A B C D E F G GROUND FLOOR LEVEL

EXI: GL
370 370 275 370 213 158

180 180 180 180


5

R
119

PLINTH BEAM WELL COMPACTED SOIL

220

220

220

220
180

180
4

COLUMN

D
Min 30

FN3

FN3

FN3

FN3
FN1 FN1
PCC
290

140 140
160 255 255 160 HARD STRATA
EXI: GL
200 200
200

200
SECTION A-A

FN5

FN5
3

215

215
240

240
FN2 FN2
FN6 FN6
300

160 160 L1 L1
255 255

5
FN5

FN5
200

200

D
2

A A
215

215
R

240

240
Ld
FN2 FN2

D1
FN6 FN6
200 200 Ld
349

PCC
200 200
240 240
FN4

FN4
240 L/B

240
180

180
200

200
1

TYPICAL SECTION FOR STEPPED


FN1 FN1 PLAN
FN4 FN4 FOOTIN
140 140
TYPICAL LONGITUDINAL SECTION OF PLINTH BEAM TYPICAL FOOTING DETAIL
DETAIL OF PLINTH BEAM
SHOWING CURTAILMENT OF REINFORCEMENT
LAYOUT OF FOOTING & COLUMN
3,#12

L #8@18
Tie as per detail
L/4 L/4 L/4 3,#12
Extra bar Main bar Extra bar Column PB 20x40

Dimension Stirrups COLUMN


Designation Bottom Top Reinforcement #8@10
Sl. NO.
L B D L1 D1 Reinforcement

1m
Pile cap
Pile cap Main bar Extra bar Main bar

1 FN1 1.8 1.4 325 -- -- 12mm @120c/c -- --

Mid section
Pile 100 100 Pile 100

section
Support
2 FN2 2 1.6 400 -- -- 12mm @120c/c -- -- BEAM BEAM
NOTE:
3 FN3 2.2 1.8 450 -- -- 12mm @120c/c -- -- 1. THE PLINTH BEAM SHALL REST ON HARD STRATA.
2. PROVIDE 10CM THICK PCC USING MIX 1:4:8 AT BOTTOM WHEREEVER REQUIRED. #8@10

1m
4 FN4 2.4 2 200 500 300 16mm @180c/c 12mm @300c/c
DETAIL OF COLUMN
COLUMN
COLUMN COLUMN
SL. NO. NOTATION COLUMN DETAIL COLUMN TIES
5 FN5 2.4 2 200 500 300 16mm @150c/c 12mm @300c/c NUMBER SIZE
60 Tie as per detail
6 FN6 2.55 2.15 200 500 300 16mm @120c/c 12mm @300c/c 01 CL1 N/A 20X60

20
#8@15 c/c
TYPICAL CONFINING REINFORCEMENT
FOR COLUMN
REVISIONS: GENERAL NOTES:
PROJECT RESIDENTIAL BUILDING AT KOLLAM CLIENT BHASI NO: DATE DETAIL
1. ALL DIMENSIONS ARE IN CENTIMETERS & BAR DIAMETER 6. FORMWORK SHALL BE ADEQUATE TO BEAR THE LOAD
IN MILLIMETERS. WHILE CONCRETING AND IT IS THE RESPONSIBILITY OF
PROJECT NO: JA/KLM/RB/05/2020
ARCHITECT

2. CLEAR COVER TO MAIN REINFORCEMENT : THE CONTRACTOR.


FOOTING, RAFT 50 mm 7. DESIGNER IS NOT RESPONSIBLE FOR DEFECTS ARISING
DRG. TITLE DETAILS OF FOOTING AND COLUMN
SHEET SIZE
KPA PILE
PILE CAPS
60 mm
75 mm
OUT OF USE OF FAULTY/POOR QUALITY MATERIAL AT
SITE .
SHEET NO: SD/CON/01 PLINTH BEAMS 25 mm 8. BENDING AND PLACING OF STEEL BARS SHALL CONFIRM
A2 BEAMS 25 mm TO SP:34.
DATE OF ISSUE 25-10-2020 STATUS SLABS, STAIRS 20 mm 9. MACHINE MIXED CONCRETE SHALL BE USED FOR
COLUMNS 40 mm CONCRETING.
CONSULTANT
STRUCTURAL

MIX/STEEL GRADE M20 / Fe 500 TENDER WATER TANKS 30 mm 10.BEAM SHALL BE ANCHORED IN TO THE COLUMN AS
3. ALL RCC WORKS (INCLUDING MATERIALS) SHALL SHOWN.
DRAWN DESIGNED CHECKED ESTIMATION J&A CONFIRM TO IS:456 - 2000 OR ITS LATEST REVISION.
4. PRECAST COVERING BLOCKS OF SAME MIX CONCRETE
11.LAP/ANCHORAGE LENGTH OF STEEL BARS (Ld) IS
EQUAL TO 50 TIMES DIAMETER OF BAR.
AKP AKP JO DISCUSSION CONSULTING ENGINEERS SHALL BE USED TO ENSURE ADEQUATE COVER. 12.ALL DIMENSIONS,LEVELS ETC SHALL BE CHECKED WITH
5. LEVELS AND PLUMB OF FORMWORK SHALL BE CHECKED RELEVANT ARCHITECTURAL DRAWINGS. VARIATION,IF
PH NO: 9496811040, 9895996749
SCALE AND CONFIRMED BY THE CONTRACTOR OR SITE ANY, SHALL BE CLARIFIED BEFORE EXECUTION.
NOT TO SCALE. CONSTRUCTION ENGINEER.