Materials of Construction
[-z
Building a Better
Boiler Feed Pump
Robert Aronen, Boulden International;
Dennis Plaizier and Dave Sinclair, Hydro-Scotford, Inc.
Say goodbye to concerns about pump seizure: By properly applying
composite materials to a troublesome boiler feed water pump, this large
process facility in Alberta can now run one
pump during full-rate operation
with very low vibration and higher efficiency.
he reliability and eficiency impacts of close-clearance
| ‘wear components — wear rings, inter-stage bushings,
throat bushings, and pressure-reducing bushings
have been well documented,
In 1985, Bloch and Geitner cited the Following poten:
tial problems associated with excessive wear ring clearance:
cffciency losses, loss of rotor stability, shaft breakage, driver
overloading, bearing overheating or failure, unequal load
sharing in parallel pump operation, noise and damage typi
cally associated with cavitation, and possible coral pump
destruction (p. 31-36)
‘One application for which the wear components are
particularly importanc is boiler feed water. In the typical
process plant, the boiler Feed water pump is a multistage
horizontally-spit, beoween-bearings design that is heavily
dependant upon the wear components for rotor stabilicy
Material selection is very importane to ensure long-term
reliability in this service.
The value of proper application and installation of
modern composites is demonstrated by che results from a
‘9-seage boiler feed water pump from a large process facility
in Centra Albert
Why Wear Components are
Important
The close clearance wear components in
4 centtifugil pump perform similar func- | #001 ~5.000 in(
tions. They separate high pressure areas | 5.001 ~ 6.000 in(t
within che pump from lower pretext |” 9017.00 int
viaa minimal clearance between aotating | o55 5 oop nq
and stationary member.
Due to the differential pressure across
26 NOVEMBER
=
these components, there is substantial flow from the high
pressure to lower pressure regions of the pump ~ recirew
lation flow. If inadequate clea
components, the rotating and stationary elements could
possibly seize and lead to substantial pump damage (Bloch,
1988),
‘Conversely, as the clearance beeween rotating and sta
nce Ties between wo metal
tionary components increases, the recirculation flow within
the pump increases and efficiency drops (Bloch and Ge
1985). Over time, this will become evident to the pump
‘operators as recitculation flow increases to the point where
the pump can no longer operate at design capacity
What the operators may not notice is that che wear
‘components also contribute substantially to rotor stabilicy
(Lobanoff and Ross, 1992, p. 440-451), Increased clearance
at the weat components can lead to higher vibration, shorter
bearing life, and the pocental for high-energy failure modes
such as shale breakage
Furthermore, recirculation flow atthe first-stage impel
ler eye increases the effective inlet luid temperature, pos
sibly
90.97). The net result is that a pump with increased clear-
ading to cavitation damage (Lobanoff and Ross, p.
ance at the wear components is not as reliable or efficient as
(Gabel oe Ot
27152 mm) | 0.017in(0.43 mm) | 0.008 in(0.20 mum) |
21mm) | 0018 @aemm) | 00m in023 mm) |
Table 1 Typical clearance values for metal and composite wear rings.
PUMPS & SYSTEMS“Thermal Expansion Coefisient(X-Y plane)
“Thermal Expansion C
ent (Z-iretion) to 300°F
Dynan Coetfisiont of Friction (25 fin) 020
Liming PV
Hardness 75
Water Absorption
“Temperature Limit
Table 2. Composite material properties,
4 pump with reduced clearance
The Composite Advantage
Composite materials have advanced ro the degree chat wea
components can now be the source of reliability improve-
ment Modern composite wear mateals duce the risk of
pump secure and can therefore be installed with dighrer clea
fncs than thoge listed inthe API 610 standard for config
pumps be Table 1)
One material that has been widely applied is a com
presion-molded composite of fuoropolymer resin and long
carbon fibers oriented in a directional matrix, This directional
sults in an anisotropic material with different proper
ties in the X-Y plane compared to the Z-axis.
For a typical pump wear component, the X-Y plane is
perpendicular to the axis of rotation. ‘The properties for this
‘material ae shown in Table 2
The overall combination of properties available in modern
composites (sce Table 2) set the stage for rliabilcy improve
rmcnts, The coeicient of thermal expansion, coefficient of ic
tion, and limiting PV (pressute velocity ratio) are all importane
factors to reduce the rsk of material seizure
‘More importantly, these prop
material 10 survive the normal contact that occurs becween
rotating and staionary components without weating out oF
faling prematurely, particularly during process upsets such as
low flow operation, cavitation, or fundry events.
ties are essential for the
Because composite materials reduce the risk of seizure or
damage during normal contact, running clearance at the wear
‘components can be reduced, typically vo 50 percent ofthe APL
‘components. Reduced
clearance improves eliability and efficiency, as demonstrated
both under controlled conditions and during field studies
(Komin, 1990: Pledger 2001),
Ina recent study of 61 pumps in an oil refinery; conversion
610 recommended value for metal we
to composite wear materials with reduced clearance reduced
the failure rate by 45 percent, and overall vibration levels fll
by an average of 25 percent (Aronen, Boulden, Russek, 2007).
