 SP9.0 Page 77 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/4/2024 6:00:36 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/4/2024 11:21:09 AM ON EVENT_120 Pitch controller communications fault


HAWA28 2/4/2024 11:21:09 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA28 2/4/2024 11:21:09 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/4/2024 11:21:09 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/4/2024 11:21:10 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/4/2024 11:21:10 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/4/2024 11:21:11 AM ON EVENT_001 Program start PLC


HAWA28 2/4/2024 11:21:17 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/4/2024 11:21:18 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/4/2024 11:21:18 AM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/4/2024 11:21:24 AM ON EVENT_144 Blade angle asymmetry


HAWA28 2/4/2024 11:21:27 AM OFF EVENT_001 Program start PLC
HAWA28 2/4/2024 11:21:27 AM OFF EVENT_144 Blade angle asymmetry
HAWA28 2/4/2024 11:21:37 AM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/4/2024 11:21:37 AM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/4/2024 11:26:07 AM ON EVENT_383 Uncontrol battery test active


HAWA28 2/4/2024 11:26:07 AM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA28 2/4/2024 11:27:28 AM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/4/2024 11:27:28 AM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA28 2/4/2024 11:27:28 AM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA28 2/4/2024 11:27:28 AM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA28 2/4/2024 11:27:28 AM ON EVENT_006 System OK
HAWA28 2/4/2024 11:27:28 AM OFF EVENT_006 System OK
HAWA28 2/4/2024 11:27:33 AM ON EVENT_124 Pitch Overrun 0deg
HAWA28 2/4/2024 11:27:38 AM OFF EVENT_124 Pitch Overrun 0deg
HAWA28 2/4/2024 11:27:58 AM ON EVENT_144 Blade angle asymmetry
HAWA28 2/4/2024 11:27:59 AM OFF EVENT_144 Blade angle asymmetry
HAWA28 2/4/2024 11:32:28 AM ON EVENT_383 Uncontrol battery test active
HAWA28 2/4/2024 11:32:28 AM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA28 2/4/2024 11:32:28 AM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA28 2/4/2024 11:32:28 AM OFF EVENT_566 Emergency Brake System Test required axis
2

WindSCADA 11.0 SP9.0 Page 78 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/4/2024 11:34:06 AM OFF EVENT_383 Uncontrol battery test active


HAWA28 2/4/2024 11:34:06 AM ON EVENT_006 System OK
HAWA28 2/6/2024 6:00:00 AM ON EVENT_383 Uncontrol battery test active
HAWA28 2/6/2024 6:00:01 AM OFF EVENT_006 System OK
HAWA28 2/6/2024 6:01:39 AM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/6/2024 6:01:39 AM ON EVENT_006 System OK
HAWA28 2/8/2024 1:30:35 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/8/2024 1:30:36 AM OFF EVENT_006 System OK
HAWA28 2/8/2024 1:32:10 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/8/2024 1:32:28 AM ON EVENT_006 System OK
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1262 IOC, Rotor Converter
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1253 Ground Fault, Rotor
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1205 DC Link over-voltage
HAWA28 2/11/2024 2:39:56 PM ON EVENT_1288 Overspeed
HAWA28 2/11/2024 2:39:56 PM OFF EVENT_006 System OK
HAWA28 2/11/2024 2:39:56 PM ON EVENT_014 Generator overspeed

HAWA28 2/11/2024 2:39:56 PM ON EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/11/2024 3:23:33 PM ON EVENT_273 Manual or service time excessive


HAWA28 2/11/2024 4:15:07 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/11/2024 4:15:07 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/11/2024 4:15:07 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/11/2024 4:15:07 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/11/2024 4:15:08 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/11/2024 4:15:09 PM ON EVENT_001 Program start PLC


HAWA28 2/11/2024 4:15:15 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/11/2024 4:15:16 PM ON EVENT_1062 Pitch Conv. DC Link voltage low axis 1

HAWA28 2/11/2024 4:15:16 PM ON EVENT_1063 Pitch Conv. DC Link voltage low axis 2

HAWA28 2/11/2024 4:15:22 PM ON EVENT_144 Blade angle asymmetry


HAWA28 2/11/2024 4:15:26 PM OFF EVENT_001 Program start PLC
HAWA28 2/11/2024 4:15:27 PM OFF EVENT_144 Blade angle asymmetry
HAWA28 2/11/2024 4:16:17 PM OFF EVENT_1062 Pitch Conv. DC Link voltage low axis 1

WindSCADA 11.0 SP9.0 Page 79 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/11/2024 4:16:17 PM OFF EVENT_1063 Pitch Conv. DC Link voltage low axis 2

HAWA28 2/11/2024 4:16:45 PM ON EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/11/2024 4:16:45 PM ON EVENT_116 Grid voltage fault


HAWA28 2/11/2024 4:16:46 PM ON EVENT_009 Undervoltage
HAWA28 2/11/2024 4:16:46 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/11/2024 4:16:46 PM ON EVENT_208 Converter communication fault

HAWA28 2/11/2024 4:18:55 PM OFF EVENT_208 Converter communication fault

HAWA28 2/11/2024 4:18:57 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/11/2024 4:19:00 PM OFF EVENT_009 Undervoltage
HAWA28 2/11/2024 4:19:00 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/11/2024 4:19:37 PM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/11/2024 4:20:21 PM ON EVENT_006 System OK


HAWA28 2/13/2024 4:59:45 AM ON EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 4:59:45 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 5:01:25 AM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 5:01:25 AM ON EVENT_006 System OK
HAWA28 2/13/2024 5:28:49 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 5:28:49 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 5:31:13 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 5:31:31 AM ON EVENT_006 System OK
HAWA28 2/13/2024 8:58:31 AM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 8:58:31 AM OFF EVENT_006 System OK
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1205 DC Link over-voltage
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1262 IOC, Rotor Converter
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1288 Overspeed
HAWA28 2/13/2024 8:58:40 AM ON EVENT_1253 Ground Fault, Rotor
HAWA28 2/13/2024 8:58:40 AM ON EVENT_014 Generator overspeed

HAWA28 2/13/2024 8:58:40 AM ON EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/13/2024 9:37:10 AM ON EVENT_273 Manual or service time excessive


HAWA28 2/13/2024 10:14:13 AM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 10:14:13 AM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:14:13 AM OFF EVENT_014 Generator overspeed

WindSCADA 11.0 SP9.0 Page 80 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:14:13 AM ON EVENT_419 CCU reports Generator over speed

HAWA28 2/13/2024 10:14:14 AM OFF EVENT_419 CCU reports Generator over speed

HAWA28 2/13/2024 10:14:14 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:14 AM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 10:14:14 AM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:14 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1205 DC Link over-voltage
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1262 IOC, Rotor Converter
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1288 Overspeed
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1253 Ground Fault, Rotor
HAWA28 2/13/2024 10:14:14 AM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 10:14:15 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:21 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:21 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:22 AM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:22 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:23 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:14:51 AM OFF EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/13/2024 10:14:53 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 10:14:53 AM ON EVENT_275 Pitch Converter not ready axis 2

WindSCADA 11.0 SP9.0 Page 81 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:14:58 AM ON EVENT_344 Pitch malfunction 2 or 3 blades

HAWA28 2/13/2024 10:15:09 AM ON EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM ON EVENT_116 Grid voltage fault


HAWA28 2/13/2024 10:15:09 AM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 10:15:09 AM ON EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_344 Pitch malfunction 2 or 3 blades

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 10:15:09 AM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 10:15:09 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:09 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:09 AM ON EVENT_208 Converter communication fault

HAWA28 2/13/2024 10:15:09 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:09 AM ON EVENT_101 DTA or MCC Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:10 AM ON EVENT_041 Tower vibration sensor failure


HAWA28 2/13/2024 10:15:10 AM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:15:10 AM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:15:12 AM ON EVENT_1277 MarkStat Process
HAWA28 2/13/2024 10:15:12 AM OFF EVENT_208 Converter communication fault

HAWA28 2/13/2024 10:15:14 AM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 10:15:17 AM OFF EVENT_009 Undervoltage
HAWA28 2/13/2024 10:15:17 AM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 10:15:27 AM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:27 AM OFF EVENT_101 DTA or MCC Fuse or Motor protection alarm

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_177 Tower vibration


HAWA28 2/13/2024 10:15:50 AM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 82 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 10:15:50 AM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 10:15:51 AM OFF EVENT_1277 MarkStat Process


HAWA28 2/13/2024 10:23:15 AM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 10:23:15 AM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 10:23:25 AM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 10:23:25 AM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 11:17:40 AM ON EVENT_1202 Contactor or Breaker
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1218 Power Supply
HAWA28 2/13/2024 11:22:38 AM ON EVENT_063 Safety chain

HAWA28 2/13/2024 11:22:38 AM ON EVENT_177 Tower vibration


HAWA28 2/13/2024 11:22:38 AM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA28 2/13/2024 11:22:38 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:22:38 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:22:38 AM ON EVENT_1210 HSSL / HSLA, Rotor converter


HAWA28 2/13/2024 11:22:39 AM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 11:36:31 AM ON EVENT_120 Pitch controller communications fault


HAWA28 2/13/2024 11:36:31 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM ON EVENT_009 Undervoltage


HAWA28 2/13/2024 11:36:31 AM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 11:36:31 AM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 11:36:31 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 11:36:33 AM ON EVENT_001 Program start PLC


HAWA28 2/13/2024 11:36:39 AM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 11:36:39 AM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 11:36:39 AM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 11:36:39 AM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA28 2/13/2024 11:36:49 AM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 11:38:31 AM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 11:46:00 AM ON EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 11:46:00 AM ON EVENT_345 Battery drive after grid fault

WindSCADA 11.0 SP9.0 Page 83 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 11:46:00 AM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 12:36:50 PM ON EVENT_1228 Tachometer


HAWA28 2/13/2024 12:38:07 PM ON EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 1:03:19 PM OFF EVENT_1518 Drive Train Speed with Braked WTG Opened
Safety Chain
HAWA28 2/13/2024 1:03:19 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 1:03:19 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 1:03:19 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 1:03:19 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 1:03:20 PM OFF EVENT_1228 Tachometer


HAWA28 2/13/2024 1:03:21 PM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 1:03:21 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 1:03:21 PM ON EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 1:03:21 PM ON EVENT_345 Battery drive after grid fault


HAWA28 2/13/2024 1:10:12 PM ON EVENT_177 Tower vibration
HAWA28 2/13/2024 1:10:12 PM ON EVENT_063 Safety chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 1:10:12 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 1:10:13 PM ON EVENT_041 Tower vibration sensor failure


HAWA28 2/13/2024 1:10:13 PM ON EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 1:10:13 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 1:10:32 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 1:11:12 PM ON EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 1:11:12 PM ON EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 1:20:21 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 1:56:10 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 1:59:59 PM ON EVENT_201 IO Card 28V power supply failed or
Communication failure

WindSCADA 11.0 SP9.0 Page 84 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:04 PM OFF EVENT_063 Safety chain

HAWA28 2/13/2024 2:00:04 PM OFF EVENT_009 Undervoltage


HAWA28 2/13/2024 2:00:04 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_345 Battery drive after grid fault
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:10 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:00:10 PM OFF EVENT_276 Pitch Converter not ready axis 3

HAWA28 2/13/2024 2:00:10 PM ON EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:00:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:10 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:11 PM OFF EVENT_1242 Grid Loss
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:12 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:12 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:13 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:13 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:13 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:13 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:14 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:14 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:14 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

WindSCADA 11.0 SP9.0 Page 85 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:24 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:25 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:34 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:37 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:37 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:44 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:53 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:53 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:54 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:54 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:54 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:54 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure

WindSCADA 11.0 SP9.0 Page 86 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:55 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:00:58 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:00:59 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:00:59 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:00 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:00 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:00 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:00 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:01 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:01 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:04 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:06 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:01:09 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 87 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:09 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:09 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:10 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:10 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:10 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:11 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:11 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:11 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:11 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:24 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:24 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:31 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:32 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:32 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:32 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:33 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:33 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:33 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:33 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 88 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:01:33 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:33 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:34 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:34 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:34 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:34 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:34 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:36 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:36 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:36 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:36 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:37 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:01:37 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:37 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:44 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:44 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:54 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:54 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:01:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:01:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:01:56 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:02:04 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:04 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

WindSCADA 11.0 SP9.0 Page 89 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:02:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:14 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:14 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:45 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:02:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:02:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:02:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:05 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:15 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:15 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:15 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:25 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:25 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:25 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:25 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure

WindSCADA 11.0 SP9.0 Page 90 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:03:35 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:35 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:35 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:35 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:45 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:45 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:45 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:45 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:03:55 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:55 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:03:55 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:03:55 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:04:05 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:05 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:05 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:05 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 2:04:15 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 2:04:15 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:04:21 PM ON EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:04:23 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:23 PM ON EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:04:23 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:04:23 PM ON EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:04:23 PM OFF EVENT_297 Turbine warm up error

WindSCADA 11.0 SP9.0 Page 91 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:04:24 PM ON EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:04:35 PM OFF EVENT_274 Pitch Converter not ready axis 1

HAWA28 2/13/2024 2:04:35 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/13/2024 2:04:39 PM OFF EVENT_297 Turbine warm up error


