You are on page 1of 25

SK700 II - Parameter

Software Release ” A030203”


(English) D-33154 Salzkotten

-------------------------- Level 0 Commands ------------ Security Code 0000 (Default) ------------

Show CPU Software Version Numbers – Command Code 1


BOSS (W&M) Version Displayed – Function Code 1
1.1 -> BOSS (W&M) Version Displayed

Application Version Displayed – Function Code 2


1.2 -> Application Version Displayed

Show Software Flash CRC (Checksum) – Command Code 2


W&M Hash Code: (Checksum) Displayed – Function Code 1
2.1 -> W&M Hash Code: (Checksum) Displayed

IFSF CRC (Checksum) Displayed – Function Code 2


2.2 -> IFSF CRC (Checksum) Displayed

Change Level 0 PIN – Command Code 5


5.1 -> xxxx 1st Pass PIN Entry (xxxx is numeric)
5.2 -> xxxx 2nd Pass PIN Entry (Verification of 1st Pass)
5.3 -> Indicates PIN was successfully changed
5.0 -> Indicates PIN was not changed

-------------------------- Level 1 Commands ------------ Security Code 2222 (Default) ------------

View Pressure and Temperature (CNG) – Command Code 11


11.1.1 -> Read Current Pressure Side 1
11.1.2 -> Read Current Temperature Side 1
11.2.1 -> Read Current Pressure Side 2
11.2.2 -> Read Current Temperature Side 2

Show Serial Pulser Information – Command Code 15


Serial Pulser Number Displayed – Function Code 1
15.1.x ->100000000121 Serial Number Displayed

Serial Pulser SW Version Displayed – Function Code 2


15.2.x -> SW Version Displayed

Serial Pulser SW CRC Displayed – Function Code 3


15.3.x -> SW CRC Displayed
x = Meter

Show CPU serial number – Command Code 16


Pump Serial number Displayed – Function Code 1
16.1 ->123456 Pump Serial number Displayed

CPU serial number Displayed – Function Code 2


16.2 ->123456 CPU serial number Displayed
6789

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -1 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Price per Unit Values (PPU) – Command Code 20


20.1.1.1 ->1111 PPU Side 1 Grade 1 20.1.4.1 ->1444 PPU Side 1 Grade 4
20.2.1.1 ->1111 PPU Side 2 Grade 1 20.2.4.1 ->1444 PPU Side 2 Grade 4
20.1.2.1 ->1222 PPU Side 1 Grade 2 20.1.5.1 ->1555 PPU Side 1 Grade 5
20.2.2.1 ->1222 PPU Side 2 Grade 2 20.2.5.1 ->1555 PPU Side 2 Grade 5
20.1.3.1 ->1333 PPU Side 1 Grade 3 20.1.6.1 ->1666 PPU Side 1 Grade 6
20.2.3.1 ->1333 PPU Side 2 Grade 3 20.2.6.1 ->1666 PPU Side 2 Grade 6
Default -> 0 Should be 0 for all levels and all grades for all fuelling positions

Set Custom Density – Command Code 21 Not used in EU


21.1 -> xxx Grade 1
21.2 -> xxx Grade 2
21.3 -> 5 Grade 3
21.4 -> 7 Grade 4
21.5 -> 6 Grade 5
21.6 -> 11 Grade 6

Set Preset Types and Values – Command Code 22


Set Preset Keypad Mode – Function Code 1
22.1 -> 1 No Keypad Preset Default -> 1
22.1 -> 2 Five Button Preset (Value, Value, Value, Toggle, Clear)
22.1 -> 3 Incremental Preset (Value, Value, Value, Toggle, Clear)
22.1 -> 4 PPP Preset
22.1 -> 5 USA Style Five Button Preset (Value, Value, Value, Toggle, Clear)
22.1 -> 6 USA Style Incremental Preset (Value, Value, Value, Toggle, Clear)
22.1 -> 7 USA Style PPP Preset (Horizon)
22.1 -> 8 Five Button Preset (Value, Value, Value, Value, Clear)
22.1 -> 9 Incremental Preset (Value, Value, Value, Value, Clear)
22.1 -> 10 USA Style Incremental Preset (Value, Value, Value, Value, Clear)
22.1 -> 11 Incremental Preset (Horizon) (Value, Value, Value, Toggle, Clear)
22.1 -> 12 Configurable Pump Keypad Settings see CC22.10)
22.1 -> 13 Configurable Pump Five Button Preset Settings see CC22.10)
22.1 -> 14 Configurable Pump Incremental Preset Settings see CC22.10)
22.1 -> 15 Configurable Pump PPP Preset Settings see CC22.10)

Set Preset Type (Money or Volume) – Function Code 2


22.2 -> 1 Preset Type Money Default -> 1
22.2 -> 2 Preset Type Volume
22.2 -> 3 Preset Money only (no Toggle)
22.2 -> 4 Preset Volume only (no Toggle)

Set Preset Amounts per Key – Function Code 3


22.3.1 -> 5 1. Preset Value Money (here: 5 Euro) Default -> 1
22.3.2 -> 20 2. Preset Value Money (here: 20 Euro) Default -> 5
22.3.3 -> 30 3. Preset Value Money (here: 30 Euro) Default -> 10
22.3.4 -> 30 4. Preset Value Money (here: 30 Euro) Default -> 20

Set Preset Volumes per Key – Function Code 4


22.4.1 -> 1 1. Preset Value Volume (here: 1 Liter) Default -> 1
22.4.2 -> 5 2. Preset Value Volume (here: 5 Liter) Default -> 5
22.4.3 -> 10 3. Preset Value Volume (here: 10 Liter) Default -> 10
22.4.4 -> 20 4. Preset Value Volume (here: 20 Liter) Default -> 20

Preset Fill to Nearest Whole number – Function Code 5


22.5 -> 0 Fill to nearest whole number disabled Default -> 0
22.5 -> x Fill to nearest whole number(s) enabled (x = 1...5)

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -2 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Preset Fill to Nearest Volume – Function Code 6


22.6 -> 0 Fill to nearest whole Volume disabled Default -> 0
22.6 -> x Fill to nearest whole Volume enabled (x = 1...5)

Preset Fill to Nearest Money – Function Code 7


22.7 -> 0 Fill to nearest whole Money disabled Default -> 0
22.7 -> x Fill to nearest whole Money enabled (x = 1...5)

Preset PPP Special buttons – Function Code 8


22.8 -> 1 Totals via PPP Preset Keypad disabled
22.8 -> 2 Totals via PPP Preset Keypad enabled
22.8 -> 4 Stop Button via Preset Keypad enabled

Preset PPP & ENTER key – Function Code 9


22.9 -> 1 Preset value accepted without ENTER key Default -> 0
22.9 -> 2 Preset value accepted with ENTER key only

Configurable Pump Keypad Values - Function Code 10


22.10.x -> 0 No Function Default -> 0
22.10.x -> 2 Preset value accepted with ENTER key only
x = Key 1…24 Horizon Keypad / SK700 Keypad
x = Key 1…24 Horizon Keypad / SK700 Keypad

Value Key definition 13 Preset Volume 31 Language 1


0 No Function 14 Preset Amount 32 Language 2
1 Preset Value 1 15 Toggle Volume / Amount 33 Language 3
2 Preset Value 2 20 Push to Stop 34 Language 4
3 Preset Value 3 21 Money Totals 35 Language 5
4 Preset Value 4 22 Volume Totals 36 Language 6
5 Preset Value 5 23 40/70 Button 37 Language 7
6 Preset Value 6 24 Cashier Button 38 Language 8
7 Preset Value 7 25 LPG Kiosk call button 41 Bio Methan CNG 1
8 Preset Value 8 26 Grade Select 1 42 Bio Methan CNG 2
9 Preset Value 9 27 Grade Select 2 43 Bio Methan CNG 3
10 Preset Value 0 28 Grade Select 3 44 Bio Methan CNG 4
11 Clear 29 Backlight On / OFF 45 Start Button CNG
12 Enter 30 Push to Start 46 Stop Button CNG

Preset Multiplication Factor for Amount – Function Code 11


22.11 -> 0 Preset Multiplication Factor disabled Default -> 0
22.11 -> x Preset Multiplication Factor enabled (x = 1...3)

Set Mode Of Operation – Command Code 24


24 -> 1 2-Wire
24 -> 2 Stand Alone Default -> 2
24 -> 3 IFSF 1.51- LON
24 -> 4 IFSF x.xx - LON
24 -> 5 ER3
24 -> 6 Puma LAN
24 -> 7 ATCL
24 -> 8 Multi Wire Interface
24 -> 9 Australia Two-Wire Protocol 1
24 -> 10 Australia Two-Wire Protocol 2
24 -> 11 Nuovo Pignone
24 -> 12 Wayne Current Loop

