You are on page 1of 8

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09LEK03/ (DB)
HSU-12LEK03/ (DB)
HSU-108CH09 Contents
HSU-138CH09 PARTS AND FUNCTIONS 1
OPERATION 2-4
MAINTENANCE 5
CAUTIONS 6.7
TROUBLE SHOOTING 7

Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010519692
Parts and Functions
Indoor Unit Remote controller
8. TIMER ON display
10 9. CLOCK display
1
6 10. TEMP display
2
 7 11. POWER ON/OFF
5 8 Used for unit start and stop.
9 12. MODE
  3
4
HEALTH ON/OFF Used to select AUTO run, COOL,
23
24 DRYHEAT and FAN operation.
11
 
13
FAN
13. FAN
18 Used to select fan speed LO,
  MODE
MED, HI, AUTO
14. HOUR
 Used to set clock and timer setting.
 SWING 15
15. SWING
 POWER/SOFT

 TIMER
23 Used to set auto fan direction.
 12 20 16. SLEEP
21 CLOCK
14 Used to select sleep mode.
 Inlet  Air
Purifying Filter (inside) 19
LIGHT

SET SLEEP
16 17. LOCK
  Outlet
 Used to lock buttons and LCD display.
 Inlet grille 17 LOCK RESET
22
18. TEMP.SETTING
 Anion generator (inside)
 Used to select your desired temp.
19. SET / LIGHT
 Vertical blade Used to confirm timer and clock
settings.Control the lightening and
adjust left and right air flow extinguishing of the indoor LED
 Power indicator (Lights up when unit starts.) display board.
20. TIMER
 Timer mode indicator Used to select TIMER ON,
(Lights up whenTimer operation is selected.) 1. Mode display
AUTO TIMER OFF,TIMER ON-OFF
 Operation mode indicator COOL 21. CLOCK Used to set correct time
(lights up when the compressor is on.) DRY 22. RESET
Used to reset the controller back
 Remote signal receiver HEAT to normal condition.
(A beeping sound is generated when a signal FAN
2. SWING display 23. HOUR / POWER/SOFT
from remote controller isreceived.) Used to set clock and timer setting.
3. FAN SPEED display
 Ambient temp display Every time the button is pressed,
When receiving the remote control signal, display the set display changes as follows:
AUTO LO MED HI
temperature and in the rest time the room temperature is BLANK
is displayed and this room temperature is only for reference. 4. SLEEP display POWER SOFT
5. LOCK display 24. HEALTH
 Horizontal flap 6. SIGNAL SENDING Used to operate the healthy
adjust up and down air flow Don't adjust it manually 7. TIMER OFF display function and LCD display.
NOTE:
Cooling only unit do not have displays and functions related with heating
Actual inlet grille may vary from the one shown in the If the unit which you purchased has healthy function,follow it.If not,please ignore.
manual according to the product purchased
Loading of the battery
Outdoor Unit
 Remove the battery cover;


 Load the batteries as
illustrated. 2 R-03 batteries,
 resetting key(cylinder);
  Be sure that the loading
is in line with the " + "/"-";
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
 DRAIN HOSE
 Load the battery,then put on the cover again.
Note:
Clock set The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
Press CLOCK button, "AM" or "PM" flashes. When electronic-started type fluorescent lamp or change-over
Press or to set correct time. Each press will increase wireless telephone is installed in the type fluorescent lamp or
or decrease 1min. If the button is kept pressed,time will room, the receiver is apt to be disturbed in receivingthe signals,
change quickly. After time setting is confirmed,press SET, so the distance to the indoor unit should be shorter.
"AM "and "PM" stop flashing,while clock starts working. Full display or unclear display during operation indicates the
POWER/SOFT
batteries have been used up. Please change batteries.
TIMER
If the remote controller can't run normally during operation,
please remove the batteries and reload several minutes later.
CLOCK Hint:
LIGHT Remove the batteries in case unit won't be in usage for a long period.
SET SLEEP If there are any display after taking-out, just need to press reset key

1
Operation
Unit start / stop Auto Operation
Press ON/OFF button, unit starts or stops.
HEALTH ON/OFF
According to the automatic choice
system in temperature in indoors
cold or make the hot movement
FAN
FAN
MODE

Select temp.setting FAN


SWING

MODE

SWING

Operation Remote
Note
Mode Controller
Under the mode of auto operation, air conditioner will
Dry Operation
automatically select Cool or Heat operation according
AUTO
to room temperature. When FAN is set to AUTO, the
air conditioner automatically adjusts the fan speed
according to room temperature.
COOL

In DRY mode, when room temperature becomes


lower than temp.setting+2 oC,unit will run intermittently
DRY at LOW speed regardless of FAN setting.

