V

ISSUED FOR: JOB NO. 23-55044


FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY:
DRAWN BY:
CMW
SRC
SL-0.0
ISSUED FOR: JOB NO. 23-55044
FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
EXISTING
SCALE: 1/4" = 1'-0"
FOUNDATION PLAN 107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY: CMW
S-0.0
DRAWN BY: SRC
ISSUED FOR: JOB NO. 23-55044
FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
PROPOSED
SCALE: 1/4" = 1'-0"
FOUNDATION PLAN 107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY: CMW
S-0.1
DRAWN BY: SRC
STUD WALL
H2.5A NEW STRINGER
INTERIOR
TO EXISTING JOIST
MARRIAGE WALLS
MATE-LINE
EXSTG 4" BRICK VENEER
EXSTG SUBFLOOR
EXSTG RIM JOIST

EXSTG FLOOR
STRUCTURE
EXSTG FLOOR JOIST,
SEE PLAN EXSTG RIM JOIST
OR BOARD

EXSTG FLOOR
EXSTG SUBFLOOR

STRUCTURE
(2)16X8X8 BLOCK
CROSS STACKED 4-
#5 REBAR CONT. ANGLE W 21"x1" LAG
(ALTERNATE SEAMS) SCREW @ 36" MAX.
FULLY GROUTED & EXSTG FLOOR JOIST,
HORIZONTAL FILLED WITH 8"X8"X16" BLOCK SEE PLAN
GROUT LINES CONCRETE

MIN 2X8 X 16" NEW STRINGERS PA51 INTO


TREATED BLOCK PER PLAN FILLED CELLS
UNDER STRINGERS. (1 PER COLUMN)
PER PLAN- CUT TOP
(2)16x8X8 BLOCK TO ADJUST FOR
COLUMN PER STRINGER HEIGHT IF
GRADEBEAM PER DTL 2 PLAN FULLY 16x16X8
DEEPER THAN 2X8
GROUTED & COLUMN PER
FILLED WITH PLAN
CONCRETE

EXTERIOR COLUMN (BRICK) WALL SECTION


NEW 16X16 COLUMN SECTION 7
1 4 MATE-LINE COLUMN SECTION NTS
NTS NTS

POST EMBED HOLE


SIZE DEPTH DIA.

4X4 2'-6" 12"


H2.5A NEW STRINGER
6X6 3'-6" 20" TO EXISTING JOIST

SLOPE AWAY
EXSTG
FROM POST SUBFLOOR

EXSTG FLOOR
STRUCTURE
GRADE

MIN. 36" EMBED DEPTH 2"


4-#5 REBAR; 2 TOP &
2 BOTTOM w/#3
STIRRUPS @ 12" O.C.

PT POST, SEE PLAN EXSTG FLOOR JOIST,


SEE PLAN
PA51 INTO
NEW FILLED CELLS
EMBED.FOOTING, STRINGERS
FILL SOLID W/ 3000 (1 PER COLUMN)
PER PLAN
PSI CONC

(2)16x8X8
6"

COLUMN PER
PLAN FULLY
GROUTED &
DIAMETER FILLED WITH
CONCRETE

TYPICAL PERIMETER GRADE BEAM FOR 1 STORY 5 PORCH / DECK EMBEDDED POST SECTION INTERIOR COLUMN W/ EX. STRINGERS SECTION
2 8
NTS NTS NTS

INTERIOR STUD
WALL
EXSTG EXTERIOR H2.5A NEW STRINGER
STUD WALL TO EXISTING JOIST
EXSTG FLOOR JOIST,
SEE PLAN EXSTG
EXSTG
GIRDER, SEE
EXSTG SUBFLOOR SUBFLOOR NOTE: IN ALL AREAS WHERE WOOD
PLAN
EXSTG FLOOR
STRUCTURE
EXSTG FLOOR
STRUCTURE

