You are on page 1of 1

LAB Configuration

Diagram

Area 0.0.0.1
192.168.6.2
AP-1000-5
Int.2.1
SD

SLOT 3 COM 1
(PCI) !

Slot.1.1
ERROR
SLOT 4 SLOT 1 (PMC) SLOT 1 (PMC)
(PCI) ALERT COM 2
RPSU

192.168.6.1
POWER

AUXILIARY POWER

192.168.5.2 LB: 172.16.10.1 Int.1.1 192.168.10.1


192.168.18.2

AP-1000-4
192.168.2.2 192.168.5.1 Int.2.1
Int.1.1 SLOT 3
(PCI)

ERROR
! COM 1
SD

SLOT 4 SLOT 1 (PMC) SLOT 1 (PMC)

LB: 172.16.10.2
(PCI) ALERT COM 2
RPSU

(un) POWER

AUXILIARY POWER

192.168.16.1

0/5 -3
OC
7
Int.1.1
192.168.2.1 Area 0.0.0.0
AP-1000-1 (un) SD

SLOT 3 COM 1
(PCI) !
ERROR
SLOT 4 SLOT 1 (PMC) SLOT 1 (PMC)

LB: 172.16.11.1
(PCI) ALERT COM 2
RPSU
POWER

AUXILIARY POWER

Int.2.1 (un) T1
192.168.15.1 DLCI
500
DS 56

SD

192.168.4.2
0/

SLOT 3 COM 1
(PCI) !
-3

ERROR
SLOT 4 SLOT 1 (PMC) SLOT 1 (PMC)
(PCI) ALERT COM 2
RPSU
POWER

AUXILIARY POWER

LB: 172.16.11.2 (un)


Int.1.1 192.168.15.2 192.168.16.2 AP-1000-9
192.168.4.1 Int.2.1
AP-1000-3 (un) AP-1000-2 LB: 172.16.12.5
192.168.14.1
SD SD

SLOT 3
(PCI)

SLOT 4
ERROR
SLOT 1 (PMC) SLOT 1 (PMC)
! COM 1
OC-3 SLOT 3
(PCI)

SLOT 4
ERROR
SLOT 1 (PMC) SLOT 1 (PMC)
! COM 1

LB: 172.16.11.3
(PCI) ALERT COM 2 (PCI) ALERT COM 2
RPSU RPSU
POWER POWER

192.168.14.2 0/58
AUXILIARY POWER AUXILIARY POWER

(un) Int.1.1 Int.2.1 192.168.3.1


192.168.1.2
0/5 3
-
5
DS

OC-3
0/60
192.168.1.1
(un) AP-450
SLOT 3
(PCI) ! COM 1
SD

Int.1.1 Trainer Laptop 192.168.3.2


LB: 172.16.12.1 SLOT 4
(PCI)
ERROR
ALERT
RPSU
POWER
SLOT 1 (PMC) SLOT 1 (PMC)
COM 2

AUXILIARY POWER
192.168.12.2
Int.2.1 192.168.11.1 AP-1000-6
192.168.12.1
Int.1.1
(Trainer) Int.2.1 SD

SLOT 3
(PCI)

SLOT 4
ERROR
SLOT 1 (PMC) SLOT 1 (PMC)
! COM 1

(un)
192.168.11.4
(PCI) ALERT COM 2
RPSU

Hub
POWER

AUXILIARY POWER
SD

LB: 172.16.12.2 (un)D SLOT 3


(PCI)

SLOT 4
ERROR
SLOT 1 (PMC) SLOT 1 (PMC)
! COM 1

0/5 S3 192.168.13.2
(PCI) ALERT COM 2
RPSU
POWER

AUXILIARY POWER

9 Int.1.1 192.168.17.1
(un) 192.168.13.1 Int.1.1 AP-1000-8
192.168.11.2 SLOT 3
LB: 172.16.12.4
COM 1
SD

192.168.17.2
(PCI)

ERROR
SLOT 4 SLOT 1 (PMC) SLOT 1 (PMC)
(PCI) ALERT COM 2
RPSU

All Laptop computers:


POWER

AUXILIARY POWER

MAX: L2TP
LAC Win NT 4.0 SP4 AP-1000-7
192.168.11.3 IRE IPSec Client LB: 172.16.12.3
Lucent AccessView

Lab Configuration Edit Date: 08/21/00 10:54 PM PDT


Area 0.0.0.2
Description: Lab design for AccessPoint SE training. All loopback
addresses has a network mask of /32. All other have /24.

Contact: Rev: 2.0 Creator: Ramiro Salas


mg119@lucent.com
Filename: Lab Diagrams.vsd Company: Lucent Technologies