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -3 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Allocation Volume – Command Code 25


25.1 -> 990 Max Allocation Volume Grade 1 (here: 990 Liter) Default -> 0
25.2 -> 990 Max Allocation Volume Grade 2 (here: 990 Liter ) Default -> 0
25.3 -> 750 Max Allocation Volume Grade 3 (here: 750 Liter) Default -> 0
25.4 -> 990 Max Allocation Volume Grade 4 (here: 990 Liter) Default -> 0
25.5 -> 990 Max Allocation Volume Grade 5 (here: 990 Liter ) Default -> 0
25.6 -> 990 Max Allocation Volume Grade 6 (here: 990 Liter ) Default -> 0

Review ATC – Command Code 27


27.1.x -> Audit Last Transaction
27.2.x -> Display Volume Correction Factor
27.3.x -> Display Fuel Density
27.4.x -> Display Temperature
27.5.x -> Gross Volume Totals
27.6 -> Software version
27.7 -> Real Time Transaction
27.8.x -> Engineering Audit
x = Meter

Change First Level PIN – Command Code 28


28.1 -> xxxx 1st Pass PIN Entry (xxxx is numeric)
28.2 -> xxxx 2nd Pass PIN Entry (Verification of 1st Pass)
28.3 -> Indicates PIN was successfully changed
28.0 -> Indicates PIN was not changed

Set Amount Limits – Command Code 31


31.1 -> 990 Max Amount Limits Grade 1 (here: 990 Euro) Default -> 0
31.2 -> 990 Max Amount Limits Grade 2 (here: 990 Euro) Default -> 0
31.3 -> 750 Max Amount Limits Grade 3 (here: 750 Euro) Default -> 0
31.4 -> 990 Max Amount Limits Grade 4 (here: 990 Euro) Default -> 0
31.5 -> 990 Max Amount Limits Grade 5 (here: 990 Euro) Default -> 0
31.6 -> 990 Max Amount Limits Grade 6 (here: 990 Euro) Default -> 0

Show Last Fuelling – Command Code 32


32 -> 1 Last Fuelling Side 1
32 -> 2 Last Fuelling Side 2

Show Auto regulation factor – Command Code 33


33 -> 1 auto regulation factor Side 1
33 -> 2 auto regulation factor Side 2

Valve Current Feedback Slow Flow Mode – Command Code 34


34 -> 1 Valve Current Feedback Disabled
34 -> 2 Valve Current Feedback Enabled

-------------------------- Level 2 Commands ------------ Security Code 1503 (Default)-----------

Set Communication Parameters - Command Code 40


Set 2-Wire, ATCL, Nuovo Pignone, Puma LAN Protocol Address – Function Code 1
40.1.1 -> 14 Protocol Address Side 1 (here 14) Default -> 0
40.1.2 -> 15 Protocol Address Side 2 (here 15) Default -> 0
Addresses Range: 2-Wire: 1...16 / ATCL: 1...8 / Puma LAN: 1…16 / Nuovo Pignone: 1...8
Addresses Range: WCL: 1...16

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -4 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set 2-Wire, ATCL, Nuovo Pignone, Puma LAN Baud Rate – Function Code 2
40.2 -> 1 Baud Rate 5787 bps ......................... 2-Wire, WCL
40.2 -> 2 Baud Rate 4800 bps ......................... 2-Wire, .. ATCL,.....Puma LAN
40.2 -> 3 Baud Rate 1200 bps ......................... .............. ATCL......
40.2 -> 4 Baud Rate 9600 bps ......................... 2-Wire, .. ATCL
40.2 -> 5 Baud Rate 19200 bps ....................... 2-Wire
40.2 -> 6 Baud Rate 2400 bps ......................... Nuovo Pignone
40.2 -> 7 Baud Rate 10 Mbps .......................... 2-wire TCP/IP
40.2 -> 8 Baud Rate 100 Mbps ........................ 2-wire TCP/IP
If Operation Mode: 2-Wire, ER3 Default -> 1
If Operation Mode: ATCL, Australia Two-Wire, Puma LAN Default -> 2
If Operation Mode: Nuovo Pignone Default -> 6

Set IFSF - LON Node Address – Function Code 3


40.3 -> 5 IFSF - LON Node Address (here: 5) Default -> 27

Set Communication Lost – Function Code 4


40.4 -> 1 Set suspend Default -> 1
40.4 -> 2 No suspend

Set Real time Volume – Function Code 5


40.5 -> 1 Real-Time Money Default -> 1
40.5 -> 2 Real time Volume
40.5 -> 3 Real time Money & Volume

Set Volume Pulse Scale (Multi Wire Interface) – Function Code 6 (*) Level 4 Command
40.6 -> 100 100 Pulses / Liter Default -> 100
40.6 -> 50 50 Pulses / Liter
40.6 -> 10 10 Pulses / Liter

Set Amount Pulses (Multi Wire Interface) – Function Code 7 (*) Level 4 Command
40.7 -> 1 Amount Pulses enabled Default -> 1
40.7 -> 2 Amount Pulses disabled

Set Auto Authorization (Multi Wire Interface) – Function Code 8 Level 4 Command
40.8 -> 1 Auto Authorization enabled Default -> 1
40.8 -> 2 Auto Authorization disabled

Set start position of Pulse Channels (Multi Wire Interface) – Function Code 9 Level 4 Command
40.9 -> 1 Both Pulse Channels start with “low” Default -> 1
40.9 -> 2 Both Pulse Channels start with “high”

Set Pulse Format (Multi Wire Interface) – Function Code 10 (*) Level 4 Command
40.10 -> 1 Channel B lags channel A by 90°” Default -> 1

Set additional pulses via Multi Wire-Interface – Function Code 11


40.11 -> 1 Pulses via Multi Wire Interface and CC24 ≠ 8 disabled Default -> 1
40.11 -> 10 10 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled
40.11 -> 50 50 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled
40.11 -> 100 100 Pulses / kg via Multi Wire Interface and CC24 ≠ 8 enabled

Set Australia Two-Wire EOT Timer – Function Code 12


40.12 -> 5 Number of Seconds EOT is reported (1…10 sec.) Default -> 3

Set Keypad Preset with Remote Preset (Australia or Standard Two-Wire) – Function Code 13
40.13 -> 1 Keypad Preset Allowed with Remote Preset Default -> 1
40.13 -> 2 Keypad Preset NOT Allowed with Remote Preset

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -5 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Special EOT with 2-wire (CC24= 1) and Preset – Function Code 14
40.14 -> 1 EOT corporate 2-wire Default -> 1
40.14 -> 2 EOT with nozzle out (2-wire (CC24= 1) and Preset only)
40.14 -> 3 EOT with nozzle out (ER3 (CC24= 5) and 53.12 Maximum Fill Timeout reached)

Set Special parameter for SNIP & Fusion Master POS (Nuovo Pignone) – Function Code 17
40.17 -> 1 POS : SINP system
40.17 -> 2 POS : Fusion Master Default -> 2

Set IFSF Serial Mode (TCP/IP) – Function Code 18


40.18 -> 1 IFSF LON Mode Default -> 1
40.18 -> 2 IFSF TCP/IP Mode
40.18 -> 3 2-wire TCP/IP Mode

Set DHCP on/ioff – Function Code 19


40.19 -> DHCP enabled
40.19 -> DHCP disabled Default -> 2

Set IP Address – Function Code 20


40.20.1 -> aaa Default -> 0
40.20.2 -> bbb Default -> 0
40.20.3 -> ccc Default -> 0
40.20.4 -> ddd Default -> 0
aaa.bbb.ccc.ddd will be stored after the latest input

Set Subnet-Mask – Function Code 21


40.21.1 -> aaa Default -> 255
40.21.2 -> bbb Default -> 255
40.21.3 -> ccc Default -> 255
40.21.4 -> ddd Default -> 0
aaa.bbb.ccc.ddd will be stored after the latest input

Set Timeout for polling - Function Code 22


40.22 -> 0 Timeout for polling (0…240 sec.) Default -> 10
0 => no Communication Error (Err 50)

Set Reported Money Size (Australia or Standard Two-Wire) – Function Code 23


40.23 -> 1 2-Wire reported money size 5 Digit Default -> 1
40.23 -> 2 2-Wire reported money size 6 Digit
40.23 -> 3 2-Wire reported money size 7 Digit
40.23 -> 4 2-Wire reported money size 8 Digit

Set Reported Volume Decimal Point Location (Standard Two-Wire)– Function Code 24
40.24 -> 1 Same as on the volume display
40.24 -> 2 3 Decimal figures: XXX.XXX Default -> 2

