You are on page 1of 1

KEYPLAN

FOR CONTINUATION REFER DRAWING NO: IMK-C-163-SW-NW-TS-003 & 004

N
12 09

N 13 10
03 01

.257
IDS:2 .52
16 15

Ø500
07 05

L=23

ROOM
GUARD
14 11
IN1-33 04 02
G.L.=3.735 08 06
I.L.=2.244

2752350 N GENERAL NOTES:

5
L=24.22
IDS:2.19
Ø500
1. ALL COORDINATES ARE IN WGS 84, UTM ZONE 40N.
2. LEVELS ARE RELATED TO NEW ABU DHABI DATUM (NADD).

L=30.39
3. PIPE LENGTH, LEVELS AND DEPTHS ARE IN METERS.

Ø160

0
IDS:2.32
IN1-32 4. PIPE SIZES SHOWN ARE EXTERNAL DIAMETERS IN
G.L.=3.660 MILLIMETERS.
I.L.=2.141 5. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL
IC-26.3 THE COVER LEVELS AS PER FINAL FINISHED ROAD LEVELS
G.L.=3.736 AND MODIFY THESE COVER LEVELS ACCORDINGLY, IF

IDS:2.100
L=20.50
NECESSARY.

Ø500
I.L.=2.320
6. FOR DETAILS REFER TO ADM STANDARD DRAWINGS.
7. CONCRETE BED AND SURROUND PROTECTION SHALL BE
PROVIDED WHERE COVER TO PIPES IS LESS THAN 1.20m AND

IDS:2.290
L=29.72
IN1-31 WHERE SPECIFIED OR INSTRUCTED BY THE ENGINEER.

Ø160
G.L.=3.600
8. CONTRACTOR SHALL ENSURE THAT STORM WATER PIPE LINE
I.L.=2.100
AND MANHOLES ARE WITHIN THE ALLOCATED CORRIDOR. ANY
DISCREPANCY SHALL BE REPORTED TO THE ENGINEER WHILE

IDS:2.057
L=21.24
Ø500
FINALIZING THE SHOP DRAWINGS.

2752300 N
IC-26.4
LEGEND:
G.L.=3.645

FOR CONTINUATION REFER DRAWING NO: IMK-C-163-SW-NW-TS-006


I.L.=2.290 MARINE SETOUT
PROPOSED STORM WATER GRP PN10 SOLID PIPELINE

IDS:2.250
L=34.87
IN1-30

Ø160
PROPOSED SUBSOIL uPVC PN10 PERFORATED PIPELINE
G.L.=3.536 EXISTING STORM WATER PIPE LINE
I.L.=2.057 PROPOSED STORM WATER MANHOLE

IDS:1.997
PROPOSED INSPECTION CHAMBER (SUBSOIL DRAINAGE)

L=30.14
Ø500
PROPOSED INLET CHAMBER
PROPOSED CATCH BASIN
IC-26.5 PROPOSED PIPE END
G.L.=3.559 RUNOFF DIRECTION
I.L.=2.250 IUS PIPE INVERT UPSTREAM (NADD)
IN1-29 IDS PIPE INVERT DOWNSTREAM (NADD)
G.L.=3.460 4.50 PROPOSED ROAD CONTOUR GRADING
I.L.=1.959
CONNECTION TO THE INTERNAL MEP SYSTEM
PROPOSED OIL INTERCEPTOR

OUTFALL STRUCTURE

IDS:1.898
2752250 N

L=30.14
Ø500
IN1-28
G.L.=3.380
I.L.=1.848

IDS:1.700
L=10.87
Ø500
P00 22/09/2023 TENDER STAGE VA AS
CB1-27 REV. Date ISSUED FOR BY CHK
G.L.=3.348

IDS:1.595
I.L.=1.700

L=21.35
Ø500
CLIENT / DEVELOPER :

IMKAN AL JURF PROPERTIES LLC

IN1-26 IMKAN
G.L.=3.282 2 AL Bateen street, Cl Tower, Mezzanine
2752200 N
I.L.=1.595 Floor, Abu Dhabi, United Arab Emirates
Tel: +971 2 652 3888

IDS:1.540
L=28.41
Ø500
Fax:

LEAD CONSULTANT:

OTAK INTERNATIONAL
AL MASAOOD TOWER, 17th Floor, 1701&1702
FATIMA BINT MUBARAK STREET
PO BOX 39192, ABU DHABI, UAE
T +971 2 621 2611
F +971 2 621 4811
www.otakint.com

PROJECT NAME:
QASR AL JURF PHASE 2 - SHA

IDS:1.509
EMIRATES | WELLNESS ISLAND
ZONE: SECTOR: PLOT NO:
QASR AL JURF AL JURF 11
DRAWING TITLE:
2752150 N STORM WATER NETWORK
(SHEET 05 OF 16)

Ø500
13.05
SCALE DRAWING NUMBER SIZE REV.
0 10 20 30 40 50m
1 : 500 @ A1 1:500 IMK-C-163-SW-NW-TS-005 A1 P00

Ø500
IN1-23
GL:3.520
IL:1.470
278050 E

278100 E

278150 E

278200 E

278250 E

278300 E

278350 E

0
IDS 4.30
Ø50

49
:1.4
1
FOR CONTINUATION REFER DRAWING NO: IMK-C-163-SW-NW-TS-007
Copyright reserved C by Otak International