HAWA28 2/13/2024 2:04:40 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:53 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:04:53 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:05 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:06 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:05:13 PM OFF EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 2:05:43 PM ON EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 2:05:43 PM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA28 2/13/2024 2:07:23 PM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/13/2024 2:07:37 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:09:06 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:09:07 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:09:07 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:10:23 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:10:24 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:11:02 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:13:20 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:13:21 PM ON EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:14:14 PM OFF EVENT_297 Turbine warm up error
HAWA28 2/13/2024 2:14:18 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:32 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:19:45 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:45 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:19:48 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:48 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:19:49 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:19:49 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:20:47 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:47 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:20:48 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:48 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:20:50 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 2:20:50 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:20:53 PM ON EVENT_1228 Tachometer

WindSCADA 11.0 SP9.0 Page 92 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 2:20:53 PM OFF EVENT_006 System OK


HAWA28 2/13/2024 2:27:11 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 2:27:11 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:27:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 2:27:12 PM ON EVENT_001 Program start PLC


HAWA28 2/13/2024 2:27:19 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 2:27:22 PM OFF EVENT_001 Program start PLC


HAWA28 2/13/2024 2:28:17 PM ON EVENT_006 System OK
HAWA28 2/13/2024 2:53:31 PM ON EVENT_116 Grid voltage fault
HAWA28 2/13/2024 2:53:31 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 2:53:31 PM ON EVENT_009 Undervoltage
HAWA28 2/13/2024 2:53:42 PM ON EVENT_1242 Grid Loss
HAWA28 2/13/2024 2:53:42 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 2:59:45 PM ON EVENT_273 Manual or service time excessive
HAWA28 2/13/2024 7:32:10 PM ON EVENT_1228 Tachometer
HAWA28 2/13/2024 7:42:04 PM OFF EVENT_367 CCU fault at abnormal grid condition
HAWA28 2/13/2024 7:42:09 PM OFF EVENT_009 Undervoltage
HAWA28 2/13/2024 7:42:09 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/13/2024 7:42:10 PM OFF EVENT_1242 Grid Loss
HAWA28 2/13/2024 7:42:10 PM OFF EVENT_1228 Tachometer
HAWA28 2/13/2024 7:44:27 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 7:44:32 PM ON EVENT_177 Tower vibration


HAWA28 2/13/2024 7:44:32 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 7:44:32 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 7:44:32 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:33 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:33 PM ON EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:44:33 PM ON EVENT_082 Yaw motor over temperature

WindSCADA 11.0 SP9.0 Page 93 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:44:34 PM ON EVENT_120 Pitch controller communications fault


HAWA28 2/13/2024 7:44:37 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:37 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:38 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:47 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:47 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:48 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:44:52 PM ON EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:44:57 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:57 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:44:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:44:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:07 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:07 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 7:45:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:08 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:17 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:17 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:18 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:18 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:27 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:27 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:28 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:28 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:32 PM ON EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:45:32 PM ON EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 7:45:38 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:38 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:38 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:38 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure

WindSCADA 11.0 SP9.0 Page 94 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 7:45:48 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:48 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:48 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:48 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:45:58 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:58 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:45:58 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:45:58 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:46:08 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:08 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:08 PM ON EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:08 PM ON EVENT_201 IO Card 28V power supply failed or


Communication failure
HAWA28 2/13/2024 7:46:18 PM OFF EVENT_102 Top Box Fuse or Motor protection alarm

HAWA28 2/13/2024 7:46:18 PM OFF EVENT_201 IO Card 28V power supply failed or
Communication failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_086 Secondary brake pads worn
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_177 Tower vibration
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_041 Tower vibration sensor failure
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_072 Gearbox oil over temperature from thermal
switch
HAWA28 2/13/2024 7:46:24 PM OFF EVENT_082 Yaw motor over temperature
HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 7:46:36 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA28 2/13/2024 7:47:13 PM OFF EVENT_280 Hydraulic brake test accumulator pressure
error
HAWA28 2/13/2024 8:01:28 PM ON EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:28 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 8:01:28 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 8:01:28 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/13/2024 8:01:29 PM ON EVENT_001 Program start PLC


HAWA28 2/13/2024 8:01:32 PM OFF EVENT_001 Program start PLC
HAWA28 2/13/2024 8:01:32 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/13/2024 8:01:41 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 95 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/13/2024 8:04:38 PM ON EVENT_006 System OK


HAWA28 2/13/2024 8:12:44 PM OFF EVENT_006 System OK
HAWA28 2/13/2024 8:25:28 PM ON EVENT_006 System OK
HAWA28 2/14/2024 4:49:23 PM ON EVENT_1202 Contactor or Breaker
HAWA28 2/14/2024 4:49:23 PM ON EVENT_1233 DC Link under-voltage
HAWA28 2/14/2024 4:49:23 PM ON EVENT_1201 Blown Fuses
HAWA28 2/14/2024 4:49:23 PM ON EVENT_1253 Ground Fault, Rotor
HAWA28 2/14/2024 4:49:23 PM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/14/2024 4:49:23 PM OFF EVENT_006 System OK
HAWA28 2/14/2024 4:49:23 PM ON EVENT_063 Safety chain

HAWA28 2/14/2024 4:49:29 PM ON EVENT_057 Incorrect generator-rotor speed ratio


HAWA28 2/14/2024 4:49:29 PM ON EVENT_129 Generator speed not plausible
HAWA28 2/14/2024 4:51:35 PM OFF EVENT_129 Generator speed not plausible
HAWA28 2/14/2024 4:53:43 PM ON EVENT_055 Rotor speed sensor failure
HAWA28 2/14/2024 4:53:43 PM ON EVENT_014 Generator overspeed

HAWA28 2/14/2024 4:53:43 PM ON EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/14/2024 5:25:47 PM ON EVENT_273 Manual or service time excessive


HAWA28 2/14/2024 5:39:19 PM OFF EVENT_1202 Contactor or Breaker
HAWA28 2/14/2024 5:39:19 PM OFF EVENT_1233 DC Link under-voltage
HAWA28 2/14/2024 5:39:19 PM OFF EVENT_1201 Blown Fuses
HAWA28 2/14/2024 5:39:19 PM OFF EVENT_1253 Ground Fault, Rotor
HAWA28 2/14/2024 5:39:19 PM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/14/2024 5:40:18 PM OFF EVENT_063 Safety chain

HAWA28 2/14/2024 5:40:18 PM OFF EVENT_057 Incorrect generator-rotor speed ratio


HAWA28 2/14/2024 5:40:18 PM OFF EVENT_014 Generator overspeed

HAWA28 2/14/2024 5:40:18 PM OFF EVENT_055 Rotor speed sensor failure


HAWA28 2/14/2024 5:42:35 PM OFF EVENT_1511 Generator Over Speed Opened Safety Chain

HAWA28 2/14/2024 5:42:37 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/14/2024 5:42:42 PM ON EVENT_144 Blade angle asymmetry


HAWA28 2/14/2024 5:43:01 PM OFF EVENT_144 Blade angle asymmetry
HAWA28 2/14/2024 5:43:01 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/14/2024 6:44:11 PM ON EVENT_120 Pitch controller communications fault


HAWA28 2/14/2024 6:44:11 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA28 2/14/2024 6:44:11 PM ON EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/14/2024 6:44:11 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 96 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/14/2024 6:44:11 PM ON EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/14/2024 6:44:11 PM ON EVENT_009 Undervoltage


HAWA28 2/14/2024 6:44:11 PM ON EVENT_116 Grid voltage fault
HAWA28 2/14/2024 6:44:11 PM ON EVENT_1242 Grid Loss
HAWA28 2/14/2024 6:44:11 PM ON EVENT_1209 HSSL / HSLA, Line converter
HAWA28 2/14/2024 6:44:11 PM ON EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/14/2024 6:44:13 PM ON EVENT_001 Program start PLC
HAWA28 2/14/2024 6:44:19 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 6:44:19 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 6:44:19 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 6:44:19 PM ON EVENT_179 Successful Emergency Break System Test


Needed
HAWA28 2/14/2024 6:44:29 PM OFF EVENT_001 Program start PLC
HAWA28 2/14/2024 6:46:13 PM OFF EVENT_120 Pitch controller communications fault
HAWA28 2/14/2024 6:49:14 PM ON EVENT_133 Batteries Charging
HAWA28 2/14/2024 7:37:06 PM OFF EVENT_133 Batteries Charging
HAWA28 2/14/2024 7:51:41 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 7:51:41 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 7:51:41 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 7:51:41 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 7:51:41 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 7:51:41 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 7:51:42 PM OFF EVENT_1209 HSSL / HSLA, Line converter


HAWA28 2/14/2024 7:51:42 PM OFF EVENT_1210 HSSL / HSLA, Rotor converter
HAWA28 2/14/2024 7:51:43 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 7:51:43 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 7:51:43 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 7:51:44 PM ON EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 7:51:44 PM ON EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 7:51:44 PM ON EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 7:52:24 PM OFF EVENT_009 Undervoltage


HAWA28 2/14/2024 7:52:24 PM OFF EVENT_116 Grid voltage fault
HAWA28 2/14/2024 7:52:24 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

WindSCADA 11.0 SP9.0 Page 97 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA28 2/14/2024 7:52:24 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA28 2/14/2024 7:52:24 PM OFF EVENT_1504 Dta Estop Opened Safety Chain

HAWA28 2/14/2024 7:52:31 PM OFF EVENT_213 Battery voltage not OK axis 2

HAWA28 2/14/2024 7:52:31 PM OFF EVENT_214 Battery voltage not OK axis 3

HAWA28 2/14/2024 7:52:31 PM OFF EVENT_212 Battery voltage not OK axis 1

HAWA28 2/14/2024 7:52:32 PM OFF EVENT_1517 Cu Grid Monitor Opened Safety Chain

HAWA28 2/14/2024 7:52:32 PM OFF EVENT_1242 Grid Loss


HAWA28 2/14/2024 7:52:32 PM ON EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/14/2024 7:52:40 PM OFF EVENT_275 Pitch Converter not ready axis 2

HAWA28 2/14/2024 8:04:54 PM ON EVENT_383 Uncontrol battery test active


HAWA28 2/14/2024 8:04:54 PM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA28 2/14/2024 8:06:33 PM OFF EVENT_383 Uncontrol battery test active
HAWA28 2/14/2024 8:06:44 PM ON EVENT_006 System OK
HAWA29 2/4/2024 5:40:37 AM ON EVENT_1201 Blown Fuses
HAWA29 2/4/2024 5:40:37 AM OFF EVENT_006 System OK
HAWA29 2/4/2024 5:40:38 AM ON EVENT_116 Grid voltage fault
HAWA29 2/4/2024 5:40:39 AM ON EVENT_009 Undervoltage
HAWA29 2/4/2024 5:40:50 AM ON EVENT_1242 Grid Loss
HAWA29 2/4/2024 5:45:37 AM ON EVENT_133 Batteries Charging
HAWA29 2/4/2024 5:46:02 AM ON EVENT_449 Pitch rate deviation axis 3
HAWA29 2/4/2024 5:46:02 AM OFF EVENT_133 Batteries Charging
HAWA29 2/4/2024 5:46:02 AM ON EVENT_447 Pitch rate deviation axis 1
HAWA29 2/4/2024 5:46:02 AM ON EVENT_448 Pitch rate deviation axis 2
HAWA29 2/4/2024 5:46:03 AM ON EVENT_345 Battery drive after grid fault
HAWA29 2/4/2024 5:46:03 AM ON EVENT_388 Communication fault pitch controller Axis 3
HAWA29 2/4/2024 5:46:03 AM ON EVENT_386 Communication fault pitch controller Axis 1
HAWA29 2/4/2024 5:46:03 AM ON EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 5:46:03 AM OFF EVENT_345 Battery drive after grid fault
HAWA29 2/4/2024 5:46:03 AM OFF EVENT_388 Communication fault pitch controller Axis 3
HAWA29 2/4/2024 5:46:03 AM OFF EVENT_386 Communication fault pitch controller Axis 1
HAWA29 2/4/2024 5:46:07 AM ON EVENT_358 Malfunction Triplepitch System

HAWA29 2/4/2024 5:46:07 AM ON EVENT_578 Malfunction Triplepitch System Axis 3

HAWA29 2/4/2024 5:46:07 AM ON EVENT_577 Malfunction Triplepitch System Axis 2

HAWA29 2/4/2024 5:46:07 AM ON EVENT_179 Successful Emergency Break System Test


Needed

WindSCADA 11.0 SP9.0 Page 98 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA29 2/4/2024 11:21:14 AM ON EVENT_120 Pitch controller communications fault


HAWA29 2/4/2024 11:21:14 AM ON EVENT_179 Successful Emergency Break System Test
Needed
HAWA29 2/4/2024 11:21:14 AM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 11:21:14 AM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 11:21:15 AM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 11:21:15 AM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 11:21:16 AM ON EVENT_001 Program start PLC