Set 2-Wire Reported Error States in Transaction Data– Function Code 25


40.25 -> 1 Error codes in Transaction Data disabled Default -> 1
40.25 -> 2 Error codes in Transaction Data enabled

Set 2-Wire Reported VRC Error States in Transaction Data– Function Code 26
40.26 -> 1 Report VRC Error States in Transaction Data disabled Default -> 1
40.26 -> 2 Report VRC Error States in Transaction Data enabled

Set Status Response Format – Function Code 27


40.27 -> 1 Standard Response Default -> 1
40.27 -> 2 Alternate Response

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -6 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Preset Mode Without Pump Stop – Function Code 28


40.28 -> 1 Allow One Preset Default -> 1
40.28 -> 2 Allow any Preset Until Fuelling Starts

Set 2W Grade Remapping– Function Code 29


40.29 -> 1 2W Grade Remapping disabled Default -> 1
40.29 -> 2 2W Grade Remapping enabled

Set MAC address – Function Code 30


40.30 -> 1 Set MAC address Default -> 0
The Value of CC40.30 will be added to 00:50:83:30:60:00
The MAC address range 00:50:83:30:60:00 to 00:50:83:30:6F:FF

Set Port ID– Function Code 31


40.31 -> 1 Set Port ID (here 2101) Default ->2101

STP Controls – Command Code 49


Set STP Mode – Function Code 1
49.1 -> 0 STP off Default -> 0
49.1 -> 4 STP delay in seconds (2…12 sec.)

Set LPG-STP Control Mode – Function Code 4


49.4 -> 1 LPG_STP_STANDARD Default -> 1
49.4 -> 2 LPG_STP_ON_POB

Set Beeper– Command Code 51


51 -> 1 Beeper on Default -> 1
51 -> 2 Beeper off

Set Timeouts – Command Code 530


Set Beeper Timeout Value – Function Code 1 Level 3 Command
53.1 -> 0 Beeper timeout disabled (0…250 sec.) Default -> 0

Set Preset / Grade Select Timeout – Function Code 2


53.2 -> 0 Pre Select timeout disabled (0…999 sec.) Default -> 30

Set Initial Beeper Timeout – Function Code 3


53.3 -> 0 Initial Beeper Timeout disabled (0…250 sec.) Default -> 0

Set Guard Timeout – Function Code 4


53.4 -> 0 Guard Time (0…250 sec.) Default -> 5

Set Maximum Authorize Time - Function Code 5


53.5 -> 0 Max Auth Time (0…250 sec.) Default -> 0

Set Nozzle Changing Time between UHF Nozzle and Sat Nozzle per Side- Function Code 6 (new)
53.6.1 -> 0 Nozzle Changing Time Side 1 disabled Default -> 0
53.6.1 -> 15 Nozzle Changing Time Side 1 enabled (15…120 sec.)
53.6.2 -> 0 Nozzle Changing Time Side 2 disabled Default -> 0
53.6.2 -> 15 Nozzle Changing Time Side 2 enabled (15…120 sec.)

Set Display Backlight Power Safe Mode – Function Code 7


53.7 -> 0 Display Backlight Power Safe Mode (15…180 sec.) Default -> 0

Set Dead Man Button Timeout – Function Code 8


53.8 -> 0 Dead Man Button Timeout (0…30 sec.) Default -> 5

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -7 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Maximum No Flow Timeout – Function Code 11 (*)


53.11 -> 90 (0-250 sec.) 90  90 Seconds Default -> 90

Set Maximum Fill Timeout – Function Code 12 (*)


53.12 -> 0 (0-180) 6  60 Seconds Default -> 18

Set Initial Dispenser Timeout – Function Code 13


53.13 -> 0 Initial Dispenser Timeout disabled (0…999 sec.) Default -> 0

Set Stop Button Control – Command Code 56


56 -> 1 Stop 1 side only
56 -> 2 Stop both sides Default -> 2

Readout the Error Memory with the Keypad - Command Code 57


57 xx -> Volume display show xx = Number of Error
ENTER -> Jump to the Errors (the last in is shown at first)
X YY -> Volume display show X = Side / YY = Error code
Z -> Volume display show Z = Source of the Error
xx -> PPU show: xx = Number of the event
Key 1 -> Toggle between Time / Date and Error
HHMM -> Amount display show: Time information of the Error
MMTTJJ -> Volume display show: Date information of the Error
xx -> PPU show: xx = Number of the event

Special Valve Maps - Command Code 58


Set Vapour Recovery Valve Map - Function Code 2
58.2.1.1 -> 0 No valve set for Grade 1 on side 1 Default -> 0
58.2.1.2 -> 1 Valve 1 for Side 1 Set for Grade 2 Default -> 0
58.2.1.3 -> 2 Valve 2 for Side 1 Set for Grade 3 Default -> 0
58.2.1.4 -> 0 No valve set for Grade 4 on side 1 Default -> 0
58.2.1.5 -> 5 Valve 5 for Side 1 set For Grade 5 Default -> 0
58.2.1.6 -> 6 Valve 6 for Side 1 set for Grade 6 Default -> 0

58.2.2.1 -> 0 No valve set for Grade 1 on Side 2 Default -> 0


58.2.2.2 -> 1 Valve 1 for Side 2 Set for Grade 2 Default -> 0
58.2.2.3 -> 2 Valve 2 for Side 2 Set for Grade 3 Default -> 0
58.2.2.4 -> 0 No valve set for Grade 4 on Side 2 Default -> 0
58.2.2.5 -> 5 Valve 5 for Side 2 set For Grade 5 Default -> 0
58.2.2.6 -> 6 Valve 6 for Side 2 set for Grade 6 Default -> 0

Dispenser Cold Start – Command Code 59


59 -> 1 Dispenser Cold Start (*)
59 -> 2 Reset Logfile
59 -> 3 Reboot

Set Clock and Calendar – Command Code 60


Set Dispenser Time – Function Code 1
60.1 ->1215 Time (HHMM) here: 12.15 o’clock

Set Dispenser Date – Function Code 2


60.2 ->072514 Date (MMDDYY) here: 25.07.14

Leading Zero – Command Code 61


61 -> 1 Without Leading Zero Default -> 1
61 -> 2 With Leading Zero

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -8 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Fuel Leak Test (Italy) – Command Code 69


69.1 -> 1 Fuel Leak Test (Italy) disabled Default -> 1
69.1 -> 2 Fuel Leak Test (Italy) enabled
69.2 -> 500 milliseconds and Default ->2000
69.3 -> 40 millilitre Default -> 200

-------------------------- Level 3 Commands ------------ Security Code 1309 (Default)-----------

Set Fuel Density (Vapour Recovery and ATC) – Command Code 75 (*)
75.1 -> 1 Grade 1 Unleaded 95 Fuel Type and density
75.2 -> 4 Grade 2 Unleaded 98 0 = Invalid (default)
75.3 -> 5 Grade 3 Diesel 1 = Gasoline - North America (730)
75.4 -> 7 Grade 4 E85 (Ethanol) 2 = Diesel - North America (840)
75.5 -> 6 Grade 5 Leaded 98 3 = Unleaded 90/92/95 – Europe (745)
75.6 -> 11 Grade 6 LPG 4 = Unleaded 98 – Europe (745)
Default -> 0 for all Grades 5 = Diesel – Europe (833)
6 = Leaded Substitute 98 – Europe (755)
Remark: 7 = E85 Ethanol – Europe (785)
Density of 1 means no compensation with ATC 8 = Lamp Oil – Europe (800)
Density of “k0E” means: 9 = Gas Oil – Europe (850)
Calculation with Formula 1 from PTB 10 = Uncompensated with VR (1)
V0 = VT*(1-kOE*ΔT) ΔT= T-15°C 11 = LPG – Europe *) (537)
E0…E20: kOE = 1,21*10-3 1/K 12 = Uncompensated without VR (1)
E80...E100: kOE = 1,14*10-3 1/K 13 = LPG – Belgium (510)
B0…B100 kOE = 0,84*10-3 1/K (Heizöl) 14 = LPG – UK (512)
B0…B100: kOE = 0,85*10-3 1/K (Diesel/Bio-DK) 15 = E85 Ethanol without VR– Europe (785)
Care Diesel: kOE = 0,89*10-3 1/K (Care Diesel) 16 = E0…E20 w. VR – Germany (k0E)
* Für eine einwandfreie Funktion der 17 = E80…E100 w. VR – Germany (k0E)
Temperaturkompensation muss das LPG in einem 18 = B0…B100 – Germany (k0E)
Verhältnis von 70/30 (Propan zu Butan) vorliegen! 19 = LPG – 50 / 50 (546)

New Calibration Procedure – Command Code 76


Calibration fuelling – Function Code 1
76.1 -> Calibration fuelling if the ECAL Switch is opened.
76.1 -> Test fuelling if the ECAL Switch is closed.
If product has ATC then Test Fuelling is compensated – Calibration Fuelling is ever uncompensated.

