1
25-32
04-09 INSULATED
PIERCING
Brackets
CONNECTORS
42-44
TELECOMMUNICATION
12-21 CABLES
ACCESSORIES
CLAMPS

10-11 33-41
ASSEMBLIES MISC PARTS
45-51
NON-INSULATED
NETWORK
ACCESSORIES

22-24
PREINSULATED
2
JOINTS
ATOM ELECTRIC
ATOM was founded as a part of the vision of founders to produce innovative products, that can compete internationally.
we manufacturer of electrical fittings and fixtures. Our products are designed and produced using a highly advanced processes
utilizing the Egyptian manpower and our European strategic partner’s knowledge. Our team are working periodically to update our
processes internationally. We adopt a strict QMS procedures for the whole processes starting from product design till final product
assembly and customer delivery. ATOM sincerely welcoming customer all around the world to cooperate with us. And we are open for
agents who are to interesting hold together for creating the future in providing high quality electrical and power products.
Looking forward to be partners in our future success story.

3
Brackets

4
Brackets

ALUMINUM BRACKET
Aluminum Bracket is used for receiving LV ABC across a Dead End Clamp
PA 1500 or Suspension Clamp PS 1500. It has extraordinary tensile
strength and is made of aluminum alloy.
Its design provides easy, fast and reliable installation. Minimum breaking
strengths are shown in the technical drawing.

CA 1500

CA-CS 1500

CA-CS 1500 G

5
CA-CS 2000
Aluminum Bracket is used for receiving LV ABC across a Dead End Clamp
or Suspension Clamp. It has extraordinary tensile strength and is made of
aluminum alloy. provides easy, fast and reliable installation.

CA-CS 2200
Aluminum Bracket CA-CS 2200 is used for receiving LV ABC across a dead
end clamp or a suspension clamp.
It has extraordinary tensile strength and is made of aluminum alloy.
Its design provides easy, fast and reliable installation. It is fixed on the
pole with two or three stainless steel bands or two bolts M16.

6
Brackets

CT 600
Bracket CT 600 is used for receiving LV ABC across a Dead End Clamp or Suspension Clamp.
Its design provides easy, fast and reliable installation on facades.
It is fastened using bolts M12.
It is made of zinc plated steel sheet metal.
Minimum breaking strength is 600 daN.
Brackets can be hot-dip galvanized on Customer’s request.

CAB 25
Aluminum Bracket CAB 25 is used for receiving LV ABC across Anchoring Clamp PA
25, PAC 80, PA 80, UMS PAM 35, PA 25-2 or similar technical solutions for anchoring
clamps. It has high tensile strength and is made of aluminum alloy.
Its design provides easy, fast and reliable installation in two ways - with stainless
steel band or with M10 bolt. Minimum breaking strength is 4 kN.

ALEX 29
Bracket Alek29 is used for receiving LV ABC across a Dead End Clamp or Suspension
Clamp.
Its design provides easy, fast and reliable installation on poles.
It is fastened using stainless steel strap.
It is made of zinc plated steel sheet.
It is resistant to environmental and mechanical effects.
Brackets can be hot-dip galvanized on Customer’s request.
7
PIGTAIL EYE BOLT
Pigtail eye bolt is used on wooden, concrete and other power poles for receiving
ABC across Dead End clamps and Suspension Clamp. Its installation is easy, by push-
ing it through a hole and tightening with a nut.

STEEL BRACKET FOR HOUSEHOLD


CONNECTION CA 25
The Bracket is used for receiving LV ABC across anchoring clamps or for mounting on
facades across suspension clamps.

8
Brackets

CLUSTER MOUNT
Cluster Mount is used on power and telecommunication poles
as a connection between the pole and other elements which are
necessary for installation and proper usage of LV ABC. Cluster
mounts can be surface protected using process of tin plating or
hot-dip galvanization depending on Customers request.

SQUARE CLUSTER MOUNT WITH HOOKS CLUSTER MOUNT WITH OR WITHOUT HOOKS

RING CLUSTER MOUNT WITH TWO RINGS RING CLUSTER MOUNT WITH ONE RING CLUSTER MOUNT TYPE AP CLUSTER MOUNT TYPE A

9
ASSEMBLIES

10
ASSEMBLIES

SUSPENSION ASSEMBLY
Suspension Assembly consists of Aluminum bracket and Suspension clamp
PS 1500.
ES 1500
Suspension Assembly has range of use from 54,6mm2, 71,5mm2 when
carrying LV ABC via insulated suspension conductor, And it can carry LV ABC
of any cross-section from 16 mm2 to 95 mm2.

ES 2000 ES 1500 G

DEAD END ASSEMBLIES


Dead End Assemblies are used in combination with
different brackets.No special tools are needed for
installation.

11
CLAMPS

12
CLAMPS
Dead End Clamp
Dead End Clamp PA 600 is used for tightening LV ABC with insulated conductor and
its function is to receive LV ABC on the places where it is technically defined.
Its design provides easy, fast and reliable installation in all weather conditions.
It is installed using no tools and do not contain parts which can fall off.
Dead End Clamp PA 600 consists of the body casted of aluminum alloy and
self-adjusting plastic wedges which tighten the conductor without insulation
damage.
All parts of Dead-End Clamp PA 600 are resistant to corrosion, environmental effects
and UV radiation.
Maximum turning angle is 45 degrees for one-sided tightening and 90 degrees for
two-sided tightening. Minimum breaking strength is 6 kN.
The Clamp is delivered with hot-dip galvanized or stainless-steel cord.

