Professional Documents
Culture Documents
Japan Asia-Pacific
MSC Software Japan Ltd. MSC Software (S) Pte. Ltd.
Shinjuku First West 8F 100 Beach Road
23-7 Nishi Shinjuku #16-05 Shaw Tower
1-Chome, Shinjuku-Ku Singapore 189702
Tokyo 160-0023, JAPAN Telephone: 65-6272-0082
Telephone: (81) (3)-6911-1200 Email: APAC.Contact@mscsoftware.com
Email: MSCJ.Market@mscsoftware.com
Worldwide Web
www.mscsoftware.com
Support
http://www.mscsoftware.com/Contents/Services/Technical-Support/Contact-Technical-Support.aspx
Disclaimer
This documentation, as well as the software described in it, is furnished under license and may be used only in accordance with the
terms of such license.
MSC Software Corporation reserves the right to make changes in specifications and other information contained in this document
without prior notice.
The concepts, methods, and examples presented in this text are for illustrative and educational purposes only, and are not intended
to be exhaustive or to apply to any particular engineering problem or design. MSC Software Corporation assumes no liability or
responsibility to any person or company for direct or indirect damages resulting from the use of any information contained herein.
User Documentation: Copyright © 2020 MSC Software Corporation. Printed in U.S.A. All Rights Reserved.
This notice shall be marked on any reproduction of this documentation, in whole or in part. Any reproduction or distribution of this
document, in whole or in part, without the prior written consent of MSC Software Corporation is prohibited.
This software may contain certain third-party software that is protected by copyright and licensed from MSC Software suppliers.
Additional terms and conditions and/or notices may apply for certain third party software. Such additional third party software terms
and conditions and/or notices may be set forth in documentation and/or at http://www.mscsoftware.com/thirdpartysoftware (or successor
website designated by MSC from time to time). Portions of this software are owned by Siemens Product Lifecycle Management, Inc.
© Copyright 2020
The MSC Software logo, MSC, MSC Adams, MD Adams, and Adams are trademarks or registered trademarks of MSC Software
Corporation in the United States and/or other countries. Hexagon and the Hexagon logo are trademarks or registered trademarks of
Hexagon AB and/or its subsidiaries. FLEXlm and FlexNet Publisher are trademarks or registered trademarks of Flexera Software.
Parasolid is a registered trademark of Siemens Product Lifecycle Management, Inc. All other trademarks are the property of their
respective owners.
ADAM:V2020:Z:Z:Z:DC-VIB
Documentation Feedback
At MSC Software, we strive to produce the highest quality documentation and welcome your feedback.
If you have comments or suggestions about our documentation, write to us at: documentation-
feedback@mscsoftware.com.
Please include the following information with your feedback:
Document name
Release/Version number
Chapter/Section name
Topic title (for Online Help)
Brief description of the content (for example, incomplete/incorrect information, grammatical
errors, information that requires clarification or more details and so on).
Your suggestions for correcting/improving documentation
You may also provide your feedback about MSC Software documentation by taking a short 5-minute
survey at: http://msc-documentation.questionpro.com.
Note: The above mentioned e-mail address is only for providing documentation specific
feedback. If you have any technical problems, issues, or queries, please contact Technical
Support.
Welcome to Adams Vibration
poorly designed automobiles can have annoying noises that are due to vibrations of certain components.
Some companies have design guidelines that indicate acceptable ranges of vibration frequencies.
Adams Vibration output data can be used in noise/vibration/harshness (NVH) studies to predict the impact
of vibration on the rider's experience in an automobile, train, plane, and so on.
FD Dampers
When you are given experimentally measured component force magnitude and phase data in the frequency
domain, you can use a frequency-dependent (FD) element to represent it in an Adams simulation. Using an
FD identification tool, you can compute FD coefficients to best fit the measured data. There are four
different forms of FD components:
Pfeffer Linear
Simple FD
Simple FD Bushing
General
The Pfeffer model has a specific representation (see Reference 2 below).
Once you create and verify an FD modeling element in Adams Vibration, you can use it in a time-domain
analysis.
References:
1. Knowledge Base Article 12294: AVB-013: Frequency Dependent (FD) Modeling Elements
(http://simcompanion.mscsoftware.com/KB8016149).
2. Pfeffer, P. and Hofer, K. Simple non-linear model for elastomer and hydro mountings, ATZ Worldwide,
104, 5/2002, May, 2002, 5-7, ISSN: 000 12785.
To delete an FD damper:
1. From the Vibration menu, point to Build, point to FD Damper or FD 3D Damper, and then select
Delete.
2. From the Database Navigator, select the FD damper you want to delete.
3. Select OK.
Input Channels
Input channels provide a port into your system so you can plot the frequency response or drive your system
with an input force using a vibration actuator. You must create an input function to vibrate your system. A
vibration actuator applies an input force to vibrate the system. A vibration actuator can contain expressions
8 Adams Vibration
Building Your Model
that let you use both time and frequency inputs. Each input channel must reference only one vibration
actuator. Each vibration actuator, however, can be associated with multiple input channels.
Output Channels
Output channels provide ports in your system at which you examine the frequency response of the system.
You can think of output channels as instrumentation ports where you can measure system response and report
the results directly in the frequency domain. Output channels can be any valid Adams Solver run-time
function, but are typically displacements, velocities, or accelerations.
Note: Measures are not fully supported. To avoid syntactical warnings or errors, be sure to
enter the run-time function directly.
3. Select OK.
4. Select OK.
Vibration Actuators
Vibration actuators are an Adams Vibration function definition, such as a periodic sine curve, a step, or a
spline curve, used to drive an input channel during a forced vibration analysis. The different types are:
Power Spectral Density
Rotating Mass
Swept Sine
User-Defined Function
Note: You cannot combine vibration actuators of the non-PSD-type with PSD-type vibration
actuators in the same vibration analysis.
Rotating Mass
A rotating mass applies a frequency-dependent force. This actuator represents the force due to a rotating mass
located at a specified radial offset (distance perpendicular to the axis of rotation). The axis of rotation is
defined by the input channel to which this vibrational actuator is applied.
2
f(ω) = m ⋅ ω ⋅ r
where:
ω is the frequency
f ( ω ) is the unbalanced mass forcing function
m is the unbalanced mass
r is the radial offset of the unbalanced mass from the axis of rotation
11
Building Your Model
Similarly, a rotating mass placed at a distance offset normal to the plane (distance along the axis of rotation)
results in an unbalanced moment.
2
t(ω) = m ⋅ ω ⋅ r ⋅ d
where:
Example
1. Assume one mass (green) in the figure. The leading Force Direction represents the direction of
2
centrifugal force ( mr ω ) and points perpendicularly from the axis of rotation to the mass (y-axis in
figure). Radial Offset is the perpendicular distance from the axis of rotation to the mass.
2. The lagging Force Direction axis points perpendicularly from the axis of rotation to where the mass
will be after 90 degrees of rotation (z-axis in figure). Thus it determines the direction of rotation.
3. The leading moment is the moment created by centrifugal force. The Torque Axis is the moment
vector created by centrifugal force (z axis in figure). If it is a negative axis, use -d/2 for the "Offset
Normal to Plane" or create another marker with an axis pointing in the opposite direction. If a second
mass is present as shown (brown), the entered mass value will be the same but the "Offset Normal to
Plane" will be twice what you would enter for the single mass case.
The lagging Torque Axis is where the moment vector will point after 90 degrees of rotation (-y axis in the
figure). If it is a negative axis, use -d/2 for the "Offset Normal to Plane" or create an-other marker with an
axis pointing in the opposite direction. If a second mass is present as shown (brown), the entered mass value
will be the same but the "Offset Normal to Plane" will be twice what you would enter for the single mass case.
Swept Sine
Swept sine defines a constant amplitude sine function being applied to the model. The amplitude of the sine
function and the starting phase angle are required and must be specified in the Create Vibration Actuator
dialog box.
f ( ω ) = F • [ cos ( θ ) + j • sin ( θ ) ]
13
Building Your Model
where:
f is the forcing function
F is the magnitude of the force
θ is the phase angle
ω is the frequency
User-Defined Function
You can define any function of the independent variable omega:
f(ω) = g(ω)
where:
ω is the frequency
g ( ω ) is the general function of omega
Note: When the function is evaluated, omega is populated with each frequency from the vibration
analysis.
Note: YourModel is the name of the model from which you want the objects deleted.
retain_fd_dampers defines whether or not FD damper elements will remain in the model.
If set to no, they are deleted. If set to yes, FD damper elements will remain, but all other
vibration entities, such as input or output channels, will be removed.
14 Adams Vibration
Building Your Model
Testing Your Model
Analyses and Scripts
Note: You cannot combine vibration actuators of the non-PSD-type with PSD-type vibration
actuators in the same vibration analysis.
Frequency Response
Modal Coordinates
Power Spectral Density (PSD)
Transfer Function
Frequency Response
The frequency response of a given output channel is the magnitude and phase response produced by a given
input channel, for each specified frequency.
For frequency response computation, the linearized model is represented as:
sx(s) = A x(s) + B u(s)
y(s) = C x(s) + D u(s)
where:
s is the Laplace variable
A, B, C, and D are state matrices for the linearized model. These matrices are computed by Adams.
x(s) is Laplace transform of the linearization states.
u(s) and y(s) are the Laplace transforms of the inputs and output channels.
The system transfer function can be represented as:
y(s)
H ( s ) = ---------- = C ( sI – A ) – 1 B + D
u(s)
where:
H(s) is the transfer function for the model
I is the identity matrix of dimension equal to the number of system states
For a given vibration analysis, the system frequency response is given as:
y ( s ) = H ( s )u ( s )
Testing Your Model 17
Analyses and Scripts
Modal Coordinates
Modal coordinates are states in the frequency domain solution associated with a specific mode. Modes most
active in a frequency response can be identified from the modal coordinates. The modal coordinates are
computed as:
x ( s ) = ( sI – A ) – 1 Bu ( s )
p ( s ) = H∗ ( s ) ⋅ U ( s ) ⋅ H ( s )
where:
p(s) is the matrix of power spectral density
H*(s) is the complex conjugate transpose of H(s)
U(s) is the matrix of input spectral density
The matrix of input spectral densities is a diagonal matrix with the vibration actuator PSDs on the diagonal
locations. Off-diagonal locations of this matrix are populated with cross-correlation PSD specification.