With this growing history of suecess, no wonder pump users
are eurning to composite materials for some of theit roughest
applications
POWPS & SYSTENS
1.8 X 10° inin*F
180 X 10° iin’
155,000 Rimin
0 Shore D
S00°F @6rO)
‘ww pumpzane com
Figure 1. The 9-stage boiler feed water pump.
The Pump that Couldn't
large process facility in Central Alberta was having problems
with their boiler feed pumps. The original 12 chrome metal
‘wear components caused several pump seizutes. Even though
the mecal components were designed with differential hardness,
the original design clearance of 0.016-in (0,406-mm) between
rotating and stationaty wear components was increased to pre
vent seizure. The increased clearance led to production prob-
Jems. When running a fll rates, the plant needed to run to
pumps in parallel
Plant reliability and maintenance personnel needed a
solution thar would allow one pump to meet production
needs during full rate operation without increasing the risk of
scinure. After consultation with eheit local repair facility, ehey
decided to overhaul one of heir pumps using all composite
stationary wear components (case wear rings, in
bushings, throat bushings, and center-stage bushing) wich
reduced clearances.
The pump involved is a common design for a process
rage case
plane boiler feed water pump: 9.stage, horizontally-spit
berween-beatings design (se Figure 1)
This design includes a doublesuetion first-stage impeller
with wear eings, an eyeside wear ring and inter-stage bush
ing ac each of the other cight stages, ro throat bushings, and
a pressure reducing bushing between the Sth and 9th stages
The impellers are 9.125-in (232-mm) diameter, with 5-in
Figure 2 Rotor configuration.
NOVEMBER 200727Is of Construction
mm) diameter wear rings.
are aro This pump des
Section Pressure | 26 psig (182 KPa)
pig (7936 KPa)
“Temperature
Discharge Pressure | 1
Rated Power [317 hp @37kW)
Speed 38501
long, thin shaft (se Fi
the wear rings for rotor stabiliy
While the pump is idl
sn ereates unique challenges which are particulary suited
to the application of composite wear components, The rotor configuration ~ a
re 2) suspended berween bearings ~ relies heavily upon
there is substantial rotor sag (about 0.008-
‘a ______|_—_in/,2-mm) at the center bushing. The rotor sag goes away only when the
Table 3. Process conditions for boiler feed pump.
DICKOW
Pump Company
Dictow Pump Company has mantactored centtags! pumps
‘or mre tan 5 years, aways wih an emphasis 0 precision
Inge in sevice and htralicaMciancy Today we ater
the brandes and most technological advanced range of magnet
taive pumps, 0d have sod npn expenance
Erg
Ded
Heron Cantal Pe
“Clee Cale win cantare
800-880-4442
Dickow Pump Company
a
1738 SANDS PLACE SE» MARIETTA. GA 30067 USA
"TEL: (770) 952-7903 » FAX (770) 933-8846
EMAIL. salex@dickow.com
28 wovEMBER
www.dickow.com [ay|
pump is running and hydrodynamic
forces at the wear rings are established.
During alignment of the pump to the
driver, slow-roll (if coupled to a steam
turbine driver), or at start-up, there will
be contact at the center stage bushing.
and other wear components.
During full speed operation off de-
sign conditions like low-flow operation,
dry-tunnin
‘contact between rotating and stationary
‘components, potentially leading to s
sure. The service conditions, shown in
Table 3, were typical for a process plant
boiler feed pump.
Pump Retrofit Details
To optimize the performance of this
pump during the available repair time
the repair facil selected a composite
material forall of the stationary. wear
components. The existing. 12 percent
clarome meal rotating components were
used in combination with the compos-
J. Running clearance between
rotating and stationary components was
reduced t0 0.008-in (0.203-mm), 50
percent of the original design values,
Instead of fabricating new compo-
rents with complex geometry for the
stationary composite components, the
‘existing components were used as hold
crs for composite “inserts.” The existing
metal bores were increased, and thin-
radial-wall composite inserts were mi
ufactured and pressed into the metal
holders
Additional design detail was needed
for the split int
shown in Figure 3. Usin
age bushings, as
the existing
‘components as “holders” for the com:
posite reduced the required machining
nating the nced for milling
slots and other details on the outside
diameter of the components
To prevent axial movement of the
PUMPS & SYSTEMSFigure 4. Line
‘boring the »
r
TIME FORA | ia
NEW PUMP A oe
Figute 3. Composite insert in metal case ne
ring holder. pera
composite, the metal holders incorpo: Re-engineered
rated a small shoulder on the low pres Pump Saves Money.
sue side, There were no pins or stews CC
‘composite relying upon a heavy inter La
low coefficient of friction and other
properties that reduce risk of seizure
this method of installation b
s proven,
clfeccve wih this composite during the
past rn years of field experience.