13
Dead End Clamp
Dead End Clamp is used for tightening LV ABC with insulated conductor and its function is to receive LV ABC on the places where it is technically defined. Its
design provides easy, fast and reliable installation in all weather conditions. It is installed using no tools and do not contain parts which can fall off. Dead End
Clamp consists of the body casted of aluminum alloy and self-adjusting plastic wedges which tighten the conductor without insulation damage.
All parts of Dead-End Clamp are resistant to corrosion, environmental effects and UV radiation. Maximum turning angle is 45 degrees for
one-sided tightening and 90 degrees for two-sided tightening. Minimum breaking strength is 20 kN.

PA 1500 PA 2000

14
CLAMPS
Service Anchoring Clamp
Service Anchoring Clamp Is used for network connection when cross sections of LV ABC Service Anchoring Clamp PA 25 is made of high-quality
materials of high tensile strength and resistance to environmental effects and UV radiation. It is tested and certified so that it complies with all
standards for cable accessories. Inside canals of Service Anchoring Clamp PA, 25 are cogged so that they have excellent mechanical contact with
the conductor’s insulation thus disabling slippage, and the effect of most reliable tightening is achieved. Minimum breaking force is 2 kN. On the
Customer’s request metal parts can be hot-dip galvanized or stainless steel.

PA 25 2x10/2x16/2x25 mm2 PA 25 2/4x10-25 mm2

15
CLAMPS
ANCHORING CLAMP UMS PAM 35 1/4 x 10-50 mm2
ATOM Clamp UMS PAM 2/3/4 x10;16;35;50 mm2 can be used as dead end, suspension
and angular clamp for LV ABC distribution networks and other overhead lines within the
range from 10 mm² and 50 mm and with 1 to 4 conductors in the clamp.
The clamp is made of high-quality material poliamid 6,6 GF 30 of high tensile strength and
resistance to environmental effects.
It is tested so that it complies with all standards for cable accessories.
Inside canals of ATOM Clamp UMS PAM 35 are cogged so that they have excellent
mechanical contact with conductor’s insulation.
Tightening is done via PA shear head nut of 12Nm.
When the clamp is properly tightened ABC cannot be pulled out of cogged parts of the
clamp, which leads to great installation possibilities and usage of the clamp without
possibilities of loosing.
ATOM Clamp UMS PAM 35 is designed in such a way that it can tighten, support or change
the angle of ABC route and it can be safely installed on power lines if proper protective
equipment is used.
The Clamp is installed by tightening the shear head PA nut with ring wrench No. 13 or No.
22 and removed with open-end wrench No. 22. It does not contain parts that can fall off.
The bolt and metal part of shear head nut are made of stainless steel.

Tightening torque: 12Nm at tightening: 6kN.


Minimum breaking force at suspending: 6kN.
Minimum breaking strength at angular turning: 6kN.

16
DN 318
Service Anchoring Clamp DN 318 is used for different conductors of cross sections
between φ3mm and φ18mm. Service Anchoring Clamp DN 318. It is tested and certified
so that it complies with all standards for cable accessories.
Inside canals of Service Anchoring Clamp DN 318 are cogged so that they have
excellent mechanical contact with conductor’s insulation thus disabling slippage and the
effect of most reliable Tightening is achieved. Minimum breaking force is 2 kN.
On Customer’s request metal parts can be hot-dip galvanized or stainless steel.

Service Anchoring Clamp


Anchoring Clamp 4x16-35mm² is used in power networks conducted by LV ABC of
cross-section from x16mm² to 4x35mm². Tightening is achieved via shear head nut of
maximum tightening torque of 18 Nm. Minimum breaking force is 7,5 kN.

PA 80 4x16-35mm2

PAC 80 4x16-35mm2

17
CLAMPS
Dead End Clamp
Dead End Clamp PA is used to tighten LV ABC without insulated conductor and has a
function to receive LV ABC made of 2 to 4 conductors from 10 to 50 mm² on the places
where it is technically defined.
Its design provides easy, fast and reliable installation in all weather conditions.
Dead End Clamp PA has self-adjusting plastic wedges which tighten 2 to 4 conductors of
LV ABC without insulation damage.
All parts of Dead End Clamp PA are resistant to corrosion and environmental effects.
It is made of surface protected steel, Polyamide 6.6 GF 30. Bolt M12 and self-blocking nut
enable the clamp to be installed on a U stirrup or closed bracket.

