You are on page 1of 27

B/S/H/ Fault Codes and Service Programs PW

BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

1 FAULT-CODES AND APPLIANCE MESSAGES 1 4 VARIANT CODING 18


1.1 Fault-Codes (ordered) 2 4.1 Variant coding PU 18 Explanation:
Error 7 – 18 2 Activate PU variant coding mode 18 S/P S/P
Key w/o LED......................................
Error 19 – 31 3 Select variant used by PU 18-19 S/P S/P
Error 34 – 49 4 Leave PU variant coding mode 19 Key with LED.....................................
Error 50 – 67
15 0 1
5 1 Setting machine device class 19 14
13
2
3
pos. 9 12
11
4
5
Error 71 - 82 6 2 Setting speed variant 20 10 6

Program selector............................... 9 8 7

2 SERVICE-PROGRAMS 7 3 Setting Aqua stop / warm water variant 20


2.1 Customer service test program 7 4 Setting water valve variant 21
S/P
Activate test mode 7 5 Setting door lock variant 21 LED Start / Pause illuminate..............
Select test program 7-8 6 Setting flow senser variant 21 S/P
LED Start / Pause is flashing.............
Start/Restart test program 8 7 Setting turbidity sensor variant 22 S/P
Abort test program 8 8 Setting 3D sensor variant 22 LED Start / Pause is off.....................
Leave test mode 8 9 Setting foam wash sensor variant 22
2.2 Stored error codes / Error search 9 10 Setting dosage system 22
Press key...........................................
" S/P

Activate error search mode 9 11 Setting VT set 22


Display of 1st error 9-10 4.2 Variant coding OU 23 Turn program selector to pos.9 15
14
13
0 1
2
3

Display of 1st – 5th error 10 Activate OU variant coding mode 23 while key is pressed.........................
* O + pos. 9 12
11
10
4
5
6
9 8 7

Leave error search mode 10 Select variant used by OU 23-24 ! O


Leave key..........................................
Leave PU variant coding mode 24
3 FUNCTIONS OF SERVICE-PROGRAMS 10 1 Setting acoustic feedback 24
3.1 Customer service test program 10 2 Setting brand 24
1 Automatic test 10-11 3 Setting child proof 24
2 Fans test 12 4 Setting load display 24
3 Motor 13 5 Setting panel colour 25
4 Valves 14 6 Setting sales area 25
5 Pump 14 7 Setting overdosage 25
6 Heater 15 8 Setting key variant 25
7 Pressure sensor adjustment 15 9 Setting menu variant 26
9 Flow rate sensor 16
12 Heater (dryer) 17
13 Display 17
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 1 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

1 FAULT CODES AND APPLIANCE MESSAGES


Display Description Possible Cause Check / Remedial action / Remark
F.No Normal- Test mode Possible effect
1.1 Fault codes (in ascending order)
FATAL ERROR sequence: a) washing or drying program aborted d) display is frozen
b) door is locked possibly e) pump is activated possibly
c) operator control actions are blocked
7 E:07 Condensor outlet NTC error - Condenser outlet NTC broken or short circuit - check condenser outlet NTC
- FATAL ERROR (a, b, c, d) - and drying unit wire harness
8 E:08 Condensor inlet NTC error - Condenser inlet NTC broken or short circuit - check condenser inlet NTC
- FATAL ERROR (a, b, c, d) - and drying unit wire harness
9 E:09 E:09 Drying tunnel outlet NTC error - Drying tunnel outlet NTC broken or short circuit - check drying tunnel outlet NTC
- FATAL ERROR (a, b, c, d) - and drying unit wire harness
16 E:16 Door lock is not closed - door is open - close door
- washing program is halted - door switch is not actuated - check door lock, check wire harness
- a restart is possible Normal mode: start any washing program
- error will not be stored with an open door
17 E:17 Water filling time exceeded - water tap is closed - open water tap
(conventional measurement) - water pressure <1bar at supply - check components, wire harness
- washing program is halted - filter or supply is blocked Pos. 7 Water level (Pressure sensor)
- pump starts after 5 min - solenoid valve / aqua stop valve is broken Pos. 4 Valves
- a restart is possible - pressure sensor is broken
18 E:18 E:18 Pumping time exceeded - pump is blocked or broken - switch ON/OFF for reset
- FATAL ERROR (a, b, c, d) - pressure sensor is broken - check components, wire harness
- hose to the pressure sensor is blocked Pos. 5 Pump
- draining hose is blocked