For example, for a model with two input channels with actuators of type PSD:
U 1 ( s ) U 12 ( s )
U(s) =
U 21 ( s ) U 2 ( s )
where:
U1(s) is the PSD of input channel 1
U2(s) is the PSD of input channel 2
U12(s) is the cross correlation PSD of input channel 1 to input channel 2
U21(s) is U12(s)
Transfer Function
Transfer function is a basic property of a model, and is computed as the magnitude and phase response at a
given output channel for a given input channel with a unit swept sine vibration actuator.
For frequency response computation, the linearized model is represented as:
sx(s) = A x(s) + B u(s)
y(s) = C x(s) + D u(s)
18 Adams Vibration
Analyses and Scripts
where:
s is the Laplace variable
A, B, C and D are state matrices for the linearized model
The system transfer function can be represented as:
y(s)
H ( s ) = ---------- = C ( sI – A ) – 1 B + D
u(s)
where:
H(s) is the transfer function for the model
I is the identity matrix of dimension equal to the number of system states
Python Examples
Your installation directory contains many examples that use Python scripts to perform various Adams
Vibration activities. The following table lists the location and description of each example.
20 Adams Vibration
Classes
Note: All example directories are located in install_dir/vibration/examples, where install_dir is the
directory where Adams is installed.
Classes
Actuator
Modules
msc.Adams.Vibration.libAvAPIc os struct types
libsip re sys
math string traceback
Functions
Actuator(self, ActInfo)
Testing Your Model 21
Classes
AvActuator
This the entry point for the Actuators
Modules
msc.Adams.Vibration.libAvAPIc os struct types
libsip re sys
Classes
AvActuator
AvActuatorPSDFunction
AvActuatorRotatingMass
AvActuatorSweptSine
AvActuatorUserFunction
class AvActuator
class AvActuatorPSDFunction(AvActuator)
class AvActuatorRotatingMass(AvActuator)
class AvActuatorSweptSine(AvActuator)
Methods defined here:
Actuator(self)
WritePy(self, oFile, space)
WriteXML(self, oFile, space)
Swept sine
__init__(self, Name, Type, Mag, Phase)
Testing Your Model 23
Classes
class AvActuatorUserFunction(AvActuator)
AvAMD
From Adams Vibration.AvAMD import *
Constructor:
AvAMD(fName)
Constructor
Returns: object
Parameters:
string fName: Name of the adm file with the Adams Solver model
in it
24 Adams Vibration
Classes
Adams_OBJECT Model()
Get the key to the model
Returns: int - the key to the model
Parameters: None
Adams_OBJECT Ground()
Get the key to the ground object
Returns: int - the key to ground
Parameters: None
int AdamsID(Object)
Get the objects Adams ID
Returns: int - the id assigned to the object
Parameters:
Object - Adams_OBJECT database object to get the id from
Adams_OBJECT CreateVariable(func)
Create a solver variable in the database
Returns: int - the key to the variable
Parameters:
func - string solver function
list PartList()
Get a list of parts in the model
Returns: list - list of keys
Parameters: None
list MarkerList(part)
Get a list of markers for the given part
Returns: list - list of markers
Parameters:
part - Adams_OBJECT part to get the markers from
list StateMatrixList(results)
Get a list of state matrix objects for the given results object
Returns: list - list of state matrix
Parameters:
results - Adams_OBJECT results object to get the state
matrix from
Adams_OBJECT PartFromMarker(markerID)
Get the markers parent
Returns: Adams_OBJECT - key of the parent part
Parameters:
markerID - int Adams ID of the marker
string ObjName(dbObject)
Get the name of the database object
Returns: string - Name of the object
Parameters:
dbObject - Adams_OBJECT database object to get name from
string MarkerName(markerID)
Get the name of the marker
Returns: string - Name of the marker
Parameters:
markerID - int Adams ID of the marker
Adams_OBJECT CreateResults()
Create a results object in the database
Returns: Adams_OBJECT - key to the results object
Parameters: None
bool WriteADM(fName)
Write the model to a solver database file
Returns: bool - true for success
Parameters:
fName - string name of the adm file to write
Adams_OBJECT CreatePInput(varIDs)
Create a plant input object in the database
Returns: Adams_OBJECT - key to the plant input object
Parameters:
varIDs - list of Adams ID's of the solver variables for
the plant input
int DiffID()
Get the Adams ID to assign to the next DIFF
Returns: int - Adams ID of the DIFF
Parameters: None
Adams_OBJECT CreateResultsVariable(analysisObject,
variableName,comment1, comment2, data)
Create a results variable
Returns: Adams_OBJECT - key of the variable
Parameters:
analysisObject - Adams_OBJECT key of the analysis
variableName - string name of the new variable
comment1 - string variable comment
comment2 - string variable comment
data - list values to assign to variable
double StateMatrixTime(smObject)
Get the time from a state matrix object
Returns: double - simulation time the state matrix object was
created
Parameters:
smObject - Adams_OBJECT key to the state matrix object
bool StateMatrixABCD(smObject)
Determine if a state matrix object has B, C, D matrix
Returns: Boolean - true if B, C, and D exist false otherwise
Parameters:
smObject - Adams_OBJECT key to the state matrix object
<![endif]>int NodeID(Marker)
list ReferenceList(Object)
Get a list of objects that reference the given object
Returns: list - list of objects
Parameters:
Object - Adams_OBJECT to get the references from
list MKCList(results)
Get a list of MKC objects for the given results object
Returns: list - list of MKC objects
Parameters:
results - Adams_OBJECT results object to get the MKC from
list FlexList()
Get a list of parts in the model
Returns: list - list of keys
Parameters: None
Adams_OBJECT Marker(Id)
Get a marker key given the id
Returns: Adams_OBJECT
Parameters:
Id - Adams id of the marker
Parameters:
Fixed - key to the fixed joint
IorJ - character 'I' marker or 'J' marker
void Delete(k_obj)
Delete an object from the database
Returns: None
Parameters:
k_obj - key to the object to be removed
char* UnitString(unit)
Get the unit string for the given unit
30 Adams Vibration
Classes
string ufunc - name of the user function must be in the global dictionary
complex ufunc(data , w)
Returns:complex f(w) actuator value at w
Parameters:
Testing Your Model 33
Classes
Returns: bool True if the given input channel has a cross correlation actuator False
otherwise
Parameters:
int iic input channel index.
If iic is less than zero the function returns True if any input channel has a cross
correlation actuator.
AvAPI_Complex Class
Constructors:
AvAPI_Complex(void)
AvAPI_Complex default Constructor
Returns: Object pointer real and imaginary set to zero
Parameters: None
AvAPI_Complex(r, i)
AvAPI_Complex Constructor
Returns: Object pointer
Parameters:
double r - real part
double i - imaginary part
Public Methods:
AvAPI_Complex& byMP(magnitude, theta)
Set real and imag parts using the magnitude and phase given
Returns:AvAPI_Complex& - reference to this object
Parameters:
double magnitude - magnitude of the complex value
double theta - phase angle in degrees
Note: real = magnitude * cos(theta)
imag = magnitude * sin(theta)
double real(void)
Return the real part of the complex number
Returns: double - real part
Parameters: None -
double imag(void)
Return the imaginary part of the complex number
Returns: double - imag part
Testing Your Model 35
Classes
Parameters:None -
double Mag(void)
Return the magnitude of the complex number
Returns: double - magnitude
Parameters: None -
double Phase(void)
Return the phase of the complex number
Returns: double - phase angle in degrees
Parameters: None -
AvAPI_Matrix Class
Constructors:
AvAPI_Matrix(nRow, vals)
Vector Constructor
Returns:Object
Parameters:
intnRow- Number of rows of data
list of double or complex vals - Data values column wise
Dense 3D Constructor
Returns:Object pointer
Parameters:
int nSlot- Number of slots of data
int nRow- Number of rows of data
int nCol - Number of columns of data
list of double or complex vals - Data values slot wise column wise
Methods:
double Value(row)
Value at location [row,0]
Returns:double- Value of the matrix location[row,0]
Parameters:int row- Row number
double Value(row, col)
Value at location [row, col]
Returns:double- Value of the matrix location[row,col]
Parameters:
int row- Row number
int col - Column number
double Value(slot, row, col)
Value at location [row, col] for matrix at the specified slot number
Returns:double- Value of the matrix location [row,col] ] for matrix at specified slot number
Parameters:
int slot- Slot number
int row- Row number
int col - Column number
AvAPI_Complex ValueC(row, col)
Value at location [row, col]
Returns:AvAPI_Complex- Value of the matrix location[row,col]
Parameters:
int row- Row number
int col - Column number
AvAPI_Complex ValueC(slot, row, col)
Value at location
Testing Your Model 37
Classes
int Size(dim)
Matrix dimension
Returns: int - size of the matrix int the given dimension
Parameters:
int dim- Dimension to get the size 0, 1, or 2
list MultMv(vector)
Multiply the vector by the matrix
Returns: list - output vector
Parameters:
list vector- List of double or complex values
AvAPI_System Class
Constructor:
AvAPI_System(Time, A, B, C, D, actuatorList, modeList)
Constructor for a license system
Returns:Object pointer
Parameters:
double Time - Simulation time of linearization
AvAPI_Matrix A - system A matrix from Adams
AvAPI_Matrix B - system B matrix from Adams
AvAPI_Matrix C - system C matrix from Adams
AvAPI_Matrix D - system D matrix from Adams
list actuatorList - list of actuators
list modeList - list of modes by index to use in system calculations; NULL for including all
modes.
