You are on page 1of 1

Lot 220 Lot 221 Lot 222 Lot 223 Lot 224 Lot 225

Unit 98.3m2 Unit 98.3m2 Unit 98.3m2 Unit 98.3m2 Unit 98.3m2 Unit 98.3m2

A B D E F G H I J K L M
C

4 DP12 DP11 DP8 DP7

DP10 DP9
3

NOTES:

1. Provide AAV (air admittance valves) if


FWG FWG
DN40 DN40
FWG FWG FWG FWG
DN40 DN40
FWG FWG FWG FWG
DN40 DN40
FWG FWG
max developed length of single discharge
DN40 DN40 DN40 DN40 DN40 DN40 pipe without venting is exceeding 2.5

W/M

W/M

W/M

W/M

W/M
W/M

DN65 DN65 DN65 DN65 DN65 DN65 meters.


DN40 DN40 DN40 DN40 DN40 DN40 2. Provide Thru-joist brackets for pipe
DN100 DN100 DN100 DN100 DN100 DN100
50 TV penetrations through joists.
TERMINATES
200mm AFRL 3. Provide maintenance access points /

DN40

DN40

DN40
DN40

DN40

DN40
SHW SHW SHW SHW SHW SHW
cleaning eyes / inspection junction to soil
FWG DN65 DN65 DN65 DN65 FWG FWG DN65 DN65 DN65 DN65 FWG FWG DN65 DN65 DN65 DN65 FWG pipes to comply with AS/NZS 3500.2.
JOINING UP
WITH STACK
WALL PLUMBING & DRAINAGE TO AS/NZS
3500:

1. All plumbing and drainage including


pipe sizes, gradients,
inspection points to comply with
AS/NZS3500.
Wastewater drain 2. Lag all HW pipes between hot water
Stormwater drain unit and shower & kitchen.
3. Exact pipe routes to be clarified and
SS Sanitary Sewer coordinated on site.
SW Stormwater 4. Provide HYjoist to allow pipe
TV Terminal Vent penetrations through web.
IB Inspection Bend 5. All pipes sizes below ground are to be
IJ Inspection Junction 100mm ⌀.
AAV Air Admittance Valve 6. Provide maintenance access points /
2 DP Down Pipe cleaning eyes / inspection junction to soil
DP3 DP4 ORG Overflow Relief Gulley pipes to comply with AS/NZS 3500.2.
1
DP1 DP2 DP5 DP6 FWG Floor Waste Gulley 7. Pipe material to be Fusiotherm unless
HWC Hot Water Cylinder noted otherwise.

REFER CIVIL STORMWATER AND WASTEWATER


LOT CONNECTIONS TO : SHEET C001-SITE PLAN
PIPE SIZES: Max Fixture unit LOADING for vented drain AS/NZS 3500/2
1. DN65 drain shall not Waste pipes sizes to have a diameter
receive (WC) soils fixtures. as per the table below: Grade Grade 65mm 80mm 100mm
2. "x" indicates not % 1 in pipe pipe pipe
acceptable. HWC - hot water cylinder =25mm⌀ 5.0 1 in 20 60 215 515
3. (xxx) maximum grades if it SHW - shower = 40mm⌀
is not possible to 3.35 1 in 30 36 140 345
SINK - sink = 40mm⌀
achieve the connection points.
4. Councils are able to DW - dish washer = 40mm⌀
2.5 1 in 40 25 100 255
approve alternative WHB - wash hand basin = 40mm⌀
gradients, based on observed WM - washing machine = 40mm⌀ 2.0 1 in 50 X 76 205
peak flows. TUB - tub = 40mm⌀
5. Oversizing drains should FWG - floor waste gulley = 40mm⌀ 1.65 1 in 60 X 61 165
not occur except where
fixture loadings exceed the 1.45 (1 in 70) X (50) (140)
maximum for that size of drain. Branch Drains: min 65mm⌀ as per
AS/NZS3500 figure 3.1 and table 3.1.
1.25 (1 in80) X (42) (120)

1 01 First Floor Drainage


1 : 50 @ A1
1 : 50
0 1 2 3 4 5 6 7 8 9 10 m

PROJECT TITLE DRAWN BY CHECKED BY DATE


BIM AssetLab Ltd BAL-VU QDZ-VW 23/12/22
244 SCENIC DRIVE, TITIRANGI, AUCKLAND 0604
Ormiston Rise PLUMBING & DRAINAGE

2/06/2023 9:59:28 am
TEL (027) 484 8652, EMAIL : raewyn@bimassetlab.com
PLAN - FIRST FLOOR SCALE (@ A1) PROJECT NUMBER

1 : 50 @ A1 Stage 2A
This drawing remains the intellectual property of Aedile Advisors
Limited and shall not be copied or distributed to any third party 125C Murphys Rise PROJECT NORTH

without prior written approval of Aedile Advisors Limited. STATUS PURPOSE OF ISSUE DRAWING NUMBER REV
Confirm all dimensions onsite prior to commencement of work. Flat Bush A Building consent/Construction 2022-12-14 BUILDING CONSENT/
Do not scale off drawings. All work shall conform to all relevant
clauses of the New Zealand Building Code (NZBC) and NZ/AS Auckland 2016 Rev Description Date CONSTRUCTION P102 A
standards.
TRUE NORTH