EXSTG RIM JOIST ATTACHES TO CONCRETE, INSTALL MIN


OR BOARD 30# FELT OR OTHER EQUIVALENT
VAPOR RETARDER OR TREATED PLATE/
TREATMENT OF EXISTING PLATE.
P.T. 2X8 EXSTG FLOOR JOIST,
8"X8"X16" BLOCK SEE PLAN
BLOCKING
PA51 INTO
(2)16x8X8 NEW STRINGERS FILLED CELLS
COLUMN PER PER PLAN (1 PER COLUMN)
PLAN FULLY
GROUTED & PER PLAN- CUT TOP
FILLED WITH BLOCK TO ADJUST FOR (2)16x8X8
(1) PA51 CONNECTOR OR STRINGER HEIGHT IF
CONCRETE COLUMN PER
EQUIVALENT COLUMN DEEPER THAN 2X8
TO BLOCKING PLAN FULLY
GROUTED &
FILLED WITH
CONCRETE

EXTERIOR COLUMN WALL SECTION


3 INTERIOR 16X16 COLUMN SECTION 6
NTS NTS

ISSUED FOR: JOB NO. 23-55044


FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY:
DRAWN BY:
CMW
SRC
DT-0.0
ELEVATION ELEVATION
1 2 SCALE: 1/2" = 1'-0"
SCALE: 1/2" = 1'-0"

SECTION SECTION
4A SCALE: 1" = 1'-0"
4B SCALE: 1" = 1'-0"

MAX. ALLOWABLE PILE NOTCH


NOT TO EXCEED 50% OF PILE SECTION
REFER TO STRINGER LAYOUT FOR REFER TO STRINGER LAYOUT FOR
MEMBER SIZES MEMBER SIZES
5/8" DIA. GALV. THROUGH-BOLTS 5/8" DIA. GALV. THROUGH-BOLTS
W/ NUT & OVERSIZED WASHER W/ NUT & OVERSIZED WASHER

6"x6" SQUARE PRESSURE 6"x6" SQUARE PRESSURE


TREATED WOOD COLUMN TREATED WOOD COLUMN

COLUMN TO STRINGER COLUMN TO STRINGER


6A NOT TO SCALE 6P NOT TO SCALE

ISSUED FOR: JOB NO. 23-55044


FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
STRINGER
SCALE: 1/4" = 1'-0"
PLAN 107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY: CMW
S-1.0
DRAWN BY: SRC
JOIST @ 16" O.C.
SEE HANGER SCHEDULE
FOR SIZE

2X BLOCKING BETWEEN 2X JOIST.


BLOCKING SAME SIZE AS JOIST (TYP.)

MIN. 2X8 LEDGER FASTEN WITH GALV. BOLT PER


AM104

TYPICAL LEDGER ATTACHMENT


062 NOT TO SCALE

PILE PER PLAN

A/C PLATFORM CONNECTION


A/C PLATFORM CONNECTION (STEEL ANGLE OPTION)
(PT POST OPTION) SCALE: 1"=1'-0"
SCALE: 1"=1'-0" POST AS PER PLAN

50% MAX. NOTCH ;


POST TO REST ON JOISTS
TYP. (2) 5 8" DIA. GALV. THROUGH-BOLTS
TYP. STAIR LANDING
80 SCALE 1/2"=1'-0"
W/ NUT & OVERSIZED WASHER

STRINGERS (PER PLAN)

2 -5 8" DIA THRU BOLTS


W/ HEAVY WASHERS
AT EACH POST
2X DECK JOISTS
POST BLOCKING DETAIL
060 NOT TO SCALE

ISSUED FOR: JOB NO. 23-55044


FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
DECK JOISTS
SCALE: 1/4" = 1'-0"
FRAMING PLAN 107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY: CMW
S-1.1
DRAWN BY: SRC
ISSUED FOR: JOB NO. 23-55044
FOR PERMITTING MAR. 20, 2024
SHEET NUMBER
- AN ELEVATION - ARAN & FRANKLIN
ENGINEERING, INC.
SITE PLAN
SCALE: 1/16" = 1'-0"
107 HAVEN WAY, WASHINGTON, NORTH CAROLINA REG. NO. C-5046
ENGINEERED BY: CMW
S-6.0
DRAWN BY: SRC