Public Methods:
AvAPI_ActuatorActuator (iIC)
Actuator
Returns:AvAPI_Actuatoractuator for given input channel
38 Adams Vibration
Classes
AvAPI_MatrixFrequencyResponse (Omega)
Frequency Response
Returns:AvAPI_Matrix- system frequency response3D complex matrix of the number
of output channels times the number of input channels times the number of frequencies
Parameters: AvAPI_Matrix Omega vector of frequencies
AvAPI_Matrix MCT (Omega, scaleMCT)
modal coordinate table
Returns:AvAPI_Matrix- modal coordinate table
Parameters:
AvAPI_Matrix Omega vector of frequencies
bool scaleMCT- ifTrue MCT matrix is scaled by the input actuators
AvAPI_Matrix MPF (iic, iOC, iFr, iMd, Omega)
modal participation factors
Returns:AvAPI_Matrix- system modal participation factors
Parameters:
int iic - input channel index
int IOC - output channel index
int iFr - frequency index
int imd - mode number
AvAPI_Matrix Omega vector of frequencies
AvAPI_Complex PSD (IOC, frequency)
Compute power spectral density (PSD)
Returns: AvAPI_Complex PSD value
Parameters:
int IOC - input channel index
double frequency - frequency for evaluation
AvAPI_Matrix PSD (frequency)
Compute power spectral density (PSD)
Returns:AvAPI - Computed PSD values
Parameters:
double frequency - frequency for evaluation
double Time()
Get the time of linearization
Returns:double Time given
40 Adams Vibration
Classes
Parameters: None
AvAPI_Matrix ModalMatrix (Which)
Get A,B,C, or D Matrix
Returns:AvAPI_Matrix Matrix
Parameters:
char Which - Matrix to get A B C D
AvAPI_SystemSS Class
Constructor:
AvAPI_SystemSS(Time, A, B, C, D, actuatorList)
Constructor for a state space linear system
Returns: Object
Parameters:
double Time - Simulation time of linearization
AvAPI_Matrix A - system A matrix from Adams AvAPI_Matrix
B - system B matrix from Adams
AvAPI_Matrix C - system C matrix from Adams
AvAPI_Matrix D - system D matrix from Adams
list actuatorList - list of actuators
Public Methods:
double Time()
Get the time of linearization
Returns:double Time given
Parameters: None
AvAPI_Actuator Actuator(iIC)
Actuator
Returns:AvAPI_Actuator actuator for given input channel
Parameters:int iicindex of the input channel
int Inputs (void)
Inputs
Returns: int - number of system inputs
Parameters: None
int Outputs (void)
Outputs
Returns: int - number of system outputs
Testing Your Model 41
Classes
Parameters: None
AvAPI_Matrix TransferFunction(Omega)
Transfer Function
Returns:AvAPI_Matrix - system transfer function3D complex matrix of the number
of output channels times the number of input channels times the number of frequencies
Parameters: AvAPI_Matrix Omega vector of frequencies
AvAPI_Matrix FrequencyResponse (Omega)
Frequency Response
Returns: AvAPI_Matrix - system frequency response3D complex matrix of the
number of output channels times the number of input channels times the number of frequencies
Parameters: AvAPI_Matrix Omega vector of frequencies
AvAPI_Matrix MCT (Omega, scaleMCT)
modal coordinate table
Returns: AvAPI_Matrix - modal coordinate table
Parameters:
AvAPI_MatrixOmega vector of frequencies
bool scaleMCT - ifTrue MCT matrix is scaled by the input actuators
AvAPI_Matrix MPF (iic, iOC, iFr, iMd, Omega)
modal participation factors
Returns: AvAPI_Matrix - system modal participation factors
Parameters:
int iic - input channel index
int IOC - output channel index
int iFr - frequency index
int imd - mode number
AvAPI_Matrix Omega vector of frequencies
AvAPI_Complex PSD (IOC, frequency)
Compute power spectral density (PSD)
Returns: AvAPI_Complex PSD value
Parameters:
int IOC - input channel index
double frequency - frequency for evaluation
AvAPI_Matrix PSD (frequency)
Compute power spectral density (PSD)
Returns:AvAPI_Matrix PSD values
42 Adams Vibration
Classes
Parameters:
double frequency - frequency for evaluation
AvAPI_Matrix ModalMatrix (Which)
Get A,B,C, or D Matrix
Returns:AvAPI_Matrix Matrix
Parameters:
char Which - Matrix to get A B C D
AvAPI_Matrix ComplianceMatrix ()
Compute the compliance matrix
Returns:AvAPI_Matrix Compliance Matrix
Parameters: None
AvAPI_ToolBox
From msc.Adams.Vibration.AvAPI import *
Data Members:
AvAPI_ToolBox.eRECTANGULAR
AvAPI_ToolBox.eHAMMING,
AvAPI_ToolBox.eHANNING,
AvAPI_ToolBox.ePARZEN,
AvAPI_ToolBox.eWELCH
Methods defined here:
double Frequency(i, nFFT, dt, HZ)
return the frequency associated with the ith point of the FFT
Returns: double
Parameters:int i - point number
int nFFT - total number of points in FFT
double DT - point spacing
bool HZ - true frequency returned in HZ
AvAPI_Matrix FFT(data, n, detrend, window)
compute the Fast Fourier Transformations (FFT)
Returns: AvAPI_Matrix
Parameters:
AvAPI_Matrix& data - input data in columns
int n - number of points to use in FFT
Testing Your Model 43
Classes
Constructor
Returns: object
Parameters: None
AvBuild
This the entry point for Vibration Build
Modules
msc.Adams.Vibration.libAvAMDc libsip string traceback
msc.Adams.Vibration.Plotting.libVibPlotc os sys
libqtc re tempfile
Classes
AvBuild
AvBuildActuator
AvBuildFDElement
AvBuildFDInstance
AvBuildInputChannel
AvBuildOutputChannel
AvBuildPlot
AvBuildTest
class AvBuild
class AvBuildActuator
class AvBuildFDElement
class AvBuildFDInstance
class AvBuildInputChannel
Name(self)
Names(self)
StateVariable(self, Name, StateVarID, Actuator)
__init__(self, Parent, Name=None)
class AvBuildOutputChannel
class AvBuildPlot
class AvBuildTest
Name(self)(self)
Test(self, Name, modelFile, simScript, damping, modeList, start, end, steps, outName=None)
TestCompliance(self, Name, modelFile, simScript, damping, modeList, outName=None)
TestM(self, Name, modelFile, acfFile, modeList, start, end, steps, outName=None, SS=0)
__init__(self, Parent, Name=None)(self, Parent, Name=None)
Functions
bitBlt(...)
qAlpha(...)
qAppName(...)
qBlue(...)
qDrawPlainRect(...)
qDrawShadeLine(...)
qDrawShadePanel(...)
qDrawShadeRect(...)
qDrawWinButton(...)
qDrawWinPanel(...)
qGray(...)
qGreen(...)
qRed(...)
qRgb(...)
qRgba(...)
qVersion(...)
qt_xdisplay(...)
qt_xrootwin(...)
qt_xscreen(...)
AvFDElement
This the entry point for the FD Element
Modules
msc.Adams.Vibration.libAvAPIc os struct types
libsip re sys
Classes
AvFDElement
class AvFDElement
AvFDInstance
This the entry point for the FD Instance
Modules
msc.Adams.Vibration.libAvAMDc math string traceback
libsip re sys
Classes
AvFDInstance
class AvFDInstance
Add3D(self, amdModel)
FDElement(self)
IMarker(self)
JMarker(self)
Name(self)
Preload(self)
WritePy(self, oFile, space)
WriteXML(self, oFile, space)
FD Emement
__init__(self, Name, Type, Imark, Jmark, FdElement, preload)
AvFreqRespSol
The entry point for the Adams Vibration Mechanical Transfer functions
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Classes
AvMTF
Sol
class AvMTF
Adams Vibration class for computing mechanical transfer functions
Marker AvMechanicalTF:
@param Name: Name to assign to mechanical transfer fu
nction
@type Name: string
@param Model_base_name: base name for the model.
@type Model_base_name: string
@param Marker_in: Input marker object
@param Freq_range: Frequency range for analysis
@type Freq_range: Frequency range object
@type Marker_in: Marker spec object
@param Marker_I_out: Output I marker object
@type Marker_I_out: I Marker spec object
@param Marker_J_out: Output J marker object
@type Marker_J_out: J Marker spec object
@return: the object
@rtype: Object
__mul__(self, a, b)
class Sol
AvHelp
Testing Your Model 51
Classes
Modules
os string sys
Classes
AvHelp
class AvHelp
AvInputChannel
The entry point for the Adams Vibration Input Channel
Modules
msc.Adams.Vibration.libAvAPIc math re sys
libsip os string
Classes
AvInputChannel
AvInputChannelMarker
AvInputChannelStateVariable
class AvInputChannel
Adams Vibration Input Channel Base Class
class AvInputChannelMarker(AvInputChannel)
Marker Input Channel
class AvInputChannelStateVariable(AvInputChannel)
State Variable Input Channel
Functions
EvalFunc(argList, w)
User function used to test this module
AvIOC
#
Modules
msc.Adams.Vibration.libAvAPIc os struct types
libsip re sys
Functions
InputChannel(ChName, MrkInfo, ActObj)
OutputChannel(ChName, MrkInfo)
AvLinearize
Modules
msc.Adams.Vibration.libAvAPIc os struct types
libsip re sys
Classes
AvLinearize
class AvLinearize
Create a linear system model from an Adams non-linear system.