Intersection Minimum
Type a(mm) b(mm) L(mm)
conductors breaking force
PA 450 4x50-10 45 80 285 28
PA 495 4x95-50 41 120 325 43
PA 4150 4x150-95 53 145 480 82

18
PAC 25 2/4X10-25 mm2
Service Anchoring Clamp PAC 25 2/4x10-25 mm² is used for network connection when
cross sections of LV ABC are 4(2)x10 mm², 4(2)x16 mm² or 4(2)x25 mm². Service
Anchoring Clamp PAC 25 is made of high-quality materials of high tensile strength and
resistance to environmental effects and UV radiation.It is tested and certified so that
it complies with all standards for cable accessories. Inside canals of Service Anchoring
Clamp PAC 25 are cogged so that they have excellent mechanical contact with conductor’s
insulation thus disabling slippage and the effect of most reliable tightening is achieved.
Maximum breaking force is 3 kN. It allows maximum tightening of the conductor up to
103mm.On Customer’s request metal parts can be hot-dip
galvanized or stainless steel.

SUSPENSION CLAMP PS 1500


Suspension Clamp PS 1500 is used to receive LV ABC with insulated conductor. Receiving is done
via suspension conductor of 16 - 71,5 mm². It is resistant to environmental and mechanical effects
and UV radiation since it is made of material of high tensile strength and stable structure.
Suspension Clamp allows turning angle of 30o.
It is installed using no tools and do not contain parts which can fall off.

19
SUSPENSION CLAMP PS 1500
Suspension Clamp PS 1500 is used to receive LV ABC with insulated conductor. Receiving
is done via suspension conductor of 16 - 71,5 mm². It is resistant to environmental and
mechanical effects and UV radiation since it is made of material of high tensile strength
and stable structure. Suspension Clamp allows turning angle of 30o.
It is installed using no tools and do not contain parts which can fall off.
Type Intersection conductors

PS 1500-54.6 16-54.6
PS 1500-71.5 50-71.5

SUSPENSION CLAMP PS 2000


Suspension Clamp PS 2000 is used to receive LV ABC with insulated conductor. Receiving
is done via insulated suspension conductor of 54,6 mm² or 71,5 mm², and can carry any
LV ABC of cross section between 16 mm² and 150 mm² . It is resistant to
environmental and mechanical effects and UV radiation since it is made of material of
high tensile strength and stable structure.Suspension Clamp allows turning angle of 30o.It
is installed using no tools and do not contain parts which can fall off.
NOTE: Suspension Clamp is made in two models:
1) With forged aluminum articulated link which cannot be opened.
2) Separable Polyamide articulated link which can be opened using no additional tools.
Type Diameter conductors

PS 2000-64.6 16-54.6
PS 2000-71.5 50-71.5
PS 2000-150 70-150

20
CLAMPS
ANGULAR SUSPENSION CLAMP PS 300
Angular Suspension Clamp PS 300 is used to receive LV ABC of 4 (2)x10 mm², 4 (2) x16
mm², 4 (2)x25 mm² or 2x35 mm² in order to carry and optionally allow change of the
route direction. It is resistant to environmental and mechanical effects and UV radiation
since it is made of material of high tensile strength and stable structure.
Minimum breaking force is 3 kN. It is installed using no tools and does not contain parts
which can fall off.

SUSPENSION CLAMP PS
Suspension Clamp PS is used to receive LV ABC without insulated conductor from 10 to 150 mm².
Receiving is done via 2 or 4 conductors of LV ABC of dimensions from 10 to 150 mm² .
It is resistant to environmental and mechanical effects since it is made of material of high tensile
strength and stable structure, surface protected steel, and elastomer resistant to UV radiation.
Suspension Clamp allows turning angle of 30o.

Type Intersection conductors Maximum diameter

PS 116 4x10-16 14
PS 450 4x10-50 26
PS 495 450-95 32
PS 4150 4x120-150 44

21
PREINSULATED
JOINTS

22
PREINSULATED JOINTS
INSULATED Al-CU JOINT FALIS
Insulated Joint FALIS is used for network connection conductors or street lighting
conductors from 4 to 25 mm². Crimping is done according to engraved marks on the Joint
FALIS with crimping insert E 140. After crimping process the Joint effectuates electrical
contact. Mechanical strength of the joint is 50% of breaking force of the conductor.
The inside of the Joint is filled with electrical contact grease.

INSULATED Al-CU (Al-Al) JOINT MJPB


Insulated Joint MJPB is used for network connection conductors or street lighting
conductors from 4 to 35 mm². Crimping is done over the insulation according to
engraved marks on the Joint MJPB with crimping insert E 140. After crimping process the
Joint effectuates electrical contact and waterproofness by elastomer rings.
Mechanical strength of the joint is 50% of breaking force of the conductor.
Waterproofness is tested in the water under voltage of 6 kV for a period of 30 minutes.
Elastomer ring is made in different colors so that cross sections can be recognized more
easily. The inside of the Joint is filled with electrical contact grease.

INSULATED Al-CU (Al-Al) JOINT MJPT


Insulated Joint MIPT is used for main line conductors with mechanical load. Crimping is
done over the insulation according to engraved marks on the Joint MJPT with crimping
insert E 173 and E 215. After crimping process the Joint effectuates electrical contact
and waterproofness by elastomer rings. Waterproofness is tested in the water under
voltage of 6 kV for a period of 30 minutes. Elastomer ring is made in different colors so that
cross sections can be recognized more easily. The inside of theJoint is filled with electrical
contact grease.Mechanical strength of the joint is:
For LV ABC with all aerial bundled 80% of breaking force of the conductor.
For LV ABC with suspension conductor: 50% of breaking force of phase conductor; 100%
of breaking force of insulated suspension conductor. 23
PREINSULATED JOINTS

INSULATED Al-CU (Al-Al) JOINT MJRP 6-20 KV


Insulated Joint MJRP is used for main line conductors with mechanical load.
Crimping is done over the insulation according to engraved marks on the Joint MJRP
with crimping insert E 173 and E 215, After crimping process the Joint effectuates
electrical contact and waterproofness by elastomer rings.
Waterproofness is tested in the water under voltage of 20 kV for a period of 30 minutes.
Elastomer ring is made in different colors so that cross sections can be recognized more
easily. The inside of the Joints filled with electrical contact grease.
Mechanical strength of the joint is: 95% of breaking force of the conductor.