HAWA29 2/4/2024 11:21:22 AM OFF EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 11:21:33 AM OFF EVENT_001 Program start PLC
HAWA29 2/4/2024 11:26:13 AM ON EVENT_383 Uncontrol battery test active
HAWA29 2/4/2024 11:26:13 AM OFF EVENT_179 Successful Emergency Break System Test
Needed
HAWA29 2/4/2024 11:27:24 AM OFF EVENT_383 Uncontrol battery test active
HAWA29 2/4/2024 11:27:24 AM ON EVENT_567 Emergency Brake System Test required axis
3
HAWA29 2/4/2024 11:27:24 AM ON EVENT_565 Emergency Brake System Test required axis
1
HAWA29 2/4/2024 11:27:24 AM ON EVENT_566 Emergency Brake System Test required axis
2
HAWA29 2/4/2024 11:27:24 AM ON EVENT_006 System OK
HAWA29 2/4/2024 11:27:24 AM OFF EVENT_006 System OK
HAWA29 2/4/2024 11:27:36 AM ON EVENT_124 Pitch Overrun 0deg
HAWA29 2/4/2024 11:27:50 AM OFF EVENT_124 Pitch Overrun 0deg
HAWA29 2/4/2024 11:27:54 AM ON EVENT_144 Blade angle asymmetry
HAWA29 2/4/2024 11:28:00 AM OFF EVENT_144 Blade angle asymmetry
HAWA29 2/4/2024 11:32:24 AM ON EVENT_383 Uncontrol battery test active
HAWA29 2/4/2024 11:32:24 AM OFF EVENT_567 Emergency Brake System Test required axis
3
HAWA29 2/4/2024 11:32:24 AM OFF EVENT_565 Emergency Brake System Test required axis
1
HAWA29 2/4/2024 11:32:24 AM OFF EVENT_566 Emergency Brake System Test required axis
2
HAWA29 2/4/2024 11:34:04 AM OFF EVENT_383 Uncontrol battery test active
HAWA29 2/4/2024 11:34:04 AM ON EVENT_006 System OK
HAWA29 2/4/2024 11:39:47 AM ON EVENT_1201 Blown Fuses
HAWA29 2/4/2024 11:39:47 AM OFF EVENT_006 System OK
HAWA29 2/4/2024 11:40:13 AM OFF EVENT_1201 Blown Fuses
HAWA29 2/4/2024 11:40:20 AM ON EVENT_006 System OK
HAWA29 2/4/2024 11:43:10 AM ON EVENT_1201 Blown Fuses
HAWA29 2/4/2024 11:43:10 AM OFF EVENT_006 System OK
HAWA29 2/4/2024 11:44:08 AM OFF EVENT_1201 Blown Fuses

WindSCADA 11.0 SP9.0 Page 99 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA29 2/4/2024 11:44:08 AM ON EVENT_006 System OK


HAWA29 2/4/2024 11:46:38 AM ON EVENT_1201 Blown Fuses
HAWA29 2/4/2024 11:46:38 AM OFF EVENT_006 System OK
HAWA29 2/4/2024 12:18:45 PM OFF EVENT_1201 Blown Fuses
HAWA29 2/4/2024 12:18:55 PM ON EVENT_116 Grid voltage fault
HAWA29 2/4/2024 12:18:55 PM ON EVENT_009 Undervoltage
HAWA29 2/4/2024 12:19:01 PM ON EVENT_1218 Power Supply
HAWA29 2/4/2024 12:19:01 PM ON EVENT_367 CCU fault at abnormal grid condition
HAWA29 2/4/2024 12:26:33 PM ON EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 12:26:33 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 12:26:33 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 12:26:33 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 12:26:33 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 12:26:34 PM ON EVENT_001 Program start PLC


HAWA29 2/4/2024 12:26:40 PM OFF EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 12:26:47 PM OFF EVENT_001 Program start PLC
HAWA29 2/4/2024 12:27:37 PM ON EVENT_006 System OK
HAWA29 2/4/2024 12:33:06 PM ON EVENT_1201 Blown Fuses
HAWA29 2/4/2024 12:33:06 PM OFF EVENT_006 System OK
HAWA29 2/4/2024 2:17:11 PM ON EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 2:17:11 PM ON EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 2:17:11 PM ON EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 2:17:11 PM ON EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA29 2/4/2024 2:17:11 PM ON EVENT_907 Yaw Brake Voltage 230Volt not OK


HAWA29 2/4/2024 2:17:11 PM OFF EVENT_1506 Yaw Cable Limit Switch Opened Safety Chain

HAWA29 2/4/2024 2:17:11 PM OFF EVENT_1503 IFM Sensor Opened Safety Chain

HAWA29 2/4/2024 2:17:11 PM OFF EVENT_1507 Top Box Estop Active Opened Safety Chain

HAWA29 2/4/2024 2:17:13 PM ON EVENT_001 Program start PLC


HAWA29 2/4/2024 2:17:19 PM OFF EVENT_120 Pitch controller communications fault
HAWA29 2/4/2024 2:17:29 PM OFF EVENT_001 Program start PLC
HAWA29 2/4/2024 2:20:18 PM OFF EVENT_907 Yaw Brake Voltage 230Volt not OK
HAWA29 2/4/2024 2:23:04 PM ON EVENT_006 System OK
HAWA29 2/6/2024 6:00:11 AM ON EVENT_383 Uncontrol battery test active
HAWA29 2/6/2024 6:00:11 AM OFF EVENT_006 System OK
HAWA29 2/6/2024 6:01:51 AM OFF EVENT_383 Uncontrol battery test active

WindSCADA 11.0 SP9.0 Page 100 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Event Log
Start Time:1/31/2024 End Time:2/19/2024

HAWA29 2/6/2024 6:01:51 AM ON EVENT_006 System OK


HAWA29 2/13/2024 4:59:45 AM ON EVENT_383 Uncontrol battery test active
HAWA29 2/13/2024 4:59:45 AM OFF EVENT_006 System OK
HAWA29 2/13/2024 5:01:10 AM ON EVENT_157 Secondary rotor brake does not close
HAWA29 2/13/2024 5:01:47 AM OFF EVENT_383 Uncontrol battery test active
HAWA29 2/13/2024 5:02:21 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA29 2/13/2024 5:02:27 AM ON EVENT_006 System OK
HAWA29 2/15/2024 11:54:12 AM ON EVENT_157 Secondary rotor brake does not close
HAWA29 2/15/2024 11:54:12 AM OFF EVENT_006 System OK
HAWA29 2/15/2024 11:54:45 AM OFF EVENT_157 Secondary rotor brake does not close
HAWA29 2/15/2024 11:54:48 AM ON EVENT_006 System OK

CCU Event details:

Events EVENT_104, EVENT_105, EVENT_106, EVENT_107, EVENT_112, EVENT_113, EVENT_114, EVENT_115, EVENT_141, EVENT_14

WindSCADA 11.0 SP9.0 Page 101 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Category Event Type Power Wind Speed Gen. Speed CCU
(kW) (m/s) (Rpm) Event

e User fault 124 4.7 1032 No


No Fault OFF 124 4.7 1032 No
s not close Brake Fault -12 5.6 21 No
e User fault -17 4.0 0 No
s not close Brake Fault -9 2.8 0 No
No Fault ON -9 4.1 0 No
Unused Fault 0 5.2 1079 No
ver Frequency Grid Fault 0 5.2 1079 No
No Fault OFF 0 5.2 1079 No
Grid Fault 0 5.2 1079 No
Grid Fault 0 5.2 1079 No
Unused Fault 0 5.2 1079 No
Unused Fault 0 2.4 436 No
t Pitch Fault 0 3.2 317 No
Pitch Fault 0 3.2 317 No
No Fault Fault 0 7.5 9 No
No Fault Fault 0 8.5 9 No
controller Axis 3 Misc Fault 0 8.0 8 No
controller Axis 1 Misc Fault 0 8.0 8 No
tions fault Pitch Fault 0 8.0 8 No
controller Axis 3 Misc Fault 0 8.0 8 No
controller Axis 1 Misc Fault 0 8.0 8 No
tions fault Pitch Fault -8 11.9 8 No
ened Safety Chain Multiple Safety Critical fault -8 11.9 8 No

Chain Multiple Safety Critical fault -8 11.9 8 No

ened Safety Chain Multiple Safety Critical fault -8 11.9 8 No

Chain Multiple Safety Critical fault -8 11.9 8 No

Misc Fault -6 13.7 12 No


tions fault Pitch Fault -7 11.8 13 No
Misc Fault -7 11.8 25 No
No Fault ON -7 11.8 25 No
s not close Brake Fault -7 2.5 1048 No

WindSCADA 11.0 SP9.0 Page 102 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault OFF -7 2.5 1048 No
s not close Brake Fault -6 5.0 18 No
No Fault ON -6 4.7 15 No
e User fault -8 4.7 54 No
No Fault OFF -8 4.7 54 No
s not close Brake Fault -8 3.8 12 No
e User fault -9 4.7 0 No
s not close Brake Fault -9 3.7 0 No
No Fault ON -8 3.6 0 No
e User fault 124 6.0 1030 No
No Fault OFF 124 6.0 1030 No
s not close Brake Fault -6 5.3 15 No
e User fault -6 5.0 0 No
s not close Brake Fault -7 3.1 7 No
No Fault ON -7 4.5 8 No
e User fault 102 3.9 1030 No
No Fault OFF 102 3.9 1030 No
e User fault -6 3.7 0 No
No Fault ON -6 3.7 0 No
Unused Fault 273 4.8 1102 No
ver Frequency Grid Fault 273 4.8 1102 No
No Fault OFF 273 4.8 1102 No
Grid Fault 273 4.8 1102 No
Grid Fault 273 4.8 1102 No
Unused Fault 273 4.8 1102 No
Unused Fault 0 5.7 413 No
No Fault Fault 0 8.1 16 No
User Fault 0 6.4 0 No
No Fault Fault 0 5.6 0 No
User Fault 0 5.6 0 No
User Fault 0 5.6 0 No
t Pitch Fault 0 5.6 0 No
controller Axis 1 Misc Fault 0 5.6 0 No
controller Axis 3 Misc Fault 0 5.5 0 No
t Pitch Fault 0 5.5 0 No
controller Axis 3 Misc Fault 0 5.5 0 No
controller Axis 1 Misc Fault 0 5.5 0 No
tions fault Pitch Fault 0 5.5 0 No
tem Pitch Safety Critical fault 0 4.7 2 No

WindSCADA 11.0 SP9.0 Page 103 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tem Axis 3 Pitch Safety Critical fault 0 4.7 2 No

tem Axis 2 Pitch Safety Critical fault 0 4.7 2 No

ak System Test Pitch Safety Critical fault 0 4.7 2 No

tions fault Pitch Fault -6 14.9 25 No


ak System Test Pitch Safety Critical fault -6 14.9 25 No

ened Safety Chain Multiple Safety Critical fault -6 14.9 25 No

Chain Multiple Safety Critical fault -6 14.9 25 No

ened Safety Chain Multiple Safety Critical fault -6 14.9 25 No

Chain Multiple Safety Critical fault -6 14.9 25 No

Misc Fault -6 13.8 26 No


tions fault Pitch Fault -7 13.4 15 No
Misc Fault -8 12.9 30 No
e User fault -3 10.9 21 No
ak System Test Pitch Safety Critical fault -3 10.9 21 No

e User fault -4 10.5 0 No


Test required axis Pitch Safety Critical fault -4 10.5 0 No

Test required axis Pitch Safety Critical fault -4 10.5 0 No

Test required axis Pitch Safety Critical fault -4 10.5 0 No

No Fault ON -4 10.5 0 No
No Fault OFF -4 10.5 0 No
Pitch Fault -6 12.0 6 No
Pitch Fault -3 10.1 25 No
Pitch Fault -3 9.9 18 No
Pitch Fault -6 6.9 0 No
e User fault -2 8.4 3 No
Test required axis Pitch Safety Critical fault -2 8.4 3 No

Test required axis Pitch Safety Critical fault -2 8.4 3 No

Test required axis Pitch Safety Critical fault -2 8.4 3 No

e User fault -8 6.9 0 No


No Fault ON -8 6.9 0 No
Unused Fault -18 10.0 1039 No
No Fault OFF -18 10.0 1039 No
Unused Fault -3 10.9 28 No

WindSCADA 11.0 SP9.0 Page 104 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault ON -5 11.5 35 No
e User fault -3 8.2 32 No
No Fault OFF -3 8.2 32 No
e User fault -7 12.4 0 No
No Fault ON -20 11.5 0 No
e User fault 132 6.9 1061 No
No Fault OFF 132 6.9 1061 No
e User fault -7 8.2 0 No
No Fault ON -7 8.2 0 No
Grid Fault -146 5.9 1053 No
No Fault OFF -146 5.9 1053 No
Grid Fault -146 5.9 1053 No
Unused Fault -15 5.5 1069 No
condition Grid Fault -15 5.5 1069 No
Grid Fault 0 5.5 1041 No
Unused Fault 0 8.0 272 No
No Fault Fault 0 6.6 21 No
User Fault 0 5.7 7 No
No Fault Fault 0 5.7 7 No
User Fault 0 5.7 7 No
User Fault 0 5.7 7 No
t Pitch Fault 0 4.0 6 No
controller Axis 1 Misc Fault 0 4.0 6 No
controller Axis 3 Misc Fault 0 4.0 6 No
tions fault Pitch Fault 0 4.0 6 No
t Pitch Fault 0 4.0 6 No
controller Axis 3 Misc Fault 0 4.0 6 No
controller Axis 1 Misc Fault 0 4.0 6 No
tem Pitch Safety Critical fault 0 4.6 4 No

tem Axis 3 Pitch Safety Critical fault 0 4.6 4 No

tem Axis 2 Pitch Safety Critical fault 0 4.6 4 No

ak System Test Pitch Safety Critical fault 0 4.6 4 No

tions fault Pitch Fault 0 4.2 0 No


ak System Test Pitch Safety Critical fault 0 4.2 0 No

ened Safety Chain Multiple Safety Critical fault 0 4.2 0 No

Chain Multiple Safety Critical fault 0 4.2 0 No

WindSCADA 11.0 SP9.0 Page 105 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Fault 0 4.2 0 No
Grid Fault 0 4.2 0 No
Grid Fault 0 4.2 0 No
condition Grid Fault 0 4.2 0 No
ault Frequency Fault 0 4.2 0 No
Converter
Misc Fault 0 5.0 0 No
s2 Pitch Safety Critical fault 0 6.2 0 No

s3 Pitch Safety Critical fault 0 6.2 0 No

s1 Pitch Safety Critical fault 0 6.2 0 No

Misc Fault 0 5.7 0 No


tions fault Pitch Fault 0 8.8 0 No
hain Multiple Safety Critical fault 0 9.3 0 No

