! 12 Volt and 24 Volt ECM’s available.
If you are not sure of the voltage and the markings have been removed
check PIN 35 to ground 1.4K Ohms – 12 volts / 2.8K Ohms – 24 volts.
Email
@ Perkins
Did you find this document useful?
Notes:
On start up for genset applications the ECM automatically determines which speed/load
signal ‘out of range’ (o.o.r.) fault management to use. This is dependant on the wiring
configuration it observes
Stand alone (isochronous) operation – APS & RPS inputs are both inactive.
Manual synchronised load sharing – APS input is active, RPS input is inactive.
2 way protection is achieved by selecting 3 way protection and ‘normally open (plastic
tank)’ for the CLS type. No connection should then be made to the CLS input.
Page 8
) Useful
* Not useful
W
Terminal can be Interface harness ir
To starter and
marked 87 or G in
charging circuits (if used) Chassis harness connector g
1 d
Main See note 5
Stand alone (isochronous) power rly ECM a i
g
operation Emergency 10 86 85 18 AWG 18 AWG
25 Power relay out a r
stop device AWG 30 AMP 10 AWG 14 AWG m
APS (PIN 8) & RPS (PIN 30) 30
87 21 DC/DC Converter -
14 AWG S
in uts are both inactive Rating 30A 87a
22 (+) Feed
min
1 14 AWG ta
41 HSO (+) Feed n
8
d
A
See note 4 See note 2 14 AWG
a
W
+ 23 HSO Ground feed
14 AWG l
G
42 DPS O/P s Ground feed
’
o
Battery 14 AWG n
1 DC/DC Converter e
- 10 AWG 14 AWG (i
2 Ground feed s
o
5 AMP c
12V or 24V 18 AWG h
37 PRE Input
o r
18 AWG
32 SCS Input (set coast) n
Attention + Diagnostic o
switch u
1 Battery 18 AWG 18 AWG s
34 STI Switch )
Note: Power supply for ECM must
- On/off switch u r
be taken directly from the battery,
16 AWG 5 AMP 18 AWG n
not the starter motor terminal. 24 VIGN - IPR (+) Feed n
in
g
Notes
1) Wire sizing:
10AWG (approx. 5mm 2 ) Main feed and return to battery
14AWG (approx. 2mm 2 ) ECM pin Nos 21.22.41.23.42.1.2
16AWG (approx. 1mm 2 ) Ignition and diagnostic socket supply
18AWG (approx. 0.8mm 2 ) All other circuits 1
6
A 18 Red
2) Main Power Relay W 10 AMP AWG lamp
12V part no. 1688314C1 18 AWG
54 Oil water lamp output
G
(12V alternative part no s. 2848A203)
’
W
ir
To starter and Terminal can be in
charging circuits marked 87 or G Interface harness (if used)
g
Chassis harness connector
d
1 Main See note 5 a i
Manual synchronised load power rly ECM g
Emergency 10 a r
sharing stop device AWG
86 85 18 AWG 18 AWG
25 Power relay out m
30 AMP
APS input (PIN 8) is active 10 AWG 14 AWG
21 DC/DC Converter -
M
87
30
14 AWG
RPS input (PIN 30) is inactive Rating 30A 87a
22 (+) Feed a
min 14 AWG n
41 HSO (+) Feed u
a
+ See note 4 See note 2 14 AWG l
23 HSO Ground feed s
Battery 14 AWG y
42 DPS O/P s Ground feed
’
n
14 AWG c
- 1 DC/DC Converter h
10 AWG 14 AWG
2 o r
Ground feed
n
Attention 12V On/off switch s i
or 16 AWG 5 AMP 18 AWG e
1 24 VIGN - IPR (+) Feed d
24V
o l
Note: Power supply for ECM must a
be taken directly from the battery, d
Manual speed
not the starter motor terminal.
+ 250 s
(demand) signal. h
Battery Ohms a
(working range 3 VBREF (5V) Sensor supply ri
Notes - 0.5 to 4.5 volts 2K n
Ohms
8 APS Input g
into ECM pin 8). 11 VBREF GND Sensor supply
1) Wire sizing:
All resistors rated 250 See note 7
10AWG (approx. 5mm 2 ) Main feed and return to battery See
14AWG (approx. 2mm 2 ) ECM pin Nos 21.22.41.23.42.1.2 at 0.25 watts. Ohms note 3
16AWG (approx. 1mm 2 ) Ignition and diagnostic socket supply Diagnostic
18AWG (approx. 0.8mm 2 ) All other circuits
switch
18 AWG 18 AWG
2) Main Power Relay 34 STI Switch
12V part no. 1688314C1
1
6
(12V alternative part no s. 2848A203)
’ A 18
W
10 AMP Red lamp
G AWG 18 AWG
24V part no. 2848A226 54 Oil water lamp output
0 See note 6
3) Where shown, cables must be twisted together (360 per 25 mm and Amber lamp
screened to minimise noise effects. Connect screen at one end only. 18 AWG
55 ENG Warn light output
4)
All fuses must comply with SAE J1284 and be located close to the Diagnostic
battery so as to protect the wiring. connector
5) CEBA
All unused interface harness cables must be insulated. 10 AMP 16 AWG
6) Recommended rating for lamps is between 2 and 2.2 watts. Clear wire 18 AWG
16 ATA (+)
16 AWG Black wire 18 AWG (Data link J1708)
7) Where shown, cables must be twisted together (360 0per 25 mm a 17 ATA (-)
W
3
1 See note 3
6
2
/1
W
To starter and ir
Terminal can be in
charging circuits 1 marked 87 or G Interface harness (if used) Chassis harness connector g