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 2 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Display Description Possible Cause Check / Remedial action / Remark


F.No Normal- Test mode Possible effect
FATAL / REMANENT a) washing or drying program aborted d) display is frozen Reset REMANENT ERROR: "Safe state flag"
ERROR sequence: b) door is locked possibly e) pump is activated possibly must be set
c) operator control actions are blocked
19 E:19 heating time exceeded - heating circuit is broken - check heater
- washing program will be finished - set temperature can not be achieved - check wire harness
without heating - low voltage - check control
- fossil heater or heater is broken Pos. 6 Heater
- heater relay is blocked
20 E:20 unexpected heating - NTC is broken (out of range) - reset remanent error (see instruction above)
- REMANENT ERROR (a, b, c, d, e) - heater relay is stuck - check NTC, heater, replace power module
- the heater is actuated in a non heating period Pos. 6 Heater
23 E:23 E:23 aqua stop actuated - water in the base tub - check leak tightness of water system
- washing program is aborted - leaky water system - check aqua stop switch, wire harness
- the pump is actuated - aqua stop switch is blocked / broken Normal mode
26 E:26 error of analogue pressure sensor - pressure sensor broken - switch ON/OFF for reset
(provides error voltage) - hose to the pressure sensor is blocked - check pressure sensor, wire harness
- FATAL ERROR (a, b, c, d, e) Pos. 7 Water level (Pressure sensor)
28 E:28 error of flow sensor - flow sensor is broken - check flow sensor
(provides implausible values) - check wire harness
- The water intake is changed from Pos. 7 Water level (Pressure sensor)
volume based to time based
29 E:29 no water filling detected by flow sensor - water tap is closed - open water tap
(fast measurement) - water pressure <1bar at supply - check components, wire harness
- washing program is halted - filter is blocked / supply is blocked Pos. 7 Water level (Pressure sensor)
- a restart is possible - valves or pressure sensor broken Pos. 4 Valves
31 E:31 overflow level exceeded - pump, draining hose is blocked, valve is stuck - check components, wire harness
- pump is activated until water level < - adjustment of pressure sensor is incorrect Pos. 7 Water level (Pressure sensor)
overflow level (at least 3 min) └ pressure sensor is blocked Pos. 4 Valves
- the program is continued └ hose to the pressure sensor is blocked Pos. 5 Pump

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 3 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Display Description Possible Cause Check / Remedial action / Remark


F.No Normal- Test mode Possible effect
FATAL / REMANENT a) washing or drying program aborted d) display is frozen
ERROR sequence: b) door is locked possibly e) pump is activated possibly
c) operator control actions are blocked
34 E:34 Door lock can not be locked - door lock is broken - switch ON/OFF for reset
- washing program is aborted - door, or door hook is stuck - check door lock
- door is unlocked possibly - stiff gasket - check mechanic
- operator control actions are blocked - check wire harness
35 E:35 Door lock can not be unlocked - door lock broken, stucked - switch ON/OFF for reset
- FATAL ERROR (b, c, d) - Window clamp - check door lock, mechanism, and wire
- gasket to inflexible harness
37 E:37 Error of temperature sensor: break - NTC is broken - check NTC, and wire harness
- washing program will be finished without heating Pos. 6 Heater
38 E:38 Error of temperature sensor: short-circuit - NTC is short-circuit - check NTC, and wire harness
- washing program will be finished without heating Pos. 6 Heater
40 E:40 Error of mains frequency synchronisation - weak power supply - Check power supply
- washing program is aborted Normal mode
43 E:43 Locked rotor (for normal mode only in - drum is blocked by laundry - switch ON/OFF for reset without laundry
error stack and Last Error) - motor is blocked - check load, check motor
- washing program is finished with limited motor running Pos. 3 Motor
47 E:47 Heat sink temp. sensor broken or short circuit (for - heat sink NTC of motor module is broken, - switch ON/OFF for reset
normal mode only in error stack and Last Error) - or short circuit - check, or replace motor module
- FATAL ERROR (a) Pos. 3 Motor
48 E:48 Line undervoltage (for normal mode only in error - line voltage < 150V - switch ON/OFF for reset
stack and Last Error - check power supply
- washing program is finished without motor running Pos. 3 Motor
49 E:49 Line overvoltage (for normal mode only in error - line voltage > 150V - switch ON/OFF for reset
stack and Last Error - check power supply
- washing program is finished without motor running Pos. 3 Motor

