You are on page 1of 2

‫ م‬4:25 2023/‫‏‬7/‫‏‬11 SOP for Cleaning Procedure for UV-Visible Spectrophotometer

Home About Contact Terms & Conditions Disclaimer Privacy Policy

https://trkrspace.com/show.php?l=0&u=1461688&id=47569&tracking_id=

USP 2021 (United State Pharmacopeia


Home  Quality Control  SOP for Cleaning Procedure for UV-Visible Spectrophotometer
44 - NF 39)
 January 09, 2022

SOP for Cleaning Procedure for UV-Visible


USP 2023 (USP 46 –NF 41)
Spectrophotometer  May 23, 2023

 Anonymous  March 15, 2021

Types of Tooling in Compression


OBJECTIVE Machine
To lay down the procedure for cleaning of UV-Visible Spectrophotometer  May 28, 2020

SCOPE SOP for Preparation of Master


This SOP shall be applicable for UV-Visible Spectrophotometer installed in Quality Formula Record (MFR)
Control Laboratory at XYZ Limited  January 13, 2022

RESPONSIBILITY Tablet Scoring Study of Azithromycin


Execution: Chemist and above-QC department Tablets USP 500mg (Tablet Breakline
Study)
PEOPLE ALSO READ: How to take Spectrum in Shimadzu UV-1800 in UV Probe  January 04, 2022

Software?
SOP for Entry, Exit and Gowning
procedure for Powder Processing
PROCEDURE
Area
Frequency: After each use
 May 25, 2023
• After completion of the testing, remove cuvettes from the sample compartment.
• Remove the test solution from the cuvette and wash it with the respective
 ACCOUNTS 11 POSTS
solvent in which the solution is prepared.
•Rinse with purified water properly to remove the traces of the sample followed by  AHU 5 POSTS

methanol and wipe with tissue paper. Dry in the air and keep it in a proper place.
 AUDIT 16 POSTS
• Clean the sample compartment with a dry cloth to remove any foreign material
if required.  BUSINESS 25 POSTS

• Clean the outer surface of the instrument with Isopropyl alcohol and dry it with  CALIBRATION 1 POSTS
tissue paper when required.
 CLEANING 3 POSTS
•Record the details of cleaning in the log book of the instrument as per the
current version of SOP.  COSTING 4 POSTS

 EXPORT 1 POSTS
ABBREVIATION
SOP: Standard Operating Procedure
 FACEMASK 10 POSTS
Q.C: Quality control
 GPAT 1 POSTS
ANNEXURE
Nil  HUMAN RESOURCES 6 POSTS

REVISION HISTORY  INTERVIEW 9 POSTS


Nil
 STERILE 4 POSTS
PEOPLE ALSO READ: How to take Baseline in Shimadzu UV-1800 in UV Probe Software?
 VALIDATION 34 POSTS
Tags: Quality Control

USP 2021 (United State Pharmacopeia


 Facebook  Twitter     44 - NF 39)
 January 09, 2022

 OLDER NEWER 

https://www.pharmaceuticalsky.com/2021/03/sop-for-cleaning-procedure-for-uv.html 1/2
‫ م‬4:25 2023/‫‏‬7/‫‏‬11 SOP for Cleaning Procedure for UV-Visible Spectrophotometer
SOP for Behavior at Work Place SOP for Cleaning Procedure of Empty PVC Bottles USP 2023 (USP 46 –NF 41)
 May 23, 2023

Posted by: Anonymous Types of Tooling in Compression


Machine
 May 28, 2020

SOP for Preparation of Master


Formula Record (MFR)
YOU MAY LIKE THESE POSTS  January 13, 2022

SOP for Analytical Data Review


QU A L IT Y CON T R OL QU A L IT Y CON T R OL QU A L IT Y CON T R OL
 May 19, 2023

Tablet Scoring Study of Azithromycin


Tablets USP 500mg (Tablet Breakline
Relation between Assay and SOP for Forced Degradation SOP for Operation of Study)
Dissolution Testing Study Shimadzu RF-5301  January 04, 2022

 May 30, 2023  May 25, 2023 Fluorimeter


 May 15, 2023
Accounts AHU Analytical Method Audit

Books Business Calibration Cleaning

Cosmetics Costing COVID-19

Dexamethasone Engineering Export


POST A COMMENT
Facemask GPAT HPLC Human Resources

0 Comments Insurance Interview Maintenance

Marketing Microbiology Packing

Enter Comment Pharma Education Pharmacopeia

Product Development Production Qualification

Quality Assurance Quality Control sterile

Trading Validation Video Warehouse

ZyCoV-D

Mar 2021 (35)

Copyright © 2020-2023. Pharmaceuticalsky. All Right Reserved. Home About Contact Us DMCA

https://www.pharmaceuticalsky.com/2021/03/sop-for-cleaning-procedure-for-uv.html 2/2

You might also like