AcfToScript(self, iFile)
B(self)
Return the system B matrix
C(self)
Return the system C matrix
D(self)
Return the system D matrix
FindMarker(self, id, inList)
GetId(self, str)
ReadMatrix(self, matFile)
Read ABCD system matrices from the given dat file
RmFile(self, rFile)
Remove a file
Simulate(self, simScript, outName, damping, pInId, pOutId)
__init__(self, modelFile, inputList, outputList, simScript, damping, outName='Adams',
FDList={})
AvLinearize:
@param modelFile: Adams .adm file to be linearize
@type modelFile: string
@param inputList: List of input channels (AvInputChannel objects)
@type inputList: List
@param outputList: List of output channels (AvOutputChannel objects)
@type outputList: List
@param simScript: Script of Adams solver commands to acheive
operating point Or name of an existing .acf file
@type simScript: string
@param damping: Include damping True or False
@type damping: Bool
@param outName: Base name for solver output files default = Adams
@type outName: string
@return: the object
@rtype: Object
Functions
AvLinearModel(modelFile, inputList, outputList, simScript, damping, outName, mList)
56 Adams Vibration
Classes
AvLinearModel:
@param modelFile: Adams .adm file to be linearize
@type modelFile: string
@param inputList: List of input channels (AvInputChannel objects)
@type inputList: List
@param outputList: List of output channels (AvOutputChannel objects)
@type outputList: List
@param simScript: Script of Adams solver commands to acheive operating point
Or name of an existing .acf file
@type simScript: string
@param damping: Include damping True or False
@type damping: Bool
@param outName: Base name for solver output files default = Adams
@type outName: string
@param mList: List of modes to use null for all
@type mList: integer list
@return: the object
@rtype: Object
AvMarkerSpec
The entry point for the Adams Vibration Marker specification
Modules
msc.Adams.Vibration.libAvAPIc math re sys
libsip os string
Classes
AvMarkerSpec
class AvMarkerSpec
Adams Vibration class for specifying marker info
Marker AvMarkerSpec:
@param Name: Name to assign to marker data spec
@type Name: string
@param Marker_Adams_ID: Marker ID
@type Marker_Adams_ID: integer
@param MarkerName: Marker Name
@type MarkerName: string
@param FunctionType: <Translational, Rotational>
@type FunctionType: string
@param Global: <Global, Local>
@type Global: string
@param Direction: <X, Y, Z>
@type Direction: string
@return: the object
@rtype: Object
AvMechTFs
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Functions
CreateModel(BaseName, FreqRange, iDir, oDir)
DoVibrAnalysis(Ac, modl)
GetActionList(Ac)
RegisterAnalysis(AnaObj)
58 Adams Vibration
Classes
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Classes
msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol
Accelerance
Compliance
DynamicInertia
DynamicStiffness
ForceTransmissibility
Impedence
Mobility
MotionTransmissibility
class Accelerance(msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol)
# Accelerance
Model(self)
OutChLst(self)
PlotLegend(self)
Resp(self)
Response(self)
Results(self)
VarName(self)
__del__(self)
class Compliance
class DynamicInertia
(href="avfreqrespsol.html#Sol">msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol)
# Dynamic Inertia
60 Adams Vibration
Classes
class DynamicStiffness
Results(self)
VarName(self)
__del__(self)
class ForceTransmissibility(msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol)
Force Transmissibility
class Impedence
CreateIOChannels(self)
ErrStr(self)
Initialize(self, Model, InpMarkerList, OutMarkerList)
InpChLst(self)
Model(self)
OutChLst(self)
PlotLegend(self)
Resp(self)
Response(self)
Results(self)
VarName(self)
__del__(self)
class Mobility
(href="avfreqrespsol.html#Sol">msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol)
# Mobility
__del__(self)
class MotionTransmissibility
(href="avfreqrespsol.html#Sol"> Adams Vibration.InstrumentPacks.AvFreqRespSol.Sol)
# Motion Transmissiblity
msc.Adams.Vibration.libAvAMDc os sys
msc.Adams.Vibration.libAvAPIc re tempfile
Classes
msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol
Nibble
64 Adams Vibration
Classes
class Nibble(msc.Adams.Vibration.InstrumentPacks.AvFreqRespSol.Sol)
AvOutputChannel
This the entry point for the Output Cannel Property Editor
Modules
msc.Adams.Vibration.libAvAPIc math re sys
libsip os string
Classes
AvOutputChannel
AvOutputChannelCompliance
AvOutputChannelPredefined
AvOutputChannelUser
class AvOutputChannel
Adams Vibration Output Channel Base Class
Testing Your Model 65
Classes
class AvOutputChannelCompliance(AvOutputChannel)
Adams Vibration Predefined Output Channel
class AvOutputChannelPredefined(AvOutputChannel)
Adams Vibration Predefined Output Channel
VariableFunction(self)
Returns function string for the VARIABLE solver statement
VariableFunctionPrefix(self)
Returns the string for the solver function i.e. DX, ACCZ
WritePy(self, oFile, space)
WriteXML(self, oFile, space)
Predefined Output Channel
__init__(self, Name, MarkerID, GC, Dir, JMarkerID=0)
Predefined AvOutput Channels:
@param GC: Function <Displacement, Velocity, Acceleration, Force,
Angular Displacement, Angular Velocity, Angular Acceleration,
Torque>
@type GC: string
@param Dir: Direction <X, Y, Z, Mag>
@type Dir: string
class AvOutputChannelUser(AvOutputChannel)
Adams Vibration User Output Channel
AvPPTCmdExporter
The entry point for the Adams Vibration PPT interface
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Classes
VibPPTCmdExporter
class VibPPTCmdExporter
Write .cmd file to create a vibration model in PPT
Constructor:
@param fullModelName: Name to assigne to the model
@type fullModelName: string
@param outFileName: Name of file to write
@type outFileName: string
@param inputList: List of input channels in the model
@type inputList: list
@param outputList: List of output channels in the model
@type outputList: list
@param freqBegin: Starting frequency
@type freqBegin: double
68 Adams Vibration
Classes
Functions
psdFunc(argList, w)
User function used to test this module
AvResFileWrite
Testing Your Model 69
Classes
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Classes
XRFWrite
class XRFWrite
Functions
CallerName(TstName)
SetName(Name)
message_handler(msg, type, data)
Message handler for vibration
AvReview
This the entry point for Vibration Build
70 Adams Vibration
Classes
Modules
msc.Adams.Vibration.libAvAMDc libsip string traceback
msc.Adams.Vibration.Plotting.libVibPlotc os sys
libqtc re tempfile
Classes
AvReview
class AvReview
Functions
bitBlt(...)
qAlpha(...)
qAppName(...)
qBlue(...)
qDrawPlainRect(...)
qDrawShadeLine(...)
qDrawShadePanel(...)
qDrawShadeRect(...)
qDrawWinButton(...)
qDrawWinPanel(...)
qGray(...)
Testing Your Model 71
Classes
qGreen(...)
qRed(...)
qRgb(...)
qRgba(...)
qVersion(...)
qt_xdisplay(...)
qt_xrootwin(...)
qt_xscreen(...)
AvSuspension
Modules
msc.Adams.Vibration.libAvAMDc math string tempfile
Classes
AvSuspension
class AvSuspension
Adams Vibration Suspension Class
Functions
MultiComplianceMatrixIGround(model, acf, markerId, logFile, AxAyAz=0)
MultiComplianceMatrixIJGround(model, acf, iMarkerId, jMarkerId, logFile, AxAyAz=0)
MultiComplianceMatrixIJRef(model, acf, iMarkerId, jMarkerId, rMarkerId, logFile, AxAyAz=0)
AvTest
This the entry point for Vibration Build
Modules
msc.Adams.Vibration.libAvAMDc libsip string traceback
msc.Adams.Vibration.Plotting.libVibPlotc os sys
libqtc re tempfile
Classes
AvTest
class AvTest
Testing Your Model 73
Classes
Functions
bitBlt(...)
qAlpha(...)
qAppName(...)
qBlue(...)
qDrawPlainRect(...)
qDrawShadeLine(...)
qDrawShadePanel(...)
qDrawShadeRect(...)
qDrawWinButton(...)
qDrawWinPanel(...)
qGray(...)
qGreen(...)
qRed(...)
qRgb(...)
qRgba(...)
qVersion(...)
qt_xdisplay(...)
qt_xrootwin(...)
qt_xscreen(...)
Returns: object
Parameters:
string Title: plot title
AvAPI_Matrix FR: frequency response or transfer function matrix
AvAPI_Matrix Frequency: frequency vector used to calculate response
list of strings: list of input channel names
list of strings: list of output channel names
VibPlot : QWidget Class
From msc.Adams.Vibration.Plotting.VibPlot import *
void SetTitle(Title)
Set the main title for the plot
Returns: None
Parameters:
string Title: Title for plot
void SetTitleFont(Font)
Set the font used for the title
Returns: None
Parameters:
QFont Font: font to use
void SetTitleColor(Color)
Set the color used for the title
Returns: None
Parameters:
QColor Color: color to use
void SetCurrentColor(Color)
Set the default color used for plot objects
Testing Your Model 75
Classes
Returns: None
Parameters:
QColor Color: default color to use
VibPlot2D : VibPlot Class
Data Members:
enum eAxis
{
LEFT,
RIGHT,
BOTTOM
};
enum eScale
{
LINEAR,
LOGARITHMIC,
DB
};
enum eSymbol
{
NONE,
CIRCLE,
SQUARE,
DIAMOND,
TRIANGLE,
UTRIANGLE,
LTRIANGLE,
RTRIANGLE,
CROSS,
XCROSS,
HLINE,
VLINE
};
76 Adams Vibration
Classes
void SetGridMajorXPen(Pen)
Set the color and style used for the Major grid lines
Returns: None
Parameters:
QPen Pen: pen used to draw major X grid lines
void SetGridMinorXPen(Pen)
Set the color and style used for the Minor grid lines
Returns: None
Parameters:
QPen Pen: pen used to draw minor X grid lines
void SetGridMajorYPen(Pen)
Set the color and style used for the Major grid lines
Returns: None
Parameters:
QPen Pen: pen used to draw major Y grid lines
void SetGridMinorYPen(Pen)
Set the color and style used for the Minor grid lines
Returns: None
Parameters:
QPen Pen: pen used to draw minor Y grid lines
Testing Your Model 77
Classes
void SetLegendColor(Color)
Set the color used for legend
Returns: None
Parameters:
QColor Color: color to use
void SetLegendFont(Font)
Set the font used for the legend
Returns: None
Parameters:
QFont Font: font to use
uint InsertCurve(Name, X, Y)
Add a curve to the plot
Returns:
unsigned int: curve id
Parameters:
string Name: curve name (legend text)
AvAPI_Matrix X: x data for the curve
AvAPI_Matrix Y: y data for the curve
void RemoveCurve(cID)
Testing Your Model 79
Classes
void clear()
Clear the plot
Returns: None
Parameters: None
Constructors:
VibPlot2D()
Constructor
Returns: object
Parameters: None
VibPlot3D : VibPlot Class
Data Members:
enum eDRAWMODE
{
FLOWLINES,
WIREFRAME,
Testing Your Model 81
Classes
SHADE,
BOTH
};
void SetAxis(OnOff )
Set the state of axis
Returns: None
82 Adams Vibration
Classes
Parameters:
bool OnOff: state of axis
void SetTriad(OnOff )
Set the state of triad
Returns: None
Parameters:
bool OnOff: state of triad
void Remove(cid)
Delete a spline or surface from the plot
84 Adams Vibration
Utility Functions
Returns: None
Parameters:
unsigned int cid: spline or surface id
Constructors:
VibPlot3D()
Constructor
Returns: object
Parameters: None
Utility Functions
AvUtils
The entry point for the Adams Vibration Input Channel
Modules
msc.Adams.Vibration.libAvAPIc math string sys
libsip os struct traceback
Classes
AvModalEnergy
class AvModalEnergy
Functions
AvDacFileToMatrix(filename, nPts)
AvDatFileToMatrix(filename, nPts)
AvFFTDataActuator(argList, w)
AvMakeFrequency(start, end, steps, spaceLog)
Compute the descrete frequencies to use in the analysis
start - start frequency HZ
end - end frequency HZ
steps - number of steps to take from start to end
spaceLog - if true frequencies are log spaced other wise linear spacing
Note: List returned is steps+1 long in radians/sec
AvMessageHandler(msg, type, args)
Default Message handler for vibration
AvPSDDataActuator(argList, w)
AvReadDataFile(dataFile, n=-1)
AvReadDataFileFD(filename, nPts=-1)
AvRpcFileToMatrix(filename, nPts)
Description: Implementation of rpc3file_input class member functions
for reading in data from an RPC III time history file.