HEAT
FAN

In FAN operation mode, the unit will not operate in MODE


COOL or HEAT mode but only in FAN mode ,AUTO is
FAN not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available. SWING

Note:
Cool Operation In DRY mode, when room temperature becomes lower than temp.
setting+2oC, unit will run intermittently at LOW speed regardless
of FAN setting.

Fan Operation

FAN 1. When FAN is set to AUTO,


the air conditioner
MODE automatically adjusts HEALTH ON/OFF

the fan speed according AUTO LO MED HI

SWING to roomtemperature.
2.In FAN operation mode FAN

the unit will not operate


MODE
in COOL mode but only
in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.

Heat Operation
Air Flow Direction Adjustm
(1)
FAN

MODE
FAN

MODE
SWING

SWING

Note:
In HEAT mode,warm air will blow out after a short periodof the time
due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts Remote controller can memorize each operation status. When starting it
the fan speed according to room temperature. next time,just press ON/OFF button and unit will run in previous status.
Cooling only unit do not have displays and functions related with heating

2
Operation
HEALTH Operation POWER/SOFT Operation
(This function is unavailable on some models.) (This function is unavailable on some models.)

(1) POWER Operation


HEALTH ON/OFF When you need rapid heating or cooling,
you can use this function.
In COOL mode, fan speed automatically
FAN
POWER/SOFT
takes high speed of AUTO fan mode.
In HEAT mode, fan speed automatically
TIMER

CLOCK

LIGHT
takes medial speed of AUTO fan mode.
SET SLEEP

To cancel POWER operation


Press POWER/SOFT button twice ,POWER/SOFT disappears.
The anion generator in the airconditioner can
generate a lot of anion effectively balance the
quantity of position and anion in the air and (2) SOFT Operation
also to kill bacteria and speed up the dust sediment You can use this function when silence
in the room and finally clean the air in the room. is needed for rest or reading.
In SOFT operation mode, fan speed
POWER/SOFT

TIMER automatically takes low speed of AUTO fan mode.


CLOCK

LIGHT

SET SLEEP

Healthy Negative ions


To cancel SOFT operation
Press POWER/SOFT button again ,POWER/SOFT disappears.

TIMER Operation Emergency operation and test operation


Set Clock correctly before starting Timer operation
You can let unit start or stop automatically a following times: Pi
Emergency Operation:
Before you wake up in the morning, or get back from outside
Use this operation only when the remote controller
or after you fall asleep at night. is defective or lost.
(1) TIMER ON When the emergency operation switch is
pressed,the" Pi "sound is heard once, which means
the start of this operation.
In this operation, the system automatically selects
the operation modes,cooling or fan or heat,according
TIMER
POWER/SOFT

TIMER
POWER/SOFT
to the room temperature.
CLOCK CLOCK Room Operation Designated Timer
Air flow
LIGHT LIGHT
temperature mode temperature mode
SET SLEEP SET SLEEP

ABOVE 23OC COOLING 26OC NO AUTOMATIC


POWER/SOFT
BELOW 23OC HEAT 23OC NO AUTOMATIC
TIMER

CLOCK
(Cooling only uint˅ Operation Designated Timer
Air flow
LIGHT

SET SLEEP
(2) TIMER OFF Room temperature mode temperature mode

BELOW 23OC FAN 26OC NO AUTOMATIC

It is not possible to operate in dry mode.


POWER/SOFT POWER/SOFT

TIMER TIMER

CLOCK CLOCK
LIGHT LIGHT
SET SLEEP SET SLEEP

Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
(3) TIMER ON-OFF o
temperature is below 16 C, do not use it in the
normal operation. Pi Pi
TIMER
POWER/SOFT

TIMER
POWER/SOFT

TIMER
POWER/SOFT

TIMER
POWER/SOFT
Continue to press the test operation
CLOCK

LIGHT

SET SLEEP
CLOCK

LIGHT
SET SLEEP
CLOCK

LIGHT
SET SLEEP
CLOCK

LIGHT

SET SLEEP
switch for more than 5 seconds. After
you hear the "Pi" sound twice,release
your finger from the switch: the cooling
To cancel TIMER mode operation starts with the air flow speed "Hi".
Just press TIMER button several times untilTIMER mode disappears.

