Report No.

: 220214-02G Page 1 of 21
TEST REPORT
Report Date: 14 April 2022
Project Name: Avery Dennison T-6500 Series High Intensity Performance
Retroreflective Sheeting (Type III/IV)
Submitted by: Avery Dennison
Mount Prospect, IL 60056
Test Laboratory: Calcoast – ITL
San Leandro, CA 94577
Samples submitted: T-6500 White, T-6501 Yellow, W-6504 Orange (Workzone),
T-6507 Green, T-6508 Red, T-6505 Blue, and T-6509 Brown
each sample set submitted as five (5) 12 in. x 12 in.
sheets and four (4) 3 in. x 9 in. pre-weathered panels
on 14 Feb 2022
SUMMARY
Specification: ASTM D4956-19
Sheeting Type III/IV, Class 1 Backing

6.2 Coefficient of Retroreflection ...............................Passed


6.3 Daytime Color and Luminance ..................................Passed
6.4 Outdoor Weathering
Workzone exposure (12 months, W-6504 material only)........Passed
Standard exposure (36 months, all other materials).........Passed
6.5 Colorfastness ................................................Passed
6.6 Shrinkage ....................................................Passed
6.7 Flexibility ..................................................Passed
6.8 Liner Removal ................................................Passed
6.9 Adhesion .....................................................Passed
6.10 Impact Resistance ............................................Passed
6.11 Nighttime Color ..............................................Passed
S1. Fungus Resistance ............................................Passed
Written by: Approved by:

Douglas G. Cummins Mark A. Evans


Photometric Engineer Laboratory Director

Results apply only to the submitted, tested samples. This document may not be modified or reproduced except in its entirety without the expressed consent of Calcoast - ITL.