M U LT I - P O RT S I N G L E – P H A S E
WARNING: Exhaust fumes contain carbon monoxide, an odorless, colorless, and POISONOUS gas that can cause
unconsciousness and death. Symptoms of carbon monoxide exposure can include:
■ Dizziness
■ Nausea
■ Headache
■ Weakness
■ Sleepiness
■ Throbbing in Temples
■ Muscular Twitching
■ Vomiting
■ Impaired Judgement
IF YOU OR ANYONE ELSE EXPERIENCES ANY OF THESE SYMPTOMS, SEEK FRESH AIR IMMEDIATELY. If symptoms
persist, seek medical attention. Shutdown the unit and do not restart until it has been inspected and repaired.
This document may not be reproduced or distributed in any form or by any means, graphic, electronic, or mechanical, including but not
limited to photocopying, scanning, recording, taping, e-mailing, or storing in information storage and retrieval systems without the written
permission of Westerbeke. Products that are referenced in this document may be trademarks and/or registered trademarks of their
respective owners. Westerbeke makes no claim to these trademarks. While every precaution has been taken in the preparation of this
document, individually, as a series, in whole, or in part, Westerbeke, the publisher, editor, and other contributors assume no responsibility
for errors or omissions, including any damages resulting from the express or implied application of information contained in this document
or from the use of other products, services, recommendations, or policies that may accompany it. In no event shall Westerbeke, publishers,
authors, or editors of this guide be liable for any loss of profit or any other commercial damage caused or alleged to have been caused
directly or indirectly by this document.
page ii
Operator Manual for Marine Gasoline Generators
The shelf life of E-10 is only 60-90 days. It will start to break down over
time and leave deposits in the fuel system. E-10 will also lose its volatility
WARNING: Gasoline with an ETHANOL content
very quickly. We recommend using a NON-ALCOHOL based fuel
rating higher than 10% (E-10) is not allowed and stabilizer in your fuel all the time. The reason we are recommending a
may void warranty. Read the precautions below non-alcohol-based stabilizer is to avoid adding even more alcohol to the
from E-10 Service Bulletin #251 issued by fuel. There are several good petroleum-based products on the market.
Westerbeke Corporation.
Another characteristic of E-10 is its ability to absorb water directly from
the atmosphere through the open vent system of your boat tank. In just
Since 1990, the U.S. government has mandated the use of oxygenated 100 days at 70% humidity, E-10 can absorb enough water to reach its
fuels to reduce carbon emissions into the atmosphere. Congress had phase separation point. To avoid this from occurring, use up the fuel as
previously mandated the use of MTBE (methyl tertiary butyl ether) as this quickly as you can. Try to plan on turning the fuel over as quickly as
oxygenate. This legislation expired in May 2006 because MTBE is a known possible by running the tank low before any extended periods of non-
carcinogen and is also a ground water contaminant. Since then, in new use. Then fill up just before the next trip out. Avoid having E-10 fuel sit
energy legislation, Congress mandated the use of ethanol as the unused in the tank for an extended period.
oxygenate. Ethanol, an alcohol-based fuel produced from corn is more E-10 Precautions
environmentally friendly.
▪ Do not mix MTBE fuel with E-10 fuel.
About E-10 ▪ Keep water out of your fuel tank.
E-10 is a blend of 10% ethanol and 90% gasoline and is the mixture now ▪ Run a non-alcohol-based fuel stabilizer additive at all times.
offered at most fuel stations. The use of E-10 in your car should have no ▪ The more you use your boat the less likely you are to have problems.
real effect on its operation. The use of E-10 in the marine marketplace, Don't leave large loads of fuel in the boat for lengthy periods of time.
however, will cause us to take some precautions. ▪ There are approximately 5 to 8 percent fewer BTUs in E-10 (less
Ethanol, being an alcohol-based product, is quite different from MTBE power per gallon).
which is an ether-based product. Ethanol is sort of a double-edged sword ▪ Have a good water-separating fuel filter installed if you don't already
when it comes to its ability to mix with water. E-10 can hold up to four have one.
teaspoons of water per gallon but can hold only 0.15 teaspoons of water ▪ Keep several spare filters on board. You should also have a kit in a
per gallon when in solution. This is good, as it will allow your engine to sealable bucket that will seal up old filters and gas for safety and the
burn water that finds its way into your fuel tank up to this 4-teaspoon per correct tools to change your filter. E-10 fuel will clean your fuel system
gallon limit. The problem comes when one gets beyond this limit. and consequently will often clog filters after changing.
As was the case with MTBE fuel, E-10 will also phase separate when it gets ▪ Be aware of potential points of water intrusion into fuel tanks. Check
beyond the saturation point. Phase separation occurs when the gasoline deck fill cap O-rings and fuel vents.
and water are separated and the gasoline floats on top of the water. With ▪ Ask your fuel supply source or marina about the ethanol content of
MTBE, one could simply pump the water out from under the fuel or let their fuel.
the filters remove it and burn the gasoline left behind. MTBE reacts quite ▪ Check and, if necessary, replace rubber fuel lines.
differently with water than does ethanol. For this reason, the two fuel ▪ Check and clean carburetors on older models.
blends should not be mixed when transitioning from MTBE to E-10.
(Note: The original bulletin was written in 2006. In 2018 and future years, mixing with Damage caused by contamination from water, foreign particles,
MTBE is no longer a primary concern since it is no longer available.) sludge, or gums entering or forming in the engine or fuel system is
Ethanol is a solvent and tends to clean any dirt or contaminants on not covered by the Westerbeke Corporation limited warranty.
contact. For the consumer, this means that any dirt currently in the fuel
system will be mixed into solution and scrubbed out by the fuel filters.