3
Operation
Comfortable SLEEP
Before going to bed,you can simply press the SLEEP 2. In HEAT mode
button and unit will operate in SLEEP mode and bring 1 hours after SLEEP mode starts, temp will
become 2OC lower than temp.setting. After
you a sound sleep.
another 1 hours, temp decrease by 2 O C
further. After more another 3 hours, temp.
SLEEP Operation rises by 1O C further. The unit will run for
further 3 hours then stops. Temp. is lower
than temp. setting so that room temperature
TIMER
won't be too high for your sleep.
CLOCK
LIGHT

SET SLEEP Temp.setting Unit stop


1 hr Decreases 2 C
O

1 hr O
Decreases 2 C
3 hrs
3 hrs Rises 1C O

SLEEP SLEEP
operation starts operation stops
In HEAT mode

Operation Mode 3.In AUTO mode


1. In COOL,DRY mode The unit operates in corresponding sleep mode
1 hours after SLEEP mode starts, temp. will corresponding sleep mode adapted to the
become 1OC higher than temp. setting. After automatically selected operation mode.
another 1 hours, temp. rises by 1OC further. 4. In FAN mode
The unit will run for further 6 hours then stops It has no SLEEP function.
Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep. 5. When quiet sleeping function is set to 8 hours
SLEEP operation stops the quiet sleeping time can not be adjusted.When
SLEEP operation starts
Approx.6hrs TIMER function is set,the quiet sleeping function
can't be set up.After the sleeping function is set
1 hr Rises 1 C O up,if user resets TIMER function, the sleeping
function will be cancelled; the machine will be in
1 hr Rises1 CO
the state of timing-on,if the two modes are set up
at the same time,either of their operation time is
Unit stop ended first ,the unit will stop automatically,and
Temp.setting
the other mode will be cancelled.
In COOL, DRY mode

Power Failure Resume Function Note to the power failure resume:


If the unit is started for the first time, the compressor will not press the sleep button ten times in five seconds and enter
start running unless 3 minutes have elapsed. When the power function after hearing four sounds.And press the sleep button
resumes after power failure, the unit will run automatically, ten times within five seconds and leave this function after
and 3 minutes later the compressor starts running. hearing two sounds.

4
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room Remote Controller Indoor Body
Do not block the air inlet
temperature or outlet
Proper
Wipe the air conditioner by using a soft and
temperature
dry cloth.For serious stains,use a neutral
Do not use water wipe the controller with a detergent diluted with water.Wring the water
dry cloth.Do not use glass cleaner or chemical out of the cloth before wiping.then wipe off
cloth. the detergent completely.

Do not use the following for cleaning


Close doors and windows Use the timer effectively
during operation
O O
During cooling operation
prevent the penetration of Gasoline,benzine, thinner or cleanser may Hot water over 40 C(104 F) may cause
direct sunlight with
damage the coating of the unit. discoloring or deformation.
curtain or blind

Air Filter cleaning


Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released
If the unit is not to be used Use the louvers effectively from the stopper, and remove the filter downward.
for a long time, turn off the Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with
power supply main switch. water.After washing, dry the filter completely in the shade.
Attach the filter. Once every
Attach the filter correctly so that the "FRONT" indication is two weeks
facing to the front.Make sure that the filter is completely
OFF fixed behind the stopper.If the right and left filters are not
attached correctly, that may cause defects.
Close the inlet grille.

Replacement of Air Purifying Filter (NOTE: Air purifying filter is optional part)

1.Open the lnlet Grille 4.Attach the standard air filter


Prop up the inlet grille by using a (Necessary installation)
small device named grille-support
which located in the right side of
the indoor unit.

2.Detach the standard air filter ATTENTION:


Slide the knob slightly upward to The white side of the photocatalyst air purifying
release the filter, then withdraw it. filter face outside,and the black side face the unit.
The green side of the bacteria-killing medium air
purifying filter face outside,and the white side face the unit.

Detach old Air Purifying Filter


5.Close the Inlet Grille
Close the Grille surely

NOTE:
The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.
The bacteria-killing medium air purifying filter will be used
3.Attach Air Purifying Filter
Put air purifying filter appliances into the for a long time,no need for replacement. But in the period
right and left filter frames. of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.

Please keep the bacteria-killing medium air purifying filter in


the cool and dry conditions avoid long time directly sunshine
when you stop using it,or its ability of sterilization will be
reduced.

5
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.

WARNING
When abnormality such as burnt-small found, Use an exclusive Check proper
immediately stop the operation button and power source installation of the
contact sales shop. with a circuit drainage securely
breaker

OFF STRICT STRICT


ENFORCEMENT ENFORCEMENT
Connect power supply cord Use the proper voltage 1.Do not use power supply cord extended
to the outlet completely or connected in halfway
2.Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
STRICT STRICT to vapor or oil steam.
ENFORCEMENT ENFORCEMENT PROHIBITION
Do not use power supply Take care not to damage Do not insert objects into the air
cord in a bundle. the power supply cord. inlet or outlet.