Direct Input of the Calibration Factor – Function Code 2


76.2.x -> Direct Input of the Calibration Factor
x = Meter

Show meter number to selected nozzle – Function Code 3


76.3 -> Show meter number to selected nozzle

Switch on VRC Motor for VRC auto calibration– Function Code 4


76.4 -> Switch on VRC Motor for VRC auto calibration (CC91.14 = 5)

Special Function for Coriolis Mass Meter (AdBlue-/ CNG) – Function Code 5
76.5 -> Initial Installation AdBlue (AdBlue-MassMeter) (CC97.x.x =8)
76.5 -> CNG 5kg fuelling for testing

Read Serial Intelligent Pulser (SIP) Serial Number– Function Code 6


76.6.x ->100000000121 Read Serial Number (12 digits) of the SIP
x = Meter

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 -9 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Address for Serial Intelligent Pulser (SIP) – Function Code 7


76.7 -> x Set address of selected SIP
x = Meter

Set zero point of the Coriolis Meter – Function Code 8


76.8.x -> Set zero point of the Coriolis Meter
x = Meter

Set Address for Coriolis Meter (ModBus)– Function Code 9


76.9 -> x Set address of selected Coriolis Meter
x = Meter

Show Configuration of EM Totals, ETOTE and PIB – Function Code 10


76.10.1 -> 1 3 To selected nozzle - EM total needs to be connected to: Display 1 Port 3
76.10.2 -> 1 5 1st ETOTE needs to be set to 5 A0, A2
76.10.3 -> 2 9 2nd ETOTE needs to be set to 6 A0, A3
76.10.4 -> 3 6 3rd ETOTE needs to be set to 9 A1, A2
76.10.5 -> 1 1 1st PIB needs to be set to PIB 1 No Jumper
76.10.6 -> 2 7 2nd PIB needs to be set to PIB 7 J2, J3

Read/Write Low Flow Cut Off Coriolis Meter – Function Code 11


76.11.x ->05000y Read/Write Low Flow Cut Off Coriolis Meter
x = Meter; y = 0 (last digit is ever 0) Value here: 0,5000

Show K-Factor Coriolis Meter – Function Code 12


76.12.x -> Show K-Factor Coriolis Meter
x = Meter

Show Zero Point Coriolis Meter – Function Code 13


76.13.x -> Show Zero Point Coriolis Meter
x = Meter

Change Level PIN Codes– Command Code 77


Level 1 PIN Code – Function Code 1
77.1 -> xxxx See CC28 for explanation how to change PIN Code

Level 2 PIN Code – Function Code 2


77.2 -> xxxx See CC28 for explanation how to change PIN Code

Level 3 PIN Code – Function Code 3


77.3 -> xxxx See CC28 for explanation how to change PIN Code

Level 4 PIN Code – Function Code 4


77.4 -> xxxx See CC28 for explanation how to change PIN Code

Set PIN Code for Door/Panel switch Italy – Function Code 5


77.5 -> xxxx See CC28 for explanation how to change PIN Code

Set Maximum Flow Rate Per Grade – Command Code 80


80.1.1 -> 40 Flow Rate Side 1 Grade 1 = 40 l/min or 40 GPM Default -> 40
80.1.2 -> 80 Flow Rate Side 1 Grade 2 = 80 l/min or 80 GPM Default -> 40
80.1.3 -> 40 Flow Rate Side 1 Grade 3 = 40 l/min or 40 GPM Default -> 40
80.1.4 -> 38 Flow Rate Side 1 Grade 4 = 38 l/min or 38 GPM Default -> 40
80.1.5 -> 40 Flow Rate Side 1 Grade 5 = 40 l/min or 40 GPM Default -> 40
80.1.6 -> 40 Flow Rate Side 1 Grade 6 = 40 l/min or 40 GPM Default -> 40

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 10 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

80.2.1 -> 40 Flow Rate Side 2 Grade 1 = 40 l/min or 40 GPM Default -> 40
80.2.2 -> 80 Flow Rate Side 2 Grade 2 = 80 l/min or 80 GPM Default -> 40
80.2.3 -> 40 Flow Rate Side 2 Grade 3 = 40 l/min or 40 GPM Default -> 40
80.2.4 -> 38 Flow Rate Side 2 Grade 4 = 38 l/min or 38 GPM Default -> 40
80.2.5 -> 40 Flow Rate Side 2 Grade 5 = 40 l/min or 40 GPM Default -> 40
80.2.6 -> 40 Flow Rate Side 2 Grade 6 = 40 l/min or 40 GPM Default -> 40

Puma LAN Parameters– Command Code 82


Set Puma LAN active – Function Code 1
See CC24

Set Product associated nozzle 1 side A – Function Code 2


82.2 -> 1 Product associated nozzle 1 side A (here 1) Default -> 0

Set Product associated nozzle 2 side A – Function Code 3


82.3 -> 2 Product associated nozzle 2 side A (here 2) Default -> 0

Set Product associated nozzle 3 side A – Function Code 4


82.4 -> 0 Product associated nozzle 3 side A Default -> 0

Set Product associated nozzle 4 side A – Function Code 5


82.5 -> 0 Product associated nozzle 4 side A Default -> 0

Set Product associated nozzle 1 side B – Function Code 6


82.6 -> 1 Product associated nozzle 1 side B (here 1) Default -> 0

Set Product associated nozzle 2 side B – Function Code 7


82.7 -> 2 Product associated nozzle 2 side B (here 2) Default -> 0

Set Product associated nozzle 3 side B – Function Code 8


82.8 -> 0 Product associated nozzle 3 side B Default -> 0

Set Product associated nozzle 4 side B – Function Code 9


82.9 -> 0 Product associated nozzle 4 side B Default -> 0

Set Multiplicative factor of credit received on automatic function – Function Code 10


82.10 -> 1 Multiplicative factor of credit received on automatic function (here 1)
Default -> 1

Set LAN Number side A – Function Code 11


82.11 -> 1 LAN Number side A (here 1) (1…32) Default -> 0

Set LAN Number side B – Function Code 12


82.12 -> 2 LAN Number side B (here 2) (1…32) Default -> 0

Set Prepay delivery duration expressed in dozen of seconds – Function Code 13


82.13 -> 32 Prepay delivery duration (1-250 sec.) 1  10 Seconds Default -> 0

Set Not prepay delivery duration expressed in dozen of sec. Only new Passport– Function Code 14
82.14 -> 0 Prepay delivery duration (0-250 sec.) 1  10 Seconds Default -> 0

Set Min. delivered milliliters number to preserve credit – Function Code 15


82.15 -> 250 delivered milliliters (1-250 milliliters) Default -> 250

Set Min. showed milliliters number – Function Code 16


82.16 -> 29 showed milliliters (1-250 milliliters) Default -> 29

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 11 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Min. delivered milliliters number to change the nozzle – Function Code 17
82.17 -> 100 delivered ml number to change the nozzle (1-250 ml) Default -> 100

Set Max. number of times the same nozzle can be pulled out in a prepay case – Function Code 18
82.18 -> 3 Max. number of times the same nozzle can be pulled out in a prepay case (2 - 9)
Default -> 3

Set Seconds of min. level debouncing – Function Code 19


82.19 -> 9 Seconds of min. level debouncing (3 - 99) Default -> 9

Set Manual Price Type – Function Code 20


82.20 -> 0 Manual Price Type (0 - 1) Default -> 0

Set AutManPolarity – Function Code 21


82.21 -> 0 AutManPolarity (0 - 1) Default -> 0

Special options – Command Code 83


Set Vapour Recovery Hose Leak Test – Function Code 1 (*)
83.1 -> 1 without Leak Test Default -> 1
83.1 -> 2 with Italy Leak Test
83.1 -> 3 with France Leak Test

Set IFSF - LON Write Restriction – Function Code 2 (*)


83.2 -> 1 IFSF - LON write restriction disabled
83.2 -> 2 IFSF - LON write restriction enabled Default -> 2

Set Rounding Algorithm for Amount – Function Code 3 (*)


83.3 -> 1 Rounding Algorithm for Amount disabled Default -> 1
83.3 -> 2 Special Preset rounding for Poland
83.3 -> 3 Special Preset rounding for Nordic
83.3 -> 4 Special Preset rounding for Russia