Reference: MTS RPC III file format document
Note: The last group may not be full. Full frames are only
required, not full groups. So the last group may
contain fewer than Number of frames in group.
Clarification - the group will be full but may not
contain all frames of acquired data
AvSolverSetup()
Mag(cVal)
Complex Mag and Phase
Phase(cVal)
byteSwap(CC)
formatExceptionInfo(logFile, maxTBlevel=10)
writeMatrix(matFile, Mat, title=None)
write a matrix to a file
@param matFile: File to write to
@type matFile: file object
@param Mat: Matrix to write
@type Mat: AvAPI_Matrix
@param title: String to preceed the matrix in the file
@type title: string
writeMatrix2(matFile, Mat, title=None)
write a matrix to a file
@param matFile: File to write to
@type matFile: file object
@param Mat: Matrix to write
@type Mat: AvAPI_Matrix
@param title: String to preceed the matrix in the file
@type title: string
writeMatrixXML(matFile, Mat, title='Matrix', space=2)
write a matrix to a XML file
@param matFile: File to write to
@type matFile: file object
@param Mat: Matrix to write
@type Mat: AvAPI_Matrix
@param title: Name of matrix [default: Matrix]
Testing Your Model 87
Utility Functions
Displaying Eigenvalues
The Eigenvalue table displays the eigenvalue of a given analysis.
To display eigenvalues:
1. From the Vibration menu, point to Review, and then select Display Eigenvalue Table.
2. Complete the dialog box as described in Eigen Information.
3. Select OK.
Note: You can display the same modal information from Adams PostProcessor by selecting the
Modal Info button in the dashboard.
116 Adams Vibration
Note: Doing a normal modes animation outside of Adams Vibration is called a frequency-domain
animation. So, if you’re referring to the Adams PostProcessor online help for more information on
animation, read the sections on frequency-domain animations
You can validate Adams Vibration results using Adams PostProcessor. Using Adams PostProcessor you can
plot several key pieces of data, including:
Frequency Response
Modal Coordinates
Modal Participation
Power Spectral Density (PSD)
System Modes
Transfer Function
3D
The following table outlines how you can view Adams Vibration results:
For general information plotting, refer to the online help for Adams PostProcessor.
of results. For example, plot FFTs of a time domain signal obtained with different windowing parameters and
display them in a waterfall format.
Note: If you change the axis limits, the upper and lower limits will have different meanings.
For example, in the logarithmic scale, the limit values are the exponent. So, if the values
are 2 and 3, the limits are 102 and 103 or 100 and 1000, respectively. In a linear scale,
values of 2 and 3 actually mean limits of 2.0 and 3.0, respectively.
3. Right-click the vertical axis of the plot, point to Axis: vaxis, and then select Select.
4. Set the Scale to either Logar, dB, or Linear.
Right-click the Page Layout tool , and select the 2 Views-over & under tool .
The plotting area of the screen splits into two plots, one containing the frequency response plot, and
the other containing a blank plot. You can then create a new plot in the blank region.
To plot PSD:
1. Display Adams PostProcessor in Plotting mode.
2. Set Source to PSD.
3. From the Vibration Analysis list, select the vibration analysis you want to plot.
4. From the Output Channels list, select the output channels you want to reference.
5. Select Add Curves.
Learn more about Power Spectral Density (PSD).
1. Split the plotting area by selecting the Page Layout: 2 Views, side by side tool .
2. Right-click the left view, and then select Load Vibration Animation.
3. Select Table of Eigenvalues.
4. Select Save to File and save as eigen.txt.
5. Right-click the right view, and then select Load Report.
6. Select eigen.txt.
Reviewing Your Model 121
Note: If you change the axis limits, the upper and lower limits will have different meanings.
For example, in the logarithmic scale, the limit values are the exponent. So, if the values
are 2 and 3, the limits are 102 and 103 or 100 and 1000, respectively. In a linear scale,
values of 2 and 3 actually mean limits of 2.0 and 3.0, respectively
3. Right-click the vertical axis of the plot, point to Axis: vaxis, and then select Select.
4. Set the Scale to either Logar, dB, or Linear.
Right-click the Page Layout tool , and select the 2 Views-over & under tool .
The plotting area of the screen splits into two plots, one containing the transfer function plot, and the other
containing a blank plot. You can then create a new plot in the blank region.
modal coordinates for this flexible body in MDF file format, re-start Nastran run to recover element stress
and strain information.
G ( z·, z, t ) = 0 (1)
where:
130 Adams Vibration
Linearization in Adams Vibration
x· = Ax + Bu
(2)
y = Cx + Du
where:
x = Vector of states of the linear model (a subset of vector z above)
y = Outputs from the linear model (defined with POUTPUT statements or output channels in the
graphical interface.)
u = Inputs to the linear model (defined with PINPUT statements or input channels in the graphical
interface.)
A,B,C,D = Real state matrices for the linear model computed by the linearization algorithm.
Specific details of the linearization process implemented in Adams Solver (FORTRAN) are given by Sohoni
[1986]. Negrut and Ortiz [2005] have given details of linearization process implemented in Adams Solver
(C++).
States of the linear model, x in equation (2) are a subset of states of the nonlinear model, represented by z in
(1). When performing normal-modes analysis, specification of inputs and outputs is not required. Therefore,
the problem is reduced to finding a solution to the homogeneous equation:
x· = Ax (3)
Representing the solution to equation (3) as:
i
i λt
x(t) = ζ e
where:
i
ζ = ith eigenvector
Adams Vibration Theory 131
Linearization in Adams Vibration
i
λ = ith eigenvalue
Substituting in equation (3) gives:
i i i
Aζ = λ ζ (4)
Equation (4) is the classic eigenvalue problem. This problem is solved in Adams Vibration using the well-
known QR method [Press et. al., 1994] for computing eigenvalues and eigenvectors. The A matrix includes
all damping effects in the model, however the damping terms are set to zero when the user selects the no
damping option.
Note that Adams Vibration always computes λ and ζ as complex quantities (complex eigensolution). The
complete eigensolution to equation (4) includes a modal matrix (matrix of mode shapes) and a vector of
eigenvalues.
Each eigenvalue has the form:
i 2
λ ≡ ω – ξ + i 1 – ( ξ ) = λ r + iλ i
i i i i i
where:
i i 2 i 2
ω = ( λ r ) + ( λ i ) is the ith natural frequency.
i i i
ξ = –λr ⁄ ω
Differences between proportional and general viscous damping – Adams Vibration implements general
viscous damping. In these cases, the internally computed damping matrix is no longer proportional to mass
and/or stiffness matrices. Adams Vibration always uses a complex eigenvalue solution.
sx ( s ) = Ax ( s ) + Bu ( s ) (5)
y ( s ) = Cx ( s ) + Du ( s )
where:
s = Laplace variable
132 Adams Vibration
Linearization in Adams Vibration
x(s), u(s), y(s) are the Laplace transforms of the state vector, inputs and outputs respectively.
From equation (5), the transfer function in the state-space form is given as:
(6)
(7)
where:
Z = Matrix of eigenvectors
q(s) = Array of modal coordinates
(8)
(9)
where:
–1
A m = Z AZ
–1
Bm = Z B
C m = CZ
Therefore, the transfer function for the model in modal space is given as:
Adams Vibration Theory 133
Vibration Analyses
(10)
When asking for the transfer function of a model, you specify the range of values for s and the number of
steps. At each step in the range of s, transfer function H(s) is computed from the expression in the right-hand
side of equation (10).
Transfer functions can be computed in two ways, that is, using equation (6) or equation (10). Solution of the
transfer function in the form of equation (6) is called the direct solution, while solution in the form equation
(10) is called the modal solution.
Adams Vibration uses the following steps to compute the transfer function for the model:
1. Get the given input/output channel specifications.
2. Compute state matrices in the state-space form as in equation (2).
3. Compute the complex eigensolution for the model using equation (4).
4. Transform to modal space using equation (9).
5. Compute transfer function from equation (10).
Due to degeneracy in the eigensolution, for some models, Z may not be invertible. In such cases, the transfer
function is computed using the direct solution of equation (6). The modal solution for transfer function
computation is much faster than the direct solution. If the transfer function is computed using the direct
method, it will not be possible to plot modal coordinates and participations or perform vibration animation
for the model. However, normal mode shapes can still be animated.
Vibration Analyses
Adams Vibration performs two types of vibration analyses:
Normal Mode Analysis to compute eigenvalues and eigenvectors for a model
Forced Vibration Analysis to compute the forced response of the model to vibratory inputs applied
using vibration input channels and actuators on the model. Eigenvalues and eigenvectors are also
available computed during the forced response analysis.
X· = AX + Bu
Y = CX + Du
134 Adams Vibration
Vibration Analyses
This linear representation is known as the minimal state-space representation or as the input/output
equations. Matrix A is called the linearization matrix and matrices B, C, and D have different names in the
technical literature. In general, vector X includes displacements, velocities and differential states of the model.
q
X = z .
v
Vector q includes a subset of all of the displacement states in the system while vector v is the corresponding
set of velocities. Vectors q and v are of the same size. Vector z includes all of the differential states defined in
the system. The z states are the results of DIFF, LSE, TFSISO, or GSE elements included in the model (those
elements define ordinary differential equations coupled with the mechanical system). Notice that vector q
may include a set of user-defined coordinates when using the Adams C++ Solver. The above references
describe the selection algorithm for the states in q. Adams Vibration, Adams Linear and the stand-alone
version of Adams Solver all provide tools to export the A, B, C, D matrices and the list of linearization
coordinates q, z, v, using two different file formats in ASCII form. Notice vector q includes neither Lagrange
multipliers nor force/variable definitions.
