Bar type Ionizer

HDC-AC with build-in high-voltage power supply

Bar type Ionizer ELIMINOSTAT CABX


Replaceable

HDC-AC technology ensures the long-term stability of static elimination while reducing the cleaning frequencies.
Achieves 30% improvement in static elimination time and product size compared to our conventional products!

TIMER RESET
Indicator Panel TIME SELECT

Main Features
HDC-AC techonology provides a stable static elimination capability POWER CLEANING
with the feature of unrequring cleaning over a long period of time. RUN ALARM
Function
❶ Increase in capacities
POWER : When power turns on, Green LED lights up.
❷ Long-term stability of static elimination
❸ Reduce the abrasions in emitter needle RUN : Under normal operation, Green LED lights up.
❹ Ultra low ozone
ALARM : When an overcurrent occurs in the main circuit or slight discharge occurs at the high voltage,
❺ Superior ion balance RED LED lights up.
❻ Minimum flow type nozzle CLEANING : When the accumulated operation time set by T・SELECT is over, Yellow LED lights up. To
release, press the RESET botton.
❼ Cleaning timer TIMER RESET : The botton to turn off CLEANING LED
❽ Emitter needle variation
T・SELECT : To preset the accumulated operation time for CLEANING LED to light up.
❾ Safe features
Dimensional Diagrams
● 30% improved in both sta�c elimina�on �me and size Mounting Pitch: L+32
(compare to conven�onal products) Mounting Pitch: L-34
22

Improved sta�c elimina�on �me and miniaturized product


size both in 30% and more.
Mounting Bracket
● Small flow type discharge needle nozzle with low air (angle adjustable)
Power & Signal Connector Mounting Bracket
consump�on is also available L(350 ~ 3100) Pitch: 250mm
10
Two types of discharge needle nozzles are available, normal Indicator Panel Intermediate Bracket (over 1100mm) Electrode Base(ABS)

flow nozzles and small flow nozzles (used for reduced


67

74
59.8
84

compressor air consump�on). Easy to replace nozzles. Please


0
9 1
2
8
7

I N PU T :2 4 V 150mA
DC
3

6 5 4

A IR PR ES S U RE :0 .01-0.5MPa(CleanandDry
AirOnly)

see our website for air flow data.


10

32 65 Electrode Base (stainless)

● Pre-set cleaning schedule on �mer Air fitting


350 ~ 1600mm: φ6 2 on 2 ends
The LED lights up to no�fy the cleaning �me of the discharged 1850 ~ 3100mm: φ8 2 on 2 ends Emitter Needle Nozzle Electrode Base (stainless)

needle based on the preset light up schedule. The schedule


can be preset by the �mer. There are 9 pa�erns can be set Pitch50mm

between 100 to 10000 hours. It is also possible to preset as


light off.
● Varia�on of the discharge needle
The silicon discharge needle can be used for an environment
where it does not allow small amount of dust. Model ELIMINOSTAT CABX
Ion Generation Method Corona Discharge Method(HDC-AC)
● Safety features Input Voltage DC24V± 5%
Slight discharge detec�on with low voltage of DC 24V input Electricy Consumption 3.6VA
ensure safety during opera�on. Output Voltage ±10kVo-p
Abnormal Output Non-Voltage Contact (Normal Close / MOS FET Relay )
Dimensions 29×92×350~3100mm (DxHxW)
Available Air Supply 0.01MPa~ 0.5MPa
Ion Balance Within ±30V (Distance 300mm, Air Pressure 0.3MPa nitial setting)
Environment Temperture: 5~40°C, Humidity: 15%~85% (Without Condensation)
Air Supply: Clean Dry Air
Accesories Manual, Mounting Bracket, Power & Signal Cable(3m)
Intermidiate Bracket(over 1100mm), Emitter Needle Removal Kit