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 4 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Display Description Possible Cause Check / Remedial action / Remark


F.No Normal- Test mode Possible effect
FATAL / REMANENT a) washing or drying program aborted d) display is frozen
ERROR sequence: b) door is locked possibly e) pump is activated possibly
c) operator control actions are blocked
50 E:50 DC motor overcurrent (for normal mode only in - motor current is above the hardware
- switch ON/OFF for reset without laundry
error stack and Last Error protection limit
- check load, check or replace motor module
- washing program is finished with limited motor running Pos. 3 Motor
51 E:51 IGBT short circuit - IGBT of motor module is short circuit - switch ON/OFF for reset
- FATAL ERROR (a) - wire(s) between motor and MU short circuit - check wire harness between motor and MU
- check or replace motor module
Pos. 3 Motor
52 E:52 IGBT broken - IGBT of motor module is broken - switch ON/OFF for reset
- FATAL ERROR (a) - wire(s) between motor and MU short broken - check wire harness between motor and MU
- check or replace motor or motor module
Pos. 3 Motor
57 E:57 PU-MU communication (for normal mode only in - mains or D-Bus wires are not connected - switch ON/OFF for reset
error stack and Last Error) between PU and MU - check wire harness between PU and MU
- remaining time in program is freezed w/o error display Pos. 3 Motor
59 E:59 3D/3G-Sensor: measurement or plausibility error - wire harness, cotrol, or 3D/3G-Sensor broken - check wire harness, 3D/3G-Sensor, control, and
- reduced spin speed - EMC failure, or magnet not in position magnet position
- software of sensor incompatible Pos. 3 Motor
61 E:61 Implausible door lock status - door is locked but open - switch ON/OFF for reset
- FATAL ERROR (a, b, c, d, e) - emergency unlock was actuated by hand - check door lock, mechanic, and wire harness
Normal mode
63 E:63 System error - no communication between PU and OU - check D-Bus wire harness
- FATAL ERROR (a, b, c, d) - no communication between PU and MU - replace power- or dryer module
67 E:67 E:67 Implausible or inexistent variant coding - incorrect or inconsistent variant coding - switch ON/OFF for reset
- FATAL ERROR (a, b, c, d, e) on PU/OU - reapeat variant coding, or replace control(s)
- software of control is incompatible - reprogram the control(s) (development only)
Variant coding

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 5 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Display Description Possible Cause Check / Remedial action / Remark


F.No Normal- Test mode Possible effect
FATAL / REMANENT a) washing or drying program aborted d) display is frozen
ERROR sequence: b) door is locked possibly e) pump is activated possibly
c) operator control actions are blocked
71 E:71 BLDC precharge relay (for normal mode only in - precharge relay of MU is broken or - switch ON/OFF for reset
error stack and Last Error) short circuit - check and replace MU
- FATAL ERROR (a) Pos. 3 Motor
72 E:72 BLDC asymmetry (for normal mode only in - motor windings are asymmetricaly - switch ON/OFF for reset
error stack and Last Error) - check and replace motor
- FATAL ERROR (a) - check wire harness between PU and MU
Pos. 3 Motor
73 E:73 PU-DU communication - wrong PU-DU communication - replace control(s)
- FATAL ERROR (c, d) - reprogram the control(s) (development only)
75 E:75 BLDC max torque (for normal mode only in - drum is blocked or limited by laundry - switch ON/OFF for reset without laundry
error stack and Last Error) - motor is blocked abruptly while running Pos. 3 Motor
- washing program is finished with limited motor running
77 E:77 BLDC line frequency (for normal mode only in error - line frequency is < 35Hz or > 75Hz - switch ON/OFF for reset
stack and Last Error) - check power supply
- FATAL ERROR (a) Pos. 3 Motor
78 E:78 BLDC hardware (for normal mode only in error - hardware error on motor module (MU) - switch ON/OFF for reset
stack and Last Error) - check / replace motor module
- FATAL ERROR (a) Pos. 3 Motor