Set Initial Value Suppression Algorithm (Germany) – Function Code 4 (*)


83.4 -> 1 Initial Value Suppression Algorithm disabled Default -> 1
83.4 -> 2 Initial Value Suppression Algorithm enabled
83.4 -> 3 Extended Initial Value Suppression Algorithm enabled

Nozzle back during lamp test – Function Code 5 (*)


83.5 -> 2 Zero Transaction data

Clear Display with release command in 2-Wire – Function Code 6 (*)


83.6 -> 1 Clear Display option disabled Default -> 1
83.6 -> 2 Clear Display option enabled / Clear Display option after release (Huth)

2-Wire Price change – Function Code 8 (*)


83.8 -> 1 Price change immediately Default -> 1
83.8 -> 2 Price change after pull nozzle
83.8 -> 3 Price change immediately with clear display

Set Multimedia Parameter – Function Code 9


83.9 -> 1 Multimedia Parameter disabled
83.9 -> 2 Multimedia Parameter enabled

Set ZModem Hardware Flow Control – Function Code 10


83.10 -> 1 Hardware Flow Control disabled
83.10 -> 2 Hardware Flow Control enabled Default -> 2

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 12 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Special Nozzle Release – Function Code 11 (*)


83.11 -> 1 Special Nozzle Release disabled Default -> 1
83.11 -> 2 Fiscal Nozzle Release enabled
83.11 -> 3 IVPGL Nozzle Release enabled

Set Indicator LED on Combi Display – Function Code 14


83.14 -> 1 Disabled Default -> 1
83.14 -> 2 Enabled (LED show state of VRM)
83.14 -> 3 Enabled (LED show state of VR Italy)

Set Single PPU works in Multi PPU – Function Code 15


83.15 -> 1 Disabled Default -> 1
83.15 -> 2 Enabled

Set Remote Preset Display Option - Function Code 19


83.19 -> 1 Disabled Default -> 1
83.19 -> 2 Enabled (Nuovo Pignone only)

Set LPG min Flow Rate– Function Code 21


83.21 -> 0 LPG min Flow Rate (0-10 l/min) Default -> 0

Set Audio options – Function Code 22


83.22 -> 1 Disabled Default -> 1
83.22 -> 2 CEPSA Synthesizer

Set Vibration Sensor Enabled – Function Code 23 (*)


83.23 -> 1 Disabled Default -> 1
83.23 -> 2 RB VIB Enabled

Set Australia LPG Vapour detection – Function Code 24


83.24 -> 1 Australia LPG Vapour detection stops transaction Default -> 1
83.24 -> 2 Australia LPG Vapour detection close valves
83.24 -> 3 Australia LPG Vapour detection logged only

Set unauthorized Flow Detection (PWI) – Function Code 25


83.25 -> 0 Disabled Default -> 0
83.25 -> 1-10 Set unauthorized Flow Detection (PWI) (1-10 L/min)

Configure Input 1 @ Display – Function Code 26


83.26 -> 1 Disabled Default -> 1
83.26 -> 2 Stop Button
83.26 -> 3 Start Button
83.26 -> 4 Nozzle 1
83.26 -> 5 Nozzle 2
83.26 -> 6 Nozzle 3
83.26 -> 7 Nozzle 4
83.26 -> 8 Nozzle 5
83.26 -> 9 Nozzle 6
83.26 -> 10 Over Pressure CNG
83.26 -> 11 Door Sensor

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 13 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Configure Input 2 @ Display – Function Code 27


83.27 -> 1 Disabled Default -> 1
83.27 -> 2 Stop Button
83.27 -> 3 Start Button
83.27 -> 4 Nozzle 1
83.27 -> 5 Nozzle 2
83.27 -> 6 Nozzle 3
83.27 -> 7 Nozzle 4
83.27 -> 8 Nozzle 5
83.27 -> 9 Nozzle 6
83.27 -> 10 Over Pressure CNG
83.27 -> 11 Door Sensor

Set AdBlue min Flow Rate– Function Code 28


83.28 -> 0 Set AdBlue min Flow Rate (0-50) value in 0,1 L/min Default -> 0

Set calibration volume will be count on tatals – Function Code 29 (*)


83.29 -> 1 Disabled Default -> 1
83.29 -> 2 Enabled

Set EOT voice message – Function Code 30


83.30 -> 1 Disabled Default -> 1
83.30 -> 2 Enabled
83.30 -> 3 Enabled for prepay mode

Set Alarm-Output on POB – Function Code 31


83.31 -> 1 Disabled Default -> 1
83.31 -> 2 Alarm-Output on POB 3

Set W&M test mode – Command Code 84 (*)


84 -> 1 W&M test disabled Default -> 1
84 -> 2 W&M test enabled

Set Decimal Points – Command Code 85 (*)


Set Money Decimal Point Position For Display – Function Code 1 (*)
85.1 -> 1 XXXXXX
85.1 -> 2 XXXXX.X
85.1 -> 3 XXXX.XX Default -> 3
85.1 -> 4 XXX.XXX

Set Volume Decimal Point Position For Display – Function Code 2 (*)
85.2 -> 1 XXXXXX
85.2 -> 2 XXXXX.X
85.2 -> 3 XXXX.XX Default -> 3
85.2 -> 4 XXX.XXX

Set PPU Decimal Point Position For Calculations – Function Code 3 (*)
85.3 -> 1 XXXX
85.3 -> 2 XXX.X
85.3 -> 3 XX.XX
85.3 -> 4 X.XXX Default -> 4

Set PPU Decimal Point Position For Display – Function Code 4 (*)
85.4 -> 1 XXXX
85.4 -> 2 XXX.X
85.4 -> 3 XX.XX
85.4 -> 4 X.XXX Default -> 4

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 14 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Comma/Decimal Point – Command Code 86 (*)


86 -> 1 Decimal Point
86 -> 2 Comma Default -> 2

Set Slowdown Valve – Command Code 88


88.1.1 -> 50 Slow Down Side 1 Grade 1 = 50 cl. (15…70) Default -> 50
88.1.2 -> 70 Slow Down Side 1 Grade 2 = 70 cl. (15…70) Default -> 50
88.1.3 -> 50 Slow Down Side 1 Grade 3 = 50 cl. (15…70) Default -> 50
88.1.4 -> 50 Slow Down Side 1 Grade 4 = 50 cl. (15…70) Default -> 50
88.1.5 -> 50 Slow Down Side 1 Grade 5 = 50 cl. (15…70) Default -> 50
88.1.6 -> 50 Slow Down Side 1 Grade 6 = 50 cl. (15…70) Default -> 50
88.2.1 -> 50 Slow Down Side 2 Grade 1 = 50 cl. (15…70) Default -> 50
88.2.2 -> 70 Slow Down Side 2 Grade 2 = 70 cl. (15…70) Default -> 50
88.2.3 -> 50 Slow Down Side 2 Grade 3 = 50 cl. (15…70) Default -> 50
88.2.4 -> 50 Slow Down Side 2 Grade 4 = 50 cl. (15…70) Default -> 50
88.2.5 -> 50 Slow Down Side 2 Grade 5 = 50 cl. (15…70) Default -> 50
88.2.6 -> 50 Slow Down Side 2 Grade 6 = 50 cl. (15…70) Default -> 50

Set CNG Parameter – Command Code 89 (*)


CNG Active – Function Code 1
89.1 -> 1 Disabled Default -> 1
89.1 -> 2 Enabled

Leak Test Time Car – Function Code 2 (Only Active if CC 89.47 is enable)
89.2 -> 16 Leak Test Time Car *0.5 (1…99) value in *0,5 sec Default -> 5

Leak Test Time Bus – Function Code 3 (Only Active if CC 89.47 is enable)
89.3 -> 16 Leak Test Time Bus *0.5 (1…99) value in *0,5 sec Default -> 5

Max Tank Pressure Limit to Refill Car – Function Code 4


89.4 -> 195 Max Tank Pressure Limit to Refill Car (1…270 bar) Default -> 195

Max Tank Pressure Limit to Refill Bus – Function Code 5


89.5 -> 195 Max Tank Pressure Limit to Refill Bus (1…270 bar) Default -> 195

Mid Tank Pressure Limit to Refill Car – Function Code 6


89.6 -> 150 Mid Tank Pressure Limit to Refill Car (1…200 bar) Default -> 150

Mid Tank Pressure Limit to Refill Bus – Function Code 7


89.7 -> 150 Mid Tank Pressure Limit to Refill Bus (1…200 bar) Default -> 150

Low Tank Pressure Limit to Refill Car – Function Code 8


89.8 -> 100 Low Tank Pressure Limit to Refill Car (1…200 bar) Default -> 100

Low Tank Pressure Limit to Refill Bus – Function Code 9


89.9 -> 100 Low Tank Pressure Limit to Refill Bus (1…200bar) Default -> 100

Fill Quantity Low Tank Pressure Car – Function Code 10


89.10 -> 20 Fill Quantity Low Tank Pressure Car Default -> 20
(1…250) value in 0,1 kg