This results in the need for the consumer to change fuel filters frequently.
page iii
Operators Manual for Gasoline Generators 1 Important Safety Information
CONTENTS
3 Installation 10
3.1 Codes and Regulations............................................................................................................................ 10
3.2 Carbon Monoxide Detector .................................................................................................................... 10
3.3 Siphon-Break Requirements ................................................................................................................... 10
3.4 Exhaust System Requirements................................................................................................................ 11
3.5 Remote Oil Filter .................................................................................................................................... 11
5 Maintenance 21
5.1 Maintenance Schedule ........................................................................................................................... 21
5.2 Maintenance: Fuel System ...................................................................................................................... 23
5.3 Maintenance: Cooling System ................................................................................................................ 25
5.4 Maintenance: Engine .............................................................................................................................. 28
5.5 Maintenance: Connections, Motors, and Circuit Breakers ...................................................................... 33
7 Wiring Diagrams 39
7.1 Remote Start/Stop Panels............................................................................................................. 39
page iv
Operators Manual for Gasoline Generators 1 Important Safety Information
9 Generator Specifications 42
9.1 Specifications: Engine .............................................................................................................................42
9.2 Specifications: Fuel System .....................................................................................................................42
9.3 Specifications: Electrical System .............................................................................................................42
9.4 Specifications: Air Requirements ............................................................................................................42
9.5 Specifications: Cooling System ................................................................................................................43
9.6 Specifications: Lubrication System ..........................................................................................................43
9.7 Specifications: AC Generator (Single Phase) ............................................................................................43
9.8 Specifications: Ignition System ...............................................................................................................43
9.9 Specifications: Engine Component Tightening Torque ............................................................................44
page v
1 Operators Manual for Gasoline Generators
LIST OF FIGURES
page vi
Operator Manual for Gasoline Generators 1
▪ All fuel vapors are highly explosive. Use extreme care when handling
1
and storing fuels. Store fuel in a well-ventilated area away from spark-
Important Safety Information producing equipment and out of the reach of children.
▪ Do not fill the fuel tank(s) while the engine is running.
▪ Shut off the fuel service valve at the engine when servicing the fuel
Read this manual carefully. Most accidents are caused by failure to follow system. Take care in catching any fuel that might spill. Do not allow any
fundamental rules and precautions. Know when dangerous conditions exist smoking, open flames, or other sources of fire near the fuel system or
and take the necessary precautions to protect yourself and other people, engine when servicing. Ensure proper ventilation exists when servicing
machinery, and property. As the owner or operator, always observe the the fuel system.
following safety risks and advisories provided for your convenience. This ▪ Do not alter or modify the fuel system.
important safety information aligns with American Boat and Yacht Council ▪ Be sure all fuel supplies have a positive shut-off valve.
(ABYC) standards; however, safety risks are not limited to the following list ▪ Be certain fuel line fittings are adequately tightened and free of leaks.
and the responsibility for the identification of potential and actual risks and ▪ Make sure a fire extinguisher is installed nearby and is properly
for compliance with all safety advisories, maintenance activities, and other maintained. Be familiar with its proper use. Extinguishers rated ABC by
conditions belongs exclusively to you as the owner or operator. the NFPA are appropriate for all applications encountered in this
environment.
Risk of Battery Explosion or Battery Acid Burns
WARNING: Review all safety information. Failure ▪ Battery explosions can cause Injury or death.
to observe the risks, warnings, and required ▪ Do not smoke or allow an open flame near the battery being serviced.
actions can result in damage, injury, or death. Lead acid batteries emit highly explosive hydrogen gas, which can be
ignited by electrical arcing or lit tobacco products. Shut off all electrical
equipment in the vicinity to prevent electrical arcs during servicing.
Risk of Electric Shock
▪ Never connect the (-) negative battery cable to the (+) positive
▪ Do not touch the high-voltage AC electrical connections while engine connection terminal of the starter solenoid.
is running, or when connected to shore power. ▪ Do not test the battery condition by shorting the terminals together.
▪ Do not operate this machinery without electrical enclosures and covers Sparks could ignite battery gases or fuel vapors.
in place. ▪ Ventilate any compartment containing batteries to prevent
▪ Shut off electrical power before accessing electrical equipment. accumulation of explosive gases.
▪ Use insulated mats whenever working on electrical equipment. ▪ To avoid sparks, do not disturb the battery charger connections while
▪ Make sure your clothing and skin are dry, not damp (particularly shoes) the battery is charging.
when handling electrical equipment. ▪ Avoid contacting the terminals with body parts, tools, and other objects
▪ Remove watches and jewelry before working on electrical equipment. to prevent burns or sparks that could cause an explosion. Remove
Risk of Accidental Start wristwatches, rings, jewelry, and other personal devices before handling
▪ Accidental starts can cause injury or death. the battery.
▪ Turn off the DC breaker on the control panel or turn the battery selector ▪ Turn the battery charger off before disconnecting the battery
switch to off before servicing the engine. connections. Remove the (-) negative lead first and reconnect it last
▪ Verify all covers, guards, and hatches are re-installed and all personnel when servicing the battery.
are clear of the engine before starting. ▪ Sulfuric acid in batteries can cause severe injury or death.
Risk of Burns ▪ Batteries contain corrosive sulfuric acid, which may splash on the skin
or into the eyes inadvertently when removing electrolyte caps.
▪ Do not touch hot engine parts or exhaust system components.
▪ When servicing the battery, or checking the electrolyte level, wear
A running engine gets very hot!
rubber gloves, a rubber apron, and eye protection. If acid contacts skin
or eyes, wash it off at once with water.
Risk of Exposure to Toxic Exhaust Fumes and Gases
WARNING: Steam burns can cause injury or death.
▪ Carbon monoxide (CO) is an invisible, odorless, and deadly gas.
Inhalation produces flu-like symptoms, nausea, and even death.
▪ Monitor engine antifreeze coolant level at the plastic coolant recovery Symptoms of carbon monoxide inhalation or poisoning include
tank and periodically at the filler cap location on the water jacketed vomiting, dizziness, headache, inability to think coherently, throbbing in
exhaust manifold, but only when the engine is COLD. temples, muscular twitching, nausea, weakness, and fatigue.
▪ In case of an engine overheat, allow the engine to cool before touching ▪ Ensure that the exhaust system is adequate to expel gases discharged
the engine or checking the coolant. from the engine. Check the exhaust system regularly for leaks and make
▪ Burns may also result from fires or explosions. sure the exhaust manifold/water-injected elbow is securely attached.
Risk of Fire ▪ Be sure the unit and its surroundings are well ventilated. Run blowers
▪ Fires can cause injury or death. when running the generator set or engine.