Grid Fault 0 11.2 0 No


s2 Pitch Safety Critical fault 0 11.2 0 No

s3 Pitch Safety Critical fault 0 11.2 0 No

s1 Pitch Safety Critical fault 0 11.2 0 No

s2 Pitch Safety Critical fault 0 10.5 0 No

s3 Pitch Safety Critical fault 0 10.5 0 No

s1 Pitch Safety Critical fault 0 10.5 0 No

tions fault Pitch Fault 0 12.0 0 No


ak System Test Pitch Safety Critical fault 0 12.0 0 No

ened Safety Chain Multiple Safety Critical fault 0 12.0 0 No

Chain Multiple Safety Critical fault 0 12.0 0 No

hain Multiple Safety Critical fault 0 12.0 0 No

Grid Fault 0 12.0 0 No


Grid Fault 0 12.0 0 No
condition Grid Fault 0 12.0 0 No
ault Frequency Fault 0 12.0 0 No
Converter
Misc Fault 0 13.7 0 No
s2 Pitch Safety Critical fault 0 13.3 0 No

s3 Pitch Safety Critical fault 0 13.3 0 No

WindSCADA 11.0 SP9.0 Page 106 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
s1 Pitch Safety Critical fault 0 13.3 0 No

Misc Fault 0 12.7 0 No


tions fault Pitch Fault 0 9.8 0 No
ak System Test Pitch Safety Critical fault 0 9.8 0 No

ened Safety Chain Multiple Safety Critical fault 0 9.8 0 No

Chain Multiple Safety Critical fault 0 9.8 0 No

hain Multiple Safety Critical fault 0 9.8 0 No

Grid Fault 0 9.8 0 No


Grid Fault 0 9.8 0 No
condition Grid Fault 0 9.8 0 No
ault Frequency Fault 0 9.8 0 No
Converter
Misc Fault 0 10.6 0 No
s2 Pitch Safety Critical fault 0 10.5 0 No

s3 Pitch Safety Critical fault 0 10.5 0 No

s1 Pitch Safety Critical fault 0 10.5 0 No

Misc Fault 0 12.0 0 No


tions fault Pitch Fault 0 9.4 0 No
ault Frequency Fault -2 8.6 0 No
Converter
condition Grid Fault -2 8.5 0 No
Grid Fault -5 8.9 0 No
Grid Fault -5 8.9 0 No
ened Safety Chain Multiple Safety Critical fault -5 8.9 0 No

Chain Multiple Safety Critical fault -5 8.9 0 No

hain Multiple Safety Critical fault -5 8.9 0 No

axis 1 Pitch Safety Critical fault -4 8.1 0 No

axis 2 Pitch Safety Critical fault -4 8.1 0 No

axis 3 Pitch Safety Critical fault -4 8.1 0 No

s not close Brake Fault -5 7.5 0 No


s2 Pitch Safety Critical fault -5 7.2 0 No

s3 Pitch Safety Critical fault -5 7.2 0 No

s1 Pitch Safety Critical fault -5 7.2 0 No

WindSCADA 11.0 SP9.0 Page 107 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
s2 Pitch Safety Critical fault -5 7.2 0 No

s3 Pitch Safety Critical fault -5 7.2 0 No

s1 Pitch Safety Critical fault -5 7.2 0 No

s2 Pitch Safety Critical fault -5 10.8 0 No

s3 Pitch Safety Critical fault -5 10.8 0 No

s1 Pitch Safety Critical fault -5 10.8 0 No

axis 1 Pitch Safety Critical fault -5 10.8 0 No

axis 2 Pitch Safety Critical fault -5 10.8 0 No

axis 3 Pitch Safety Critical fault -5 10.8 0 No

s not close Brake Fault -5 5.3 0 No


e User fault -5 7.5 13 No
ak System Test Pitch Safety Critical fault -5 7.5 13 No

e User fault -7 8.0 0 No


Test required axis Pitch Safety Critical fault -7 8.0 0 No

Test required axis Pitch Safety Critical fault -7 8.0 0 No

Test required axis Pitch Safety Critical fault -7 8.0 0 No

Pitch Fault -8 9.6 0 No


Pitch Fault -3 8.8 0 No
e User fault -2 9.1 18 No
Test required axis Pitch Safety Critical fault -2 9.1 18 No

Test required axis Pitch Safety Critical fault -2 9.1 18 No

Test required axis Pitch Safety Critical fault -2 9.1 18 No

e User fault -4 10.8 0 No


No Fault ON -4 9.8 9 No
e User fault 119 3.9 1041 No
No Fault OFF 119 3.9 1041 No
e User fault -8 7.2 51 No
No Fault ON -8 7.2 51 No
e User fault 216 7.6 1061 No
No Fault OFF 216 7.6 1061 No
er Unused Fault -10 9.5 0 No
ter Unused Fault -10 9.5 0 No
failed or Misc Fault -11 8.4 0 No

WindSCADA 11.0 SP9.0 Page 108 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
e User fault -10 6.9 0 No
failed or Misc Fault -5 14.7 12 No
er Unused Fault -18 13.8 11 No
ter Unused Fault -18 13.8 11 No
er Unused Fault -6 10.8 38 No
failed or Misc Fault -6 10.8 38 No
ter Unused Fault -13 8.9 37 No
failed or Misc Fault -2 10.8 27 No
er Unused Fault -25 10.1 25 No
ter Unused Fault -25 10.1 25 No
No Fault ON -3 7.0 28 No
er Unused Fault 132 9.0 1070 No
ter Unused Fault 132 9.0 1070 No
No Fault OFF 132 9.0 1070 No
failed or Misc Fault -22 7.6 1079 No
cessive User Fault -1 11.5 15 No
tions fault Pitch Fault -16 14.3 0 No
ened Safety Chain Multiple Safety Critical fault -16 14.3 0 No

Chain Multiple Safety Critical fault -16 14.3 0 No

ed Safety Chain Multiple Safety Critical fault -16 14.3 0 No

ened Safety Chain Multiple Safety Critical fault -16 14.3 0 No

Chain Multiple Safety Critical fault -16 14.3 0 No

ed Safety Chain Multiple Safety Critical fault -16 14.3 0 No

Misc Fault -8 14.7 0 No


tions fault Pitch Fault -9 12.0 0 No
Misc Fault -9 14.3 0 No
No Fault ON -5 12.3 0 No
Unused Fault -23 11.2 1066 No
Unused Fault -23 11.2 1066 No
No Fault OFF -23 11.2 1066 No
Multiple Safety Critical fault -23 11.2 1066 No

tions fault Pitch Fault 0 12.7 0 No


ened Safety Chain Multiple Safety Critical fault 0 12.7 0 No

Chain Multiple Safety Critical fault 0 12.7 0 No

ed Safety Chain Multiple Safety Critical fault 0 12.7 0 No

WindSCADA 11.0 SP9.0 Page 109 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Grid Fault 0 12.7 0 No
Grid Fault 0 12.7 0 No
condition Grid Fault 0 12.7 0 No
ault Frequency Fault 0 12.7 0 No
Converter
Misc Fault 0 10.9 0 No
Misc Fault 0 13.3 0 No
ault Frequency Fault 0 15.7 0 No
Converter
condition Grid Fault -1 15.2 0 No
Grid Fault -1 14.8 0 No
Grid Fault -1 14.8 0 No
ened Safety Chain Multiple Safety Critical fault -1 14.8 0 No

Chain Multiple Safety Critical fault -1 14.8 0 No

ed Safety Chain Multiple Safety Critical fault -1 14.8 0 No

tions fault Pitch Fault -5 13.7 0 No


No Fault ON -5 11.9 0 No
e User fault 117 4.9 1030 No
No Fault OFF 117 4.9 1030 No
e User fault -7 5.6 0 No
No Fault ON -7 5.6 0 No
Grid Fault -137 5.2 1060 No
No Fault OFF 0 5.8 1071 No
Unused Fault 0 5.8 1071 No
Grid Fault 0 5.8 1071 No
Unused Fault 0 5.3 318 No
No Fault Fault 0 5.7 24 No
User Fault 0 8.2 11 No
No Fault Fault 0 8.2 11 No
User Fault 0 7.6 12 No
t Pitch Fault 0 7.6 12 No
User Fault 0 7.6 12 No
controller Axis 1 Misc Fault 0 7.6 12 No
controller Axis 3 Misc Fault 0 6.7 9 No
controller Axis 3 Misc Fault 0 6.7 9 No
controller Axis 1 Misc Fault 0 6.7 9 No
tions fault Pitch Fault 0 6.7 9 No
t Pitch Fault 0 6.7 9 No
tem Pitch Safety Critical fault 0 7.1 5 No

WindSCADA 11.0 SP9.0 Page 110 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tem Axis 3 Pitch Safety Critical fault 0 7.1 5 No

tem Axis 2 Pitch Safety Critical fault 0 7.1 5 No

ak System Test Pitch Safety Critical fault 0 7.1 5 No

tions fault Pitch Fault -6 14.4 22 No


ak System Test Pitch Safety Critical fault -6 14.4 22 No

ened Safety Chain Multiple Safety Critical fault -6 14.4 22 No

Chain Multiple Safety Critical fault -6 14.4 22 No

ened Safety Chain Multiple Safety Critical fault -6 14.4 22 No

Chain Multiple Safety Critical fault -6 14.4 22 No

Misc Fault -6 13.3 16 No


tions fault Pitch Fault -7 14.4 26 No
Misc Fault -8 11.2 35 No
e User fault -3 9.6 16 No
ak System Test Pitch Safety Critical fault -4 7.9 19 No

e User fault -5 8.0 0 No


Test required axis Pitch Safety Critical fault -5 8.0 0 No

Test required axis Pitch Safety Critical fault -5 8.0 0 No

Test required axis Pitch Safety Critical fault -5 8.0 0 No

No Fault ON -5 8.0 0 No
No Fault OFF -5 8.0 0 No
Pitch Fault -3 8.8 19 No
Pitch Fault -3 9.0 25 No
Pitch Fault -3 6.6 7 No
Pitch Fault -3 7.2 7 No
e User fault -2 10.0 28 No
Test required axis Pitch Safety Critical fault -2 10.0 28 No

Test required axis Pitch Safety Critical fault -2 10.0 28 No

Test required axis Pitch Safety Critical fault -2 10.0 28 No

e User fault -3 10.0 0 No


No Fault ON -3 10.0 0 No
g time too long Brake Safety Critical fault -7 5.2 97 No

No Fault OFF -7 5.2 97 No

WindSCADA 11.0 SP9.0 Page 111 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
g time too long Brake Safety Critical fault -1 3.6 9 No

No Fault ON -2 5.0 13 No
e User fault -10 7.7 31 No
No Fault OFF -10 7.7 31 No
e User fault -9 8.2 0 No
No Fault ON -9 8.2 0 No
e User fault -13 7.7 31 No
No Fault OFF -13 7.7 31 No
e User fault -4 5.7 0 No
No Fault ON -4 5.7 0 No
e User fault -5 5.5 27 No
No Fault OFF -5 5.5 27 No
e User fault -6 4.5 0 No
No Fault ON -6 4.5 0 No
Grid Fault 87 5.1 1044 No
No Fault OFF 87 5.1 1044 No
Unused Fault -15 6.0 1057 No
Grid Fault 0 5.6 1028 No
Unused Fault 0 7.0 276 No
No Fault Fault 0 6.6 14 No
User Fault 0 4.7 10 No
t Pitch Fault 0 6.4 10 No
controller Axis 2 Misc Fault 0 6.4 10 No
tem Axis 2 Pitch Safety Critical fault 0 3.1 12 No

ak System Test Pitch Safety Critical fault 0 3.1 12 No

No Fault Fault 0 4.8 8 No


controller Axis 1 Misc Fault 0 4.8 7 No
t Pitch Fault 0 4.8 7 No
tions fault Pitch Fault 0 4.8 7 No
controller Axis 2 Misc Fault 0 4.8 7 No
controller Axis 1 Misc Fault 0 4.8 7 No
Unused Fault 0 6.1 5 No
Multiple Safety Critical fault 0 6.1 5 No

tions fault Pitch Fault -6 9.6 5 No


ak System Test Pitch Safety Critical fault -6 9.6 5 No

ened Safety Chain Multiple Safety Critical fault -6 9.6 5 No

WindSCADA 11.0 SP9.0 Page 112 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Chain Multiple Safety Critical fault -6 9.6 5 No

ened Safety Chain Multiple Safety Critical fault -6 9.6 5 No

Chain Multiple Safety Critical fault -6 9.6 5 No

Misc Fault -7 9.4 4 No


tions fault Pitch Fault -7 10.8 9 No
axis 1 Pitch Safety Critical fault -28 8.0 10 No

