You are on page 1of 1

For One Footing Total (4 Footings) Total Weight

Pose No Diameter Detailed Dimensions a (mm) b (mm) Length (mm) Number Weight (kg) Number Weight (kg) (kg)

1 Ø16 150 2000 2300 8 x 2 58 64 232

2 Ø16 150 2000 2300 8 x 2 58 64 232

3 Ø10 150 300 1200 3 2 12 9


L
L1
4 Ø16 260 2500 2760 16 70 64 279
882

5 Ø10 400 50 1700 18 19 72 75


S

6 Ø10 283 50 1231 18 14 72 55

L
Excavation Reinforced Lean Concrete Reinforcement
L2 FOUNDATION BOTTOM REINFORCEMENT
S (m) L (m) b (m) tf (m) ts (m) tos (m) tpp (m) L1 (m) L2 (m)
(m3) Concrete (m3) (m3) (kg)
3.21 2.15 0.55 0.30 2.10 0.25 0.10 5.36 1.06 55.2 8.4 2.2 882
L1
S L2

SECTION A-A FOUNDATION PLAN


L
ANCHORAGE DETAIL
FOUNDATION TOP REINFORCEMENT

S
tos

NOTES
ts b 1) Concrete clear cover will be taken as 75mm.
2) L1 and L2 are given according to the reinforced concrete, not plain
concrete.
tpp 3) The allowable bearing capacity of the soil is 200kPa.
4) Material : Concrete = C25
tpp Reinforcement = S420

tf

Eski Guvercinlik Yolu 113 Gazi 06560


Ankara TURKEY Tel : +90 312 296 20
00 Fax : +90 312 296 29 99
L info@mitastelecom.com

REINFORCEMENT PLAN FOUNDATION CROSS SECTION Client : KOREK


Project : 0
Tower Code : 30-VKL-160-10-G
Prepared By : B.TUNC
Date : 7.7.2017