▪ Gasoline and diesel fuel spills or vapors can ignite in a flash fire. ▪ Do not run the generator set or engine unless the boat is equipped with
▪ Do not smoke or permit flames or sparks to occur near the fuel system, a functioning marine carbon monoxide detector that complies with
carburetor, fuel line, filter, fuel pump, while bleeding the fuel system or ABYC A-24. Consult your boat builder or dealer for installation of
other potential sources of spilled fuel or fuel vapors. approved detectors. For additional information, refer to educational
▪ Use a suitable container to catch all fuel when removing the fuel line, information about carbon monoxide in ABYC TH-22.
carburetor, or fuel filters. ▪ Do not use copper tubing in diesel exhaust systems. Diesel fumes can
▪ Keep the compartment and the engine/generator clean and free of rapidly destroy copper tubing in exhaust systems. Exhaust sulfur causes
debris to minimize the chances of fire. Wipe up all spilled fuel and rapid deterioration of copper tubing resulting in exhaust/water leakage.
engine oil. ▪ Do not install exhaust outlet where exhaust can be drawn through
▪ Do not operate with the air cleaner/silencer removed. Backfire can portholes, vents, or air conditioners. If the engine exhaust discharge
cause severe injury or death. outlet is near the waterline, water could enter the exhaust discharge
outlet and close or restrict the flow of exhaust.
Risk of Explosion ▪ Avoid overloading the craft.
▪ Explosions from fuel vapors can cause injury or death.
Risk of Injury from Moving Parts
▪ Follow re-fueling safety instructions. Keep the vessel hatches closed
when fueling. Open and ventilate cabin after fueling. Check below for ▪ Rotating parts can cause injury or death.
fumes or vapor before running the blower. Run the blower for four ▪ Do not service the engine while it is running. If a situation arises in which
minutes before starting your engine. it is necessary to make operating adjustments, use extreme care to
avoid touching moving parts and hot exhaust system components.
page 1
1 Operator Manual for Gasoline Generators
▪ Do not wear loose clothing or jewelry when servicing equipment; tie In the last row of the table, 1200 ppm is the so-called IDLH concentration:
back long hair and avoid wearing loose jackets, shirts, sleeves, rings, Immediately Dangerous to Life and Health.
necklaces or bracelets that could be caught in moving parts. A city in California characterizes the effect of CO concentration this way:
▪ Do not work on machinery when you are mentally or physically ▪ 25 ppm: Permissible exposure level, no apparent toxic symptoms.
incapacitated by fatigue. ▪ 100 ppm: No poisoning for long period. Allowable for several hours.
▪ Make sure all attaching hardware is properly tightened. ▪ 200 ppm: Should not be exposed above this level for any period of
▪ Always keep protective shields and guards in their respective places. time. A possible mild frontal headache in two to three hours.
▪ Do not check fluid levels or drive belt tension while engine is running.
Even though the generator normally produces low levels of CO, an
▪ Do not allow swimming or other activity near the exhaust discharge
untreated exhaust leak would be extremely dangerous. For this reason, it is
opening for the generator while the generator is operating. Carbon
extremely important to install a CO detector near the generator and to be
monoxide poisoning or death can occur.
sure it is always turned on and functioning properly. If this detector sounds,
Noise Hazard do not turn it off, assuming it is a false signal.
▪ High noise levels can cause hearing loss. You cannot taste, smell, or otherwise detect CO. Leave the detector on, turn
▪ Never operate an engine without its muffler installed. off all engines and generators, evacuate the boat leaving ports and hatches
▪ Do not run the engine with the air intake (silencer) or flame arrestor open, and seek professional help.
removed.
As soon as CO leaves the exhaust outlet, the level is subject to dilution in
▪ Do not run engines for long periods with their enclosures open (when
the open air. The closer a person is to the exhaust outlet, the higher the
installed).
concentration of CO.
Safety Standards for Gasoline Engines and Generators
In a closed space, such as the engine compartment, the boat, or underneath
Many standard safety tips, notes, cautions, and warnings are repeated in a stem swim platform, concentrations will potentially rise to the undiluted
this manual to highlight critical information. Read all manuals carefully, level emanating from the exhaust system due to a lack of fresh air to dilute
maintain your equipment, and follow all safety procedures. the exhaust gas. Therefore, one should never rely on dilution of the exhaust
Installing a gasoline engine or generator should begin with a thorough to provide a margin of safety.
examination of the American Boat and Yacht Council (ABYC) standards. Westerbeke multiport EFI generators achieve reduction of CO by precise
These standards are from a combination of sources including the USCG and control of the engine air/fuel ratio coupled with after-treatment in a special
the NFPA. Applicable sections of the ABYC standards include: catalyst. CO emissions are not the same for every model because each
▪ H-2 Ventilation for Boats using Gasoline engine is different. Also, certain fuel system components are common
▪ H-24 Gasoline Fuel Systems across several engine models being adequate for some and extra-adequate
▪ P-1 Installation of Exhaust Systems for Propulsion and Auxiliary Engines for others, thus producing different CO levels for different models.
▪ P-4 Marine Inboard Engines and Transmissions The fuel system which accomplishes the required precise air/fuel ratio
▪ E-11 AC and DC Electrical Systems on Boats control is comprised of many different components: purchased sub-
Read the following ABYC, NFPA, and USCG publications, safety codes, and assemblies, machined castings, sensors, electronics and others. Because of
standards. Follow their recommendations when installing all engines and the extreme level of CO reduction, any variability in the functioning of any
generators. All installations in the United States must comply with the Code these components can and will cause variability of the CO output.
of Federal Regulations (CFR). CO concentration also varies with load. Usually, but not always, the worst-
▪ ABYC Standards and Technical Information Reports for Small Craft case CO concentration occurs at maximum load.
American Boat and Yacht Council Inspection
613 Third Street, Suite 10 The catalyst is critical for minimizing engine CO exhaust emissions. Any
Annapolis, MD 21403 water intrusion into the exhaust system can quickly compromise the proper
www.abycinc.org operation of the catalyst. Inspection of the catalyst at the prescribed
▪ NFPA Fire Protection Standard for Motor Craft intervals is critically important.
