You are on page 1of 15

Annex 1 of the European Technical Approval No ETA-06/0006 26

STANDARD ANCHORAGE PARTS

WEDGES

COMPRESSION FITTING
Annex 1 of the European Technical Approval No ETA-06/0006 27

STANDARD ANCHORAGE PARTS

ANCHOR HEADS TYPE E


Annex 1 of the European Technical Approval No ETA-06/0006 28

STANDARD ANCHORAGE PARTS

ANCHOR HEADS TYPE CS


Annex 1 of the European Technical Approval No ETA-06/0006 29

STANDARD ANCHORAGE PARTS

PROTECTIVE CAPS FOR ANCHORAGES TYPE E AND TYPE CS

Unit ØA B C D
6-3 78 165 30 63
6-4 89 190 40 62
6-7 116 230 40 63
6-12 155 290 50 63
6-15 185 310 40 63
6-19 190 340 40 63
6-27 230 370 40 63
6-31 235 450 40 65
6-37 260 480 40 65
6-43 290 540 40 65
6-55 320 600 40 65

Unit ØA B C D
6-3 103 160 50 110
6-4 119 195 50 115
6-7 153 255 60 120
6-12 190 310 70 135
6-15 207 320 70 145
6-19 223 325 70 155
6-22 244 345 70 160
6-27 258 375 70 170
6-31 287 405 70 180
6-37 309 480 90 195
6-43 346 535 90 205
6-55 389 585 90 220

Unit ØA ØB C(CS) C(E)

6-7 209 170 112 112


6-12 243 201 113 130
6-19 283 234 114 150
6-27 341 279 140 180
6-31 370 300 150 210
6-37 396 325 160 210
Annex 1 of the European Technical Approval No ETA-06/0006 30

ANCHORAGE TYPE E

CATEGORIES OF USE ARRANGEMENTS


PRINCIPLES:
Annex 1 of the European Technical Approval No ETA-06/0006 31

ANCHORAGE TYPE E

SIZES

Units A ØB C ØD E F G ØH ØI J K
6-1 75 18 10 53 50 80 150 25 21/25 86 Ø5
6-2 110 50 10 90 50 80 200 50 21/25 136 Ø5
6-3 135 56 15 95 50 80 205 55 21/25 125 M10
6-4 160 65 20 110 55 85 210 60 21/25 150 M16
6-7 205 84 30 135 60 90 320 72 28/32 210 M16
6-12 270 118 40 170 75 105 500 92 28/32 265 M16
6-15 305 143 45 190 85 115 585 97 28/32 275 M16
6-19 340 150 50 200 95 125 640 107 28/32 280 M16
6-22 370 172 55 220 100 130 745 122 28/32 300 M16
6-27 410 185 60 240 110 140 690 132 28/32 330 M16
6-31 435 192 65 260 120 150 755 142 28/32 360 M16
6-37 480 215 75 280 135 165 905 155 28/32 435 M16
6-43 520 248 80 300 145 175 1030 165 28/32 490 M16
6-55 580 255 95 340 160 190 1045 185 28/32 540 M16

J : Fixation holes (to shuttering) spacing.


Annex 1 of the European Technical Approval No ETA-06/0006 32

ANCHORAGE TYPE E

BURSTING REINFORCEMENT

Reinforcement for concrete with f cm(t) 23/28 N/mm² when stressing


SPIRAL REINFORCEMENT ORTHOGONAL REINF.
Units ØN n P ØQ M L ØR r S T
6-1 8 1 70 74 14 8 2 80 100
6-2 10 2 60 124 15 8 3 60 150
L = (Number of turns - 1) * P

6-3 10 2 75 155 20 10 4 55 185


6-4 10 3 65 185 25 10 4 55 220
6-7 12 4 60 260 36 12 4 75 295
6-12 16 5 70 345 46 12 7 70 390
6-15 16 6 75 390 51 16 8 75 435
6-19 16 7 60 450 58 16 6 90 495
6-22 16 8 60 490 63 16 7 75 535
6-27 16 9 55 545 68 16 8 70 595
6-31 16 10 55 585 73 16 10 60 635
6-37 20 9 65 645 85 16 9 75 695
6-43 20 11 60 705 90 16 10 70 750
6-55 20 12 60 805 105 16 15 55 855
Reinforcement steel f yk 500 N/mm².

n : Number of turns if the last one is welded else n + 1 if the last one is opened.
r : Number of reinforcement layers.