Vector u stands for inputs to the system. For the homogenous case (u=0) and no output equations, the state-
space representation reduces to:
X· = AX (11)
q
X = (12)
v
In this case, the linearization matrix A takes this form:
0 I
A = (13)
–1 –1
–M K –M b
Here M, K and b are matrices that may not be symmetric. I is the identity matrix. Using Equations (12) and
(13) into Equation (11), and simplifying we obtain:
q· = v
–1 –1
v· = – M Kq – M bv
These two equations combined reduce to the well-known form:
Adams Vibration Theory 135
Vibration Analyses
Aφ = λφ (15)
Adams Vibration uses a complex eigenvalue solution algorithm to compute eigenvalues λ and mode shapes
φ . In general, matrix A is non-symmetric and, in many cases, it can be ill conditioned or even singular.
Hence, mode shapes are not orthogonal. See [Meyer, 2000] for a complete set of properties and theorems
related to the eigensystem shown in Equation (15).
For the simple case defined by Equations (12), (13) and (14), there is an important property related the
computed mode shapes. A typical mode shape of the simple system can be split into:
φq
φ = (16)
φv
Putting Equation (16) and (13) into Equation (15) we obtain:
0 φq
I φq
= λ
–M K –M b φv φv
–1 –1
φ v = λφ q (17)
2
( λ M + λb + K )φ q = 0
However, matrices M, b and K need not be symmetric, hence orthogonality properties do not apply.
q
X = z (18)
v
136 Adams Vibration
Vibration Analyses
0 0 I
A = –A1 –A2 –A3 (19)
–1 –1 –1
–M K –M A4 –M b
Using Equation (19) into the homogenous Equation (11) we obtain after simplifications:
q· = v
z· + A 1 q + A 2 z + A 3 q· = 0
Mq·· + Kq + A 4 z + bq· = 0
The last two equations can be rewritten as:
·· z· A 2 A 1 z
0 0 z + I A3 0
·· ·+ = (20)
0 M q 0 b q A4 K q 0
or
··
z z· z
M' + b' + K' = 0 (21)
·· ·
q q q
Equation (21) is the MKB representation for the general system and, as above, matrices M', b', and K' can be
computed and exported using Adams Linear.
For the general case of Equation (19) the eigensolution will compute the eigenvalues and mode shapes using
the same algorithm used for the simple model with no differential states. Similarly, the linearization matrix
A is not symmetric and the orthogonality conditions do not apply except for very special cases. Defining a
generic mode shape as:
φq
φ = φz (22)
φv
and using Equation (19) and (15), we obtain after some manipulations:
Adams Vibration Theory 137
Vibration Analyses
φ v = λφ q (23)
2 0 0 I A3 A A φz
λ +λ + 2 1 = 0
0M 0 b A4 K φq
Eigensolution
Adams Vibration will compute eigenvalues of matrix A using a QR algorithm regardless of the type of model.
We emphasize that the A matrix is, in general, non-symmetric, hence all orthogonality theorems for
computed mode shapes do not apply. Moreover, the A matrix does not need to be full rank nor well
conditioned. Adams models with control systems or in singular configurations (for example, neutral static
equilibrium, bifurcation points and so on) may exhibit multiple zero value eigenvalues or large real
eigenvalues.
In the general case, the size of the A matrix is:
N = 2n q + n z (24)
Where nq is the size of the q vector (vectors q and v are of the same size) and nz is the size of the z vector. The
eigensolution will compute a set of nr real eigenvalues and 2nc complex eigenvalues (all complex eigenvalues
form a set of conjugate pairs). Therefore:
1N = 2n q + n z = 2n c + n r (25)
Notice that Adams Vibration will only display a table with nc+nr eigenvalues only (conjugate complex values
are not displayed). See Eigenvalue Table Reported in Adams View for an example output using the Adams
Vibration user interface. Notice in the example in Table 1, there are 2 real-only eigenvalues and 2 complex
eigenvalues. Hence the size of the A matrix is 2*2+2=6.
By default the eigensolution is performed on the full computed A matrix. Hence, all damping properties in
the system are taken into account. If you want to compute the eigensolution without the damping properties,
then uncheck the Damping checkbox in the Perform Vibrational Analysis dialog box.
A very important notice is due here. If you use the Adams Solver C++, and if you uncheck the Damping
checkbox, Adams Vibration will set matrix b to zero in Equation (19) to get:
0 0 I
A = –A1 –A2 – A 3 (Adams Solver C++) (26)
–1 –1
–M K –M A4 0
However, if you use the Adams Solver FORTRAN, and you uncheck the Damping checkbox, Adams
Vibration will set both matrix b and matrix A3 to zero:
138 Adams Vibration
Vibration Analyses
0 0 I
A = –A1 –A2 0 (Adams Solver FORTRAN) (27)
–1 –1
–M K –M A4 0
If you would like Adams Solver C++ to flush the A3 matrix too, set the environment variable
MSC_ADAMS_SOLVER_NODAMP_DIFF to any value. The rationale behind not flashing the A3 matrix was
based on the purely philosophical assumption that damping is a mechanical property hence the coupling
between velocities and differential states (matrix A3) should be left unchanged.
See the Adams Solver C++ documentation for the command LINEAR for more information of using user-
defined coordinates. By default, vector q in Equations (12) and (18) is a subset of the global translational
displacements and instantaneous rotations of the center of mass of each PART. If there are FLEX_BODYs in
the model, vector q includes also all the corresponding states for the modal representation of each
FLEX_BODY. However, in rotordynamic models, users may need to obtain a linearization of the system
using a different set of coordinates (for example, r) defined as:
r = r(q) (28)
In that case, Adams Vibration will linearize the system into this form:
r· = A∗ r (29)
As presented in [Negrut et al., 2005], the eigenvalues in A* and A may not be the same.
In all cases, all computed eigenvalues may be expressed as:
2
λ = α ± iβ = w ( ξ ± i 1 – ξ ) (30)
Where w is defined as the undamped natural frequency and ξ is defined as the damping ratio. Solving
Equation (30) for both the undamped natural frequency and the damping ratio, we get the following results
for real-only eigenvalues:
w = α (31)
ξ = 1
For complex eigenvalues Equation (30) results in:
2 2
w = α +β (32)
α-
ξ = ---
w
See Eigenvalue Table Reported in Adams View for an example output showing the computed undamped
natural frequency, damping ratio, real value and imaginary value of the displayed eigenvalues of the model.
Adams Vibration Theory 139
Vibration Analyses
Undamped Natural
Mode Number Frequency ω r Damping Ratio ξ Real λr Imaginary λi
1 0.00617426 1 -0.00617426 0
2 16.6257 1 -16.6257 0
3 0.270866 0.23569 -0.0638404 +/-0.263235
4 0.712246 0.580427 -0.413406 +/-0.57999
Eigenvalues can be plotted as a complex scatter on a real-imaginary axis, as shown in Figure 1 Complex Scatter
Plot. The real part of eigenvalues corresponds to damping in a model. The imaginary part corresponds to
stiffness in the model. A mode with an eigenvalue of negative real part is considered stable. Conversely, a
mode with eigenvalues of positive real part is unstable. As shown in Figure 1 Complex Scatter Plot, eigenvalues
lying in the left half plane are stable and those in the right half plane are unstable.
A model with all stable eigenvalues, if perturbed, will return to its original unperturbed configuration on
removal of the perturbation. A perturbation applied to a model with unstable eigenvalue(s) may cause
unstable modes to be excited. In this case, the model will have an unbounded response to this perturbation.
For more information, see Reference 4.
Regarding computed mode shapes ( φ ) , Adams Vibration does not export the computed mode shapes.
Should you need the computed raw mode shapes from matrix A, we suggest exporting the A matrix and
140 Adams Vibration
Vibration Analyses
compute the mode shapes using an eigensolver of your choice. The A may be exported using the
LINEAR/STATEMAT Solver command or using the Adams View user interface.
For animation purposes, Adams Vibration uses the following equation:
Q = Tφ q (33)
to obtain all coordinates in the model for given a particular mode shape. Matrix T is a transformation matrix
from the minimal state-space representation to the full representation of the model. Vector Q is used to
animate the mode shapes in the post processor and to display the Normalized Coordinates in the Energy
Tables options. A similar transformation is used to compute the velocity and differential states allowing the
computation of Kinetic Energy, Strain Energy and Dissipative Energy tables.
X· = AX + Bu (34)
Y = CX + Du
As shown in the previous section, vector X stands for the minimal state-space representation, matrix A is the
linearization matrix and matrices B, C and D are the input/output matrices computed using the definitions
of the input and output channels. Adams Vibration requires you to construct a vibration analysis using the
graphical interface. A vibration analysis consists of a collection of all the input and output channels, the
operating point specification, the frequency range and number of steps in this range. Options to turn off
damping matrices and the usage of user-defined states are also available.
When using the Adams Vibration user interface to create an input channel, each input channel results in an
action-only SFORCE being created in the model along with a VARIABLE. The VARIABLE is used to define
the SFORCE. The expression for the variable is set to zero in the Adams Solver model because the
Adams Vibration Theory 141
Vibration Analyses
computation of the B and D matrices do not require a value for the said VARIABLE. However, the input
channel definition will be used in the FRA subsequent analysis.
When creating an output channel, each output channel results in one VARIABLE being created. Function
expression for this entity depends on the type of output channel you define. On defining a vibration analysis,
the variable corresponding to the input channels are collected into a PINPUT and variables corresponding
to the output channels are collected into a POUTPUT. The model is linearized using this PINPUT and
POUTPUT pair. As shown in Figure 2. Input and Output Channels, each input channels contributes one
column to the B matrix. Each output channel defines one row of the C matrix.
The FRA proceeds with taking the Laplace transform of Equation (34) to obtain:
sx ( s ) = Ax ( s ) + Bu ( s ) (35)
Y ( s ) = Cx ( s ) + Du ( s )
Where s is the Laplace variable and x(s), u(s) and Y(s) are the transforms of X, u and Y respectively. Solving
for Y(s) we find:
–1
Y ( s ) = ( C ( sI – A ) B + D )u ( s ) (36)
Defining the transfer function H(s) as:
–1
H ( s ) = C ( sI – A ) B + D (37)
The forced response of all output channel is then:
Y ( s ) = H ( s )u ( s ) (38)
Adams Vibration will compute the value of each Y(s) for each s specified in the Vibration Analysis definition.
If the size of vector X is N, and there are ni inputs and there are no outputs, then the sizes of the matrices in
Equation (37) are:
AN × N
BN × ni
Cn0 × N
D n0 × ni
H n0 xni
Adams Vibration user interface allows the user to set a range of values for the variable s using different formats.