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 6 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Display Description Possible Cause Check / Remedial action / Remark


F.No Normal- Test mode Possible effect
FATAL / REMANENT a) washing or drying program aborted d) display is frozen
ERROR sequence: b) door is locked possibly e) pump is activated possibly
c) operator control actions are blocked
21 E21 failure in drive circuit - Triac short-circuit - check the PU
unregulated motor run-up - speed sensor is broken - check the wireharness
drum motor does not rotate - hardware failure - check the motor
- FATAL + REMANENT ERROR - Special for UMAC motor
- washing program is aborted

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 7 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

2 SERVICE PROGRAMS
Function Actuation Display Remark

2.1 Customer Service Test Program


Activate test mode: Close door
h 15 0 1

Switch off appliance 14


13
2
3 - Appliance was switched off for at least 5s
pos. 0 12
11
10
4
5
6
9 8 7
15 0 1

Set program selector to 14 2


- The following operational sequence must be performed within 15s
S/P
13 3
pos. 8 12
11
10
4
5
6
9 8 7
0

- Set the program selector to pos. 9, while the „temperature“ key


15 1

Press key
*
14 2

O S/P
13 3

+ pos. 9 12
11
4
5
10
9 8
6
7
is actuated Start/Pause is flashing
Release key - Release the „temperature“ key
! O S/P P:09 is displayed
Last occured error code will be displayed for about 5sec, otherwise
S/P nothing will be displayed. See Error search
15 0 1

Select test program: Set program selector - Select the test program by setting program selector
Q
14 2

S/P
13 3
pos. 1 12
11
10
4
5
6
9 8 7
0

Pos. 1 – Automatic test


15 1

Set program selector to 14 2

S/P
13 3
pos. 1 12
11
10
4
5
6
9 8 7
0

Pos. 2 – Fans (dryer)


15 1

Set program selector to 14 2

S/P
13 3
pos. 2 12
11
10
4
5
6
9 8 7
0

Pos. 3 – Motor (reversing and spinning)


15 1

Set program selector to 14 2

1400 S/P
13 3
pos. 3 12
11
4
5
10
9 8
6
7
Max. spin speed is displayed
0

Pos. 4 – Valves
15 1

Set program selector to 14 2

S/P
13 3
pos. 4 12
11
10
4
5
6
9 8 7
0

Pos. 5 – Pump
15 1

Set program selector to 14 2

S/P
13 3
pos. 5 12
11
10
4
5
6
9 8 7
0

Pos. 6 – Heater (washer)


15 1

Set program selector to 14 2

S/P
13 3
pos. 6 12
11
10
4
5
6
9 8 7

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 8 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


0

Pos. 7 – Pressure sensor adjustment


15 1

Set program selector to 14 2

S/P
13 3
pos. 7 12
11
10
4
5
6
9 8 7
0

Pos. 8 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 8 12
11
10
4
5
6
9 8 7
0

Pos. 9 – Flow sensor


15 1

Set program selector to 14 2

S/P
13 3
pos. 9 12
11
10
4
5
6
9 8 7
0

Pos. 10 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 10 12
11
10
4
5
6
9 8 7
0

Pos. 11 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 11 12
11
10
4
5
6
9 8 7
0

Pos. 12 – Heater dryer (2 stage)


15 1

Set program selector to 14 2

S/P
13 3
pos. 12 12
11
10
4
5
6
9 8 7
0

Pos. 13 – Buttons and optical indicator elements


15 1

Set program selector to 14 2

S/P
13 3
pos. 13 12
11
10
4
5
6
9 8 7
0

Pos. 14 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 14 12
11
10
4
5
6
9 8 7
0

Pos. 15 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 15 12
11
10
4
5
6
9 8 7

Start or Press key - Press Start/Pause 2 times to restart a program from the beginning
restart test program: " S/P S/P Start/Pause is illuminating
15 0 1

Abort test program: Press key or 14 2


- Door stays locked if a security relevant instance is detected
" S/P Q h S/P
13 3

/ pos. 1 12
11
4
5
10
9 8
6
7 (to high water level, -spin speed, or -temperature)
Door icon and, or Start/Pause is flashing
15 0 1

