Questions to be asked from the Supplier Engineer for comprehensive understanding of the Sluice Gate product: General : 1.

Can you provide


information on the expected lifespan and durability of the sluice gate? How does it withstand factors such as corrosion, erosion, and prolonged
exposure to wastewater? 2.Are there any potential operational challenges or limitations associated with the sluice gate? For example, does it
require regular maintenance, and if so, what are the specific maintenance requirements? 3.What measures are in place to ensure the gate's
watertightness and prevent leakage? Are there any backup systems or redundancies in case of a failure?4.Can you explain the gate's hydraulic
performance under varying flow rates and differential pressures? How does it handle high flow velocities or sudden changes in flow conditions?
5.How does the sluice gate handle debris or solid materials present in the wastewater flow? Are there any features or mechanisms in place to
prevent clogging or blockages?6.What safety features are incorporated into the design of the sluice gate to ensure the protection of personnel
and equipment during operation and maintenance activities?7.Can you provide references or case studies where this sluice gate has been
successfully implemented in similar sewage treatment plant applications? What were the challenges faced, and how were they addressed?
8.How does the supplier handle after-sales support, including technical assistance, spare parts availability, and response time for any potential
issues or emergencies?9.Can you provide details on the environmental impact and sustainability aspects of the sluice gate, such as energy
efficiency, use of recyclable materials, or adherence to environmental regulations?For installation purpose : 10. Do you provide any installation
support or assistance, such as on-site supervision or guidance, to ensure that the cast iron sluice gate is installed correctly? What resources or
documentation are available to help the installation process? 11. Are there any specialized tools or equipment required for servicing the sluice
gate? If so, what are they, and are they provided or available from the supplier? 12. Are there any specific instructions or guidelines for aligning
and adjusting the sluice gate to ensure proper operation and sealing? How do you ensure a tight and leak-free closure when the gate is in the
closed position? 13. Are there any specific inspection access points to be considered during the installation?

Questions to be asked from the Supplier Engineer for comprehensive understanding of the Mechanically cleaned coarse screen installation
:1 What level of support can be expected from the supplier in terms of guiding the installation team, providing installation manuals or documentation, or
resolving any installation-related issues that may arise? 2. What level of support do you offer after the installation is complete? How do you address any issues or
challenges that may arise during the initial operation of the mechanically cleaned coarse screen? 3. What are the most common challenges encountered during
the installation of the mechanically cleaned coarse screen? How do you address or mitigate these challenges? 4. What are the recommended procedures and
steps for the start-up and commissioning of the mechanically cleaned coarse screen once the installation is complete? 5. Are there any specific tests or checks
that need to be performed to ensure the screen is functioning optimally? 6. How does the screen interface with control systems or SCADA (Supervisory Control
and Data Acquisition) systems for operation, monitoring, and data logging purposes? 7. What quality assurance measures are implemented during the
installation process to ensure the mechanically cleaned coarse screen is installed correctly and meets the required standards?

Questions to be asked from the Supplier Engineer for comprehensive understanding of the Mechanically cleaned coarse screen operation
and maintenance: 1. What is the availability of spare parts for the mechanically cleaned coarse screen? Are they proprietary parts or easily obtainable from
common suppliers? 2. Do you provide training sessions for the plant operators and maintenance personnel on the operation and maintenance of the
mechanically cleaned coarse screen? What resources or documentation are available to assist with troubleshooting and maintenance tasks? 3. What measures
are taken to optimize the operational efficiency of the mechanically cleaned coarse screen? Are there any features or technologies incorporated to minimize
energy consumption or reduce water loss?
Questions to be asked from the Supplier Engineer for comprehensive understanding of Knife Gate valve -
1. Can you provide specific examples or case studies where your knife gate valves have been successfully used in challenging applications involving highly abrasive
or corrosive fluids, and what were the long-term performance and maintenance requirements in those cases? 2. What measures have been taken to address
potential issues such as gate jamming, seat leakage, or excessive wear in your knife gate valve design? 3.In applications where solids or debris are present in the
fluid, what preventive measures or maintenance procedures are recommended to ensure the knife gate valve continues to operate effectively without
obstruction or damage?4.What kind of technical support and after-sales services do you provide to customers who purchase your knife gate valves? Do you offer
on-site assistance, training, or troubleshooting services in case of any operational issues?
Questions to be asked from the Supplier Engineer for comprehensive understanding of Disc Filter - 1.What is the expected lifespan of the filter
cloth? Are there any factors that can significantly affect its durability, and how can we mitigate them?2.How does the system handle variations in influent quality
and flow rates? Can it handle peak flow conditions without compromising filtration efficiency?3.What measures are in place to prevent clogging or fouling of the
filter discs? Are there any specific pretreatment requirements to ensure optimal filter performance?4.How does the backwashing process work, and what is the
typical frequency and duration of backwashing cycles? Can the backwash be adjusted to accommodate different operating conditions? 5.Can the filter system
effectively handle the removal of not only suspended solids but also other contaminants such as oils, grease, and fine particles? Are there any limitations or
recommended pre-treatment steps for specific contaminants?6.Can the system handle high concentrations of solids during peak loads without experiencing
excessive pressure drops or reduced filtration efficiency? Are there any design features that allow for increased solids loading capacity? 7.Can you provide
references or case studies where your DISC filter technology has been successfully implemented in similar applications? What were the key challenges faced, and
how were they addressed?8.How does the PLC control system optimize filter operation and backwashing cycles? Can it be customized to meet specific process
requirements?9.What is the anticipated energy consumption of the filter system? Are there any energy-saving features or options available to optimize
operational costs?10.What level of technical support and maintenance services do you provide after the installation? Are there any specific training programs
available for operators and maintenance personnel?
Questions to be asked from the Supplier Engineer for comprehensive understanding of GRIT Mechanism 1.Can you provide data or references
demonstrating the long-term performance and efficiency of your GRIT mechanism equipment in terms of grit removal efficiency, energy consumption, and
maintenance requirements? How does it compare to other available technologies in the market?2.How does your equipment handle abrasive grit particles over
time? What measures are in place to prevent excessive wear and damage to the equipment, and what is the expected lifespan of critical components? 3.Could
you explain in detail how your grit classifier system effectively separates and removes grit from the wastewater? What mechanisms or designs ensure the
efficient lifting and separation of grit particles, and how is the reliability of this process maintained? 4.Sewage treatment plants often face challenges related to
odor control. How does your equipment address the issue of odors associated with grit handling and removal? Are there any additional measures or technologies
integrated into the system to minimize odor generaion and emission?5.What preventive maintenance measures are recommended for your GRIT mechanism
equipment, and how often are they typically required? In case of equipment failure or breakdown, what is the estimated downtime for repairs and how does it
affect the overall operation of the sewage treatment plant?6.What kind of training and support do you provide to the operators and maintenance personnel of
the sewage treatment plant using your equipment? Do you offer ongoing technical assistance and troubleshooting services?
Questions to be asked from the Supplier Engineer for comprehensive understanding of Clarifier – 1.Can you provide specific data or case studies
demonstrating the clarifier's performance and efficiency in terms of solids removal and effluent quality? 2.What are the maintenance requirements for the
clarifier equipment? Are there any specific operational considerations or potential challenges we should be aware of? 3. Are spare parts readily available for the
clarifier? What is the typical lead time for replacement parts?