Turning the Rotor
Retrofitting a pump with composites
is a fairly straightforward proposition
However, as the clearance at the wear
components decreases rotor concenitic ts keeping your timed screw pump alive costing too much?
ity becomes more important. To ensure Call Leistritz.
success with the new; tighter clearance
We'll select a standard Leistritz pump cartridge that best meets
the repair facility must pay attention to ie eee rey
2 few fundamental details Dt eee eae a
Before the rotor is installed, the eee tai rar
pump should be fully inspected. The
split-line should be checked to
re ea cand
is true, the line bore and seal chamber Were Hest 2k Te SG
bore should be checked for concentric Bree nue Ra
ity (sce Figure 4), and the rotating ele
‘ment shouild have limited run-out (typi
cally 0.002-in mas}
Indiv
checked for condition and concentric
ity, For example, if using the exis
dual components should be
case ring as a holder for a composite
insert, the metal ring should fit prop.
ely within the pump case, Loose or disw "Materials of Construction
Composite wear materials reduce the bo boyaeelnee be repaired
risk of pump seizure and can be installed Once the rotor is in place, the case
a . bolted rogether, and the bearing hous-
with tighter clearances than those listed ings doweled and bolted in place, one
. final check is needed. ‘The rotor should
in the API 610 standard. turn freely, which requires a reasonable
understanding of the pump internals.
Due to the aforementioned rotor
sag (along with friction from the
API 685 1st Edition ene ees
Canned Motor Pumps | 32% cupres Hews:
which would indicate mechanical incer-
Fully compliant with API 685 standards, vertical and
hotonline Caned hotorPumgs ene ference berween rating and stationary
fom Nikiso Furps Amarica, gt se, ~~ E===~| parts. Once the ror is curning acom-
sre eee Beene repair faci will be capable of
Seremarson determining whether the rotor i turn
ing freely or is inhibiced by mechanical
inerference, which could cause prema-
cure failure of the pump.
Results of Retrofit
TThe boiler feed water pump in Alberta
has been running since June 2007 and
the retrofit has delivered everything
plane personnel waneed
+ One pump now meets full load pro-
duction demands
+ Risk of metal ro metal seizure is
dramatically reduced.
+ The pump is running with very
low vibration compared to previous
level,
As an added bonus, amperage
draw on the motor has fillen by 5 per-
cent, Using the rated power of 317-hp
(237-4W) and assuming a power cost
of $0,06/Wh (a typical price in North
“America cis is worth a lot of money
For this’ one pump, the plane will
save roughly $6,200 for every year of
Highly reliable Canned Motor Pumps in ‘operation.
amazingly compact designs.
world’s m
Bearing Mos
Conclusions
The benefits of running a pump with
”
NIKKISO reduced clearance at the wear rings and
~ NIKKISO Pumps America, In similarcomponentsarewell documented
500 Kenrick Drive, Sule C-1 » Houston, TX 77060 by Bld studies and pump design texts
P: 281-310-6747 + F: 281-310-6771 ‘Composite materials allow pump repair
www. nikkisopumpeamerica.com facilities to reduce the clearance at the
Canned Motor Pumps + Metering Pumps « Power Pumps
30 NOVEMBER 2007 ‘wenwpump-zone.com PUMPS & SYSTEMSswear components to values substantially
less than the recommended minimums
for metal components as listed in API
610,
Furthermore, the latest generation
composites ha
‘material properties
which
process upsets, and off-design
he rsk of pump failure
p overhaul practices
a stand up &
n opera
tion, reducing
Quality
help deliver the full benefit of compos.
ite materials with reduced clearance
Thorough component inspection, veri
fication of rotor concentricity within
the case, and proper composite installa
tion methods contributed to the success
of cis application,
1. Arann R., Bou
Band Rash, M
sibility Forward
Tutor
Unive Callege Staion,
9
Tit techinry Ua
Publishing Compan
2, 2001 “Improving Pa
Robert Aronen isthe managing director of Boulden International, Brussels, Belgium,
+32-498-56-20-53, robert @bouldencompanycom, ww: bouldencompany.com.
Dave Sinclair is the general manager and Dennis Plaizier is the sales manager at
Hydro-Scorfrd, Ine, Range Road 215, Highway 15, Bax 3298, Fort Saskatchewan,
Alberta TSL2T3, 780-992-0100, Fax: 780-992-0200, diinclair@hyaroscoford.
com, dplaiier@hydvocoford com, wwu:hydroscotford.com
Simsite’ Bearings
Increase Bearing Life!
Reduce Downtime!
Simsite’ Composite Bearings
* ABS Approved * US Navy Approved
Use the BEST!
4-800-746-7303 _www.Simsite.com
‘Sims Pump Go,, 1314 Park Ave, Hoboken, NJ. 07030