Leave test mode: Set program selector to 14


13
2
3 - The test mode is left also after a mains power blackout
pos. 0 12
11
10
4
5
6
9 8 7

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 9 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

2.2 Stored error-codes / error search


Activate error search Close door - Error search mode activation is possible, even if the appliance is
h 15 0 1
in FATAL ERROR state
Switch off appliance 14
13
2
3
pos. 0 12
11
10
4
5
6
9 8 7
15 0 1

Set program selector to 14 2


- Wait until Start/Pause is flashing
S/P
13 3
pos. 4 12
11
4
5
10
9 8
6
7
Start/Pause is flashing
0

- Set the program selector to pos. 5, while the „temperature“ key


15 1

Press key
*
14 2

O S/P
13 3

+ pos. 5 12
11
4
5
10
9 8
6
7
is actuated
Release key
! O S/P Start/Pause is switched off
15 0 1

Display of 1st error per Set program selector - Select the monitoring period by setting program selector
Q
14 2

S/P
13 3
pos. 1 12
11
4
5
monitoring period: 10
9 8
6
7
First error: / No error: First error, or E:00 is shown
0

Pos. 1 – First error of the last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 1 12
11
10
4
5
6
/
9 8 7
0

Pos. 2 – First error of the 2nd last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 2 12
11
10
4
5
6
/
9 8 7
0

Pos. 3 – First error of the 3rd last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 3 12
11
10
4
5
6
/
9 8 7
0

Pos. 4 – First error of the 4th last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 4 12
11
10
4
5
6
/
9 8 7
0

Pos. 5 – First error of the 5th last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 5 12
11
10
4
5
6
/
9 8 7
0

Pos. 6 – First error of the 6th last monitoring period


15 1

Set program selector to 14 2

S/P
13 3
pos. 6 12
11
10
4
5
6
/
9 8 7

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 10 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Set program selector to Pos. 7 – First error of the 7th last monitoring period

Set program selector to Pos. 8 – First error of the 8th last monitoring period

Set program selector to No display Pos. 9-15 – Not implemented

Display of errors: Press key - Switch through next occured error(s) for the selected monitoring period
0 error: Next error(s), or E:00 is shown
Press key - If at least one error is stored for the selected monitoring period,
1st error: then the 1st error stored within this monitoring period is displayed
Press key Otherwise E:00 is displayed
2nd error:

and so on
Leave error display Set program selector to - The error display mode is left also after a mains power blackout
mode:

3 FUNCTIONS OF SERVICE PROGRAMS


Function Actuation Display Remark
Time(s) Value Inspection / Corrective Note
3.1 Customer Service Test Program
Pos. 1 Automatic test
Press key - Start program
Start/Pause is flashing
Door is locked
Start/Pause is illuminating
Quick test of all - The sequence is shown on the
components next page

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 11 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

P r e f ill S p in n in g
appr. 25s u p t o m a x . s p in s p e e d

V a lv e 1 - p r e w a s h

V a lv e 2 - m a in w a s h ( c o ld )

V a lv e 3 - m a in w a s h
(w arm)
V a lv e 4 - f lu s h in g

V a lv e - A q u a S t o p

H e a te r

D r y in g h e a t e r - S t a g e 1
( lo w )
D r y in g h e a t e r - S t a g e 2
( h ig h )
Fa n 1 - p ro c e s s

F a n 2 - c o o lin g

Pu m p

M o to r

...1 0 0
5 2 ...

102
10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

44

46

48

50
-6

-4

-2

c lo c k w is e 5 0 r p m a n t ic lo c k w is e 5 0 r p m T im e in s
( d r u m a n t ic lo c k w is e ) ( d r u m c lo c k w is e )

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 12 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 2 Fans (dryer)


Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Activation of process 5
air fan h S/P
Pause 2
h S/P
Activation of cooling 5
air fan h S/P
Pause 2
h S/P
Activation of process 5
and cooling air fan h S/P
Door is unlocked
S/P Start/Pause is flashing

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 13 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 3 Motor
Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Pump is activated
h S/P
Drum is rotated 50rpm
anticlockwise h S/P
Pause 2
h S/P
Drum is rotated 50rpm
clockwise h S/P
Spin speed is increased
to max. spin speed h S/P
Spinning at maximum appr. max.
spin speed B h S/P 4min rpm
Pump is switched off
h S/P
Door is unlocked
1400 S/P Start/Pause is flashing