Pitch Fault -8 8.9 4 No


Misc Fault -7 9.8 8 No
Pitch Fault -7 9.8 8 No
axis 1 Pitch Safety Critical fault -5 8.5 28 No

e User fault -3 12.7 26 No


ak System Test Pitch Safety Critical fault -3 12.7 26 No

e User fault -8 11.8 0 No


Test required axis Pitch Safety Critical fault -8 11.8 0 No

Test required axis Pitch Safety Critical fault -8 11.8 0 No

Test required axis Pitch Safety Critical fault -8 11.8 0 No

No Fault ON -8 11.8 0 No
No Fault OFF -8 11.8 0 No
Pitch Fault -8 10.5 0 No
Pitch Fault -3 12.7 0 No
e User fault -2 9.0 5 No
Test required axis Pitch Safety Critical fault -2 9.0 5 No

Test required axis Pitch Safety Critical fault -2 9.0 5 No

Test required axis Pitch Safety Critical fault -2 9.0 5 No

e User fault -3 11.9 0 No


No Fault ON -3 11.9 0 No
e User fault -18 8.0 31 No
No Fault OFF -18 8.0 31 No
s not close Brake Fault -6 8.1 9 No
e User fault -16 8.6 0 No
s not close Brake Fault -2 8.1 19 No
No Fault ON -2 8.4 26 No
e User fault -29 4.8 15 No
No Fault OFF -29 4.8 15 No

WindSCADA 11.0 SP9.0 Page 113 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
s not close Brake Fault -7 5.1 8 No
e User fault -3 7.6 0 No
s not close Brake Fault -3 7.1 9 No
No Fault ON -7 8.2 14 No
s not close Brake Fault -30 3.9 1049 No
No Fault OFF -30 3.9 1049 No
s not close Brake Fault -7 5.8 21 No
No Fault ON -7 5.5 23 No
e User fault 302 6.7 1139 No
No Fault OFF 302 6.7 1139 No
e User fault -17 6.1 0 No
No Fault ON -17 6.1 0 No
Unused Fault 2 5.9 1139 No
ver Frequency Grid Fault 2 5.9 1139 No
No Fault OFF 2 5.9 1139 No
Grid Fault 2 5.9 1139 No
Grid Fault 2 5.9 1139 No
Unused Fault 2 5.9 1139 No
Unused Fault 0 2.4 510 No
No Fault Fault 0 7.9 11 No
User Fault 0 5.7 13 No
controller Axis 2 Misc Fault 0 5.1 9 No
t Pitch Fault 0 5.1 9 No
tem Axis 2 Pitch Safety Critical fault 0 5.1 3 No

ak System Test Pitch Safety Critical fault 0 5.1 3 No

No Fault Fault 0 5.7 4 No


controller Axis 1 Misc Fault 0 6.2 1 No
controller Axis 2 Misc Fault 0 5.0 0 No
tions fault Pitch Fault 0 5.0 0 No
t Pitch Fault 0 5.0 0 No
controller Axis 1 Misc Fault 0 5.0 0 No
Unused Fault 0 7.5 9 No
Multiple Safety Critical fault 0 7.5 9 No

Multiple Fault 0 7.5 9 No


ened Safety Chain Multiple Safety Critical fault 0 7.5 9 No

Chain Multiple Safety Critical fault 0 7.5 9 No

er Unused Fault 0 7.5 9 No

WindSCADA 11.0 SP9.0 Page 114 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault 0 7.5 9 No
Converter
tions fault Pitch Fault -8 12.7 14 No
ak System Test Pitch Safety Critical fault -8 12.7 14 No

ened Safety Chain Multiple Safety Critical fault -8 12.7 14 No

Chain Multiple Safety Critical fault -8 12.7 14 No

ened Safety Chain Multiple Safety Critical fault -6 12.4 16 No

Chain Multiple Safety Critical fault -6 12.4 16 No

Misc Fault -7 11.8 16 No


tions fault Pitch Fault -7 11.8 22 No
axis 1 Pitch Safety Critical fault -7 10.5 22 No

axis 2 Pitch Safety Critical fault -7 10.5 22 No

Pitch Fault -7 11.9 19 No


Misc Fault -7 11.4 22 No
Pitch Fault -7 11.4 22 No
axis 1 Pitch Safety Critical fault -7 11.7 29 No

axis 2 Pitch Safety Critical fault -7 11.7 29 No

e User fault -3 7.6 33 No


ak System Test Pitch Safety Critical fault -3 7.6 33 No

e User fault -6 11.8 60 No


Test required axis Pitch Safety Critical fault -6 11.8 60 No

Test required axis Pitch Safety Critical fault -6 11.8 60 No

Test required axis Pitch Safety Critical fault -6 11.8 60 No

No Fault ON -6 11.8 60 No
No Fault OFF -6 11.8 60 No
Pitch Fault -5 10.8 50 No
Pitch Fault -4 11.0 47 No
Pitch Fault -5 10.1 22 No
Pitch Fault -10 10.5 17 No
e User fault -2 10.1 34 No
Test required axis Pitch Safety Critical fault -2 10.1 34 No

Test required axis Pitch Safety Critical fault -2 10.1 34 No

Test required axis Pitch Safety Critical fault -2 10.1 34 No

WindSCADA 11.0 SP9.0 Page 115 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
e User fault -3 8.2 0 No
No Fault ON -3 8.2 0 No
e User fault -5 7.7 32 No
No Fault OFF -6 7.7 32 No
e User fault -6 7.2 0 No
No Fault ON -6 7.2 0 No
ter Unused Fault 84 7.6 1057 No
No Fault OFF -13 7.6 1067 No
ter Unused Fault -6 10.4 46 No
No Fault ON -6 8.2 47 No
Unused Fault -10 3.1 1036 No
Unused Fault -10 3.1 1036 No
ter Unused Fault -10 3.1 1036 No
Unused Fault -10 3.1 1036 No
Unused Fault -10 3.1 1036 No
No Fault OFF -10 3.1 1036 No
Multiple Safety Critical fault -10 3.1 1036 No

ned Safety Chain Multiple Safety Critical fault -10 3.1 1036 No

cessive User Fault -2 6.0 0 No


tions fault Pitch Fault -8 5.2 0 No
ened Safety Chain Multiple Safety Critical fault -8 5.2 0 No

Chain Multiple Safety Critical fault -8 5.2 0 No

ed Safety Chain Multiple Safety Critical fault -8 5.2 0 No

ened Safety Chain Multiple Safety Critical fault -36 7.4 0 No

Chain Multiple Safety Critical fault -36 7.4 0 No

ed Safety Chain Multiple Safety Critical fault -36 7.4 0 No

Misc Fault -7 8.4 0 No


tions fault Pitch Fault -8 8.9 0 No
e low axis 1 Pitch Safety Critical fault -16 8.5 0 No

e low axis 2 Pitch Safety Critical fault -16 8.5 0 No

Pitch Fault -8 8.6 0 No


Misc Fault -8 8.2 0 No
Pitch Fault -8 8.2 0 No
e low axis 1 Pitch Safety Critical fault -12 7.6 0 No

WindSCADA 11.0 SP9.0 Page 116 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
e low axis 2 Pitch Safety Critical fault -12 7.6 0 No

afety Chain Multiple Safety Critical fault -5 5.8 0 No

Grid Fault -5 5.8 0 No


Grid Fault -5 5.8 0 No
condition Grid Fault -5 5.8 0 No
ault Frequency Fault -5 5.8 0 No
Converter
ault Frequency Fault 0 6.1 0 No
Converter
condition Grid Fault -1 7.7 0 No
Grid Fault -1 6.7 0 No
Grid Fault -1 6.7 0 No
afety Chain Multiple Safety Critical fault -4 7.9 0 No

No Fault ON -5 7.1 0 No
e User fault -11 6.4 23 No
No Fault OFF -11 6.4 23 No
e User fault -3 6.4 0 No
No Fault ON -3 6.4 0 No
ter Unused Fault -2 6.5 29 No
No Fault OFF -2 6.5 29 No
ter Unused Fault -2 7.5 22 No
No Fault ON -7 6.0 24 No
ter Unused Fault 242 4.2 1030 No
No Fault OFF 242 4.2 1030 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Unused Fault -12 3.7 771 No
Multiple Safety Critical fault -12 3.7 771 No

ned Safety Chain Multiple Safety Critical fault -12 3.7 771 No

cessive User Fault -5 5.5 0 No


Multiple Fault -2 0.0 0 No
ed Safety Chain Multiple Safety Critical fault -2 0.0 0 No

ened Safety Chain Multiple Safety Critical fault -2 0.0 0 No

Chain Multiple Safety Critical fault -2 0.0 0 No

Multiple Safety Critical fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 117 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
r speed Frequency Fault -2 0.0 0 No
Converter
r speed Frequency Fault -2 0.0 0 No
Converter
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
ure Sensor Fault Fault -2 0.0 0 No
re Azimuth Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
ter Unused Fault -2 0.0 0 No
tions fault Pitch Fault -2 0.0 0 No
ure Sensor Fault Fault -2 3.1 0 No
re Azimuth Fault -2 3.1 0 No
tions fault Pitch Fault -2 3.1 0 No
tection alarm Frequency Fault -2 3.1 0 No
Converter
failed or Misc Fault -2 3.1 0 No
tection alarm Frequency Fault -2 3.1 0 No
Converter
failed or Misc Fault -2 3.1 0 No
ure Sensor Fault Fault -2 3.1 0 No
re Azimuth Fault -2 3.1 0 No
tions fault Pitch Fault -2 0.0 0 No
Multiple Fault -6 4.3 0 No
ure Sensor Fault Fault -6 4.3 0 No
re Azimuth Fault -6 4.3 0 No
tions fault Pitch Fault -6 4.3 0 No
tection alarm Frequency Fault -6 4.3 0 No
Converter
failed or Misc Fault -6 4.3 0 No
ened Safety Chain Multiple Safety Critical fault -6 4.3 0 No

Chain Multiple Safety Critical fault -6 4.3 0 No

ed Safety Chain Multiple Safety Critical fault -6 4.3 0 No

ned Safety Chain Multiple Safety Critical fault -6 4.3 0 No

axis 1 Pitch Safety Critical fault -10 4.7 0 No

axis 2 Pitch Safety Critical fault -10 4.7 0 No

WindSCADA 11.0 SP9.0 Page 118 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
ades Pitch Safety Critical fault -6 4.3 0 No

afety Chain Multiple Safety Critical fault -6 4.3 0 No

Grid Fault -6 4.3 0 No


Multiple Fault -6 4.3 0 No
t Pitch Fault -6 4.3 0 No
ed Safety Chain Multiple Safety Critical fault -6 4.3 0 No

ened Safety Chain Multiple Safety Critical fault -6 4.3 0 No

Chain Multiple Safety Critical fault -6 4.3 0 No

ades Pitch Safety Critical fault -6 4.3 0 No

axis 1 Pitch Safety Critical fault -6 4.3 0 No

axis 2 Pitch Safety Critical fault -6 4.3 0 No

t Pitch Fault -6 4.3 0 No


Grid Fault -6 4.3 0 No
condition Grid Fault -6 4.3 0 No
ault Frequency Fault -6 4.3 0 No
Converter
tection alarm Frequency Fault -6 4.3 0 No
Converter
protection alarm Frequency Fault -6 4.3 0 No
Converter
ure Sensor Fault Fault - - - No
re Azimuth Fault - - - No
tions fault Pitch Fault - - - No
Unused Fault - - - No
ault Frequency Fault - - - No
Converter
condition Grid Fault -3 3.4 0 No
Grid Fault -3 3.3 0 No
Grid Fault -3 3.3 0 No
tions fault Pitch Fault -7 4.3 0 No
tection alarm Frequency Fault -7 4.3 0 No
Converter
protection alarm Frequency Fault -7 4.3 0 No
Converter
Multiple Fault -7 2.7 0 No
ure Sensor Fault Fault -7 2.7 0 No
re Azimuth Fault -7 2.7 0 No
ened Safety Chain Multiple Safety Critical fault -7 2.7 0 No

afety Chain Multiple Safety Critical fault -7 2.7 0 No

WindSCADA 11.0 SP9.0 Page 119 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Chain Multiple Safety Critical fault -7 2.7 0 No

ed Safety Chain Multiple Safety Critical fault -7 2.7 0 No

Unused Fault -23 3.2 0 No


Grid Fault 0 4.6 0 No
Grid Fault 0 4.6 0 No
Unused Fault 0 2.9 0 No
condition Grid Fault 0 2.9 0 No
Unused Fault 0 3.3 0 No
Unused Fault 0 5.1 10 No
Multiple Safety Critical fault 0 5.1 10 No

Multiple Fault 0 5.1 10 No


er Unused Fault 0 5.1 10 No
ened Safety Chain Multiple Safety Critical fault 0 5.1 10 No

Chain Multiple Safety Critical fault 0 5.1 10 No

ter Unused Fault 0 5.1 10 No


tection alarm Frequency Fault 0 0.0 10 No
Converter
tions fault Pitch Fault 0 3.7 0 No
ened Safety Chain Multiple Safety Critical fault 0 3.7 0 No