Fill Quantity Low Tank Pressure Bus – Function Code 11


89.11 -> 60 Fill Quantity Low Tank Pressure Bus Default -> 60
(1…250) value in 0,1 kg

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 15 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Fill Quantity Mid Tank Pressure Car – Function Code 12


89.12 -> 10 Fill Quantity Mid Tank Pressure Car Default -> 10
(1…250) value in 0,1 kg

Fill Quantity Mid Tank Pressure Bus – Function Code 13


89.13 -> 40 Fill Quantity Mid Tank Pressure Bus Default -> 40
(1…250) value in 0,1 kg

Fill Quantity High Tank Pressure Car – Function Code 14


89.14 -> 5 Fill Quantity High Tank Pressure Car Default -> 5
(1…250) value in 0,1 kg

Fill Quantity High Tank Pressure Bus – Function Code 15


89.15 -> 20 Fill Quantity High Tank Pressure Bus Default -> 20
(1…250) value in 0,1 kg

Flow Rate to Switchover to Mid Bank Car – Function Code 16


89.16 -> 36 Flow Rate to Switchover to Mid Bank Car Default -> 36
(1…300) value in 0,1 kg/min

Flow Rate to Switchover to Mid Bank Bus – Function Code 17


89.17 -> 60 Flow Rate to Switchover to Mid Bank Bus Default -> 60
(1…300) value in 0,1 kg/min

Flow Rate to Switchover to High Bank Car – Function Code 18


89.18 -> 24 Flow Rate to Switchover to High Bank Car Default -> 24
(1…300) value in 0,1 kg/min

Flow Rate to Switchover to High Bank Bus– Function Code 19


89.19 -> 48 Flow Rate to Switchover to High Bank Bus Default -> 48
(1…300) value in 0,1 kg/min

Min Flow Rate to Stop Filling on High Bank Car – Function Code 20
89.20 -> 12 Min Flow Rate to Stop Filling on High Bank Car Default -> 12
(1…100) value in 0,1 kg/min

Min Flow Rate to Stop Filling on High Bank Bus – Function Code 21
89.21 -> 24 Min Flow Rate to Stop Filling on High Bank Bus Default -> 24
(1…100) value in 0,1 kg/min

Correction Factor for the Calculation of Max Mass Car – Function Code 22
89.22 -> 85 Correction Factor for the Calculation of Default -> 85
Max Mass Car (1…130)

Correction Factor for the Calculation of Max Mass Bus – Function Code 23
89.23 -> 85 Correction Factor for the Calculation of Default -> 85
Max Mass Bus (1…130)

Target pressure offset Car – Function Code 24


89.24 -> 10 Target pressure offset Car (0…99) in bar Default -> 10

Target pressure offset Bus – Function Code 25


89.25 -> 20 Target pressure offset Bus (0…99) in bar Default -> 20

Max Flow Rate Car – Function Code 26


89.26 -> 60 Max Flow Rate Car (1…100) value in kg/min Default -> 60

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 16 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Max Flow Rate Bus – Function Code 27


89.27 -> 100 Max Flow Rate Bus (1…150) value in kg/min Default -> 80

Failure Signal Contact – Function Code 28


89.28 -> 0 Failure Signal Contact -> Closes by Fault Default -> 0
89.28 -> 1 Failure Signal Contact -> Opens by Fault

Temperature Compensated Fill Pressure – Function Code 29


89.29 -> 1 200 bar at 15 degree Default -> 1
89.29 -> 2 250 bar at 21 degree

Leak Test Pressure Loss Car – Function Code 30 (Only Active if CC 89.47 is enable)
89.30 -> 10 Leak Test Pressure Loss Car Default -> 10
(1…50) value in *0,1 bar

Leak Test Pressure Loss Bus – Function Code 31 (Only Active if CC 89.47 is enable)
89.31 -> 10 Leak Test Pressure Loss Bus Default -> 10
(1…50) value in *0,1 bar

Max Pressure to Stop Filling– Function Code 32


89.32 -> 260 Max Pressure to Stop Filling (1…295 bar) Default -> 250

Natural Gas Density – Function Code 33


89.33 -> 75 Natural Gas Density Default -> 75
(55…90) value in 0,01 g/Liter

Select Bank Valve for Filling Stroke – Function Code 34


89.34 -> 0 No Valve
89.34 -> 1 LB Valve (Low Bank)
89.34 -> 2 MB Valve (Mid Bank) Default -> 2
89.34 -> 3 HB Valve (High Bank)

Enhanced Diagnostic Information Output – Function Code 35


89.35 -> 0 disabled Default -> 0
1 enabled

Dynamic Pressure Range – Function Code 36


89.36 -> 5 Dynamic Pressure Range (1…9) value in 0,1 bar Default -> 5

Select Button Type – Function Code 37


89.37 -> 1 Start / Stop Button Default -> 1
89.37 -> 2 Dead Man Button
89.37 -> 3 Start / Stop Button via Keypad (Russia)
89.37 -> 4 Product Sel over Keypad (Bio-Methan Button) 2 Grade
89.37 -> 5 Start / Stop over Grade Select Keys ( CNG NA )
89.37 -> 6 Product Sel over Keypad (Bio-Methan Button) 3 Grade

Hydraulic assignment for CNG pump – Function Code 38


89.38 -> 1 Standard (One Meter per Nozzle) Default -> 1
89.38 -> 2 Y - Meter (One Meter for Side 1 and Side 2)
89.38 -> 3 Nozzle Select (One Meter for 2 Nozzles Same Side)
89.38 -> 4 Bio-Methan

Transition level between mass and pressure filling procedure Car – Function Code 39
89.39 -> 0 from the beginning pressure controlled
89.39 -> xx% start with mass controlled filling and after xx% Default ->50 ??
Change to pressure controlled filling (0…80)

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 17 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Transition level between mass and pressure filling procedure Bus – Function Code 40
89.40 -> 0 from the beginning pressure controlled
89.40 -> xx% start with mass controlled filling and after xx% Default ->50 ??
Change to pressure controlled filling (0…80)

Offset to activate tank pressure calculation CAR – Function Code 41


89.41 -> 1-99 in 0.01 bar Default -> 100

Offset to activate tank pressure calculation BUS – Function Code 42


89.42 -> 1-99 in 0.01bar Default -> 100

Set displayed unit Type – Function Code 43 (*)


89.43 -> 1 Kg Default -> 1
89.43 -> 2 Norm Cubic meter see CC89.51
89.43 -> 3 Gasoline Gallon Equivalent (GGE)
89.43 -> 4 Gasoline Liter Equivalent (GLE)

Start Compressor Signal – Function Code 44


89.44 -> 1 disabled Default -> 1
89.44 -> 2 enabled

CNG Pump Type – Function Code 45


89.45 -> 1 Generic and European pump Default -> 1
89.45 -> 2 North America pump
89.45 -> 3 Russia pump

Show Pressure in PPU – Function Code 46 (*)


89.46 -> 1 disabled Default -> 1
89.46 -> 2 Show pressure in bar
89.46 -> 3 Show pressure in psi

Leak Test Mode – Function Code 47


89.47 -> 0 Disable Default -> 0
89.47 -> 1 Enable Switzerland
89.47 -> 1 Enable Austria Leak Test
89.47 -> 2 Enable Austria LPG Leak Test old
89.47 -> 3 Enable Austria Leak Test with LED

Pressure Measuring Y- Type – Function Code 48 (Only Active if CC 89.38 3)


89.48 -> 1 Hose Valve Open during Pressure Measuring Default -> 1
89.48 -> 2 Hose Valve Closed before Pressure Measuring

Overpressure safety switch with gauge – Function Code 49 (*)


89.49 -> 1 Disable
89.49 -> 2 Enable Default -> 2

Knock Over Protection – Function Code 50


89.50 -> 1 Disable
89.50 -> 2 Enable Default -> 2

Norm cubic meter conversation factor – Function Code 51 (*)


89.51 ->1000 Norm cubic meter conversation factor Default ->1000
(1000…1500) value in Nm³

Pressure controlled filling procedure – Function Code 52


89.52 -> 1 disabled Default -> 1
89.52 -> 2 enabled

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 18 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Pressure Transducer Type – Function Code 53 (*)


89.53 -> 1 BAR
89.53 -> 2 PSI Default -> 1

Level for refill in percent– Function Code 54 (*)


