This document lists the technical requirements for the supply of self-
supporting four-legged towers, separate monopoles, Imbedded monopoles,
four-legged self-support Slim towers, four-legged rooftop towers, and
Rooftop poles with all required accessories used for GSM/UMTS and
Microwave Transmission Systems (MTS) required at BTS/Node, BTS/MTS
sites for all applicable standard heights (no guyed towers, monopoles, and
rooftops is allowed). All bidders shall consider the requirements, fulfillments
of product and the respective services and send in comprehensive
1.1.1 response.
1.2 Scope
This specification covers the supply and installation of self- supporting four-
legged towers, separate monopoles, Imbedded monopoles, four-legged self-
support slim towers, four-legged rooftop towers, and rooftop poles with all
accessories as tabulated on Table-1 below.
Maximum
Description of the Equipment
No. QTY Unit Foundation
Item/Asset/ Service Cabinet Type
Size in (Meter)
Towers, monopoles, and rooftops shall be complete in all aspects and shall
be provide with every necessary details and fittings. List of Items to be supply
shall include all complete anchoring kits, access and safety, complete
1.2.2 grounding system and aviation obstruction lights but not limited.
The successful bidder shall also be responsible for transportation and
supervision of all civil works. The complete installation of the towers,
1.2.3 monopoles, and rooftops will be also done by the bidder.
The bidder shall quote the price of the materials and the service (Supervision
1.2.4 and installation) separately in its commercial offer.
1.3 Technical guarantee
The bidder shall unconditionally guarantee that all the towers, monopoles,
and rooftops supplied shall be entirely of new manufacture using state of the
art technology and not second hand, reconditioned and/or used and shall be
1.3.1 of the highest quality to ensure reliability for which it is intend.
P.O. Box 1047 Addis Ababa Ethiopia
tel.: +251 (0) 115 5157 00
www.ethiotelecom.et
All works affecting the surface of the metal such as cutting, grinding,
1.5.1 polishing, boring, drilling etc. shall be carry out compulsorily in the factory
2 prior to galvanization.
All works of deformation of the metal structure such as bending, folding,
1.5.1 inflexion, reshaping etc. shall be carry out compulsorily in the factory prior to
3 galvanization.
The service provider shall ensure that the corners and edges, likely to cause
1.5.1 a risk to personnel on the site, are rounded off as much as possible. This
4 operation will be carry out compulsorily in the factory prior to galvanization.
Welding joints will carry out compulsorily in the factory prior to galvanization
1.5.1 and must comply with the EN ISO 15609-Part1 or AWS D1.1standards.
5
1.5.1 The bidder shall carry out erection of the towers, monopoles, and rooftops
6 in compliance with the manufacturer’s procedures, compulsorily in one go.
1.5.1 Erection by sections; assembly a section on the ground and erect it as unit
7 is prohibited.
All safety measures necessary for securing its operation will be implemented
by the bidder after having been defined according to Ethiopian works at
1.5.1 heights safety regulations.
8
The bidder shall ensure the perfect verticality of the towers, monopoles,
1.5.1 and rooftops for which a tolerance of maximum 1/360 of total height
9 (0.28%) is permitted.
1.6 Ladders, Platforms and Safety
All the sites will have a TT type grounding system built in galvanized steel
1.7.1. compliant with the next standards: a) IEC 60 364 b) ETSI EN 300 25 c) IEC
1. 62561-1 d) IEEE 837 e) IEC 62305.
P.O. Box 1047 Addis Ababa Ethiopia
tel.: +251 (0) 115 5157 00
www.ethiotelecom.et
1.7.2. The site shall have a lightning protection system provided by the bidder
1. compliant with IEC 62305 standard.
According to IEC 62305 standard the requirements for the LPS are: a) Type:
Non- Isolated b) Air Termination: Air Rod (finial, lightning arrestor) on the top
1.7.2. of the towers, monopoles, and rooftops above the structure connected with
2. down grounding conductor to the site grounded system.
P.O. Box 1047 Addis Ababa Ethiopia
tel.: +251 (0) 115 5157 00
www.ethiotelecom.et
1.7.2. The protected zone shall cover the whole area of the site. If one rod on the
4. top is not enough to achieve that additional rods will install.
1.8.1. All towers, monopoles, and rooftop towers shall have necessary aviation
1 obstruction lights.
Obstruction lights (Aircraft Warning Lighting - Aviation Lights) shall be
1.8.2 compliant to ICAO standard as follows:
For the towers, monopoles, and rooftops less than 45m height Two red
obstruction lights at the top of the towers, monopoles, and rooftops so that
a) the light is visible from every angle of azimuth.
For the towers, monopoles, and rooftops between 45m and 75 m height Two
red obstruction lights at the top of the towers, monopoles, and rooftop towers.
So that the light is visible from every angle of azimuth or Two to four red
obstruction lights (according to the towers, monopoles, and rooftops design)
at middle of the towers, monopoles, and rooftops (half of the towers,
monopoles, and rooftop towers height) the light is visible from every angle of
b) azimuth.
Location requirements for the obstruction lights: At the top of the structure,
the lights shall mount above the top part of the structure but below the
lightning arrestor. The lighting unit shall position in such a way to be
accessible from the towers, monopoles, and rooftops in safe working
c) conditions for the staff.
The obstruction lights system shall be efficient power consumption designed
(low, medium and high intensity lights will consider according to the location
1.8.3 of the towers, monopoles, and rooftop towers).
In the urban environment or near airports or other aerial traffic zones medium
intensity lights will consider. In addition, in rural environment or zones without
1.8.4 aerial traffic low intensity lights shall consider.
1.9 Markups
The towers, monopoles, and rooftops shall deliver with complete antenna
mounting steel work that will contain all the necessary accessories for rigidly
1.10. attaching and mounting of all the hardware supplied as part of antenna
1 system.
The antenna mounting steelwork shall cover all the antenna types necessary
1.10. to be installed on the respective towers, monopoles, and rooftops (BTS all
2 standards and bands, RRU, Microwave etc.)
The antenna mounting steelwork shall design to allow a nominal azimuths
adjustment of +0.50 and an elevation adjustment of +0.50.
1.10.