National Fire Protection Association Use a CO analyzer to check for the presence of CO while the engine is
11 Tracy Drive running. See 5.4.9 Exhaust System Maintenance.
Avon Industrial Park Westerbeke exhaust system installation instructions must be adhered to.
Avon, MA 02322
NOTE: Water intrusion is not a product defect and is not covered under
http://www.nfpa.org
your Westerbeke product warranty or the emissions-specific warranty
▪ United States Coast Guard (USCG) 33CFR183: Boats and Equipment mandated by various regulating authorities such as EPA and CARB.
U.S. Government Printing Office Maintenance of fuel filters, air filters, and any other components affecting
Washington, D.C. 20404 the flow of air or the flow of fuel to the engine is critically important.
www.gpo.gov or www.ecfr.gov
The catalyst must be inspected, and replaced if necessary, every 500 hours
Carbon Monoxide from CO/multiport EFI Generators of engine operation: Catalyst performance will degrade over time. As the
generator accumulates operating hours, CO concentrations will increase.
Carbon monoxide (CO) is a component of engine exhaust. It is a colorless,
tasteless, odorless, lighter than air poisonous gas that can kill you without Verification of satisfactory CO levels must be done seasonally or every 250
any warning. CO poisoning is one of the major safety risks associated with hours (whichever occurs first): Verification involves actual sampling of
boating. It is a threat that must not be underestimated. Westerbeke exhaust gas with an appropriate CO analyzer.
multiport EFI generators are designed to dramatically reduce normal levels There are two locations where exhaust gas can be sampled:
of CO in the engine exhaust. Several standards for CO have been published, ▪ Dry, but hot, exhaust can be sampled at the plugged tapped hole in the
expressed in parts per million (ppm) and hours of exposure: exhaust elbow intended for back pressure measurements.
Measurements at this location may not be practical in all instances due
Table 1: Emissions Exposure Standards
to the high exhaust temperature, temperature limits of the analyzer,
Regulator CO Level (ppm) Max Exposure (Hours) safety concerns over temperatures involved or the possibility of high
EPA 9 8.0 levels of CO.
ACGIH 25 8.0 ▪ The other location is the vessel exhaust outlet, which contains entrained
cooling water (except dry stack exhaust systems). Only analyzers with
EPA 35 1.0
probes should be used at this location and it is critical that the probe
NIOSH 35 8.0
not ingest water. Probe-type analyzers have an air pump drawing a gas
OSHA 50 8.0 sample through the probe. They tend to ingest water when it is present.
ACGIH 125 0.5
Follow these tips:
NIOSH 200 0.0
▪ Read and follow the CO analyzer manufacturer’s instructions for proper
NIOSH (IDLH) 1200 0.0 operation of the analyzer..
page 2
Operator Manual for Gasoline Generators 2 Introduction
▪ Aim the probe downwards with the opening pointed in the direction of Carefully review operator, installation, and other manuals and information
the water flow and just out of the flow. you receive with your generator. If you are unsure whether the installation,
▪ Position the analyzer as high as possible with the tubing leading to the use, maintenance, or service of your generator is authorized, seek assistance
probe running continuously downhill. from an approved Westerbeke dealer.
▪ Observe the usually translucent tubing between the probe and the California genset users may use the table below as an aid in locating
analyzer and be sure no water is ingested. If any water is ingested into information related to the California Air Resources Board emissions control
the analyzer, it must be repaired and recalibrated or replaced. requirements.
▪ When measuring CO at the exhaust outlet be aware of the ambient CO
level by also measuring CO away from and upwind of the exhaust Table 2: Emissions Control Information
outlet, especially in marinas. The CO level at the exhaust outlet will be
influenced upwards by the ambient level. Emissions Warranty See the California emissions control
Information warranty statement in the same packet
▪ Whenever taking the time to verify proper CO concentration from the of information as this manual when the
exhaust with a CO analyzer, always use the analyzer to sniff around the genset is shipped from the factory.
engine looking for CO from exhaust leaks. Pay close attention to the
Engine Fuel The engine is certified to operate on
connection of the cylinder head to the exhaust manifold, the exhaust Requirements unleaded gasoline. See 9.2
manifold to the water-injected exhaust elbow, and all subsequent Specifications: Fuel System.
downstream exhaust components and hoses.
Engine Lubricating See 4.3 Engine Oil and 9.6
▪ Exhaust gas that has not yet passed through the catalyst is raw, Oil Requirements Specifications: Lubrication System.
untreated, and very high in CO content.
Engine Adjustments To learn more about the Electronic
▪ Analyzers usually require periodic calibration. Follow the instructions
Control Unit (ECU), see the Westerbeke
that come with the analyzer very carefully regarding calibration. Service Manual for your product model.
▪ The following manufacturers offer CO analyzers: Extech, TIF, Testo, TSI,
Engine Emission The engine emission control system
Bacharach, Fluke, Monoxor, Fyrite, Zellweger Analytics, Industrial Control System consists of engine design and precision
Scientific, GFG, TPI, Teledyne, and others. manufacturing.
▪ Westerbeke recommends analyzers with a probe connected to the
Engine Valve
analyzer by a length of transparent tubing. They are slightly more Adjustment
expensive than those with the sensor built-in to one end of the analyzer,
but they allow you to sample the exhaust coming out of the boat Engine Ignition
Timing
exhaust outlet. See 5.1: Maintenance Schedule.
Catalyst
California Exhaust Emissions Standards
Oxygen Sensor
This genset meets the requirements of the California Exhaust Emissions
Standards as stated on the nameplate. California users of this genset should
be aware that unauthorized modifications or replacement of fuel, exhaust, Back Pressure
air intake, or speed control system components that affect engine emissions
are prohibited. Unauthorized modification, removal or replacement of the
engine label is prohibited.
Federal Emissions Compliance Period
The Federal Emissions Compliance Period referred to on the nameplate
indicates the number of operating hours for which the engine has been
shown to meet Federal Emissions requirements:
▪ Category A = 1000 hours
▪ Category B = 500 hours
▪ Category C = 250 hours
page 3
2 Introduction Operator Manual for Gasoline Generators
2 Introduction
This Westerbeke generator is a product of our many years of experience and advanced technology. We take
great pride in the superior durability and dependable performance of our engines and generators. Thank you
for selecting Westerbeke.