24
INSULATED
PIERCING
CONNECTORS

25
INSULATED PIERCING CONNECTOR
ATOM insulated piercing connector is used to achieve contact by simultaneously piercing the insulation on LV ABC conductors of main power distribution
line and on insulated copper or aluminum conductors of network connection lines. ATOM insulated piercing
connector is made in such a way that it enables jointing of LV ABC and network connection conductor regardless of whether it is aluminum or copper
conductor. Elastomer insert eliminates bimetallic corrosion since it prevents appearance of moisture on contact points. The contacts are
protected with electrical contact grease. When shear head nut of ATOM insulated piercing Connector is tightened the teeth of contact plates pierce the
insulation of LV ABC and achieve excellent contact thanks to deep breakthrough into the conductor and large contact area. Contact plates are made of
electrolytic metal sheet of excellent conductivity and very high tensile strength so that piercing of the insulation is possible even at very low temperatures.
Tightening of ATOM insulated piercing Connector is done until mechanical damage of shear head nut. Additional tightening is allowed until maximum
mechanical load, maximum 1,5 circle from the moment of damage of shear head nut. Installation under voltage is possible but proper protective
equipment must be used. ATOM Insulated piercing Connector is designed in such a way that fast, easy and reliable installation is possible regardless of
the outside temperature. The housing is made of Polyamide PA 6 (reinforced with 30-50% glass fibers). resistant to UV radiation, weather conditions,
temperature oscillations, aging. ATOM insulated piercing connector:
-does not contain parts which can fall of .
-can be used-installed only once.
Has and rotation device –ARD ,which enables easy and proper installation because it dose not allow rotation of the upper and the lower part of the
connector around its axis, which results in easy and deep break through of contact plates into the insulation of LV ABC during installation. The most i
mportant norms that ATOM insulated piercing connector fulfills: Testing of installation at low temperature -9 C -13 C and tightening at 0,7 of tensile force .
Check of mechanical effect of contact plates on the firmness of main insulated conductor. Check of mechanical force limiter -shear head nut, timely contact
establishment (0,7 of minimum tensile force) and mechanical durability of the connector (1,5 of maximum tensile force).
Testing of dielectric strength by immersing the connector into the water for the period of 30 minutes under voltag of 6kv.
Testing of environmental effects, carrion test , electrical aging test. Check of indelibility of mark.

26
INSULATED PIERCING CONNECTORS
IPC 1,5-10/16-95 MM2 CESP/CNT 95
ATOM insulated piercing Connector CESp/CNT 95 is used to achieve contact by
simultaneously piercing the insulation on LV ABC conductors of main power distribution
line and on LV ABC conductors of street lighiting connection line or other small electricity
consumer.
Maximum allowed tensile force: 12 Nm.
Nominal tensile force: 10 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 16mm² to 95mm².
Cross section of the tap-off line 1,5mm² to 10mm².

IPC 1,5-35/6-150 MM2²CES/CNT 150


ATOM insulated piercing CES/CNT is used to achieve contact by simultaneously piercing
the insulation on LV ABC conductors of main power distribution line and on LV ABC
conductors of street lighting connection line or other small electricity
consumer.
Packaging 50 pieces .
Connector weight 7,80kg/100 pieces.
Maximum allowed tensile force: 12 Nm.
Nominal tensile force: 10 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 6mm2 to 150mm2.
Cross section of the tap-off line 1,5mm2 to 35mm2.

27
IPC 4-50/35-150 MM2 CBS/CT 150
Connector CBS/CT 150 is used to achieve contact by simultaneously piercing the
insulation on LV ABC conductors of main power distribution line and on LV ABC network
connection conductor.
Maximum allowed tensile force:16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 35mm² to 150mm²
Cross section of the tap-off line 4mm² to 50mm²

IPC CBS/CT 95; CBSP/CNT 95 2,5-35/16-95MM 2

ATOM insulated piercing Connector CBS/CT 95, CBSp/CNT 95 is used to achieve contact
by simultaneously piercing the
insulation on LV ABC conductors of main power distribution line and on LV ABC network
connection conductor.
Maximum allowed tensile force:16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 16mm² to 95mm²
Cross section of the tap-off line 2,5mm² to 35mm²

28
INSULATED PIERCING CONNECTORS
IPC 16-95/16-95MM ²CDRS P/CNT 95
2

ATOM Insulated Piercing Connector CDRS p/CNT 95 is used to achieve contact by


simultaneously piercing the insulation on LV ABC conductors of main power distribution line,
on conductors of two consecutive main fines or conductors of high power connection line.
Maximum allowed tensile force: 16Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 16mm² to 95mm²
Cross section of the tap-off line 16mm2 to 95mm2