Notice that for each s computing the response Y(s) requires inverting a matrix of size NxN as shown in
Equation (37). If matrix A can be diagonalized, the response for each s is obtained following the
diagonalization algorithm shown in section Transformation to Modal Space.
142 Adams Vibration
Vibration Analyses
Transfer Function
The plots for the transfer function H(s) are computed from equation (37). Adams Post Processor displays each
plot by first selecting an input channel k and then selecting an output channel j in the post-processing
window. Each plot corresponds to the entry Hjk of the H(s) matrix for all values of s.
These plots are equivalent to setting input channel k to 1 and all other input channels to zero in Equation
(38), and displaying the jth entry of the resulting matrix-vector multiplication. See Figure 3 below.
Besides displaying each entry of the transfer function matrix H(s), Adams Post Processor allows plotting the
frequency response Y(s) for each output channel. Equation (38) may be rewritten as follows:
s = s b, …, s e
Adams Vibration Theory 143
Vibration Analyses
Here sb and se are the Begin and End frequencies respectively as set by the user in the Vibration Analysis user
interface.
2
S yy ( s ) = h ( s ) S xx ( s ) = h∗ ( s )h ( s )S xx ( s )
Where h*(s) stands for the complex conjugate of h(s).
Adams Vibration can be used to define input channels with actuators of either PSD type or non-PSD type.
Actuators of the non-PSD type are standard actuators with computed Fourier Transforms obtained from
measured input signals or theoretical functions entered as symbolic expressions in the user interface.
Actuators of the PSD type define a Power Spectral Density function (the Fourier Transform of the
autocorrelation of some signal).
Regardless of the type of input channels (either PSD type or non-PSD type), Adams Vibration computes
and displays the Power Spectral Density response of each output channel, or PSD(s).
For input channels using non-PSD type actuators, a non-standard estimation of the Power Spectral Density
is computed as follows:
1 2
u j ( s ) = -------- u j ( s ) (40)
2df
Here df is the difference between End and Begin frequencies as setup in the Vibration Analysis data. Notice
this estimation of the Power Spectral Density returns complex values. Using Equation (40), the response
PSD(s) is computed using the standard equation:
Here PSDk(s) is the response Power Spectral Density function for the kth output. Hkj*(s) is the complex
conjugate of Hkj(s). The summation is implied 1 to ni. Adams Post Processor does not compute the individual
contribution of each input channel when displaying PSDk(s). Notice we assume there are no cross
correlations between the inputs.
For actuators of the PSD type there are two cases to consider. If there are no cross-power spectral actuators
between the different input channels, the PSD(s) output is computed using the standard equation:
PSD k ( s ) = H∗kj ( s )Hkj ( s )uj ( s ) (PSD type actuators, no cross correlation) (42)
j
144 Adams Vibration
Vibration Analyses
If there is a set of cross-power spectral actuators U(s), they can be ordered in matrix form as:
U ( s ) = U ij ( s ) n × ni
(43)
i
For this second case, the Power Spectral Density response PSD(s) is computed as:
Modal Coordinates
Equation (35) can be transformed from the standard state-space representation into a "modal" representation.
We define the "modal" states q(t) as follows:
x ( t ) = zq ( t ) (45)
Matrix Z in Equation (45) is the modal matrix composed by the mode shapes obtained from the eigensolution
of the system. Notice Equation (45) is a representation of the solution x(t) in the time domain. Transforming
Equation (45) into the frequency domain, we obtain:
x ( s ) = Zq ( s ) (46)
Using Equation (46) into Equation (35) and simplifying we obtain an equivalent representation of the
frequency response of the system in terms of the "modal" states q(s):
Adams Vibration Theory 145
Vibration Analyses
sq ( s ) = A m q ( s ) + B m u ( s ) (47)
Y ( s ) = Cm q ( s ) + Dm u ( s )
Matrices Am, Bm, and Cm are obtained from:
–1
A m = Z AZ (48)
–1
Bm = Z B
C m = CZ
Adams Vibration computes and displays the frequency response of each modal state qk(s). From Equation (47)
we obtain in matrix form:
–1
q ( s ) = ( sI – A m ) B m u ( s ) = M ( s )u ( s ) (49)
Equation (49) can be interpreted as the frequency response of each modal state. Moreover, for a given input
channel j and a given entry k in the modal vector q(s), Adams Vibration computes and plots:
q k ( s ) = M kj U j ( s ) (50)
s = s b, … s e
Equation (50) is the frequency response of the kth entry in the modal vector due to the jth input channel.
Adams Post Processor displays Equation (50) for the complete range of selected frequencies s. See Figure 4
below.
Note: Currently, in the Modal Coordinates plot options, the user interface wrongly shows the
number of different eigenvalues instead of the size of the state vector q(s). The modification of
the user interface will be executed in compliance with enhancement ADMS-37553.
146 Adams Vibration
Vibration Analyses
While Equation (50) displays the response of a single state qk(s) for the whole range of specified frequencies s,
Adams Post Processor also displays the complete response of the modal vector q(s) for a given frequency so.
Evaluating Equation (49) for s=so and for the jth input channel (all other input channels are set to zero) we
obtain:
(51)
Vector q(so) is of size N (which is the size of the state matrix A) and Adams Post Processor display the contents
of this array.
See Figure 5 for an example plot of Equation (51). Notice the horizontal axis is the mode number from 1 to N
where N is the size of the linearization matrix A (see Equation (25)).
Adams Vibration Theory 147
Vibration Analyses
Modal Participation
While the modal coordinates define how active a certain mode qk(s) is at a given frequency s (see Equation
(50)), the modal participation identifies how much a given input ui(s) and a given mode qk(s) contribute to
the total frequency response of a specified output Yj(s). From Equation (47) we obtain:
(52)
The options to plot the Modal Participation in the Adams Post Processor allow selecting the ith input, the kth
mode and the jth output. See Figure 6 below.
148 Adams Vibration
Vibration Analyses
Note: Currently the plotting options, in Modal Participation plot, wrongly show the number of
different eigenvalues instead of the full range of modal coordinates. Also there is an incorrect
algorithm implementation providing approximate results only. The user interface and
implemented algorithm will be corrected following enhancement ADMS-37565.
(53)
where:
Adams Vibration Theory 149
Vibration Analyses
(54)
where:
ζij = ith column vector of matrix Ψ j , which is condensed mode shape matrix from system mode
shape matrix Φ , corresponding to six degrees of freedom of PART j
Μ j = Mass matrix of PART j
Adams Vibration breaks this modal kinetic energy contribution of PART j in nine components to present it
in modal energy tables:
1
K1j = mζij (1)* ζij (1)
2
1
K 2j = mζij (2)* ζ ij (2)
2
1
K 3j = mζij (3)* ζij (3)
2 (55)
1 j *
K 4j = ζ i (4) I xx ζ ij (4)
2
1
K 5j = ζ ij (5)* I yy ζ ij (5)
2
1
K 6j = ζ ij (6)* I zz ζ ij (6)
2
(56)
n
Γi = τ i j (57)
j =1
where:
Γi = Total kinetic energy of mode i
n = Number of parts in the model
τ i j = Kinetic energy contribution of PART j to mode i
Percentage distribution of PART j mode i kinetic energy in direction e is defined as:
(58)
Above equation shows that the percentage kinetic energy contribution of any degree of freedom to a
particular mode is independent on natural frequency of that mode and depends on the product of the mass
or inertia and square of the mode shape amplitude (mass and inertia terms) or product of mode shape amplitudes
(product of inertia terms) of the mode in that directions. As the sum of the kinetic energy contributions of all
degree of freedoms in that mode shape (not part degrees of freedom) is made equal to 100, through the
definition in equation , it is easy to identify the relative importance of various degrees of freedoms. This will
help to identify which particular degree of freedom is contributing more or less to the overall modal kinetic
energy.
Percentage kinetic energy contributed by PART j to mode i is defined as:
(59)
where:
Adams Vibration Theory 151
Vibration Analyses
It should be noted that the large kinetic energy contribution can be due to large mass (inertia) or motion of that
degree of freedom. Therefore, the modal kinetic energy density needs to be calculated to remove this ambiguity and
make it dependent only on mode shape. The modal kinetic energy density for a given mode is defined as the ratio of
modal kinetic energy contribution of a degree of freedom to the rigid body mass of the part.
Sometimes it is advantageous to normalize the modal kinetic energy contributions with respect to generalized mass
of that mode. This will make these modal kinetic energy distributions independent of mode shape normalization.
Adams Vibration computes the kinetic, strain, and dissipative energy distribution within modes of your
model. Table 1 Modal Energy Distribution shows an example of these distribution tables. These distributions
are important indicators of which components of the model have the greatest contribution to a given mode.
As in this example, PART_2 has the greatest contribution to the kinetic energy in this mode. The Strain
energy tables indicate that SPRING_2 stores the most amount of strain energy in this mode. Similarly, from
the dissipative energy table, SPRING_2 dissipates the most amount of energy in this mode.
ii. Strain energy distribution - Compliant components, such as SPRINGDAMPER, SFORCE, BUSHING,
and so on, contribute to the computation of strain energy in a mode. In addition, FLEX_BODYs in the
model contribute to strain energy computation.
Strain energy due to a compliant element p is:
(60)
where:
p
σ i = Strain energy in complaint element p for mode i
Κ p = Matrix of size equal to model stiffness matrix, with all zero entries except stiffness matrix
entries contributed by compliant element p.
Percentage distribution of strain energy for mode i is given as:
Adams Vibration Theory 153
Vibration Analyses
p
100 × σ i
S pi = m
σ
p =1
p
i ; p=1, …,m (61)
where:
Stress Recovery
With Adams Vibration you can recover stresses and strains on flexible bodies. Recovering stresses on flexible
bodies is called Modal Stress Recovery (MSR). Adams Vibration allows you to export modal-coordinates
corresponding to flexible body modes that can later be used as input to FEM software like Nastran to recover
the stresses in the flexbody.
The linear deformation (y) of the flexbody nodes can be approximated as a linear combination of M
orthogonalized mode shape vectors ( Ψ ) of that flexbody.
(62)
The basic advantage of the modal superposition is that the deformation behavior of a component with a very
large number of nodal DOF can be captured with a much smaller number of modal DOF.