To get the full use and benefit from your generator, it is important that you operate and maintain it correctly.
This manual is designed to help you do this. Please read this manual carefully and observe all the safety
precautions throughout. Should your generator require servicing, contact your nearest Westerbeke dealer.
WARNING: Carbon monoxide emissions can cause injury or death. Mount carbon monoxide detectors in all living
quarters on the vessel.
2.2 Documentation
■ This is your Operators Manual.
■ An Installation Manual and associated parts information are available online.
Visit www.westerbeke.com.
You can also order printed documentation from your local Westerbeke/Universal dealer. Fees and shipping
charges may apply.
page 4
2 Introduction Operator Manual for Gasoline Generators
page 5
2 Introduction Operator Manual for Gasoline Generators
page 6
2 Introduction Operator Manual for Gasoline Generators
CAUTION: Procedures, which can result in the damage or destruction of your engine if not properly followed.
WARNING: Procedures which can result in personal injury or death if not strictly observed.
CAUTION: Technical information is provided in our documentation for your reference and convenience. Westerbeke
recommends that your engine, generator or climate control system is serviced and/or installed only by a qualified
Westerbeke distributor or dealer.
❑ Properly install, configure, and prepare your unit for safe operation.
❑ Verify that you have an efficient well-designed exhaust system that includes an anti-siphon break to
prevent water from entering the engine.
❑ Change the engine oil and filters, and maintain all engine and generator components, as directed in
Chapter 5.1: Maintenance Schedule.
❑ Use clean, filtered unleaded fuel (maximum 10% ethanol).
❑ Winterize your engine as directed in Chapter 8: Lay-Up and Recommissioning.
page 7
2 Introduction Operator Manual for Gasoline Generators
CAUTION: A very small amount of amperage is being drawn from the starting battery by the electronics on the unit
when the generator is not in use. To prevent this very slow discharging of the starting battery, turn OFF either the panel
DC breaker or the starting battery switch when the unit will not be operated for an extended time.
WARNING: Jump starting or charging a battery aboard a boat is not recommended. It can create a spark which can
cause an explosion.
CAUTION: Jump starting a weak or dead battery can cause voltage spikes which can damage the electrical system on
the generator. Instead, isolate the battery from the generator and fully charge or replace it with a fully charged battery.
TIP: We also recommend carrying enough spare engine oil for an oil change and one gallon of premixed coolant for the
cooling system.
page 8
2 Introduction Operator Manual for Gasoline Generators
For your convenience, we offer two spare part kits, each packaged in a water-tight storage case:
■ Kit A includes the basic set of the most essential recommended spare parts.
■ Kit B includes everything in Kit A, plus additional spare parts for more extensive off-shore cruising.
page 9
3 Installation Operator Manual for Gasoline Generators
3 Installation
NOTE: When installing Westerbeke engines and generators, pay strict attention to all installation requirements.
In addition to the installation information in this chapter of this guide, also refer to the Marine Installation
Manual supplied with your product. That installation guide covers engines and generators and is included with
each gasoline and diesel unit. A PDF is available to download from our website at
https://www.westerbeke.com/installation manuals/installation_manual.pdf.
WARNING: If carbon monoxide is present, ventilate the area with clean air and correct the problem immediately!
Carbon monoxide, even in small amounts, is deadly.
CAUTION: Failure to use a siphon-break when the exhaust manifold injection port is at or below the load waterline will
result in raw water damage to the engine and possible flooding of the boat.
If you have any doubt about the position of the water-injected exhaust elbow relative to the vessel waterline
under the various operating conditions for your vessel, install a siphon-break, available from Westerbeke or
your local authorized Westerbeke dealer.
Figure 6: Siphon-Break (Anti-Siphon Valve) with Stainless Steel Loop
page 10
3 Installation Operator Manual for Gasoline Generators
NOTE: A siphon-break requires periodic inspection and cleaning to ensure proper operation. Failure to properly
maintain a siphon-break can result in catastrophic engine damage. Consult the siphon-break manufacturer for proper
maintenance.
CAUTION: Do not disturb the oil lines. If the oil flows in the reverse direction, the bypass valve in the filter assembly will
prevent the oil from reaching the engine, possibly causing internal engine failure. If there is no oil pressure reading, shut
down immediately and check the hose connections.
NOTE: Westerbeke is not responsible for engine failure due to the improper installation of the remote oil filter.
page 11
4 Startup and Basic Operation Operator Manual for Gasoline Generators
CAUTION: Use unleaded 89 octane gasoline or higher. Ethanol gasoline must not exceed E-10 (10%). Gasoline with
higher ethanol content is not acceptable for use in this model and will void the warranty.
NOTE: The information above supersedes all previous statements regarding synthetic oil usage.
TIP: Use the environmentally-friendly, long-lasting antifreeze that is now available. A proper 50/50 mixture as
recommended will protect the engine coolant at temperatures as low as -40° F.
page 12
4 Startup and Basic Operation Operator Manual for Gasoline Generators
WARNING: The fuel is under extreme pressure! Do not allow any smoking or open flames in the area! Clean up spilled
fuel and properly discard any used cloths, rags, and towels.
page 13
4 Startup and Basic Operation Operator Manual for Gasoline Generators
page 14
4 Startup and Basic Operation Operator Manual for Gasoline Generators
NOTE: The STOP position is also used to prime the fuel system when necessary. See 4.6 How to Bleed the Fuel
System.
4. The green LED dims indicating the engine has shut down.
4.7.2 How to Start and Stop the Generator (Remote Control Panel)
You can also perform the same steps using an optional remote control panel. Two remote start/stop panels are
available that allow for the engine/generator to be controlled from any location on the boat.
The remote panels connect to the main panel using a 15-foot or 30-foot wiring harness. You can combine
them to form a 45-foot length. To connect a remote panel, refer to the Wiring Diagram section of this manual.