89.54 -> 95 Level for refill in % (80…99) Default -> 95

Target Pressure Correction CAR – Function Code 55


89.55 -> 1-99 in bar Default -> 10

Target Pressure Correction BUS – Function Code 56


89.56 -> 1-99 in bar Default -> 20

CNG_EU Nozzel Type CAR – Function Code 57


89.57 -> 1 Disable
89.57 -> 2 Enable Default -> 1

CNG_EU Nozzel Type BUS – Function Code 58


89.58 -> 1 Disable
89.58 -> 2 Enable Default -> 1

Set EOT Beeper Timeout – Function Code 59


89.59 -> 0 Disable Default -> 10
89.59- >1…255 Set EOT Beeper Timeout

Set Pressure counter – Function Code 60


89.60 -> 0 Disable Default -> 4
89.60- >2…20 Enable Pressure counter

Set Retrofit Car only – Function Code 61


89.61 -> 1 Disable Default -> 1
89.61- > 2 Retrofit Car only

Function Code 62 - Function Code 66 Not used in EU

Set Leak Timer for Ref. Pressure – Function Code 67


89.67 -> 0 Disable Default -> 7
89.67- >1…20 Set Leak Timer for Ref. Pressure *0,5sec

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 19 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

-------------------------- Level 4 Commands ------------ Security Code 0128 (Default)-----------

Set Unit Type – Command Code 90 (*)


Encore 510-2 / E500 MPD

12 34

Back = LHS = Side 1

5 6 654321 1 2 3 4 1 2 3 4
90 -> 1 Grade 1 Default -> 1
90 -> 2 Grade 1, 2
90 -> 3 Grade 1, 2, 3
90 -> 4 Grade 1, 2, 3, 4
90 -> 27 Grade 1 and/or 1, 2 (120N40S)* .......................................................... * see CC91.17
90 -> 28 Grade 1, 2, 3, 5, 6
90 -> 29 Grade 1, 2, 3, 4, 5, 6
90 -> 30 Grade 1, 2 VK Button Select
90 -> 31 Grade 1, 2 VK Button Select ........+ Grade 3 DK
90 -> 32 Grade 1, 2, 3 VK Button Select
90 -> 33 Grade 1, 2, 3 VK Button Select ....+ Grade 4 DK
90 -> 34 Grade 1, 2 VK Button Select ........+ Grade 3,4 DK
90 -> 35 Grade 1, 2 (120N40S) ...................................... + Grade 5 (AdBlue) * see CC91.17
90 -> 36 Grade 1, 2 (120N40S)*.................+ Grade 3 ................................ * see CC91.17
90 -> 37 Grade 1, 2 (120N40)* ...................+ Grade 3, 4 ................................ * see CC91.17
90 -> 38 Grade 1, 2 (120N40S)*.................+ Grade 3 + Grade 5 (AdBlue) * see CC91.17
90 -> 39 Grade 1, 2 (120N40)* ...................+ Grade 3, 4 + Grade 5 (AdBlue) * see CC91.17
90 -> 41 Grade 1 ............................................................ + Grade 5 (LPG, AdBlue)
90 -> 42 Grade 1, 2 ........................................................ + Grade 5 (LPG, AdBlue)
90 -> 43 Grade 1, 2, 3 .................................................... + Grade 5 (LPG, AdBlue)
90 -> 44 Grade 1, 2, 3, 4 ................................................ + Grade 5 (LPG, AdBlue)
90 -> 51 Grade 1 ............................................................ + Grade 5 and/or 5, 6 (120N40S)
90 -> 52 Grade 1, 2 ........................................................ + Grade 5 and/or 5, 6 (120N40S)
90 -> 53 Grade 1, 2, 3 .................................................... + Grade 5 and/or 5, 6 (120N40S)
90 -> 54 Grade 1, 2, 3, 4 ................................................ + Grade 5 and/or 5, 6 (120N40S)
90 -> 62 2+1 (blender + super-Hi) ................................. (Not used in EU)
90 -> 63 3+1 (blender + Super-Hi) ................................. (Not used in EU)
90 -> 64 2+2 (blender + Super-Hi Low and High Speed) (Not used in EU)
90 -> 65 3+2 (blender + Super-Hi Low and High Speed) (Not used in EU)
90 -> 70 Hybrid Blenders ............................................... (Not used in EU)
90 -> 71 Hybrid Blenders ............................................... (Not used in EU)
90 -> 72 Three Meter Blenders....................................... (Not used in EU)
90 -> 72 Three Meter Blenders....................................... (Not used in EU)
90 -> 77 Grade 1 and/or 1, 2 (120N40S) ........................ + Grade 5 and/or 5, 6 (120N40S)
90 -> 78 Grade 1 and/or 1, 2 (120N40S) + Grade 3 ... + Grade 5 and/or 5, 6 (120N40S)
90 -> 79 Grade 1 and/or 1, 2 (120N40S) + Grade 3, 4 + Grade 5 and/or 5, 6 (120N40S)
90 -> 80 Each Side: 1 Grade (397_G)
90 -> 81 Each Side: 1 Grade (397_G) ........................... Grade 1 (120N40S), Grade 2 (40S)
90 -> 82 Grade 1 AdBlue, Grade 2 UHF ........................ Grade 1 (AdBlue), Grade 2 (120N40S)

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 20 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Select Installed Options – Command Code 91 (*)


Set Push to Start – Function Code 2 (*)
91.2 -> 1 disabled Default -> 1
91.2 -> 2 enabled via Display
91.2 -> 3 enabled via Preset Keypad (second action)
One Preset Key must be configured as Push to Start CC22.10.x = 30
91.2 -> 4 enabled via Preset Keypad (second action – GVR version)
One Preset Key must be configured as Push to Start CC22.10.x = 30

Set Display(s) per Side – Function Code 4 (*)


91.4 -> 1 Per Side - 1 Display Default -> 1
91.4 -> 2 Per Side - 2 Displays
91.4 -> 3 Side 1 - 2 Displays, Side 2 - 1 Display
91.4 -> 4 Side 1 - 1 Display, Side 2 - 2 Displays

Set Push to Stop – Function Code 5 (*)


91.5 -> 1 disabled Default -> 1
91.5 -> 2 enabled.................................................................................. see CC56 too

Set ATC – Function Code 6 (*)


91.6 -> 1 ATC not installed Default -> 1
91.6 -> 2 ATC installed
91.6 -> 3 Monitoring enabled

Hose Retraction – Function Code 10 (*)


91.10 -> 1 Pump without Hose Retraction (OR) Default -> 1
91.10 -> 2 Pump with Hose Retraction (CR)

Set Totalizer – Function Code 11 (*)


91.11 -> 1 without Totalizer Default -> 1
91.11 -> 2 Totalizer per Hose/Meter
91.11 -> 3 Totalizer per Grade UHF only per Hose/Meter
91.11 -> 4 Totalizer related to the Pumping Unit / Motor

Set NA CNG Push to Start Button – Function Code 12 (*)


91.12 -> 1 disabled Default -> 1
91.12 -> 2 Start Button enables transaction

Read place where the Config is stored – Function Code 13 (*)


91.13 -> 1 NV data backed up on ECal Board
91.13 -> 2 NV data backed up on Display 1
91.13 -> 3 NV data backed up on Display 2
91.13 -> 4 NV data not backed up

Set Vapour Recovery VRC – Function Code 14 (*)


91.14 -> 1 without VRC Default -> 1
91.14 -> 2 with VRC
91.14 -> 3 with VRC and Monitoring (only Sandpiper II)
91.14 -> 4 with VRC and Re-regulation (only Sandpiper II)
91.14 -> 5 VR Motor Control (only Sandpiper II)

Set PPU Type – Function Code 15 (*)


91.15 -> 1 PPU per Product Default -> 1
91.15 -> 2 PPU per Side

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 21 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Lights – Function Code 16


91.16 -> 1 without Light Default -> 1
91.16 -> 2 OPT-Light - Two-Wire (external control)
91.16 -> 2 OPT-Light - IFSF - (internal control)
91.16 -> 3 Red Light Poland (Two-Wire)
91.16 -> 4 Red-Light

Set UHF Unit Type for CC90 = 27, 35, 36, 37, 38, 39 – Function Code 17 (*)
91.17 -> 1 120N40S Default -> 1
91.17 -> 2 120N40
91.17 -> 3 120S
91.17 -> 4 120

Set Preset for LPG – Function Code 19 (*)