Adams Vibration exports the modal coordinates ( q ) in a Modal Deformation File (MDF) format (binary).
FEM software like Nastran then does the summation to get linear deformation of flexbody nodes and then
recovers stresses and strains as follows,
(63)
where:
Note: Due to this constraint, the frequency response peaks may be shifted from the frequencies of
the normal modes of the model.
Vibration Actuators
A vibration actuator defines the magnitude and phase of the applied forcing function. Vibration actuators are
required for modeling forcing function in forced response analysis. Phase angle, as defined in a vibration
actuator, is with respect to the positive direction of the marker in the vibration input channel on which this
actuator is defined.
Vibration actuators are applied at the input channel after the model is linearized. Therefore, vibration
actuators are only in effect for frequency domain analysis and have no effect on the operation point analysis
for the model.
where:
f = force magnitude
θ = phase angle
The phase angle θ is measured with respect to positive direction of the marker axis for the input channel on
which this actuator is acting.
Force Type
The force rotating mass actuator is represented by two actuators. The Leading and Lagging actuators are
represented as:
where:
r = Radial offset
ω = Frequency of excitation
When you want to incorporate vibratory effects due to an unbalanced mass in your vibration analysis, you
must create two vibration actuators acting on the same input channel. The first actuator must be defined as
a Leading actuator and the second as the Lagging actuator.
Moment Type
The moment type of rotating mass actuator is applicable for simulating moments due to radial, as well as
axially offset unbalanced masses. The leading and lagging actuators are represented as:
where:
Mle = Moment applied in the leading actuator
Mla = Moment applied in the lagging actuator
d = Axial offset between unbalanced masses
As with the force type rotating mass actuator, to incorporate vibratory moment effects due to an unbalanced
mass in your vibration analysis, you must create two vibration actuators acting on the same input channel.
The first actuator must be defined as a Leading actuator and the second as the Lagging actuator.
PSD Actuator
The PSD actuator is for defining a spectrum that you want to apply to the model. For more information on
power spectral density, see Reference 4. The PSD actuator is specified using a spline. You can create a spline
using the Function Builder in Adams View. In Adams Vibration, you can specify the autocorrelation PSD of
Adams Vibration Theory 157
Modeling of Vibration Entities
an input channel to itself, as well as the cross correlation PSD to other input channels. Section 4d provides
details of how auto and cross correlations are used for computing PSD response.
PSD type actuators cannot be mixed with swept sine, rotating mass, or user-type actuators in the same
vibration analysis. Response solution for PSD actuator is different from the force vibration response analysis.
from Adams to Nastran in MDF file format. Adams provides two options to user to recover acoustic pressure
in Nastran from the modal co-ordinate data.
1. Recover acoustic pressure without fluid loading.
2. Recover acoustic pressure with fluid loading.
2 T ad ams (64)
{ ξ } = –ω [ Z 2 ] [ a ] { ξ }
f s
By knowing right hand side vector for every frequency step from Adams, the above equation can be solved
for ξ . From here, acoustic pressure {p} can be recovered using following equation.
f
{ p} = [Φf ]{ ξ } (65)
f
By making use of Nastran Eq. 13-66 to Eq. 13-70, the fluid modal co-ordinates can be written in terms of
Adams structural modal co-ordinates.
c
{ ξ s } = [ C ] { ξ adams }
s
–1
[ C] + [I – ω2 + [Z1 ][a ][ Z2 ][ a]T ] (67)
The correction matrix [C] in above equation can be used to get judgment of fluid loading on structure. This
is useful matrix to check the validity of assumption made during Adams simulation.
Finally, the corrected fluid modal co-ordinates can be get as,
c T
{ ξ f } = – ω 2[ Z 2 ] [ a ] [ C ] { ξ sadams } (68)
By knowing right hand side vector for every frequency step from Adams, the above equation can be solved
c
for ξ . From here, acoustic pressure {p} can be recovered using following equation.
f
160 Adams Vibration
Adams Vibration References
{ p } = [ Φ f ] { ξ fc } (69)
Linear
Logarithmic
Close Action Select one of the following:
Delete Plot - When you close this dialog box, Adams Vibration
deletes the plot.
Save Plot - When you close this dialog box, Adams Vibration
saves the plot in the database and creates a page for it in Adams
PostProcessor.
If you set Close Action to Save Plot, Adams Vibration displays the following option:
Name Enter the name for the plot object that will be stored in the database.
164 Adams Vibration
Create Design Variable from File
Sum - The absolute values of the differences between the curves at each
of their points are added together to yield the error value.
Maximum - The maximum difference between the curves represents the
error value.
Average - The absolute values of the differences between the curves at
each of their points are added together and then averaged to yield the
error value.
Mode Number Enter the mode number of interest.
Test Value Enter the target value. The absolute value of the difference between the test value
and the natural frequency for the specified mode will be the return value for the
macro.
Object Type Select an object type.
Object Name Enter the name of the object of interest.
Dialog Box - F1 Help 169
Create Vibration Multi-Run Script
Plant State
Reference Marker
170 Adams Vibration
Create/Modify FD 3D Damper
Create/Modify FD 3D Damper
Vibration -> Build -> FD 3D Damper -> New/Modify
Pfeffer Linear - Contains two linear dampers and two linear springs.
Simple FD - Contains one linear damper and two linear springs.
Simple FD-Bushing - Contains one linear damper and two linear springs.
General
Depending on the setting of Type, Adams Vibration displays one or more of the following options:
Dialog Box - F1 Help 171
Create/Modify FD Damper
Create/Modify FD Damper
Vibration -> Build -> FD Damper -> New/Modify
Pfeffer Linear - Contains two linear dampers (Damping 2 and 3) and two
linear springs (Stiffness 1 and 3).
Simple FD - Contains one linear damper (Damping 3) and two linear springs
(Stiffness 1 and 2).
Simple FD-Bushing - Contains one linear damper (Damping 3) and two
linear springs (Stiffness 2 and 3).
General - Contains three linear dampers (Damping 1, 2, and 3) and three
springs (Stiffness 1, 2, and 3).
Depending on the setting of Type, Adams Vibration displays one or more of the following options:
C 1/2/3 Enter the damping value(s) for the damper.
K 1/2/3 Enter the stiffness value(s) for the damper.
Preload Enter the value of the preload in the component.
Swept Sine.
Rotating Mass.
PSD. See Power Spectral Density.
User. See User-Defined Function.
Force Magnitude Enter the force magnitude.
Phase Angle (deg) Enter the phase angle (in degrees).
Define the parameters for Input Channels. In these dialog boxes, you can also assign and modify vibration
actuators.
Eigen Information
Vibration -> Review -> Display Eigenvalue Table
Allows you to import a previously generated results file and attach it to a vibration analysis. This enables you
to plot vibration data generated from the eigen and state matrices in the results file. The imported results file
and the vibration analysis must be from the same model.
176 Adams Vibration
Modal Info Computation
Specifies options for computing modal energy during your vibration analysis.
Modal Information
Vibration -> Review -> Display Modal Info Table
Modal Coordinates - This table lists the relative and absolute values
of modal coordinates at a specified excitation frequency.
Modal Participation - This table lists the modal participation of
modes in the output channels. Highlights modes with the largest
contributions.
Modal Energy - This table lists the normalized coordinates and
distribution of kinetic, strain, and dissipative energies in modes.
Highlights modeling entities with the largest contributions. It also
lists Marker Mode Shapes.
Vibration Analysis Enter the name of the vibration analysis whose modal information you want
to display.
Frequency Enter the frequency at which you want to view the modal information.
Display Phase Values Select to display the phase values for each mode.
Base Font Size Select the font size for the text in the table.
File Format Select the type of file to which you want to save the modal information.
178 Adams Vibration
Nastran Modal Export
Nodal Info
Tools > Plugin Manager > Vibrartion > Build > nodal Info > New > Nodal Info
To plot stress and strain frequency response functions of selected nodes on flexible body in Adams
PostProcessor.
Creates and runs a vibration analysis (see Vibration Analysis Calculation Methods to learn more).
Note: You cannot select input channels with actuators of PSD type and
input channels with actuators of non-PSD type in the same
analysis.
Dialog Box - F1 Help 181
Perform Vibration Analysis
Decibel
A unit of measurement for attenuation or amplification of a signal, given as 20*log (input/output).
Eigensolution
An analysis that uses a model, along with an existing transient analysis step or static analysis, to compute the
frequency domain behavior of the system. The results are a collection of eigenvalues describing the natural
modes, and eigenvectors describing the normal mode shapes of the system components.
akima
cspline
cubic
linear
Note: The detail definitions are in Design-Time Functions in Adams View.
Phase Angle (deg) Enter the phase angle (in degrees).
If you're modifying an existing input channel, Adams Vibration displays the following option:
Cross Correlation Select if you want to specify cross correlation options. Opens the PSD Cross
Correlation dialog box.
Force
Moment
Leading/Lagging Select one of the following:
Leading
Lagging
Mass Enter the unbalanced mass.
Radial Offset (in plane) Enter the radial distance of the unbalanced mass from the axis of rotation.
Offset Normal to Plane Enter the offset along the axis of rotation.
Appendix 191
Entering Swept Sine Function
Frequency
The rate of oscillation of harmonic motion.
Note: You can hold down the <Ctrl> key as you click to select multiple nodes.
Note: You can hold down the <Ctrl> key as you click to select multiple modes.
Input Channel
A driver in the model, providing stimulus for the vibrational analysis.
Natural Modes
See Normal Modes.
194 Adams Vibration
Normal Mode
Normal Mode
A frequency at which a given system resonates in a particular way.
Normal Modes
The modes that Adams Vibration produces. Often called principle modes or linear system modes in structural
dynamics texts. Normal modes are the results of an eigensolution. This is to differentiate them from
component modes that can be computed by other means.
Number of Modes
If you do not specify the number of modes you want to compute, Adams Vibration automatically chooses a
suitable number of modes based on the model size.
Operating Point
A point at which Adams linearizes a model. Because, traditionally, Adams models involve nonlinear elements,
you need to specify an operating point. To have an appropriate operating point, your system must meet the
following two conditions:
It must have more than one degree of freedom, so that it is capable of oscillation.
The Jacobian matrix for the system must be time invariant.
Output Channel
Instrumentation on the model that records some quantity of interest.
Principle Modes
See Normal Modes.
Resonance
A condition where the vibration actuator drives the normal mode of the system.
Appendix 195
Rigid Body Mode