PROHIBITION PROHIBITION PROHIBITION

Do not start or stop the Do not channel the air flow directly Do not try to repair or Connect the earth
operation by disconnecting at people, especially at infants or reconstruct by yourself.
the aged. cable.
the power supply cord
and so on.

earthing
PROHIBITION PROHIBITION

CAUTION
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with
food, art work, precise equipment, when gas appliance is running at the wet hand.
breeding, or cultivation. same time.

STRICT
PROHIBITION ENFORCEMENT PROHIBITION
Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit
or other heating apparatus. installation stand for cleaning

PROHIBITION PROHIBITION PROHIBITION


Do not place animals or plants in Do not place any objects on or Do not place flower vase or water
the direct path of the air flow climb on the unit. containers on the top of the unit.

PROHIBITION PROHIBITION PROHIBITION

6
Trouble shooting
Before asking for service, check the following first. Cautions

Phenomenon Cause or check points The machine is adaptive in following situation


The system does not restart When unit is stopped, it won't restart 1.Applicable ambient temperature range:
immediately until 3 minutes have o o
immediately. elapsed to protect the system. For: T1 Maximum: D.B / W.B 32 C/23 C
Indoor o o
When the electric plug is pulled out Minimum: D.B / W.B 18 C/14 C
and reinserted, the protection circuit Cooling o o
will work for 3 minutes to protect the Maximum: D.B 43 C/26 C
Outdoor o
air conditioner. Minimum: D.B 18 C
During unit operation or at stop, o
Maximum: D.B 27 C
a swishing or gurgling noise may Indoor o
Minimum: D.B 15 C
be heard.At first 2-3 minutes after Heating o o
unit start, this noise is more noticeable. Maximum: D.B / W.B 24 C/18 C
Noise is heard
(This noise is generated by Outdoor o o
Minimum: D.B / W.B -7 C/-8 C
refrigerant flowing in the system.)
During unit operation, a cracking For: T3 o o
noise may be heard.This noise is Indoor Maximum: D.B / W.B 29 C/19 C
o o
Normal generated by the casing expanding Minimum: D.B / W.B 18 C/14 C
or shrinking because of Cooling o o
Performance temperature changes. Outdoor Maximum: D.B / W.B 54oC/24 C
inspection Should there be a big noise from Minimum: D.B 18 C
air flow in unit operation, air o
filter may be too dirty. Maximum: D.B 27 C
Indoor o
This is because the system Minimum: D.B 15 C
Smells are generated. circulates smells from the interior Heating o o
Maximum: D.B / W.B 24 C/18 C
air such as the smell of furniture, Outdoor Minimum: D.B / W.B -7oC/-8oC
paint, cigarettes.
Mist or steam are blown out. During COOL or DRY operation, 2. If the supply cord is damaged, it must be replaced by the
indoor unit may blow out mist.
This is due to the sudden cooling manufacturer or its service agent or a similar qualified person.
of indoor air. The type of connecting wire is H05RN-F or H07RN-F
In DRY mode, when room 3. If the fuse on PC board is broken please change it with a fuse
temperature becomeslower
In dry mode, fan than temp.setting+2 oC,unit will type T. 3.15A/250V.
speed can’t be changed. run intermittently at LOW speed If the fuse of outdoor unit on PC board is broken, please change
regardless of FAN setting.
it with the type of T. 25A/250V.
Is power plug inserted?
Is there a power failure?
4.The distance between the indoor unit and the floor should be
Is fuse blownout? more than 2m.
Is the air filter dirty?
5.The wiring method should be in line with the local wiring standard.
Normally it should be cleaned 6. After installation, the power plug should be easily reached..
every 15 days.
Multiple Poor cooling 7.The used batteries should be disposed of properly.
Are there any obstacles before
check inlet and outlet? 8.The appliance is not intended to use by young children or infirm
Is temperature set correctly?
Are there some doors or persons without supervision.
windows left open?
Is there any direct sunlight
9.Young children should be supervised ensure that they do not
through the window during the play with the appliance.
cooling operation?(Use curtain) 10.The appliance must be installed on a strong enough support.
Are there too much heat sources
or too many people in the room 11.The wiring diagram is attached inside the machine.
during cooling operation?

T1: Application temp. range of air conditioner -7oC~43oC.


T3: Application temp. range of air conditioner -7oC~54oC.