IPC 6-70/16-95MM ² M2 IOS


2

ATOM Insulated piercing Connector M2 IOS is used to achieve contact by simultaneously


piercing the insulation on LV ABC conductors of main power distribution line, on conductors
of two consecutive main lines or conductors of high-power connection line.
Maximum allowed tensile force:16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 16mm² to 95 mm²
Cross section of the tap-off line 6mm² to 70mm²

29
IPC CBS P/CN 95 2,5-35/16-95MM2²2P
ATOM Insulated Piercing Connector CBSP/CN 95 2p is used to achieve contact by simultaneously
piercing the insulation on LV.
ABC conductors of main power distribution line and on LV ABC network connection conductor
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 16mm2 to 95mm2
Cross section of the tap-off line 2,5mm2 to 35mm2

IPC 25-150/25-150 MM2 2P CDRS P/CNT 150 2P


ATOM Insulated Piercing Connector CDRSP/CNT 150 2p is used to achieve contact by
simultaneously piercing the insulation on LV ABC conductors of main power distribution line, on
conductors of two consecutive main lines or conductors of high power connection line.
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 25mm2 to 150mm2
Cross section of the tap-off line 25mm2 to 150mm2

30
INSULATED PIERCING CONNECTORS
IPC 25-150/25-150 MM 2
1P CDRS P/CNT 150 1P
ATOM Insulated Piercing Connector CDRSP/CNT 150 2p is used to achieve contact by
simultaneously piercing the insulation on LV ABC conductors of main power distribution line, on
conductors of two consecutive main lines or conductors of high power connection line.
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 25mm2 to 150mm2
Cross section of the tap-off line 25mm2 to 150mm2

IPC 25-185/50-240 MM 2
CDRS P/CNT 240 2P
ATOM Insulated Piercing Connector CDRSP/CNT 240 2p is used to achieve contact by simultaneously
piercing the insulation on LY ABC conductors of main power distribution line, on conductors of two
consecutive main lines or conductors of high power connecion line.
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 50 mm2 to 240 mm2
Cross section of the tap-off line 25mm2 to 185mm2

31
IPC 25-185/50-240 MM 2
CDRS P/CNT 240 2P
ATOM Insulated Piercing Connector CDRSP/CNT 240 2p is used to achieve contact by
simultaneously piercing the insulation on LY ABC conductors of main power distribution
line, on conductors of two consecutive main lines or conductors of high power connecion
line.
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 50 mm2 to 240 mm2
Cross section of the tap-off line 25mm2 to 185mm2

IPC WITH PIERCING OF THE INSULATION ON TAP-OFF CONDUCTOR


ATOM Insulated Piercing Connector CDRSP/CNT 240 2p is used to achieve contact by
simultaneously piercing the insulation on LY ABC conductors of main power distribution *4-50/25-150 *6-95/16-150 *6-95/16-150
line, on conductors of two consecutive main lines or conductors of high power connecion
line.
Maximum allowed tensile force: 16 Nm.
Nominal tensile force: 12 Nm.
Force at which first contact is established: 4 Nm.
Range of use:
Cross section of the main line 50 mm2 to 240 mm2 *16-150/16-150 *2,5-35/16-120 *6-95/16-150
Cross section of the tap-off line 25mm2 to 185mm2

32
MISC. PARTS

33
INSULATED WATERPROOF ADAPTER
Insulated Waterproof Adapter is used with all types of Insulated Piercing
Connectors. Installation Wrench / Dismantling Wrench 13 *.

AERIAL FUSE-HOLDER
Aerial Fuse-holder is used to protect street lighting power distribution
lines and bare overhead power distribution lines connected to LV ABC
lines from overcurrent. It is made of high quality materials resistant to
mechanical and atmospheric impacts and UV radiation.

INSULATED CONNECTOR IOS 3 AL-CU 16_70MM 2


/ ALCU 4×(6_35 MM2)
Insulated Connector IOS 3 if used to achieve contact by piercing the Insulation on LV ABC.
conductors and to joint network connection or street lighting conductors. The connector is made in such a way that it enables
jointing of LV ABC and network connection line regardless of whether it is aluminum or copper conductor.
when the nut is tightened the teeth of contact plates pierce the insulation and establish excellent joint on the main line
without need to remove insulation. It is possible to derive 1-4 network connection lines where the insulation is removed in the
length of 18mm. Tightening torque of the connector is 18 Nm. The contacts are protected with electrical contact grease. The
connector can be used/installed only once. Range of use:
Cross section of the main line 16 to 70mm2
Cross section of the tap-off line 6 to 35mm2

34
MISC PARTS
INSULATED CONNECTOR IOS 4 AL 16-70 MM 2
/ ALCU 2×(6-35 MM2)
Insulated Connector IOS 4 is used to achieve contact by piercing the insulation on LV ABC.
conductors and to joint network connection or street lighting conductors. The connector is made in such a
way that it enables jointing of LV ABC and network connection line regardless of whether it is aluminum or
copper conductor When the nuts tightened the teeth of contact plates pierce the insulation and establish
excellent joint on the main line without need to remove insulation.
It is possible to derive 1-2 network connection lines where the insulation is removed in the length of 18mm.
Tightening torque of the connector is 14 Nm.
The contacts are protected with electrical contact grease.
The connector can be used/installed only.
Range of use:
Cross section of the main line 16 to 70 mm2
Cross section of the tap-off line 6 to 35 mm2