91.19 -> 1 LPG Preset disabled Default -> 1
91.19 -> 2 LPG Preset enabled

Set tank low level presence (AAB-Board necessary) – Function Code 21 (*)
91.21 -> 1 Set tank low level presence not installed Default -> 1
91.21 -> 2 Set tank low level presence installed with local handling
91.21 -> 3 Set tank low level presence installed with remote handling

Set Kiosk Switched Stand Alone Mode (AAB-Board necessary) – Function Code 22 (*)
91.22 -> 1 Kiosk Switched Stand Alone Mode not present Default -> 1
91.22 -> 2 Kiosk Switched Stand Alone Mode present

Set Vapour Recovery Valves – Function Code 23


91.23 -> 1 Valves not installed Default -> 1
91.23 -> 2 Valves installed

Set ATC Probes for LPG (CC90 = 1, 2, 3, 4, 41, 42, 43, 44, 51, 52 and 53) – Function Code 25 (*)
91.25 > 1 1 ATC Probe per Hydraulic Default -> 1
91.25 -> 2 2 ATC Probes per Hydraulic (probes per meter).
91.25 -> 3 ATC Probe for Australia

Set Protection for changing CC24 = 2 – Function Code 26 (*)


91.26 -> 1 Protection disabled Default -> 1
91.26 -> 2 Protection enabled

Set Internal Interlocking for Petrol/LPG/CNG – Function Code 27 (*)


91.27 -> 1 disabled Default -> 1
91.27 -> 2 enabled

Set AdBlue: Preset Valves – Function Code 28


91.28 -> 1 disabled Default -> 1
91.28 -> 2 enabled
91.28 -> 3 enabled + Heizung

Set Modbus – Function Code 29 (*)


91.29 -> 1 Modbus disabled Default -> 1
91.29 -> 2 Modbus for AdBlue, CNG via VRC channel
91.29 -> 3 Modbus for AdBlue, CNG via Debug channel
91.29 -> 4 Modbus for AdBlue, CNG via 2-wire channel (stand alone only)
91.29 -> 5 Modbus for LPG via VRC channel
91.29 -> 6 Modbus for LPG via Debug channel

Not used in EU Function Code 30 - Function Code 33

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 22 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Door Switches logging – Function Code 34 (*)


91.34 -> 1 Door Switches logging not installed Default -> 1
91.34 -> 2 Door Switches logging installed

Set Pump Handle Configuration – Function Code 35 (*)


91.35 -> 1 IS Pump Handles
91.35 -> 2 PPU Pump Handles
91.35 -> 3 Either IS or PPU pump handles (both are valid) Default -> 3

Set Nozzle Select for AdBlue for Selected Grade – Function Code 35 (*)
91.35 -> x Set Nozzle Select for AdBlue for Selected Grade Default -> 0
x = Grade;

Set Sat Nozzle for Selected Grade– Function Code 36 (*)


91.36 -> x Set Sat Nozzle for Selected Grade Default -> 0
x = Grade;

Set Door Sensor Error Method – Function Code 37 Not used in EU


91.37 -> 1 log only Default -> 1
91.37 -> 2 Stop Current Transaction Only
91.37 -> 3 Disable Side
91.37 -> 4 Disable Side (Persistent)
91.37 -> 5 Disable Dispenser
91.37 -> 6 Disable Dispenser (Persistent)

Set Door Sensor Alarms – Function Code 38 Not used in EU


91.38 -> 1 disabled Default -> 1
91.38 -> 2 enabled

Log File Language – Function Code 40 Not used in EU


91.40 -> 1 English Default -> 1
91.40 -> 2 Spanish
91.40 -> 3 French

Encoder Lid Sensor Error Level – Function Code 41 Not used in EU


91.41 -> 1 Medium Default -> 2
91.41 -> 2 Major *
91.41 -> 3 Major Persistent
91.41 -> 4 Super Major
91.41 -> 5 Super Major Persistent

Encoder Lift-Off Sensor Error Level – Function Code 42 Not used in EU


91.42 -> 1 Medium Default -> 2
91.42 -> 2 Major *
91.42 -> 3 Major Persistent
91.42 -> 4 Super Major
91.42 -> 5 Super Major Persistent

Set Side Exists – Command Code 92 (*)


92 -> 1 Both Side Default -> 1
92 -> 2 Single Side left
92 -> 3 Single Side right

Set Zero PPU Option – Command Code 94 (*)


94 -> 1 Fuel with a Zero PPU disallowed Default -> 1
94 -> 2 Fuel with a Zero PPU allowed
94 -> 3 Liter counter (Combi Display needed)

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 23 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

Set Special Country Codes– Command Code 95 (***)


Set Country Code – Function Code 2 (*)
95.2 -> 0 No Country Code Default -> 0
95.2 -> 036 Australia
95.2 -> 380 Italy

Set Special Country Option – Function Code 3 (*)


95.3 -> 1 disabled Default -> 1
95.3 -> 2 Thailand
95.3 -> 3 Special Ecometer Test
95.3 -> 4 Colombia
95.3 -> 5 Philippines

Set Special Nozzle Configuration – Command Code 97 (*)


97.1.1 -> 0 Side 1 Grade 1 VK or DK Special Nozzle Type
97.1.2 -> 0 Side 1 Grade 2 VK or DK 0 = Standard Nozzle
97.1.3 -> 2 Side 1 Grade 3 LPG 1 = reserve
97.1.4 -> 4 Side 1 Grade 4 DK 40B70 2 = LPG Nozzle works as „Dead Man
97.1.5 -> 0 Side 1 Grade 5 VK or DK Button“ (5 sec delay time)
97.1.6 -> 0 Side 1 Grade 6 VK or DK 3 = reserve
4 = 40/70 Button Select
97.2.1 -> 0 Side 2 Grade 1 VK or DK 5 = LPG Nozzle with additional „Dead
97.2.2 -> 0 Side 2 Grade 2 VK or DK Man Button“ (no 5 sec delay time)
97.2.3 -> 2 Side 2 Grade 3 LPG 6 = LPG Nozzle with additional
97.2.4 -> 4 Side 2 Grade 4 DK 40B70 Start/Stop Button
97.2.5 -> 0 Side 2 Grade 5 VK or DK 7 = AdBlue with VemmTec Meter
97.2.6 -> 0 Side 2 Grade 6 VK or DK 8 = AdBlue with AdBlue-MassMeter
Default -> 0 for all Grades 9 = CNG - Pkw
10 = CNG – Bus
11 = AdBlue – Car

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 24 -
SK700 II - Parameter
Software Release ” A030203”
(English) D-33154 Salzkotten

---------------------------------------------------- Appendix ----------------------------------------------------


Keypad
Key “5” in Stand Alone Mode Show Flow Rate on Display
Key “$ TOTAL” Show Amount Totals on Display
Key “VOL TOTAL” Show Volume Totals on Display

Country Code: 036 Australia


22.1 -> 9 Incremental Preset (Value, Value, Value, Value, Clear)
22.3.4 -> 20 4. Preset Value Money (here: 20 Euro) Default -> 20
83.5 -> 2 Zero Transaction data
83.8 -> 3 Price change immediately with clear display Default -> 1
83.19 -> 2 Enabled (Nuovo Pignone only) Default -> 1
85.4 -> 2 XXX.X Default -> 4
86 -> 1 Decimal Point Default -> 2
87.1 -> 150 (0-250 sec.) 90  90 Seconds Default -> 90
87.2 -> 250 (0-250) 6  60 Seconds Default -> 180
91.5 -> 2 enabled Default -> 1
91.10 -> 2 Pump with Hose Retraction (CR) Default -> 1
91.11 -> 3 Totalizer per Grade UHF only per Hose/Meter Default -> 1
98.x -> 1 Air Sensor on (x = Grade 1…6)

83.12 -> 40 Min_Display_Vol Default ->


83.13 -> 2 Preset_Indicator_Display Default ->
83.20 -> 5 Default ->

Country Code: 380 Italy


Key “5” in Stand Alone Mode Function disabled
Key “VOL TOTAL” If CC91.11 = 2 or CC91.11 = 3 then Function disabled
Command Code 22 Level 2 Commands Security Code 1503
Command Code 24 Level 2 Commands Security Code 1503
Command Code 25 Level 2 Commands Security Code 1503
Command Code 31 Level 2 Commands Security Code 1503
Command Code 32 Level 2 Commands Security Code 1503
Command Code 33 Level 2 Commands Security Code 1503

Remark
(*) Before changing CC or FC or Value of a Parameter the Security Switch needs to be opened
(**) ECAL Switch needs to be opened
(***) It’s only possible to set CC95 once with open Security Switch.
For a new setting a hardware coldstart (CC95 is set to 000) is required.

APOLLO_DRAFT_30.2.03_ENGLISCH.DOC 24.11.2010 - 25 -