Once installed, the engine/generator can be started and stopped from either the remote or the main panel.
page 15
4 Startup and Basic Operation Operator Manual for Gasoline Generators
CAUTION: Prolonged cranking can result in the exhaust filling with water and possible backflow into the engine. This
could cause catastrophic damage to your generator/engine.
NOTE: Do not attempt to re-start the generator before correcting the fault.
The LED fault shutdown display includes the following six LED light combinations that indicate to the operator
the cause of the engine automatic shutdown:
■ CHECK ENGINE
■ OIL PRESSURE
■ ENGINE TEMPERATURE
■ EXTERNAL ALARM
■ EXHAUST TEMPERATURE
■ SPEED
If the generator shuts down from one of these faults, the fault LED remains illuminated. To reset the LED, the
DC breaker on the control box must be turned OFF and then back ON.
NOTE: The CHECK ENGINE light indicates a possible emissions control problem. Immediate action should be taken to
troubleshoot and correct this problem.
The EXT ALARM light indicates a fault with the fire suppression circuit. Troubleshoot the circuit to determine
the fault (the fire suppression circuit must be closed when the circuit is active).
The 8-amp fuse protects the control panel from high amperage or short circuit condition.
The 20-amp DC circuit breaker protects the K1, K2, and K3 relays (closed circuit) from a high-amperage or
short-circuit condition.
page 16
4 Startup and Basic Operation Operator Manual for Gasoline Generators
page 17
4 Startup and Basic Operation Operator Manual for Gasoline Generators
After the first ten (10) hours of generator operation, you can increase the load to the full-load rated output,
then periodically vary the load.
Monitor the current being drawn from the generator and keep it within the generator rating. Be aware of
motor starting loads and their high current specifications. The starting amperage drawn can be 3 to 5 times
normal running amperage.
CAUTION: Do not operate the generator for long periods of time without a load being placed on the generator.
page 18
4 Startup and Basic Operation Operator Manual for Gasoline Generators
❑ Check the grounding and neutrals: Confirm that systems with a neutral line are properly grounded
as the system requires, and that generator neutral is properly connected to the load neutral. In single
phase systems, an incomplete or open neutral can supply the wrong line-to-neutral voltage on
unbalanced loads.
❑ Check the load lines: Be sure no other generator or utility power is connected to the load lines.
❑ Check the raw water intake thru-hull: Make certain the raw water thru-hull is open.
❑ Prime the fuel system: If necessary, bleed the air from the fuel system. See 4.6 How to Bleed the Fuel
System.
CAUTION: When starting the generator, it is recommended that all AC loads, especially large motors, be switched OFF
until the engine has come up to speed and, in cold climates, starts to warm up. This precaution will prevent damage
caused by unanticipated operation of the AC machinery and will prevent a cold engine from stalling.
page 19
4 Startup and Basic Operation Operator Manual for Gasoline Generators
page 20
5 Maintenance Operator Manual for Gasoline Generators
5 Maintenance
5.1 Maintenance Schedule
The maintenance intervals specify operating hours or a time interval, whichever comes first. For example, if
maintenance is due every 250 hours or six months, and you have logged 300 hours in only two months, do
not delay maintenance another four months. Use the engine hour meter to log your engine running time.
WARNING: Never attempt to perform any service while the engine is running. Wear the proper safety equipment such
as goggles or gloves and use the correct tools for each job. When servicing or replacing DC components, turn off the
DC circuit breaker on the control panel or turn off the battery switch.
TIP: A very small amount of battery drain results from the amperage being drawn from the starting battery by the
electronics on the unit when the generator is not in use. You can prevent this draw-down of the starting battery charge.
Turn OFF either the panel DC breaker or the starting battery switch when the unit will not be operational for an extended
time.
A wrench symbol in the checklist indicates a service that we recommend you have performed by a
knowledgeable mechanic.
page 21
5 Maintenance Operator Manual for Gasoline Generators
❑ Fuel Filter and O-Rings: Remove and replace fuel filter and all sealing O-rings.
❑ Inlet Fuel Filter: Remove and replace inlet fuel filter.
❑ Generator: Check that AC connections are clean and secure. Ensure wires have no chafing.
❑ Hoses: Engine hoses should be firm and tight. Replace if hoses become spongy, brittle or
delaminated. Check and tighten all hose clamps as needed.
❑ Vibration Isolators/Engine Mounts: Check vibration isolators, brackets and mounting hardware.
Replace as needed.
❑ Heat Exchanger: Open heat exchanger end cap(s) and clean out debris. Replace gasket and O-
rings.
❑ Zinc Anode: Remove and replace zinc anode.
CAUTION: Failure to replace the timing belt at the recommended interval could result in timing belt failure resulting in
major damage to the engine.
❑ Heat Exchanger: Remove the heat exchanger for professional cleaning and pressure testing.
❑ Diverter Valve: Remove and replace.
page 22
5 Maintenance Operator Manual for Gasoline Generators
page 23
5 Maintenance Operator Manual for Gasoline Generators
page 24
5 Maintenance Operator Manual for Gasoline Generators
CAUTION: Proper cooling system maintenance is critical. Many premature engine failures can be traced back to cooling
system corrosion.
CAUTION: The engine must be allowed to cool down before attempting these procedures. Not only is the surface of the
engine hot, but coolant temperatures can exceed 190° F (87° C).
page 25
5 Maintenance Operator Manual for Gasoline Generators
5. Premix fresh coolant and distilled water or use premixed 50/50 coolant.
6. Remove pressure cap.
7. Slowly add coolant into the pressure cap opening until coolant reaches the bottom of the pressure cap
opening.
8. Slowly open the coolant hose bleeder and let any air out. Bleeding is complete when coolant comes out of
bleeder with no air. It is recommended to surround the bleeder with an absorbent cloth to prevent coolant
spillage. Close bleeder.
9. Slowly open the manifold bleeder and let any air out. Bleeding is complete when coolant comes out of
bleeder with no air. It is recommended to surround the bleeder with an absorbent cloth to prevent coolant
spillage. Close bleeder.
10. Slowly add coolant into the pressure cap opening until coolant reaches the bottom of the pressure cap
housing.
