1. Define the Geometry: Begin by defining the geometry of the structural member,
which includes its length, cross-sectional area, moment of inertia, and other
relevant parameters.
3. Determine Critical Load: The critical load, also known as Euler's critical load,
is the load at which buckling occurs. It can be calculated using Euler's formula:
Pcr = (Kl)2π2EI
Where:
Pcr = Critical buckling load
E = Modulus of elasticity
I = Moment of inertia of the cross-section
K = Effective length factor (depends on boundary conditions)
l = Length of the column or member
4. Determine Effective Length Factor: The effective length factor varies based on
the end conditions of the member. Common values include:
- For both ends pinned: K = 1.0
- For one end fixed and one end pinned: K = 0.7
- For both ends fixed: K = 0.5
5. Apply Appropriate Boundary Conditions: Use the correct effective length factor
according to the boundary conditions of your structure.
6. Check for Slenderness Ratio: The slenderness ratio, denoted by λ, is the ratio
of the member's length to its radius of gyration. It is calculated as:
λ = l / r
Ensure that λ falls within the suitable limits for the material and cross-section
shape of the member. For instance, for steel columns, λ should generally be less
than 200 for stability.