Reinforcements shown on this form was placed in test specimens for load transfer tests (see § 3.6).
Annex 1 of the European Technical Approval No ETA-06/0006 33

ANCHORAGE TYPE CS

CATEGORIES OF USE ARRANGEMENTS


Annex 1 of the European Technical Approval No ETA-06/0006 34

ANCHORAGE TYPE CS

SIZES

Unit ØA B C ØD E F1 ØF4 F2 ØF4 ØF3 G ØH I


6-7 222 60 136 143 50 225 80 360 63 85 80 188 M12
6-12 258 80 149 178 60 392 95 530 81 117 90 220 M12
6-19 300 90 170 210 70 540 110 660 106 148 100 260 M12
6-27 360 110 203 256 69 660 139 810 121 181 100 310 M16
6-31 390 122 217 274 69 620 149 740 136 188 100 330 M16
6-37 420 130 236 300 82 805 149 925 136 211 110 357 M16

F1: CS STANDARD length.


F2: CS PLUS and SUPER length.
ØH : Spacing of holes for fixation to formwork.
I : Thread hole.
: ØF4 for F2
Annex 1 of the European Technical Approval No ETA-06/0006 35

ANCHORAGE TYPE CS

BURSTING REINFORCEMENT

Reinforcement for concrete with f cm(t) 28/35 N/mm² when stressing


SPIRAL REINFORCEMENT ORTHOGONAL REINF.
Unit ØN n P ØQ M L ØR r S T
6-7 12 4 60 260 50 10 5 50 295
L = (Number of

6-12 16 5 65 345 30 12 8 60 390


turns - 1) * P

6-19 16 7 60 450 30 16 8 65 495


6-27 16 9 55 545 30 16 11 50 595
6-31 16 10 55 585 30 16 13 45 635
6-37 20 9 65 645 30 16 12 50 695
Reinforcement steel f yk 500 N/mm².

n : Number of turns if the last one is welded else n + 1 if the last one is opened.
r : Number of reinforcement layers .

Reinforcements shown on this form was placed in test specimens for load transfer tests (see § 3.6).
Annex 1 of the European Technical Approval No ETA-06/0006 36

ANCHORAGE TYPE H

SIZES AND BURSTING REINFORCEMENT

Anchorage size H6-4 L/2 As,min= 10 cm²/m L/2 Reinforcement as per


anchorage side
L

Reinforcement for concrete with f cm(t) 28/35 N/mm² when stressing


Unit A B A B C D D1 ØE ØF ØG ØH
Arrangement 1 Arrangement 2
6-1 90 90 1 - - - - - 950 - - - 16/20
6-3 290 90 3 - - - - - 950 - - 64 21/25
6-4 390 90 4 210 190 4 - - 950 - - 70 28/32
6-7 450 90 4 230 210 5 155 1300 1150 200 16 83 28/32
6-12 430 230 8 - - - 155 1300 1150 230 16 114 28/32
- - - 390 330 12 -
6-15 450 230 9 370 370 9 155 1300 1150 300 16 130 28/32
6-19 570 230 10 470 390 16 155 1300 1150 300 16 140 28/32
6-22 690 230 12 - - - 155 1600 1450 350 16 146 28/32
- - - 490 470 20 1400 1250
6-27 690 260 17 - - - 155 1650 1500 350 16 171 28/32
- - - 530 510 20 1600 1450
6-31 810 260 14 - - - 165 1900 1750 400 20 171 28/32
- - - 570 510 20 1700 1550
6-37 1050 370 18 - - - 175 2550 2400 400 20 178 28/32
- - - 690 510 24 2000 1850
Reinforcement steel f yk 500 N/mm ²
Number of Strand with lenght D1
Annex 1 of the European Technical Approval No ETA-06/0006 37

ANCHORAGE TYPE H
ARRANGEMENT AND CONCRETE DIMENSION
Unit 6-1 1 6-3 1 6-4 1 6-4 2
Arrangement
Front view

Unit 6-7 1 6-7 2 6 - 12 1 6 - 12 2


Arrangement
Front view

Unit 6 - 15 1 6 - 15 2 6 - 19 1 6 - 19 2
Arrangement
Front view

Unit 6 - 22 1 6 - 22 2 6 - 27 1 6 - 27 2
Arrangement
Front view

Unit 6 - 31 1 6 - 31 2 6 - 37 1 6 - 37 2
Arrangement
Front view

f cm(t) 28/35 N/mm² when stressing


Annex 1 of the European Technical Approval No ETA-06/0006 38

COUPLER TYPE K

SIZES

Unit A B C ØD ØE F ØG ØH
6-3 430 160 200 150 62 15 76 28/32
6-4 440 160 210 160 67 15 83 28/32
6-7 560 160 310 190 77 20 95 28/32
6-12 660 160 400 240 97 25 121 28/32
6-15 770 160 510 270 102 25 133 28/32
6-19 770 160 510 280 112 25 146 28/32
6-22 910 160 610 310 122 25 159 28/32
6-27 980 180 655 350 132 35 168 28/32
6-31 970 180 625 360 142 35 178 28/32
6-37 1200 200 830 400 155 35 203 28/32
Annex 1 of the European Technical Approval No ETA-06/0006 39

