ABLOY® PBE011
Panic bar

Product description
Compatible with DIN standard lock cases. Tested and certified with ABLOY Electric locks.
Tested and certified according to EN1125 with more than 1 million cycles.

PBE011 includes outside security cover plate LH040 (solid door) or LH0730 (narrow stile door)
depending door type. Cover plate can be also covered by outside handle plate type LH0421
(outside handle solid door) or LH0751 (outside handle narrow stile door) which is ordered
separate.

Technical data
Material PBE011 Bar: Stainless steel (316)
Operating units: Zinc
Operating unit covers: Zinc
Fitting parts: Steel
Surfaces Chrome (Cr),
Satin chrome (HCr),
Brushed nickel (Niha),
Antimicrobial-coating ACTIVE
Val/Mus/Har/Gra
Standards EN1125
Door thicknesses 40–60mm, 60–80mm, 80–100mm
Suitable for fire doors Yes
Delivery batch 1 bar
Product code PBE011

Solid door Narrow stile door


28 21

56
MAX 1276
42
MAX 1263
36 38
36
Ø5
38

10 12
62

67,5

52

25 25
LH042/040
56

Ø5
21

70-72(PZ)

83

LH0750/0730
74 (RZ)
181

90-92(PZ)
78

Ø5
82

94(RZ)
108
119

225
56

145

Ø5
41 18
39 15
6

157,5

Ø5 7
86

103
Ø5 12
103