SEE CONSTRUCTION

NOTES FOR MASONRY


WALL REINFORCEMENTS DOWEL BARS TO
(TYPICAL) MATCH CHB VERT.
FIN. FLR. LVL. BARS
VARIES

300
DOWEL BARS TO (TYP.)
NAT. GRD. LVL.

DOWEL
MATCH CHB VERT.

400
BARS
800
MIN.

Ø10 BOTT. BARS FIN. FLR. LVL.


@ 300 O.C.
250

250
3-Ø10 BOTT. BARS 3-Ø10 BARS (AS SHOWN)

500 400 Ø10 BOTT. BARS @ 300 O.C.

WF1 WF2
TYPICAL CHB FOOTING DETAILS ( WHERE APPLICABLE )