d
Main See note 5
a i
power rly ECM g
Emergency 10 18 AWG 18 AWG a r
Automatic synchronised load m
86 85
stop device AWG 30 AMP 25 Power relay out
10 AWG 14 AWG
87 21 DC/DC Converter -
sharing Rating 30A
30
14 AWG A
u
87a
22 (+) Feed
APS input (PIN 8) is inactive min 14 AWG
41 HSO (+) Feed
to
m
5
10 AMP AWG
W
G lamp 18 AWG
54 Oil water lamp output
24V part no. 2848A226
Amber See note 6
0
3) Where shown, cables must be twisted together (360 per 25 mm and lamp 18 AWG
screened to minimise noise effects. Connect screen at one end only. 55 ENG Warn light output
4)
All fuses must comply with SAE J1284 and be located close to the Diagnostic
battery so as to protect the wiring. connector
5) CEBA
All unused interface harness cables must be insulated. 10 AMP 16 AWG
Clear wire 18 AWG
6) Recommended rating for lamps is between 2 and 2.2 watts. 16 ATA (+)
16 AWG Black wire 18 AWG (Data link J1708)
17 ATA (-)
7) Where shown, cables must be twisted together (360 0per 25 mm a
See note 3
W
1
3
6
3
/
1
W
To starter and Terminal can be ir
charging circuits marked 87 or G in
Interface harness (if used) Chassis harness connector g
1 Main See note 5 d
ECM a i
power rly g
Emergency 10
86 85 18 AWG 18 AWG a r
stop device AWG 30 AMP 25 Power relay out m
10 AWG 14 AWG
30
87 21 DC/DC Converter -
14 AWG 1
Rating 30A 87a
22 (+) Feed 5
1
14 AWG 0
8
min 41 HSO (+) Feed 0
A
/1
W
See note 4 See note 2 14 AWG
8
G
23 HSO Ground feed
14 AWG 0
+ 42 DPS O/P s Ground feed
’
0
Battery
14 AWG
1 DC/DC Converter e r
10 AWG 14 AWG v
- 2 Ground feed /m
5 AMP in
18 AWG
Attention 37 PRE Input S
1
12V or 24V J1
18 AWG w
J2
32 SCS Input (set coast) tc i
Note: Power supply for ECM must See note 7 18 AWG
31 RAS Input (resume/accel) h
be taken directly from the battery, + a
Diagnostic b
not the starter motor terminal. Battery switch e l
18 AWG 18 AWG
34 STI Switch s
Notes
- ta
On/off switch n
16 AWG 5 AMP 18 AWG
d
1) Wire sizing:
24 VIGN - IPR (+) Feed a
10AWG (approx. 5mm 2 ) Main feed and return to battery o l
14AWG (approx. 2mm 2 ) ECM pin Nos 21.22.41.23.42.1.2 n
16AWG (approx. 1mm 2 ) Ignition and diagnostic socket supply e
18AWG (approx. 0.8mm 2 ) All other circuits s i
o
c
2) Main Power Relay h
1
o r
12V part no. 1688314C1 18
6
Red n
o
A
(12V alternative part no s. 2848A203)
’
W 10 AMP AWG lamp 18 AWG u
54 Oil water lamp output s
G
24V part no. 2848A226
Amber See note 6 (n
o
3) Where shown, cables must be twisted together (360 0per 25 mm and lamp 18 AWG n
screened to minimise noise effects. Connect screen at one end only. 55 ENG Warn light output -l
o
4) a
All fuses must comply with SAE J1284 and be located close to the Diagnostic d
battery so as to protect the wiring. connector s
CEBA h
5) a
All unused interface harness cables must be insulated. 10 AMP 16 AWG ri
n
Clear wire 18 AWG g
6) Recommended rating for lamps is between 2 and 2.2 watts. 16 AWG Black wire 18 AWG
16 ATA (+)
(Data link J1708) )
17 ATA (-)
7) Genset speed settings.
W See note 3
3 For 1500 rpm connect link J1
1
6
/1 For 1800 rpm connect link J2
4
) Useful
* Not useful
W
ir
in
g
d
a i
Emergency g
Chassis harness connector a r
stop Vbal m
Coolant -
10 Coolant level switch G
level e
n
Request to
switch See note 2 PIN 10 S
+ + e
shutdown t
Battery Battery o
p
See note 1 ti
- -
10 AMP o
On/off n
Red 54 OWL Output (press/temp) s
Additional notes
1) Maximum total current from OWL (54) output = 1 Amp (including lamp and Engine harness connector
’request to shutdown’ signal).
2) Coolant level sensor operation depends on EPN option selected Single pin
Snooze
’normally closed (metal tank)’ connector
’narmally open (plastic tank)’. 11 Snooze (run enable)
3) Customers must specify the relay, the wiring and appropriate fuses for 10 AMP
86 85
A
the radiator shutter control circuit. B 9 Radiator shutter
30
87 Two pin
87a connector
Radiator
shutter
Snooze (run enable) single pin connector: control relay
Packard part # Description See note 3
12065171...............Mating connector
12065249...............Secondary lock
12048159...............Male terminal 18 - 16 AWG
W
1
3
6
5
PowerWizard Training
Presentation
Jorge
Magazines Podcasts
Sheet Music
Wiring Diagram
jesus silva
1300WS
ishumbar
Show more
About Support
Press Accessibility
Contact us Publishers
Invite friends
Social
GiKs
Twitter
Legal Facebook
Terms Pinterest
Privacy
Copyright
Language: English
Related titles
,
,
Home Books Audiobooks Documents