11. Repeat steps 8-10 to ensure complete bleeding.
12. Securely close both bleeders.
13. Reinstall pressure cap.
14. Remove the cap on the coolant recovery tank.
a. Fill with coolant mix to halfway between LOW and MAX.
b. Replace the cap.
c. Run the engine and observe the coolant expansion flow into the recovery tank.
15. Start and run generator. Check for leaks. Confirm proper operation.
16. Stop the engine and allow it to cool. Coolant should draw back into the cooling system as the engine cools
down.
a. Add coolant to the recovery tank if needed.
b. Verify the coolant is topped off at the pressure cap.
c. Clean up any spilled coolant.
NOTE: Periodically check the condition of the pressure cap. Ensure that the upper and lower rubber seals are in good
condition and check that the vacuum valve opens and closes tightly. Carry a spare cap.
TIPS: Operating in silty and/or tropical waters may require that heat exchanger cleaning be performed more often.
page 26
5 Maintenance Operator Manual for Gasoline Generators
Figure 19: Cooling System Heat Exchanger (Left) and Thermostat (Right)
NOTE: The threads of the zinc anodes are pipe threads and do not require sealant. Sealant should not be used because
it may electrically insulate the zinc from the metal of the heat exchanger housing preventing electrolysis action on the
zinc.
5.3.6 How to Clean the Cooling System Raw Water Intake Strainer
A clean raw water intake strainer is a vital component of the engine cooling system. Include a visual inspection
of this strainer when making your periodic engine check. The water in the glass should be clear.
NOTE: Always install the strainer at or below the waterline so the strainer will always be self-priming.
page 27
5 Maintenance Operator Manual for Gasoline Generators
NOTE: If you ever run hard aground, follow the above procedure before resuming normal operation.
CAUTION: Never allow the pump to run dry. Even a short period of dry running can destroy the impeller.
The raw water pump should be inspected periodically for broken or torn impeller blades. For details, see the
maintenance schedule.
TIP: If the pump internal parts, seals, or bearings fail, it may be more cost-effective to purchase a new pump and rebuild
the original pump to keep as a spare.
If silt, leaves, or grass are caught in the strainer, the flow of raw water through the cooling system may be
restricted and the engine temperature warning light LED might illuminate.
NOTE: The external intake thru-hull opening should be of the flush type with a clear opening with no perforated or slot
type external opening. Allow the filtering to occur on the inside of the hull where there is easy access to the strainer.
5.3.8 How to Change the Cooling System Raw Water Pump Impeller
1. Close the raw-water intake valve.
2. Remove the pump cover and, using an impeller puller, screw drivers, or pliers, carefully pry the impeller out of
the pump.
3. Install the new impeller and gasket.
4. Move the blades to conform to the curved cam plate and push the impeller into the pumps housing.
5. When assembling, apply a thin coating of glycerin lubricant to the impeller and gasket.
6. Open the raw-water intake valve.
NOTE: If any of the blades have broken off the impeller they must be found to prevent blockage in the cooling circuit.
They can often be found in the heat exchanger.
page 28
5 Maintenance Operator Manual for Gasoline Generators
NOTE: The information on 5.4 (previous page) supersedes all previous statements regarding synthetic oil.
WARNING: Used engine oil contains harmful contaminants. Avoid prolonged skin contact. Clean skin and nails
thoroughly using soap and water. Launder or discard clothing or rags containing used oil. Recycle used oil properly.
Figure 20: Engine Oil Drain Hose (Left) and Oil Filter Assembly (Right)
TIP: Before doing this, verify the filter can be loosened as suggested in Step 1.
3. Remove the old oil filter with an automotive filter wrench. Place some paper towels and a plastic bag around
the filter when unscrewing it to catch any oil from inside the filter.
4. Inspect the old oil filter as it is removed to make sure that the rubber sealing gasket comes off with the old
oil filter. If this rubber sealing gasket remains sealed against the oil filter adapter, gently remove it.
5. When installing the new oil filter, wipe the filter gasket sealing surface on the oil filter adapter free of oil and
apply a thin coat of clean engine oil to the rubber sealing gasket on the oil filter.
6. Screw the filter onto the threaded oil filter stub. Where the filter contacts the base, tighten firmly by hand.
TIP: Use genuine Westerbeke oil filters. Generic filters are not recommended.
page 29
5 Maintenance Operator Manual for Gasoline Generators
TIP: Loctite Anti-Seize applied to the threaded portion of the spark plugs will retard corrosion, making future removal of
the spark plugs easier.
WARNING: Do not remove the spark plugs while the engine is hot. Allow the engine to cool before removing them.
page 30
5 Maintenance Operator Manual for Gasoline Generators
WARNING: The generator should never be started/operated without the air screen/flame arrestor properly installed.
page 31
5 Maintenance Operator Manual for Gasoline Generators
A separate group of stator windings, protected by a 30-amp, in line fuse, supplies AC voltage to a bridge
rectifier which converts the AC current to supply the charging unit. The unit senses the needs of the starting
battery and supplies a DC charge when one is needed. A 30-amp blade type fuse is in the wiring harness
behind the fuel filter.
When the generator is first started, the charger produces a low-charging rate. This charging rate rises as the
generator runs.
Figure 25: Battery Charger and 30A Fuse
TIP: There is a small DC amperage drain from the starting battery when the generator is not in use. To prevent this draw,
turn OFF the DC breaker on the generator control panel (or turn OFF the DC battery switch to the generator).
CAUTION: To avoid electrical shorts when working on the engine electrical circuit, shut OFF the engine battery switch;
however, to avoid damage to the battery charging circuit, never shut OFF the engine battery switch while the engine is
still running.
page 32
5 Maintenance Operator Manual for Gasoline Generators
3. Position the adjustable circular clamp over the two flanges and gasket, and then tighten for a secure fit.
4. Upon careful reassembly of the catalyst, new sealing gasket, and exhaust elbow, check for the presence of
CO while the engine is running. This must be performed with a CO analyzer.
WARNING : Never reuse an exhaust sealing gasket. Always replace with a new gasket.
