SYSTEM RANGE
Size, mm XL XL XL XL
Thickness (THK) 20 20 25 20 20 20 20
Acoustic
Sound Absorption:
Test results according to EN ISO 354. Classification according to EN ISO 11654, and the single value ratings for Noise
Reduction Coefficient, NRC and Sound Absorption Average, SAA according to ASTM C 423.
0.6
0.4
0.2
0.0
THK
αp, Practical sound absorption coefficient
o.d.s. mm αw Sound absorption class
mm
125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz
THK
o.d.s. mm NRC SAA
mm
20 65 0.90 0.89
AC(1.5)
THK
mm
Articulation Class, ASTM E1111, ASTM E1110
20 180
Certificate / Label
French VOC A
Finnish M1 •
Environmental Footprint
Fire safet y
Country Class The glass wool core of the tiles is tested and classified as
Humidit y Resistance
Visual appearance
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance. Gloss < 1.
Cleanabilit y
Accessibilit y
The tiles in size 600x600 and 1200x600 are easliy demountable. The tiles in size 1200x1200 and XL sizes are
Installation
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall
depth of system see quantity specification. The systems are not recommended for small rooms (approximately 2x2 m²).
Ceilings with a large amount of integrations require careful planning, design and installation.
System weight
The weight of the system (including suspension grid) should be approximately 3-4 kg/m².
Mechanical properties
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at
www.ecophon.com.
CE
Ecophon ceiling systems are CE marked according to the European harmonized standard EN13964:2014. CE marked
construction products are covered by a Declaration of Performance (DOP) which enables customers and users to easily
Size, mm
600x600 1200x600
2 Connect T24 Main runner HD, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main 0,9m/m² 0,9m/m²
3 Connect T24 Cross tee, L=1200 mm, installed at 600 mm centres 1,7m/m² 1,7m/m²
7 Connect Adjustable Hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0,7/m² 0,7/m²
8 Connect Hanger Clip (not to be used in swimming hall environments) 0,7/m² 0,7/m²
9 For direct installation: Connect Direct Bracket, installed at 1200 mm centres 0,7/m² 0,7/m²
Δ Min. overall depth of system, with Adjustable hanger: 115 mm, with Direct bracket: 65 mm - -
600x600x20 50 160
1200x600x20 50 160
Нож для подрезки кромки Dg Cut edge with and without support clip Live load/load bearing capacity
Size, mm
1200x1200
1 Focus Dg 0,7/m²
2 Connect T24 Main runner HD, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main runner and 0,9m/m²
wall).
3 Connect T24 Cross tee, L=1200 mm, installed at 1200 mm centres 0,9m/m²
runner
7 Connect Adjustable Hanger, installed at 1200 mm centres (max. distance from wall 600 mm) 0,7/m²
9 For direct installation: Connect Direct Bracket, installed at 1200 mm centres 0,7/m²
Δ Min. overall depth of system, with Adjustable hanger: 115 mm, with Direct bracket: 65 mm -
1200x1200x25 50 160
Cutting tool Dg Joint between two unsupported edges with Live load/load bearing capacity
Edge clip
Size, mm
2 Connect T24 Main runner HD, installed at 600 mm centres 1,7m/m² 1,7m/m² 1,7m/m² 1,7m/m²
5 Connect Support clip Dg20 1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
6 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm) 1,1/m² 1,1/m² 1,1/m² 1,1/m²
8 Connect Angle trim, fixed at 300 mm centres as required as required as required as required
1600x600x20 50 160
1800x600x20 50 160
2000x600x20 50 160
2400x600x20 50 160
Cutting tool Dg Cut edge with and without support clip Live load/load bearing capacity