IPC TYPE M
Insulated Connector IOS 4 is used to achieve contact by piercing the insulation on LV ABC.
conductors and to joint network connection or street lighting conductors. The connector is made in such a
way that it enables jointing of LV ABC and network connection line regardless of whether it is aluminum or
copper conductor When the nuts tightened the teeth of contact plates pierce the insulation and establish
excellent joint on the main line without need to remove insulation.
It is possible to derive 1-2 network connection lines where the insulation is removed in the length of 18mm.
Tightening torque of the connector is 14 Nm.
The contacts are protected with electrical contact grease.
The connector can be used/installed only.
Range of use:
Cross section of the main line 16 to 70 mm2
Cross section of the tap-off line 6 to 35 mm2

35
Wall Mount Cable Support BRF
Wall Mount Cable Support BRF is used to fasten LV ABC onto facade.

SADDLE CLIP 16 mm2


Saddle Clip is used for placing conductors along facades.
It is made of mechanically reliable technical plasics resistant to
UV radialon, ageing and environmental effects.
Maximum conductor diameter is 16 mm2.

PLASTIC TIE
Plastic Tie is widely used in order to prevent unraveling of the
conductors especially when ATOM Clamps PA 1500, PS 1500, PA
25 and PA 600 are installed. It is made of material resistant to UV
radiation.

36
MISC PARTS
CLIPS FOR STAINLESS STEEL BANDS
They are used to fix stainless steel band to the pole.

STAINLESS STEEL BAND


Stainless Steel Bands are used to fix ABC accessories to the poles.

ALUMINIUM BAND 10 1 2000 MM2


Stainless steel band is used to fix aluminium conductor steel reinforced ( ACSR) to
insulators by bending it around the conductor and insulators.

37
PLASTIC COATED ALUMINUM TIE
Plastic Coated Aluminum Tie is widely used to prevent unraveling of LV
ABC conductors. especially when ATOM Clamps PA 1500, PS1500,
PA 25, PA BO, UMS PAM 35, PAC 80, PA 25/2 and etc.

STAINLESS STEEL BAND


IN PLASTIC DISPENSER
It is used to fix LV ABC Accessories onto the poles.

38
MISC PARTS
UNIVERSAL INSULATED WRENCH FOR
INSULATED PIERCING CONNECTORS
Universal Insulated Wrench for Insulated Piercing Connectors is made of
high-quality thermoplastic material of excellent tensile strength and is used
for installation, tightening and dismantling of all types of insulated piercing
connectors as well as of Universal Clamp UMS PAM 35.
Universal Insulated Wrench has got four rings:10,13,17 and 22.

INSULATED ADAPTER FOR SHORT


CIRCUIT AND GROUNDING PMCC
Insulated adapter for short circuit and grounding is installed via Insulated
Piercing.
Connector Type CBS or CDRS.
The Adapter is installed on the tap-off side of the Insulated Piercing Connec-
tor Type CBS or CDRS.
Insulated adapter PMC has markings on its outside and their selective re-
moval marks on which phase or neutral conductor the connector has been
installed.
Water resistance is tested in water, under voltage of 6 kV during 30 minutes.
Its made for short circuit current up to 4 kA/s, of constant current up to
200A.
Before installing equipment for short circuit ad grounding it must be checked
whether overhead power distribution line is not under voltage.
At Custumer’s request adapter can be equipped with 35mm2 Cu cable.

39
END CAP
End Caps Type CECT made of elastomer are designed to be easily pulled
onto the conductor›s end thus preventing moisture penetrallon into
the conductor and at the same Kime provide its electrical insulaXon
from open-circuit voltage. They are made of material resistant to UV
radialon, tested in the water under voltage of 6 kV in accordance with
requirements of Standard NF C 33 020. End Caps are delivered with ATOM
ELECTRIC.
CECT 16- 95
CECT 4- 50
CECT 70- 150
CECT 50- 185

Protection cap
Protection Caps Type CECT made of elastomer are designed to be easily
pulled onto the conductor’s end thus preventing moisture penetration
into the conductor and at the same time provide its electrical insulation
from open-circuit voltage.
They are made of material resistant to UV radiation, tested in the
water under voltage of 6kV in accordance with requirements of Standard
NF C 33 020.

40
TELECOMMUNICATION
CABLES
ACCESSORIES

41
MISC PARTS
ALUMINUM BRACKET CAB 25
Aluminum Bracket CAB 25 is used for receiving LV ABC across Anchoring
Clamp PA 25, PAC 80, PA 80, UMS PAM 35, PA 2-25 or similar technical
solutions for anchoring clamps. It has high tensile strength and is made
of aluminum alloy.
Its design provides easy, fast and reliable installation in two ways - with
stainless steel band or with M10 bolt.
Minimum breaking strength is 4 kN.