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 14 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 4 Valves
Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Pump is activated until the
appliance is completely drained h S/P
Water inlet via V1 - 7
pre wash h S/P
Water inlet via V2 - 10
main wash h S/P
Water inlet via V4 - 10
flushing h S/P
Water inlet via V1 & ½ - Water inlet until water level
V2 – pre- & main wash h S/P drum-ø has reached half of drum volume
- Door remains locked
h S/P Start/Pause is flashing

Pos. 5 Pump
Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Pump is activated until the
appliance is completely drained h S/P
Door is unlocked
S/P Start/Pause is flashing

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 15 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 6 Heater
Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Water inlet until heater-
on level is reached h S/P
Heater is activated 85°C
h S/P
- Door remains locked
h S/P Start/Pause is flashing

Pos. 7 Pressure sensor adjustment


Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Pump is activated until the
appliance is completely drained h S/P
Pressure sensor
adjustment starts h S/P
Pressure sensor
adjustment ends h S/P
Water inlet via V1 - appr. (measured from drum body - Water inlet until target level
pre wash h S/P 2-4cm up to the water surface) for measuring is reached
Door is unlocked Start/Pause is flashing
S/P

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 16 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 9 Flow rate sensor


Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Flow measurement
starts h S/P
Water quantity
measurement starts h S/P
Pump is activated until the
appliance is completly drained h S/P
Water inlet via V1 - 5l
pre wash h S/P
Water quantity
measurement ends h S/P
Flow measurement
ends h S/P
- Door remains locked
h S/P Start/Pause is flashing
or error E:29 is displayed

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 17 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


Time(s) Value Inspection / Corrective Note

Pos. 12 Heater dryer


Press key - Start program
" S/P S/P Start/Pause is flashing
Door is locked
h S/P Start/Pause is illuminating
Process- and cooling fan
are activated h S/P
Drying heater - stage 1 5
(low segment) is activated h S/P
Drying heater - stage 2 5
(high segment) is activated h S/P Not for Chinese variant
Drying heater - stage 1
(low segment) is switched off h S/P
Pause 5
h S/P
Drying heater - stage 2
(high segment) is switched off h S/P
Process- and cooling fan
are switched off h S/P
Door is unlocked Start/Pause is flashing
S/P

Pos. 13 Display
Press key - Start program
" S/P S/P Start/Pause is flashing
All display segments are All display segments
activated
S/P Start/Pause is illuminating
Press key - Press Start/Pause to
" S/P S/P abort the program Start/Pause is flashing
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 18 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

4 VARIANT CODING
Function Actuation Display Remark

4.1 Variant Coding PU ! The variant code is printed at the rating plate at the back of the appliance and at the door label
Activate PU variant coding Close door
mode: h 15 0 1

Switch off appliance 14


13
2
3 - Appliance was switched off for at least 5s
pos. 0 12
11
10
4
5
6
9 8 7
15 0 1

Set program selector to 14 2

S/P
13 3
pos. 12 12
11
4
5
10
9 8
6
7
Start/Pause is flashing
0

- Set the program selector to pos. 9, while the „temperature“


15 1

Press key
*
14 2

O S/P
13 3

+ pos. 11 12
11
10
4
5
6
key is actuated
9 8 7

Release key - Release the „temperature“ key


! O S/P Start/Pause is illuminating
15 0 1

Select variant used by PU: Set program selector - Select the variant by setting program selector
Q
14 2

S/P
13 3
pos. 1 12
11
10
4
5
6
9 8 7
0

Pos. 1 – Machine device class


15 1

Set program selector to 14 2

S/P
13 3
pos. 1 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 2 – Speed variant


15 1

Set program selector to 14 2

S/P
13 3
pos. 2 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 3 – Aqua stop / Warm water


15 1

Set program selector to 14 2

S/P
13 3
pos. 3 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 4 – Water valve variant


15 1

Set program selector to 14 2

S/P
13 3
pos. 4 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 5 – Door lock variant


15 1

Set program selector to 14 2

S/P
13 3
pos. 5 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 6 – Flow sensor


15 1

Set program selector to 14 2

S/P
13 3
pos. 6 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 7 – Turbidity sensor (not used yet)


