Report No.

: 220214-02G
TEST DATA SHEET

Project Name: Avery Dennison T-6500 Series High Intensity Performance


Retroreflective Sheeting (Type III/IV)
6.2 Coefficient of Retroreflection (continued)

Individual sample's Coefficient of Retroreflection may be 80% of required


so long as average of three samples meets minimum requirement.

Samples meet Coefficient of Retroreflection requirements for Type III and


Type IV Sheeting at the 0°, 90° and as the average of 0° and 90°
rotations.

6.3 Daytime Color and Luminance

Requirement: ASTM D4956 Tables 2 and 11 (Type III & IV Sheeting)


Test Method: ASTM E308, E1347, E1349, E991, E1164
(Illuminant D65, 2° Observer, Annular 45/0 Geometry)
Average of 8 reads, each read oriented 45° apart
Samples from 6.2
Instrument: Hunterlab Colorflex Spectrocolorimeter, 32 mm aperture port

Y
Sample x y
Measured Minimum Maximum
T-6500 White #1 0.3069 0.3243 45.82 27 -
T-6501 Yellow #1 0.5223 0.4675 26.45 15 45
W-6504 Orange #1 0.6310 0.3666 22.38 10 30
T-6507 Green #1 0.1269 0.4622 5.22 3.0 12
T-6508 Red #1 0.6810 0.3133 5.10 2.5 15
T-6505 Blue #1 0.1434 0.1153 4.43 1.0 10
T-6509 Brown #1 0.5041 0.3959 4.86 1.0 9.0

Samples meet Daytime Color and Luminance requirements.