NOTE: For information on installing exhaust systems, see the Installation Manual available at www.westerbeke.com.
page 33
5 Maintenance Operator Manual for Gasoline Generators
NOTE: The maximum AMPS TO START is greater for some smaller motors than for larger ones because the hardest
starting types (split-phase) are not manufactured in larger sizes.
Because the heavy surge of current needed for starting motors is required for only a brief period, the
generator will not be damaged if it can bring the motor up to speed quickly. If difficulty is experienced in
starting motors, turn off all other electrical loads and, if possible, reduce the load on the electric motor. Some
motor controllers can be configured to reduce the peak starting current. These are called soft-start controls.
page 34
5 Maintenance Operator Manual for Gasoline Generators
INTEGRAL
30A FUSE CONTROLLER
AC DC 30A FUSE
ROTOR WINDING
60 Hz CHARGER
50 Hz
1
BATTERY CHARGING CIRCUIT
STATOR WINDING
2
3
4
60 Hz
50 Hz
9 8 7 9 8 7
CAPACITOR CAPACITOR
page 35
5 Maintenance Operator Manual for Gasoline Generators
Set the transfer switch shown in the diagram to the OFF position. This switch prevents simultaneous
connection of shore power to generator output.
Observe the following precautions before switching from shore power to generator power:
CAUTION: Heavy motor leads should be shut off before switching shore power to generator power or vice-versa
because voltage surges Induced by switching with heavy AC loads on the vessel being operated may cause damage to
the exciter circuit components in the generator.
CAUTION: Damage to the generator can result if utility shore power and generator output are connected at the same
time. This type of generator damage is not covered under warranty; it is the responsibility of the installer to make sure all
AC connections are correct.
The second configuration shows connections for a two-wire 120-volt system from the generator with a three-
wire 120-volt boat system. In the second and third configurations, notice the repositioning of the white wire
ground load on the terminal block to the generator case. No 240-volt equipment is permitted in the ship’s
load for the first and second configurations.
page 36
6 Diagnostics and Troubleshooting Operator Manual for Gasoline Generators
Figure 31: Typical Diagnostic Software Kit (Control Box, Cable, and Other Components)
The diagnostic software runs on most Microsoft Operating Systems. It requires a minimum of 128 MB of RAM.
The communications cable plugs into a USB port. When using serial to USB adapters, the communication port
that the adapter uses must be known to configure the diagnostic software.
NOTE: The Westerbeke communications cable is unique to this diagnostic software and must be used. An incompatible
cable may damage the ECU.
The menu-driven software features easy-to-use tabbed pages to guide the user through the diagnostic
process. In addition to monitoring the operation of the engine and generator, you can also use the software to
change the ECU target frequency between 50 and 60 Hz.
page 37
6 Diagnostics and Troubleshooting Operator Manual for Gasoline Generators
NOTE: When servicing the engine/generator, the main circuit breaker (control panel) disconnects all AC power and can
be switched off and reset manually.
page 38
7 Wiring Diagrams Operator Manual for Gasoline Generators
7 Wiring Diagrams
The Wiring Diagram is available online and a printed copy is included in the standard equipment kit with your
generator.
START/STOP
RUN END
9
SWITCH
RUN INDICATOR
12V SUPPLY
START
STOP
12V
10
4
T2 T1
REMOTE
CONNECTOR
1 POWER
1 2 LED OUT - RUN INDICATOR
2 3 START SWITCH OUTPUT PNK-18GA
T6 T5 T4 T3
3 4 STOP SWITCH OUTPUT WHT/BLK/GRN–18GA
4 5 LED OUT – EXH TEMP FAIL WHT/BLK/GRY-20GA
5 6 LED OUT – EXH TEMP FAIL WHT/BLK/GRY-20GA
6 7 LED OUT – COOLANT TEMP WHT/BLK/ORG-20GA
7 8 LED OUT – LOW OIL PRESS WHT/BLK/BLU-20GA
8
Figure 33: Wiring Diagram for Start/Stop Panel Rocker Switch Only
REMOTE
CONNECTOR
1 POWER RED-18GA
1 2 RUN INDICATOR WHT/BLK/RED-18GA
2 3 START SWITCH OUTPUT
3 RUN INDICATOR
4 STOP SWITCH OUTPUT
4 5 10 9
5 6
12V RUN END
6 7 1
PNK-18GA
7 8 START
8 2
12V SUPPLY
WHT/BLK/GRN-18GA 4
STOP
START/STOP SWITCH
page 39
8 Lay-Up and Recommissioning Operator Manual for Gasoline Generators
CAUTION: Do not leave the old engine oil in the sump over the lay-up period. Lubricating oil and combustion deposits
combine to produce harmful chemicals which can reduce the life of your engine and its internal parts.
NOTE: At spring commissioning, remove the plugs and rotate the crankshaft two full revolutions. Re-install the spark
plugs, tighten each properly and connect the high tension leads fully onto each spark plug.
CAUTION: Gasoline with ethanol content higher than 10% (E-10) such as E-15 is not allowed and may void your
warranty.
page 40
8 Lay-Up and Recommissioning Operator Manual for Gasoline Generators
WARNING: Lead acid batteries emit hydrogen, a highly-explosive gas, which can be ignited by electrical arcing or a
lighted cigarette, cigar, or pipe. Do not smoke or allow an open flame near the battery being serviced. Shut OFF all
electrical equipment in the vicinity to prevent electrical arcing during servicing.
page 41
9 Generator Specifications Operator Manual for Gasoline Generators
9 Generator Specifications
9.1 Specifications: Engine
Item Description
Engine Type 3-cylinder, 4-cycle, overhead camshaft water cooled gasoline engine
NOTE: Forced ventilation should be provided to maintain generator compartment temperatures below 122° F (50° C).
page 42
9 Generator Specifications Operator Manual for Gasoline Generators
page 43
9 Generator Specifications Operator Manual for Gasoline Generators
page 44
9 Generator Specifications Operator Manual for Gasoline Generators
page 45
9 Generator Specifications Operator Manual for Gasoline Generators
Westerbeke Corporation
Myles Standish Industrial Park
150 John Hancock Rd.
Taunton, MA 02780-7319 USA
Phone: (508) 823-7677
FAX: (508) 884-9688
www.westerbeke.com
page 46