Chain Multiple Safety Critical fault 0 3.7 0 No

Grid Fault 0 3.7 0 No


Grid Fault 0 3.7 0 No
Unused Fault 0 3.7 0 No
ened Safety Chain Multiple Safety Critical fault 0 3.7 0 No

Chain Multiple Safety Critical fault 0 3.7 0 No

Misc Fault 0 3.6 0 No


s2 Pitch Safety Critical fault 0 3.6 0 No

s3 Pitch Safety Critical fault 0 3.6 0 No

s1 Pitch Safety Critical fault 0 3.6 0 No

ak System Test Pitch Safety Critical fault 0 3.6 0 No

Misc Fault 0 5.0 0 No


tions fault Pitch Fault 0 2.9 0 No
axis 3 Pitch Safety Critical fault 0 3.1 0 No

t Pitch Fault 0 3.1 0 No

WindSCADA 11.0 SP9.0 Page 120 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
axis 1 Pitch Safety Critical fault 0 3.1 0 No

Unused Fault 0 7.5 4 No


ked WTG Opened Multiple Safety Critical fault 0 6.0 28 No

s2 Pitch Safety Critical fault 0 6.4 0 No

s3 Pitch Safety Critical fault 0 6.4 0 No

s1 Pitch Safety Critical fault 0 6.4 0 No

axis 1 Pitch Safety Critical fault 0 6.4 0 No

axis 3 Pitch Safety Critical fault 0 6.4 0 No

ked WTG Opened Multiple Safety Critical fault 0 6.4 0 No

t Pitch Fault 0 6.4 0 No


s2 Pitch Safety Critical fault 0 6.4 0 No

s3 Pitch Safety Critical fault 0 6.4 0 No

s1 Pitch Safety Critical fault 0 6.4 0 No

Unused Fault 0 5.1 0 No


axis 1 Pitch Safety Critical fault 0 5.6 0 No

axis 2 Pitch Safety Critical fault 0 5.6 0 No

axis 3 Pitch Safety Critical fault 0 5.6 0 No

t Pitch Fault 0 5.6 0 No


Multiple Fault 0 4.3 0 No
Multiple Safety Critical fault 0 4.3 0 No

ened Safety Chain Multiple Safety Critical fault 0 4.3 0 No

Chain Multiple Safety Critical fault 0 4.3 0 No

tection alarm Frequency Fault 0 4.3 0 No


Converter
ure Sensor Fault Fault 0 0.0 0 No
re Azimuth Fault 0 0.0 0 No
tions fault Pitch Fault 0 0.0 0 No
n Brake Fault 0 0.0 0 No
ure from thermal Gearbox Fault 0 0.0 0 No
ulator pressure Brake Fault 0 0.0 0 No
Misc Fault 0 0.0 0 No
tions fault Pitch Fault 0 0.0 0 No
failed or Misc Fault -3 0.0 0 No

WindSCADA 11.0 SP9.0 Page 121 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Multiple Safety Critical fault -2 0.0 0 No

Grid Fault -2 0.0 0 No


Grid Fault -2 0.0 0 No
n Brake Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
s2 Pitch Safety Critical fault -2 0.0 0 No

s3 Pitch Safety Critical fault -2 0.0 0 No

t Pitch Fault -2 0.0 0 No


s1 Pitch Safety Critical fault -2 0.0 0 No

tection alarm Frequency Fault -2 0.0 0 No


Converter
failed or Misc Fault -2 0.0 0 No
axis 1 Pitch Safety Critical fault -2 0.0 0 No

axis 2 Pitch Safety Critical fault -2 0.0 0 No

axis 3 Pitch Safety Critical fault -2 0.0 0 No

Misc Fault -2 0.0 0 No


tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Unused Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter

WindSCADA 11.0 SP9.0 Page 122 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 123 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
hain Multiple Safety Critical fault -2 0.0 0 No

Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 124 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
n Brake Fault -2 0.0 0 No
n Brake Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 125 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
n Brake Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter

WindSCADA 11.0 SP9.0 Page 126 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 127 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -3 0.0 0 No
Converter
failed or Misc Fault -3 0.0 0 No
tection alarm Frequency Fault -3 0.0 0 No
Converter
failed or Misc Fault -3 0.0 0 No
tection alarm Frequency Fault -8 4.8 0 No
Converter
failed or Misc Fault -8 4.8 0 No
n Brake Fault -9 6.2 0 No
Misc Fault -9 6.2 0 No
Multiple Fault -9 6.2 0 No
ure Sensor Fault Fault -9 6.2 0 No
ure from thermal Gearbox Fault -9 6.2 0 No
re Azimuth Fault -9 6.2 0 No
ened Safety Chain Multiple Safety Critical fault -9 6.2 0 No

Chain Multiple Safety Critical fault -9 6.2 0 No

hain Multiple Safety Critical fault -9 6.2 0 No

Misc Fault -9 6.2 0 No


Misc Fault -7 6.9 0 No
axis 1 Pitch Safety Critical fault -7 6.9 0 No

axis 2 Pitch Safety Critical fault -7 6.9 0 No

Misc Fault -7 6.9 0 No


Misc Fault -7 6.9 0 No

WindSCADA 11.0 SP9.0 Page 128 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Misc Fault -8 7.2 0 No
axis 1 Pitch Safety Critical fault -8 4.5 0 No

axis 2 Pitch Safety Critical fault -8 4.5 0 No

Misc Fault -7 3.4 0 No


Misc Fault -7 4.0 0 No
Misc Fault -7 3.2 0 No
Misc Fault -7 3.2 0 No
Misc Fault -7 5.1 0 No
Misc Fault -7 4.8 0 No
ulator pressure Brake Fault -7 6.4 0 No
e User fault -6 7.1 0 No
ak System Test Pitch Safety Critical fault -6 7.1 0 No

e User fault -7 6.1 0 No


Unused Fault -7 5.5 0 No
Misc Fault -7 6.7 3 No
Misc Fault -7 7.1 4 No
Unused Fault -7 7.1 4 No
Misc Fault -2 5.7 0 No
Misc Fault -2 5.7 0 No
Unused Fault -2 7.0 4 No
Misc Fault -2 4.8 10 No
Misc Fault -3 5.8 1 No
Misc Fault -2 6.0 10 No
Unused Fault -3 4.0 0 No
No Fault ON -2 3.6 0 No
Unused Fault -3 6.2 13 No
No Fault OFF -3 6.2 13 No
Unused Fault -10 5.3 15 No
No Fault ON -10 5.3 15 No
Unused Fault -2 4.8 20 No
No Fault OFF -2 4.8 20 No
Unused Fault -3 5.3 5 No
No Fault ON -3 5.3 5 No
Unused Fault -3 5.3 5 No
No Fault OFF -3 5.3 5 No
Unused Fault -3 5.2 9 No
No Fault ON -3 5.2 9 No
Unused Fault -15 5.5 16 No

WindSCADA 11.0 SP9.0 Page 129 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault OFF -15 5.5 16 No
tions fault Pitch Fault -8 8.6 0 No
ened Safety Chain Multiple Safety Critical fault -8 8.6 0 No

Chain Multiple Safety Critical fault -8 8.6 0 No

hain Multiple Safety Critical fault -8 8.6 0 No

ed Safety Chain Multiple Safety Critical fault -8 8.6 0 No

Misc Fault -6 7.7 0 No


tions fault Pitch Fault -6 5.3 0 No
ened Safety Chain Multiple Safety Critical fault -7 5.0 0 No

Chain Multiple Safety Critical fault -7 5.0 0 No

hain Multiple Safety Critical fault -7 5.0 0 No

ed Safety Chain Multiple Safety Critical fault -7 5.0 0 No

Misc Fault -7 5.0 0 No


No Fault ON -5 5.6 0 No
Grid Fault -1 5.0 17 No
No Fault OFF -1 5.0 17 No
Grid Fault -1 5.0 17 No
Unused Fault 0 5.7 10 No
condition Grid Fault 0 5.7 10 No
cessive User Fault 0 5.6 10 No
Unused Fault 0 7.9 0 No
condition Grid Fault -10 7.6 2 No
Grid Fault -3 7.9 2 No
Grid Fault -3 7.9 2 No
Unused Fault -3 7.2 2 No
Unused Fault -3 7.2 2 No
ed Safety Chain Multiple Safety Critical fault -4 7.7 0 No

Multiple Fault -2 8.6 0 No


ened Safety Chain Multiple Safety Critical fault -2 8.6 0 No

Chain Multiple Safety Critical fault -2 8.6 0 No

tection alarm Frequency Fault -2 8.6 0 No


Converter
failed or Misc Fault -2 0.0 0 No
ure Sensor Fault Fault -2 0.0 0 No
re Azimuth Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 130 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tions fault Pitch Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
n Brake Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tions fault Pitch Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
ure from thermal Gearbox Fault -2 0.0 0 No
ulator pressure Brake Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No

WindSCADA 11.0 SP9.0 Page 131 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 0.0 0 No
Converter
failed or Misc Fault -2 0.0 0 No
tection alarm Frequency Fault -2 7.0 0 No
Converter
failed or Misc Fault -2 7.0 0 No
n Brake Fault -2 8.2 0 No
Multiple Fault -2 8.2 0 No
ure Sensor Fault Fault -2 8.2 0 No
ure from thermal Gearbox Fault -2 8.2 0 No
re Azimuth Fault -2 8.2 0 No
ened Safety Chain Multiple Safety Critical fault -4 7.9 0 No

Chain Multiple Safety Critical fault -4 7.9 0 No

ed Safety Chain Multiple Safety Critical fault -4 7.9 0 No

ulator pressure Brake Fault -5 7.5 0 No


tions fault Pitch Fault -6 6.2 0 No
ened Safety Chain Multiple Safety Critical fault -6 6.2 0 No

Chain Multiple Safety Critical fault -6 6.2 0 No

hain Multiple Safety Critical fault -6 6.2 0 No

Misc Fault -6 8.0 0 No


Misc Fault -6 7.7 0 No
tions fault Pitch Fault -6 7.7 0 No
ened Safety Chain Multiple Safety Critical fault -6 6.5 0 No

Chain Multiple Safety Critical fault -6 6.5 0 No

hain Multiple Safety Critical fault -6 6.5 0 No

WindSCADA 11.0 SP9.0 Page 132 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault ON -5 9.4 0 No
No Fault OFF 261 6.5 1030 No
No Fault ON -5 7.0 24 No
Unused Fault -14 8.4 125 No
Unused Fault -14 8.4 125 No
Unused Fault -14 8.4 125 No
Unused Fault -14 8.4 125 No
ter Unused Fault -14 8.4 125 No
No Fault OFF -14 8.4 125 No
Multiple Safety Critical fault -14 8.4 125 No

peed ratio Sensor Fault Fault -10 5.7 0 No


ble Sensor Fault Fault -10 5.7 0 No
ble Sensor Fault Fault -4 5.7 0 No
Sensor Fault Fault -15 4.4 66607 No
Multiple Safety Critical fault -15 4.4 66607 No

ned Safety Chain Multiple Safety Critical fault -15 4.4 66607 No

cessive User Fault -2 6.9 0 No


Unused Fault -2 6.9 0 No
Unused Fault -2 6.9 0 No
Unused Fault -2 6.9 0 No
Unused Fault -2 6.9 0 No
ter Unused Fault -2 6.9 0 No
Multiple Safety Critical fault -2 8.6 0 No

peed ratio Sensor Fault Fault -2 8.6 0 No


Multiple Safety Critical fault -2 8.6 0 No

Sensor Fault Fault -2 8.6 0 No


ned Safety Chain Multiple Safety Critical fault -2 6.7 0 No

axis 2 Pitch Safety Critical fault -2 7.6 0 No

Pitch Fault -2 7.0 0 No


Pitch Fault -2 6.0 0 No
axis 2 Pitch Safety Critical fault -2 6.0 0 No

tions fault Pitch Fault 0 5.8 0 No


ened Safety Chain Multiple Safety Critical fault 0 5.8 0 No

afety Chain Multiple Safety Critical fault 0 5.8 0 No

Chain Multiple Safety Critical fault 0 5.8 0 No

WindSCADA 11.0 SP9.0 Page 133 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
hain Multiple Safety Critical fault 0 5.8 0 No

Grid Fault 0 5.8 0 No


Grid Fault 0 5.8 0 No
Unused Fault 0 5.8 0 No
er Unused Fault 0 5.8 0 No
ter Unused Fault 0 5.8 0 No
Misc Fault 0 7.4 0 No
s2 Pitch Safety Critical fault 0 5.8 0 No

s3 Pitch Safety Critical fault 0 5.8 0 No

s1 Pitch Safety Critical fault 0 5.8 0 No

ak System Test Pitch Safety Critical fault 0 5.8 0 No

Misc Fault 0 4.5 0 No


tions fault Pitch Fault 0 6.1 0 No
No Fault Fault 0 6.6 0 No
No Fault Fault 0 4.6 0 No
s2 Pitch Safety Critical fault 0 6.9 0 No

s3 Pitch Safety Critical fault 0 6.9 0 No

s1 Pitch Safety Critical fault 0 6.9 0 No

s2 Pitch Safety Critical fault 0 6.9 0 No

s3 Pitch Safety Critical fault 0 6.9 0 No

s1 Pitch Safety Critical fault 0 6.9 0 No

er Unused Fault 0 6.7 0 No


ter Unused Fault 0 6.7 0 No
s2 Pitch Safety Critical fault 0 5.2 0 No

s3 Pitch Safety Critical fault 0 5.2 0 No

s1 Pitch Safety Critical fault 0 5.2 0 No

s2 Pitch Safety Critical fault 0 4.6 0 No

s3 Pitch Safety Critical fault 0 4.6 0 No

s1 Pitch Safety Critical fault 0 4.6 0 No

Grid Fault -3 8.0 0 No


Grid Fault -3 8.0 0 No
ened Safety Chain Multiple Safety Critical fault -3 8.0 0 No

