Professional Documents
Culture Documents
36
SERIES
FMP
Working pressure
320 bar
A A A A A A
37
Technical data
Filter body (Materials) Filter Element Area
• Head: Cast iron (chemical heat treatment) Filter element in stainless steel mesh
Length
• Housing: Cast iron (chemical heat treatment) Type 1 2 3 4
• Bypass valve: Brass
HP065 374 530 1064 -
• Reverse Flow: Steel (series 135 - 320 only) HP135 950 2020 2700 -
• Check valve: Steel HP320 1650 3645 5970 8280
Values expressed in cm2
Pressure
• Maximum operating pressure: 320bar (32 MPa) Pressure drops Δp Housing
• Test pressure: 420 bar (42 MPa) The curves are plotted using mineral oil
• Burst pressure: 840 bar (84 MPa) with density of 0.86 kg/dm3 to ISO 3968.
• Pulsed pressure fatigue test 1,000,000 cycles Δp varies proportional with density.
with pressure from 0 to 320 bar (32 MPa)
Temperature
• From -25°C to +110°C Filter Housing FMP 065
Length 1 2 3 4
• FMP 065 0.38 0.45 0.67 — 0,50
• FMP 135 0.40 1.02 1.24 —
• FMP 320 1.61 2.61 3.27 4.20 0,00
0 50 100 150 200 250
Connections Flow rate l/min
In-line Inlet/Outlet
Compatibility
• Bodies compatible with: Filter Housing FMP 320
Mineral oils to ISO 2943 - aqueous emulsions
synthetic fluids, water/glycol. Check valve
FMP 065
15
10
Δp bar
0
0 12 24 36 48 60
Flow rate l/min
FMP 135
15
10
Δp bar
0
0 18 36 54 72 90
Flow rate l/min
FMP 320
15
10
Δp bar
0
0 50 100 150 200 250
Flow rate l/min
FMP 320
4,50 1
3,00
Δp bar
2
1,50
0,00
0 70 140 210 280 350
Flow rate l/min
1 - Reverse Flow
2 - In filter direction
39
Dimensions
A A03 23 22
A06 30 23
A10 48 43 1
A16 53 50
H
A25 72 68
M25 105 -
Ø 68 A03 31 30
A06 45 35
A10 60 57
2
A16 64 63
A25 82 77
M25 106 -
A03 53 52
100
A06 61 58
A10 79 78 3
A16 84 83
A25 94 93
M25 108 -
A E
Threaded Connections Depth 15 mm
Side B
Standard position for G 1/2” M8
bypass valve
1/2” NPT 5/16“ UNC
Ch. 30
G 3/4” M8
3/4” NPT 5/16“ UNC
E 2 fixing holes
SAE 8 (3/4”- 16 UNF) 5/16” UNC
SAE 12 (1 1/16”- 12 UN) 5/16“ UNC
106
46
Filter H
Length mm
1 169
Side C 2 200
Alternative position for
bypass valve 3 302
Ch. 30 12
40
FMP 135
38
type Series N Series H
A03 69 50
A
A
A06 74 57
A10 120 98 1
A16 129 101
A25 171 156
M25 200 -
A03 110 91
H
A E
Threaded Connections Depth 15 mm
60
A B
40,6 Flanged Connections Depth 15 mm
Filter H
Length mm
1 220
2 333
3 408
41
FMP 320
40
Ch. 3
A
A
Indicator connection
Plug T2 - Ch. 30
Ch. 3
Ø 128
P01 150 mm
H
Ø 105
Ch. 30
P02 550 mm
Oil drain plug
G 3/8” - Ch. 8
Ch. 30
Side B Side C
Bypass valve standard Bypass valve alternative
position position
94
E nr. 4 fixing Plug T2 Ch. 30
Ch. 46 holes
Bypass valve Indicator position
57
Plug T2
Ch. 30 Ch. 46
Indicator position Bypass valve
42
FMP 320
43
Spare par ts FMP
4 1 6
5f 5g
5e 5d
2
5a
5b
5c
5h 5m
44
Ordering information FMP
Filter assembly 1 2 3 4 5 6 7 8a
FMP
Example: FMP 065 2 B A G1 A03 N P01
Filter element 1 2 6 4 7 8b
HP
Example: HP 065 2 A03 A N P01
1 - Size 6 - Filter elements
065 A03 Inorganic microfibre 3 µ
5 - Connections
Type 065 135 320
MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and
replacement parts. All rights reserved
The data in this publication is marketing information. MP Filtri reserves the right to make changes to the product described herein at any time it deems fit in relation to technical or
commercial requirements. The colors of the products shown on the cover are for illustration purposes only.
Copyright. All rights reserved.
45