15 1

Set program selector to 14 2

S/P
13 3
pos. 7 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 19 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


0

Pos. 8 – 3D sensor (not used yet)


15 1

Set program selector to 14 2

S/P
13 3
pos. 8 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 9 – Foam wash sensor (not used yet)


15 1

Set program selector to 14 2

S/P
13 3
pos. 9 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 10 – Dosage system (not used yet)


15 1

Set program selector to 14 2

S/P
13 3
pos. 10 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 11 – VT-Set (not used yet)


15 1

Set program selector to 14 2

S/P
13 3
pos. 11 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 12-15 – Not implemented


15 1

Set program selector to 14 2

S/P
13 3
pos. 12-15 12
11
10
4
5
6
9 8 7
15 0 1

Leave PU variant Set program selector to 14


13
2
3
pos. 0 12
11
4
5
coding mode: 10
9 8
6
7

Pos. 1 Setting machine device class


range 0...2
Variant 0: Press key - Press any key (except Start/Pause) to change variant
F21 " " S/P S/P code value
Variant 1: Press key - Press any key (except Start/Pause) to change variant
S21 " " S/P S/P code value
Variant 2: Press key - Press any key (except Start/Pause) to change variant
D21 " " S/P S/P code value

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 20 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Pos. 2 Setting speed variant


range 0...7
Variant 0: Press key - Press any key (except Start/Pause) to
1480rpm " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 2: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 3: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 4: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 5: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 6: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Variant 7: Press key - Press any key (except Start/Pause) to
1200rpm " " S/P S/P change variant code value
Pos. 3 Setting Aqua stop / Warm water variant
range 0...3
Variant 0: Press key - Press any key (except Start/Pause) to
without Aqua stop " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
with Aqua stop, cold water " " S/P S/P change variant code value
Variant 2: Press key - Press any key (except Start/Pause) to
with Aqua stop, warm water " " S/P S/P change variant code value
Variant 3: Press key - Press any key (except Start/Pause) to
with Aqua stop, cold & warm water " " S/P S/P change variant code value

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 21 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Pos. 4 Setting water valve variant


range 0...3
Variant 0: Press key - Press any key (except Start/Pause) to
Double valve cold " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Triple valve (double cold & flush) " " S/P S/P change variant code value
Variant 2: Press key - Press any key (except Start/Pause) to
Triple valve (double cold & warm) " " S/P S/P change variant code value
Variant 3: Press key - Press any key (except Start/Pause) to
Double valve (cold & warm) " " S/P S/P change variant code value
Pos. 5 Setting door lock variant
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Magnetic door lock " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
PTC door lock " " S/P S/P change variant code value
Pos. 6 Setting flow sensor variant
range 0...3
Variant 0: Press key - Press any key (except Start/Pause) to
Without flow sensor " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
With flow sensor, cold water " " S/P S/P change variant code value
Variant 2: Press key - Press any key (except Start/Pause) to
With flow sensor, warm water " " S/P S/P
change variant code value
Variant 3: Press key - Press any key (except Start/Pause) to
With flow sensor, cold & warm water " " S/P S/P change variant code value

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 22 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Pos. 7 Setting turbidity sensor variant – not used yet


range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Without turbidity sensor " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
With turbidity sensor " " S/P S/P change variant code value
Pos. 8 Setting 3D sensor variant – not used yet
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
3D Marquard " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
3D Seuffer " " S/P S/P change variant code value
Pos. 9 Setting foam wash sensor variant – not used yet
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Without foam wash sensor " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
With foam wash sensor " " S/P S/P change variant code value
Pos. 10 Setting dosage system – not used yet
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Without dosage system " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
With dosage system " " S/P S/P change variant code value
Pos. 11 Setting VT set – not used yet
range 0...1

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 23 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

4.2 OU variant coding ! The variant code is printed at the rating plate at the back of the appliance and at the door label
Activate OU variant coding Close door
mode: h 15 0 1

Switch off appliance 14


13
2
3 - Appliance was switched off for at least 5s
pos. 0 12
11
10
4
5
6
9 8 7
15 0 1