WindSCADA 11.0 SP9.0 Page 134 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
Chain Multiple Safety Critical fault -3 8.0 0 No

hain Multiple Safety Critical fault -3 8.0 0 No

s2 Pitch Safety Critical fault -8 6.5 0 No

s3 Pitch Safety Critical fault -8 6.5 0 No

s1 Pitch Safety Critical fault -8 6.5 0 No

afety Chain Multiple Safety Critical fault -12 6.4 0 No

Unused Fault -12 6.4 0 No


axis 2 Pitch Safety Critical fault -12 6.4 0 No

axis 2 Pitch Safety Critical fault -8 5.5 0 No

e User fault -4 4.5 7 No


ak System Test Pitch Safety Critical fault -4 4.5 7 No

e User fault -4 8.4 0 No


No Fault ON -4 6.9 4 No
Unused Fault -97 5.8 1052 No
No Fault OFF -97 5.8 1052 No
Grid Fault -14 6.0 1080 No
Grid Fault 0 5.5 1043 No
Unused Fault 0 8.2 271 No
No Fault Fault 0 7.1 15 No
User Fault 0 6.7 1 No
No Fault Fault 0 6.7 1 No
User Fault 0 6.7 1 No
User Fault 0 6.7 1 No
t Pitch Fault 0 6.7 2 No
controller Axis 3 Misc Fault 0 6.7 2 No
controller Axis 1 Misc Fault 0 6.7 2 No
tions fault Pitch Fault 0 6.7 2 No
t Pitch Fault 0 6.7 2 No
controller Axis 3 Misc Fault 0 6.7 2 No
controller Axis 1 Misc Fault 0 6.7 2 No
tem Pitch Safety Critical fault 0 6.2 2 No

tem Axis 3 Pitch Safety Critical fault 0 6.2 2 No

tem Axis 2 Pitch Safety Critical fault 0 6.2 2 No

ak System Test Pitch Safety Critical fault 0 6.2 2 No

WindSCADA 11.0 SP9.0 Page 135 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
tions fault Pitch Fault -8 8.8 9 No
ak System Test Pitch Safety Critical fault -8 8.8 9 No

ened Safety Chain Multiple Safety Critical fault -8 8.8 9 No

Chain Multiple Safety Critical fault -8 8.8 9 No

ened Safety Chain Multiple Safety Critical fault -7 7.9 9 No

Chain Multiple Safety Critical fault -7 7.9 9 No

Misc Fault -7 9.1 11 No


tions fault Pitch Fault -8 11.5 24 No
Misc Fault -8 10.3 30 No
e User fault -4 8.9 33 No
ak System Test Pitch Safety Critical fault -4 8.9 33 No

e User fault -5 11.5 0 No


Test required axis Pitch Safety Critical fault -5 11.5 0 No

Test required axis Pitch Safety Critical fault -5 11.5 0 No

Test required axis Pitch Safety Critical fault -5 11.5 0 No

No Fault ON -5 11.5 0 No
No Fault OFF -5 11.5 0 No
Pitch Fault -3 12.8 0 No
Pitch Fault -3 12.4 19 No
Pitch Fault -3 11.7 18 No
Pitch Fault -3 9.8 0 No
e User fault -2 7.5 24 No
Test required axis Pitch Safety Critical fault -2 7.5 24 No

Test required axis Pitch Safety Critical fault -2 7.5 24 No

Test required axis Pitch Safety Critical fault -2 7.5 24 No

e User fault -3 7.0 0 No


No Fault ON -3 7.0 0 No
Unused Fault -6 7.4 1047 No
No Fault OFF -6 7.4 1047 No
Unused Fault -6 9.8 39 No
No Fault ON -5 12.4 28 No
Unused Fault -5 8.9 1043 No
No Fault OFF -5 8.9 1043 No
Unused Fault -4 8.6 37 No

WindSCADA 11.0 SP9.0 Page 136 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault ON -4 8.6 37 No
Unused Fault -6 9.5 1059 No
No Fault OFF -6 9.5 1059 No
Unused Fault -2 8.9 50 No
Grid Fault 0 11.2 0 No
Grid Fault 0 11.2 0 No
Unused Fault 0 8.2 0 No
condition Grid Fault 0 8.2 0 No
tions fault Pitch Fault -10 12.3 0 No
ened Safety Chain Multiple Safety Critical fault -10 12.3 0 No

Chain Multiple Safety Critical fault -10 12.3 0 No

ened Safety Chain Multiple Safety Critical fault -10 12.3 0 No

Chain Multiple Safety Critical fault -10 12.3 0 No

Misc Fault -4 11.5 0 No


tions fault Pitch Fault -5 10.0 0 No
Misc Fault -6 9.6 0 No
No Fault ON -5 11.0 1 No
Unused Fault -5 10.1 1054 No
No Fault OFF -5 10.1 1054 No
tions fault Pitch Fault -8 7.9 0 No
ened Safety Chain Multiple Safety Critical fault -8 7.9 0 No

Chain Multiple Safety Critical fault -8 7.9 0 No

ed Safety Chain Multiple Safety Critical fault -8 7.9 0 No

not OK Misc Fault -8 7.9 0 No


ened Safety Chain Multiple Safety Critical fault -8 7.9 0 No

Chain Multiple Safety Critical fault -8 7.9 0 No

ed Safety Chain Multiple Safety Critical fault -8 7.9 0 No

Misc Fault -7 8.9 0 No


tions fault Pitch Fault -8 9.4 0 No
Misc Fault -9 9.0 0 No
not OK Misc Fault -5 11.0 0 No
No Fault ON -4 6.6 0 No
e User fault -5 8.1 36 No
No Fault OFF -5 8.1 36 No
e User fault -6 6.7 0 No

WindSCADA 11.0 SP9.0 Page 137 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
No Fault ON -6 6.7 0 No
e User fault 94 4.8 1050 No
No Fault OFF 94 4.8 1050 No
s not close Brake Fault -6 9.3 17 No
e User fault -6 6.4 0 No
s not close Brake Fault -6 6.9 14 No
No Fault ON -6 7.9 12 No
s not close Brake Fault -6 2.9 1051 No
No Fault OFF -6 2.9 1051 No
s not close Brake Fault -5 4.5 34 No
No Fault ON -5 4.3 24 No