ANGULAR SUSPENSION CLAMP PS 300 ADSS


Angular Suspension Camp PS 300 ADSS is used to receive cable diameter
from 1mm to 22mm in order to cary and optionally allow change of the
route direction. It is resistant to environmental and mechaical effects
and UV radiation since it is made of material of high tensile strength and
stable structure. Minimum breaking force is 3 KN. It is installed using no
tools and does not contain parts which can fall off.

42
Dead end clamp pa 1500 Adss
Dead End Clamp PA 1500 ADSS is used for tightening ADSS cables. Its
design provides easy, fast and reliable installation in all weather conditions. It is
installed using no tools and do not contain parts which can fall off. Dead
End Clamp PA 1500 ADSS consists of the body casted of aluminum alloy and
self-adjusting plastic wedges which tighten the conductor without insulation
damage. All parts of Dead End Clamp PA 1500 ADSS are resistant to corrosion,
environmental effects and UV radiation. Maximum turning angle is 45 degrees
for one-sided tightening and 90 degrees for two-sided tightening.
Minimum breaking strength is 15 kN. The Clamp is delivered with hot-dip
galvanized or stainless steel cord on Customer’s request

ANCHORING CLAMP DN 525


Anchoring clamp DN 525 ADSS is used with cables of different construction
and of section size from Ø1mm to Ø25mm.
Anchoring clamp DN 525 is made of top quality material of high mechanical
strength and resistance to environmental effects and UV radiation.
It is type tested and certified according to all standards relevant for cable
accessories.
Inside canals of anchoring clamp DN 525 are cogged and they have excellent
mechanical contact with conductor insulation, which prevents slippage and
provides an effect of extremely reliable tightening. Minimum breaking force
is 4,5 kN.
The clamp is installed without additional tools.
The clamp does not contain parts which can fall off.
The clamp has a built-in system for compensation of cyclic forces such as
strong winds and similar cyclic loadings.
The clamp has a unique feature to hold two conductors independently.
After the first conductor has been fitted the second conductor can be added
easily. 43
TELECOMMUNICATION CABLES ACCESSORIES
SERVICE ANCHORING CLAMP DN ADSS
Service Anchoring Clamp DN ADSS is used for different cables of cross sections between Ø 1mm and Ø 18mm. Service Anchoring Clamp DN ADSS
is made of high-quality materials of high tensile strength and resistance to environmental effects and UV radiation.
It is tested and certified so that it complies with all standards for cable accessories. Inside canals of Service Anchoring Clamp DN are cogged
so that they have excellent mechanical contact with conductor’s insulation thus disabling slippage and the effect of most reliable tightening is
achieved Minimum breaking force is 2 kN. On Customer’s request metal parts can be hot-dip galvanized or stainless steel.

44
NON-INSULATED
NETWORK ACCESSORIES

45
PARALLEL Al-Al GROOVE CLAMP H-FORM
They are used to joint two parallel non-insulated aluminum conductors of the
same or different cross sections. The conductors can be made of aluminum
alloy (AAAC) aluminum conductors steel reinforced (ACSR) or ends of ABC from
which the insulaltion has been removed. Their technical characteristics enable easy
formation of joints in accordance with Standard DIN 48 072. They are made using
extrusion process and the inside grooves are cogged,which increases safety regarding
pulling out and provides high-quality electrical contact (the grooves are made in such
a way that aluminum oxide from the conductor surface is broken, which reduces
transitional resistance between the clamp and the conductor). The body of the clamp is made
of aluminum alloy of high tensile strength and is corrosion resistant. Its technical characteristics
provide fast, easy and reliable installation and there are no parts that can fall off.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or stainless
steel X 5 CrNi 18-10 bolt parts.

PARALLEL GROOVE CLAMP Al-CU H-FORM


They are used to joint two parallel non-insulated conductors of the same or different cross
sections. The conductors can be made of aluminum alloy (AAAC),aluminum conductors
steel reinforced (ACSR) or coppers conductor. Their technical characteristics enable easy
formation of joints in accordance with Standard DIN 48 072. They are made using forging process
and the inside grooves are cogged,which increases safety regarding pulling out and provides
high-quality electrical contact .The body of the clamp is made of brass of high tensile strength
and is corrosion resistant. Its technical characteristics provide fast, easy and reliable installaion
and there are no parts that can fall off. Surface protection is done using the process of zinc
plating. NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or
stainless steel X 5 CrNi 18-10 bolt parts.

46
NON-INSULATED NETWORK ACCESSORIES
PARALLEL CU-CU GROOVE CLAMP H-FORM
They are used to joint two parallel non-insulated copper conductors of the same or different
cross sections. Their technical characteristics enable easy formation of joints in accordance
with Standard DIN 48 072/2. They are made using forging process and the inside grooves
are cogged, which increases safety regarding pulling out and provides high-quality electrical
contact. The body of the clamp is made of copper of high tensile strength and is corrosion
resistant. Its technical characteristics provide fast, easy and reliable installation using only one
wrench and there are no parts that can fall off.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or stainless
steel X 5 CrNi 18-10 bolt parts.