Set program selector to 14 2

S/P
13 3
pos. 11 12
11
4
5
10
9 8
6
7
Start/Pause is flashing
0

- Set the program selector to pos. 9, while the „temperature“


15 1

Press key
*
14 2

O S/P
13 3

+ pos. 10 12
11
10
4
5
6
key is actuated
9 8 7

Release key - Release the „temperature“ key


! O S/P Start/Pause is illuminating
15 0 1
Select variant used by OU: Set program selector - Select the variant by setting program selector
Q
14 2

S/P
13 3
pos. 1 12
11
10
4
5
6
9 8 7

Pos. 1 – Acoustic feedback


15 0 1
Set program selector to 14 2

S/P
13 3
pos. 1 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 2 – Brand
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 2 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 3 – Child proof
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 3 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 4 – Load display
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 4 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 5 – Panel colour (not used yet)
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 5 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 6 – Sales area
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 6 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
Pos. 7 – Overdosage
15 0 1
Set program selector to 14 2

S/P
13 3
pos. 7 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 8 – Key variant


15 1

Set program selector to 14 2

S/P
13 3
pos. 8 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 24 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark


0

Pos. 9 – Menu variant


15 1
Set program selector to 14 2

S/P
13 3
pos. 9 12
11
4
5
10
9 8
6
7
Actual variant code value is displayed
0

Pos. 10-15 – Not implemented


15 1
Set program selector to 14 2

S/P
13 3
pos. 10-15 12
11
10
4
5
6
9 8 7
15 0 1
Leave OU variant Set program selector to 14
13
2
3
pos. 0 12
11
4
5
coding mode: 10
9 8
6
7

Pos. 1 Setting acoustic feedback - not used yet


range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Buzzer " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Speaker " " S/P S/P change variant code value
Pos. 2 Setting brand
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Siemens " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Bosch, Neff " " S/P S/P change variant code value
Pos. 3 Setting child proof
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
With child proof " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Without child proof " " S/P S/P change variant code value
Pos. 4 Setting load display
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
With load display " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Without load display " " S/P S/P change variant code value
BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 25 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Pos. 5 Setting panel colour – not used yet


range 0...3
Variant 0: Press key - Press any key (except Start/Pause) to
White " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Silver " " S/P S/P change variant code value
Variant 2: Press key - Press any key (except Start/Pause) to
Golden/Silver " " S/P S/P change variant code value
Variant 3: Press key - Press any key (except Start/Pause) to
Stainless steel " " S/P S/P change variant code value
Pos. 6 Setting sales area
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
China " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
Export " " S/P S/P change variant code value
Pos. 7 Setting overdosage
range 0...1
Variant 0: Press key - Press any key (except Start/Pause) to
Without overdosage display " " S/P S/P change variant code value
Variant 1: Press key - Press any key (except Start/Pause) to
With overdosage display " " S/P S/P change variant code value
Pos. 8 Setting key variant
range 0...7
Variant 0: Press key - Press any key (except Start/Pause) to
Key variant " " S/P S/P change variant code value
Variant 1-7: Press key - Press any key (except Start/Pause) to
Not used " " S/P S/P change variant code value

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 26 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.
B/S/H/ Fault Codes and Service Programs PW
BO - Bosch CT 0
SE - Siemens 0 PQK B T s K
O AutoDry min
T 14
15 1
2 14
15 1
2
Stains

PQK B T , kg h G 13 3 13 3
Gh . kg O1 O2 O3
S/P
W Stains
Option 12 4 S/P 12 4
auto
11 5 11 5
C T+ min
10 6 10 6
B O1 O2 O3 Select 9
8
7 9
8
7
O B W Option Select T

Function Actuation Display Remark

Pos. 9 Setting menu variant


range 0...7
Variant 0: Press key - Press any key (except Start/Pause) to
Menu variant " " S/P S/P change variant code value
Variant 1-7: Press key - Press any key (except Start/Pause) to
Not used " " S/P S/P change variant code value

BSH BOSCH UND SIEMENS HAUSGERAETE GMBH Document-No.: 55340000033034 ASP english Page-No.:
Revision: A
Test Program/Coding Instruction D21-Relaunch Material-No.: 9000903603 27 of 27
The reproduction, transmission or use of this document or its contests is not permitted without express written authority. Offenders will be liable for damages. All rights including rights created by patent grant or registration of a utility model or design are reserved. Copyright reserved.

You might also like