5, EVENT_141, EVENT_142, EVENT_286, EVENT_100015

WindSCADA 11.0 SP9.0 Page 138 By: PKHAWA\\control_room


HAWA At:2/19/2024 10:31:04 AM
HAWA01 2/4/2024 5:40:37 AM 2/4/2024 11:24:14 AM Grid voltage fault
HAWA01 2/5/2024 5:53:05 AM 2/5/2024 5:58:37 AM Uncontrol battery test active
HAWA01 2/9/2024 5:00:00 AM 2/9/2024 5:02:03 AM Uncontrol battery test active
HAWA01 2/16/2024 4:00:01 AM 2/16/2024 4:01:42 AM Uncontrol battery test active
HAWA02 2/1/2024 12:10:16 PM 2/1/2024 12:56:15 PM Power Supply
HAWA02 2/4/2024 5:40:37 AM 2/4/2024 11:22:26 AM Grid voltage fault
HAWA02 2/4/2024 1:38:09 PM 2/4/2024 1:40:20 PM Uncontrol battery test active
HAWA02 2/11/2024 12:38:25 PM 2/11/2024 12:40:34 PM Uncontrol battery test active
HAWA02 2/18/2024 11:38:41 AM 2/18/2024 11:40:47 AM Uncontrol battery test active
HAWA03 1/31/2024 10:56:01 AM 1/31/2024 10:57:39 AM Uncontrol battery test active
HAWA03 2/4/2024 5:40:37 AM 2/4/2024 11:22:51 AM Grid voltage fault
HAWA03 2/5/2024 12:40:25 AM 2/5/2024 12:42:33 AM Secondary rotor brake does not close
HAWA03 2/5/2024 2:33:35 AM 2/5/2024 2:35:43 AM Secondary rotor brake does not close
HAWA03 2/6/2024 6:49:10 PM 2/7/2024 3:30:53 AM Blade angle asymmetry
HAWA03 2/13/2024 10:52:49 PM 2/13/2024 10:54:58 PM Uncontrol battery test active
HAWA04 2/3/2024 11:15:13 AM 2/3/2024 11:17:35 AM Uncontrol battery test active
HAWA04 2/3/2024 11:17:45 AM 2/3/2024 11:18:50 AM Pitch control deviation Axis 3
HAWA04 2/3/2024 11:19:16 AM 2/3/2024 11:22:35 AM Battery voltage not OK axis 3
HAWA04 2/3/2024 11:24:00 AM 2/3/2024 6:20:18 PM Battery voltage not OK axis 2
HAWA04 2/4/2024 5:40:37 AM 2/4/2024 11:22:18 AM Grid voltage fault
HAWA04 2/10/2024 4:37:21 PM 2/10/2024 4:39:30 PM Uncontrol battery test active
HAWA04 2/17/2024 3:37:37 PM 2/17/2024 3:39:49 PM Uncontrol battery test active
HAWA05 2/2/2024 3:08:49 AM 2/2/2024 3:10:56 AM Uncontrol battery test active
HAWA05 2/4/2024 5:40:37 AM 2/4/2024 10:58:26 AM Grid voltage fault
HAWA05 2/8/2024 2:46:54 PM 2/8/2024 10:54:02 PM Stopped for Pitch Batteries Replacement activity
HAWA05 2/9/2024 5:00:00 AM 2/9/2024 5:02:02 AM Uncontrol battery test active
HAWA05 2/16/2024 4:00:01 AM 2/16/2024 4:02:02 AM Uncontrol battery test active
HAWA06 2/1/2024 3:27:27 PM 2/1/2024 7:01:31 PM Stopped for Pitch Batteries Replacement activity
HAWA06 2/2/2024 5:00:00 AM 2/2/2024 5:01:41 AM Uncontrol battery test active
HAWA06 2/4/2024 5:40:37 AM 2/4/2024 11:35:32 AM Grid voltage fault
HAWA06 2/6/2024 6:01:22 AM 2/6/2024 6:03:01 AM Uncontrol battery test active
HAWA06 2/13/2024 5:01:53 AM 2/13/2024 5:03:32 AM Uncontrol battery test active
HAWA07 2/4/2024 5:40:37 AM 2/4/2024 11:33:54 AM Grid voltage fault
HAWA07 2/5/2024 12:12:34 AM 2/5/2024 12:13:09 AM Secondary rotor brake does not close
HAWA07 2/6/2024 6:01:32 AM 2/6/2024 6:03:11 AM Uncontrol battery test active
HAWA07 2/13/2024 5:01:53 AM 2/13/2024 5:03:32 AM Uncontrol battery test active
HAWA08 2/4/2024 5:40:37 AM 2/4/2024 11:22:13 AM Grid voltage fault
HAWA08 2/5/2024 12:17:54 AM 2/5/2024 12:18:57 AM Secondary rotor brake does not close
HAWA08 2/5/2024 3:11:34 AM 2/5/2024 3:12:34 AM Secondary rotor brake does not close
HAWA08 2/6/2024 9:04:01 PM 2/6/2024 9:07:27 PM Uncontrol battery test active
HAWA08 2/13/2024 8:04:17 PM 2/13/2024 8:06:20 PM Uncontrol battery test active
HAWA08 2/13/2024 8:06:20 PM 2/13/2024 8:08:01 PM Uncontrol battery test active
HAWA08 2/13/2024 8:10:48 PM 2/13/2024 8:13:06 PM Batteries Charging
HAWA09 2/2/2024 3:00:17 AM 2/2/2024 3:03:27 AM Uncontrol battery test active
HAWA09 2/4/2024 5:40:37 AM 2/4/2024 11:20:15 AM Grid voltage fault
HAWA09 2/9/2024 2:00:33 AM 2/9/2024 2:02:29 AM Uncontrol battery test active
HAWA09 2/10/2024 10:30:27 AM 2/10/2024 4:34:03 PM Pitch Batteries Replacement activity.
HAWA09 2/17/2024 3:03:29 PM 2/17/2024 3:05:32 PM Uncontrol battery test active
HAWA10 2/4/2024 5:40:37 AM 2/4/2024 11:20:21 AM Grid voltage fault
HAWA10 2/5/2024 5:10:25 AM 2/5/2024 5:12:33 AM Uncontrol battery test active
HAWA10 2/6/2024 6:00:19 AM 2/6/2024 6:01:59 AM Uncontrol battery test active
HAWA10 2/13/2024 4:59:45 AM 2/13/2024 5:01:27 AM Uncontrol battery test active
HAWA11 2/4/2024 5:40:37 AM 2/4/2024 11:34:55 AM Grid voltage fault
HAWA11 2/6/2024 6:00:30 AM 2/6/2024 6:02:09 AM Uncontrol battery test active
HAWA11 2/13/2024 4:59:45 AM 2/13/2024 5:01:24 AM Uncontrol battery test active
HAWA12 2/2/2024 4:05:01 AM 2/2/2024 4:09:04 AM Uncontrol battery test active
HAWA12 2/4/2024 5:40:37 AM 2/4/2024 11:20:09 AM Grid voltage fault
HAWA12 2/5/2024 3:23:06 AM 2/5/2024 3:24:23 AM Secondary rotor brake does not close
HAWA12 2/9/2024 3:04:33 AM 2/9/2024 3:06:36 AM Uncontrol battery test active
HAWA12 2/16/2024 2:04:49 AM 2/16/2024 2:07:22 AM Uncontrol battery test active
HAWA13 2/1/2024 1:07:09 PM 2/1/2024 1:32:03 PM Power Supply
HAWA13 2/4/2024 5:40:37 AM 2/4/2024 10:41:20 AM Grid voltage fault
HAWA13 2/5/2024 5:04:01 AM 2/5/2024 5:06:04 AM Uncontrol battery test active
HAWA13 2/6/2024 6:00:51 AM 2/6/2024 6:02:31 AM Uncontrol battery test active
HAWA13 2/13/2024 4:59:45 AM 2/13/2024 5:01:24 AM Uncontrol battery test active
HAWA14 2/2/2024 3:00:17 AM 2/2/2024 3:02:22 AM Uncontrol battery test active
HAWA14 2/4/2024 5:40:37 AM 2/4/2024 11:32:50 AM Grid voltage fault
HAWA14 2/6/2024 6:01:02 AM 2/6/2024 6:02:43 AM Uncontrol battery test active
HAWA14 2/13/2024 4:59:45 AM 2/13/2024 5:01:25 AM Uncontrol battery test active
HAWA15 1/31/2024 5:25:21 AM 1/31/2024 5:27:00 AM Uncontrol battery test active
HAWA15 2/1/2024 1:56:54 PM 2/1/2024 2:15:41 PM Power Supply
HAWA15 2/4/2024 5:40:37 AM 2/4/2024 11:03:37 AM Grid voltage fault
HAWA15 2/4/2024 2:10:24 PM 2/4/2024 3:02:02 PM Severe Blade Problems indicating pitch runaway condition in axis 2
HAWA15 2/11/2024 1:59:29 PM 2/11/2024 2:01:34 PM Uncontrol battery test active
HAWA15 2/18/2024 12:59:45 PM 2/18/2024 1:01:42 PM Uncontrol battery test active
HAWA16 2/4/2024 5:40:37 AM 2/4/2024 11:21:48 AM Grid voltage fault
HAWA16 2/5/2024 5:59:29 AM 2/5/2024 6:01:35 AM Uncontrol battery test active
HAWA16 2/6/2024 6:01:23 AM 2/6/2024 6:03:02 AM Uncontrol battery test active
HAWA16 2/13/2024 5:01:53 AM 2/13/2024 5:03:33 AM Uncontrol battery test active
HAWA17 2/3/2024 8:17:05 PM 2/3/2024 8:19:14 PM Uncontrol battery test active
HAWA17 2/4/2024 5:40:37 AM 2/4/2024 11:34:24 AM Grid voltage fault
HAWA17 2/6/2024 6:01:33 AM 2/6/2024 6:03:13 AM Uncontrol battery test active
HAWA17 2/13/2024 5:01:53 AM 2/13/2024 5:03:33 AM Uncontrol battery test active
HAWA18 2/3/2024 2:22:54 PM 2/3/2024 8:58:11 PM Yaw Brake Voltage 230Volt not OK
HAWA18 2/4/2024 2:09:07 AM 2/4/2024 5:40:37 AM Yaw Brake Voltage 230Volt not OK
HAWA18 2/4/2024 5:40:37 AM 2/4/2024 11:24:27 AM Grid voltage fault
HAWA18 2/4/2024 11:28:29 AM 2/4/2024 11:29:36 AM Yaw Cable Limit Switch Opened Safety Chain
HAWA18 2/5/2024 3:09:23 PM 2/5/2024 3:16:11 PM Yaw Cable Limit Switch Opened Safety Chain
HAWA18 2/5/2024 3:19:56 PM 2/6/2024 4:04:32 AM Yaw Brake Voltage 230Volt not OK
HAWA18 2/10/2024 5:28:33 PM 2/10/2024 5:30:40 PM Uncontrol battery test active
HAWA18 2/17/2024 4:28:49 PM 2/17/2024 4:30:55 PM Uncontrol battery test active
HAWA19 2/1/2024 3:21:40 AM 2/1/2024 3:22:12 AM Power Supply
HAWA19 2/1/2024 10:13:51 AM 2/1/2024 10:46:30 AM Power Supply
HAWA19 2/4/2024 5:40:37 AM 2/4/2024 11:23:39 AM Grid voltage fault
HAWA19 2/6/2024 11:47:13 AM 2/6/2024 11:49:19 AM Uncontrol battery test active
HAWA19 2/13/2024 10:47:29 AM 2/13/2024 10:49:12 AM Uncontrol battery test active
HAWA20 2/2/2024 2:00:33 AM 2/2/2024 2:02:14 AM Uncontrol battery test active
HAWA20 2/4/2024 5:40:37 AM 2/4/2024 11:23:22 AM Grid voltage fault
HAWA20 2/4/2024 11:31:53 AM 2/4/2024 11:35:33 AM Wiring Issue, Grid or Line converter
HAWA20 2/9/2024 1:00:49 AM 2/9/2024 1:02:53 AM Uncontrol battery test active
HAWA20 2/11/2024 3:18:50 AM 2/11/2024 4:05:34 AM Uncontrol battery test active
HAWA20 2/11/2024 4:05:34 AM 2/11/2024 4:10:28 AM Idling command
HAWA20 2/11/2024 4:40:22 AM 2/11/2024 4:42:59 AM Batteries Charging
HAWA20 2/11/2024 5:15:56 AM 2/11/2024 5:22:28 AM Batteries Charging
HAWA20 2/11/2024 5:35:59 AM 2/11/2024 5:42:21 AM Batteries Charging
HAWA20 2/11/2024 5:48:53 AM 2/11/2024 5:49:13 AM Batteries Charging
HAWA20 2/11/2024 5:56:40 AM 2/11/2024 5:59:19 AM Batteries Charging
HAWA20 2/11/2024 6:05:45 AM 2/11/2024 6:08:28 AM Batteries Charging
HAWA20 2/11/2024 6:15:32 AM 2/11/2024 6:16:09 AM Batteries Charging
HAWA20 2/11/2024 6:27:41 AM 2/11/2024 6:30:40 AM Batteries Charging
HAWA20 2/11/2024 6:40:36 AM 2/11/2024 11:30:35 AM Batteries Charging
HAWA20 2/12/2024 6:00:45 AM 2/12/2024 6:02:25 AM Uncontrol battery test active
HAWA20 2/12/2024 7:01:25 AM 2/12/2024 7:03:05 AM Uncontrol battery test active
HAWA21 2/3/2024 5:24:17 PM 2/3/2024 5:26:21 PM Uncontrol battery test active
HAWA21 2/4/2024 5:40:37 AM 2/4/2024 11:39:46 AM Grid voltage fault
HAWA21 2/7/2024 7:23:16 PM 2/8/2024 2:31:05 AM Blade angle asymmetry
HAWA21 2/15/2024 1:07:13 AM 2/15/2024 1:08:53 AM Uncontrol battery test active
HAWA22 2/4/2024 5:40:39 AM 2/4/2024 11:23:47 AM Grid voltage fault
HAWA22 2/5/2024 5:10:25 AM 2/5/2024 5:12:33 AM Uncontrol battery test active
HAWA22 2/8/2024 6:00:03 AM 2/8/2024 6:01:48 AM Uncontrol battery test active
HAWA22 2/9/2024 3:39:40 PM 2/9/2024 8:37:49 PM Stopped for Pitch Batteries Replacement activity
HAWA22 2/12/2024 6:01:08 AM 2/12/2024 6:02:49 AM Uncontrol battery test active
HAWA22 2/12/2024 7:00:04 AM 2/12/2024 7:01:42 AM Uncontrol battery test active
HAWA23 2/2/2024 3:00:17 AM 2/2/2024 3:02:39 AM Uncontrol battery test active
HAWA23 2/4/2024 5:40:39 AM 2/4/2024 11:21:39 AM Grid voltage fault
HAWA23 2/5/2024 12:02:42 AM 2/5/2024 12:03:47 AM Secondary rotor brake does not close
HAWA23 2/9/2024 2:00:33 AM 2/9/2024 2:03:25 AM Uncontrol battery test active
HAWA23 2/16/2024 1:00:49 AM 2/16/2024 1:03:33 AM Uncontrol battery test active
HAWA24 2/3/2024 7:08:49 PM 2/3/2024 7:10:57 PM Uncontrol battery test active
HAWA24 2/4/2024 5:40:39 AM 2/4/2024 11:27:17 AM Grid voltage fault
HAWA24 2/4/2024 11:27:17 AM 2/4/2024 11:40:58 AM Pitch Overrun 0deg
HAWA24 2/8/2024 6:00:23 AM 2/8/2024 6:02:05 AM Uncontrol battery test active
HAWA24 2/15/2024 4:59:45 AM 2/15/2024 5:01:47 AM Uncontrol battery test active
HAWA25 2/4/2024 5:40:37 AM 2/4/2024 11:23:18 AM Grid voltage fault
HAWA25 2/4/2024 11:23:18 AM 2/4/2024 1:38:41 PM Pitch controller communications fault
HAWA25 2/11/2024 12:36:17 PM 2/11/2024 12:38:27 PM Uncontrol battery test active
HAWA25 2/18/2024 11:36:33 AM 2/18/2024 11:44:46 AM Uncontrol battery test active
HAWA25 2/18/2024 12:29:51 PM 2/18/2024 2:34:58 PM HSSL / HSLA, Rotor converter
HAWA25 2/18/2024 2:40:33 PM 2/18/2024 2:47:54 PM Power Supply
HAWA26 2/3/2024 7:08:49 PM 2/3/2024 7:10:53 PM Uncontrol battery test active
HAWA26 2/4/2024 5:40:39 AM 2/4/2024 11:27:31 AM Grid voltage fault
HAWA26 2/4/2024 11:27:31 AM 2/4/2024 11:34:11 AM Pitch Overrun 0deg
HAWA26 2/5/2024 12:03:46 AM 2/5/2024 12:08:58 AM Secondary hydraulic braking time too long
HAWA26 2/6/2024 6:01:24 AM 2/6/2024 6:03:04 AM Uncontrol battery test active
HAWA26 2/13/2024 5:01:53 AM 2/13/2024 5:03:32 AM Uncontrol battery test active
HAWA27 1/31/2024 2:50:41 PM 1/31/2024 2:52:22 PM Uncontrol battery test active
HAWA27 2/4/2024 5:40:37 AM 2/4/2024 11:34:33 AM Grid voltage fault
HAWA27 2/6/2024 6:01:34 AM 2/6/2024 6:05:46 AM Uncontrol battery test active
HAWA27 2/13/2024 5:01:53 AM 2/13/2024 5:04:34 AM Uncontrol battery test active
HAWA27 2/15/2024 10:21:51 AM 2/15/2024 10:22:33 AM Secondary rotor brake does not close
HAWA28 2/3/2024 6:32:33 PM 2/3/2024 6:34:39 PM Uncontrol battery test active
HAWA28 2/4/2024 5:40:39 AM 2/4/2024 11:34:06 AM Grid voltage fault
HAWA28 2/6/2024 6:00:01 AM 2/6/2024 6:01:39 AM Uncontrol battery test active
HAWA28 2/8/2024 1:30:36 AM 2/8/2024 1:32:28 AM HSSL / HSLA, Rotor converter
HAWA28 2/11/2024 2:39:56 PM 2/11/2024 4:20:21 PM HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 4:59:45 AM 2/13/2024 5:01:25 AM Uncontrol battery test active
HAWA28 2/13/2024 5:28:49 AM 2/13/2024 5:31:31 AM HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 8:58:31 AM 2/13/2024 2:19:32 PM HSSL / HSLA, Rotor converter
HAWA28 2/13/2024 2:19:45 PM 2/13/2024 2:28:17 PM Tachometer
HAWA28 2/13/2024 2:53:31 PM 2/13/2024 8:04:38 PM Grid voltage fault
HAWA28 2/13/2024 8:12:44 PM 2/13/2024 8:25:28 PM Idling command
HAWA28 2/14/2024 4:49:23 PM 2/14/2024 8:06:44 PM HSSL / HSLA, Rotor converter
HAWA29 2/4/2024 5:40:37 AM 2/4/2024 11:34:04 AM Grid voltage fault
HAWA29 2/4/2024 11:39:47 AM 2/4/2024 11:40:20 AM Blown Fuses
HAWA29 2/4/2024 11:43:10 AM 2/4/2024 11:44:08 AM Blown Fuses
HAWA29 2/4/2024 11:46:38 AM 2/4/2024 12:27:37 PM Blown Fuses
HAWA29 2/4/2024 12:33:06 PM 2/4/2024 2:23:04 PM Blown Fuses
HAWA29 2/6/2024 6:00:11 AM 2/6/2024 6:01:51 AM Uncontrol battery test active
HAWA29 2/13/2024 4:59:45 AM 2/13/2024 5:02:27 AM Uncontrol battery test active
HAWA29 2/15/2024 11:54:12 AM 2/15/2024 11:54:48 AM Secondary rotor brake does not close