BLOCK OUT DIMENSIONS FOR ANCHORAGE TYPE E AND TYPE CS

CLEARANCE REQUIREMENTS

Unit Jack ZPE A B ØC D E ØF G


6-1 ZPE-30 135 53 600 100 140 1100
ZPE-23FJ 135 53 300 90 116 1200
6-2 ZPE-60 170 90 650 140 180 1100
6-3 ZPE-60 195 95 650 140 180 1100
6-4 ZPE-7A 220 110 800 200 280 1350
According to the end zone arrangement

6-7 ZPE-12St2 305 135 670 200 310 1300


ZPE-200 1100 210 315 2100
6-12 ZPE-19 370 170 850 250 390 1500
6-19 ZPE-460/31 460 200 700 300 435 1500
ZPE-500 1150 330 550 2000
ZPE-500K 700 315 508 1500
6-22 ZPE-500 530 220 1150 330 550 2000
6-31 ZPE-750 595 260 1350 365 570 2300
ZPE-1000 1300 450 790 2200
6-37 ZPE-1000 640 270 1300 450 790 2200
ZPE-1250 1350 375 620 2250
6-43 ZPE-1000 680 250 1350 450 570 2300
ZPE-1250 1350 375 620 2250
6-55 ZPE-1000 760 255 1300 450 790 2200
ZPE-1250 1350 375 620 2250

Unit Jack ZPE A B ØC D E ØF G


6-7 ZPE-12St2 360 105 700 200 310 1300
ZPE-200 1100 210 330 2100
According to the end

6-12 ZPE-19 420 130 850 250 390 1500


zone arrangement

6-19 ZPE-460/31 300 150 700 300 485 1500


ZPE-500 1150 330 585 2000
ZPE-500K 700 315 508 1500
6-27 ZPE-750 520 185 1350 365 570 2300
6-31 ZPE-750 550 190 1350 365 570 2300
6-37 ZPE-1000 580 215 1300 450 790 2200
ZPE-1250 1350 375 620 2250

460 if ZPE-500K is used.


600 if ZPE-1250 is used.
Annex 1 of the European Technical Approval No ETA-06/0006 40

Duct Smooth steel Plastic duct Plastic duct


Corrugated steel
DUCTING Strand Unit VSL PT-PLUS duct for bare for Sheathed
strip sheath
No Strand Strand
Øint /Øext e Øint /Øext e Øext x t Øext x t min Øext x t min
1 6-1 25/30 5 23/25 4
2 6-2 40/45 9
3 6-3 40/45 6
4 6-4 45/50 7
5 6-7 50/57 8 58/63 13
6 55/62 9 58/63 11
7 55/62 7 58/63 9
8 6-12 65/72 11 76/81 18
9 65/72 9 76/81 16
10 70/77 11 76/81 15
11 70/77 9 76/81 13
12 75/82 11 76/81 12
13 6-15 80/87 13 100/106 25
14 80/87 11 100/106 24
15 80/87 10 100/106 23
16 6-19 85/92 12 100/106 22
17 85/92 11 100/106 20
18 90/97 13 100/106 19
19 90/97 12 100/106 18
20 6-22 100/107 17 100/106 17
21 100/107 16 100/106 16
22 100/107 15 100/106 15
23 6-27 100/107 14 115/121 22
24 100/107 13 115/121 22
25 110/117 18 115/121 21
26 110/117 17 115/121 21
27 110/117 16 115/121 20
28 6-31 110/117 15 130/136 27
29 120/127 21 130/136 27
30 120/127 20 130/136 26
31 120/127 19 130/136 25
32 6-37 120/127 18 130/136 24
33 120/127 17 130/136 23
34 120/127 16 130/136 22
35 130/137 22 130/136 22
36 130/137 21 130/136 21
37 130/137 20 130/136 20
38 6-43 140/147 25 150/157 31
39 140/147 24 150/157 30
40 140/147 23 150/157 9
41 140/147 23 150/157 29
42 140/147 22 150/157 28
43 140/147 21 150/157 27
44 6-55 150/157 27 150/157 27
45 150/157 27 150/157 27
46 150/157 26 150/157 26
47 150/157 25 150/157 25
48 150/157 24 150/157 24
49 150/157 23 150/157 23
50 160/167 29 150/157 24
51 160/167 28 150/157 23
52 160/167 27 150/157 22
53 160/167 27 150/157 22
54 160/167 27 150/157 22
55 160/167 26 150/157 21
Øext. of corrugations. Use next larger duct for strong deviation and long cables.
The corrugated steel strip sheaths of diameters larger than 130 mm follow the design of EN 523 with the same strip thickness.
Øext. of duct.
According to standard EN 10255, EN 10216-1, EN 10217-1, EN 10219-2 and EN 10305-3. Values given for information only. Design defines ducts.
According to standard EN 12201, material PE 80. Values given for information only. Design defines ducts.