PARALLEL ME Al-CU GROOVE CLAMP

They are used to joint two parallel non-insulated aluminum conductors of the same. or
different cross sections. The conductors can be made of aluminum alloy (AAAC) or Cu, alloy aluminum
conductors steel reinforced (ACSR) or ends of ABC from which the insulation has been removed. Their
technical characteristics enable easy formation of joints in accordance with Standard DIN 48 072. They
are made using forging process and the inside grooves are cogged, which increases safety regarding
pulling out and provides high-quality electrical contact (the grooves are made in such a way that
aluminum oxide from the conductor surface is broken, which reduces transitional resistance
between the clamp and the conductor). The body of the clamp is made of aluminum alloy of high
tensile strength and is corrosion resistant. Its technical characteristics provide fast, easy and reliable
installation, using only one wrench, and there are no parts that can fall off.
NOTE: On customer’s request the clamps can be delivered with hot-dip galvanized or stainless steel X
5 CrNi 18-10 bolt parts.

47
BIMETAL Al-CU GROOVE CLAMP
They are used to joint two parallel non-insulated conductors when the main fine is AAAC or ACSR and
tap-off line is copper conductor. Their technical characteristics provide fast, easy and reliable installa-
tion using only one wrench and there are no parts that can fall off.
They are made of special aluminum alloy of high tensile strength and good electrical conductivity.
The copper insert is made of electrolytic copper sheet and the way it is built into the clamp prevents
moisture permeation between copper and aluminum part thus disabling occurrence of bimetallic
corrosion, which guarantees excellent electrical conductivity.
Clamping plate of aluminum conductor is made of aluminum sheet AlMg3.
Clamping plate of copper conductor is made of electrolytic copper sheet 2 mm or Zinc plated steel
sheet 2 mm, depending on the customer’s request.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or Stainless steel
X 5 CrNi 18-10 bolt parts.

TERMINAL Al-Al CLAMP


Terminal AIAI Clamps are used at the ends of non-insulated aluminum conductors for termination of
lines as well as for their jointing, They are made of specific aluminum alloy and enable maximum
allowed load of aluminum conductors steel reinforced (ACSR).
The inside grooves are cogged, which disables slippage of conductors under normal and maximum
allowed loads.
grooved canals increase tensile strength and contact. Bolts and nuts are Zinc plated and resistant to
corrosion as well as the clamp itself.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or stainless steel
X 5 CrNi 18-10 bolt parts.

48
NON-INSULATED NETWORK ACCESSORIES
TERMINAL CU-CU CLAMPS
Terminal CuCu Clamps are used at the ends of non-insulated copper conductors for termination of
lines as well as for their jointing.
They are made of copper alloy and enable maximum allowed load of copper conductors.
The inside grooves are cogged, which disables slippage of conductors under normal and maximum
allowed loads.
Grooved canals increase tensile strength and improve contact.
Bolts and nuts are Zinc plated and resistant to corrosion as well as the clamp itself.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or stainless steel
X 5 CrNi 18-10 bolt parts.

AlAl GROOVE CLAMP


AIAl Groove Clamps are used to joint two parallel aluminum alloy conductors (AAAC),aluminum
conductors steel reinforced(ACSR) or ends of ABC of the same or similar cross sections from which the
insulation has been removed. Their technical characteristics enable jointing of phase conductors at the
places where high tensile strength and stiffness is required (joint done in accordance with Standard
DIN 48 075). AIAl Groove Clamps are made using die casting process and the inside grooves are cogged,
which increases safety regarding pulling out and provides high-quality electrical contact (the grooves
are made in such a way that aluminum oxide from the conductor surface is broken, which reduces
transitional resistance between the clamp and the conductor). The body of the clamp is made of
aluminum alloy of high tensile strength and is corrosion resistant. Their technical characteristics provide
fast, easy and reliable installation and long-life and safe usage with minor losses on the network due to
very low transitional resistance. Bolts and nuts are Zinc plated.
Inside grooves are protected with electrical contact grease.
NOTE: On Customer’s request the clamps can be delivered with hot-dip galvanized or stainless steel X 5
CrNi 18-10 bolt parts.

49
MEPOS CLAMP
MEPOS clamps are used to achieve contact between all types of aluminum and copper
conductors and flat conductors copper trays in enclosures. Cogged surfaces of MEPOS
Clamp provide high-quality contact. The Clamps are made using forging process and are
Zinc plated. They are widely used on switchboards in street lighting poles.

EARTHING SQUARE TAPE CLAMP

Earthing Square Tape Clamp is used to interconnect earthing tapes, round earthing conductors or to connect
earthing tapes and round earthing conductors.
NOTE: On Customer’s request the earthing Tape Clamps can be made of copper sheet, which is suitable when
lighting protection system uses copper tapes and conductors.

50
NON-INSULATED NETWORK ACCESSORIES
EARTHING CLAMP
Earthing Clamp is used to achieve reliable and very strong connection between earthing tapes
or round conductors.
The Clamp is made of brass and is zinc plated.

INSULATION PLASTIC COVER


Insulated plastic cover is used for the following types of ATOM non-insulated clamps: MAI, MAIAL, MMs,
MCu, MEAICU, MAICu.
It provides safe protection against touch voltage. It is resistant to atmospheric and mechanical impacts
and UV radiation because itis made of material of high tensile strength and stable structure in all weather
conditions.

51
NOTE

52
NOTE

53
54

You might also like