Professional Documents
Culture Documents
9, 10, 11, 13 & 14. Fire Hazard by Short Circuit due to Arcing between Conductors of
Wiring
12. Fire Hazard by Short Circuit due to Arcing between Conductors of Wiring
15. Protection Failure of Short-circuit by Arcing along the Insulating Material between
Two Conductors of Wiring or Wiring Devices
16b & 17. Electrical Discharge and Fire Hazard of a Flexible Cord with a Partial
Disconnection
22. What we have done, what we are doing now and what we are going to do
23. Result of the investigation on plugs and receptacles damaged by tracking (Interim
Report)
24. Idea of the Interim Report on the Results of Examinations on Electrical Plugs
27. Possibility of Gas Explosions Caused by the Electric Sparks of Domestic Switches
28. Ignition Possibility of Inflammable Mixtures with Burning Cigarettes
36. Metallurgical Study on the Formation of Melting Marks at the Scene of Fire
37. On The Effect of Thermal Histories upon the Metallographic Structure of Electric
Wires
38. Research on First and Second Fused Mark Discrimination of Electric Wires (No. 1)
38, 39 & 41. Research on First and Second Fused Mark Discrimination of Electric Wires
39. Research on First and Second Fused Mark Discrimination of Electric Wires (No. 2) (
This has just the same contents as following No. 41.)
41. Research on First and Second Fused Mark Discrimination of Electric Wires
42. Discrimination between Primary and Secondary Ark Marks on Electric Wires by the
micro-void Distribution
43. Possibility of Carbon Inclusion in the Molten Mark of Polyvinyl Chloride Insulated
Codes Due to a Fire
46. Firing Current Range of Model Polyvinyl Chloride Covered Cord Having
Disconnected Element Wires
49. Partial Disconnection Test of New Product (Stranded Cords Used for Domestic
Plugs)
50. Why is an Electrical Cord Fixed to a Fuel Hose of a Heating Equipment Often Cut?
52. Deterioration and Firing Properties of Polyvinyl Chloride Covering Cords at Elevated
Temperature
53a. Research on thermal Phenomena of Twist Joint Point of P.V.C. Insulated Flexible
Cords
53b. Protection Behavior of MCCB for the Short-circuited Cords and VVF Cables
54. The Carbonisation and the Degree of Crystallisation of Organic Insulator due to
Electric Breakdown
55. Experiments on Dielectric Breakdown and Ignition of Phenolic Resin Used in the
Battery of DC 24V
59. Electric Ignition Phenomena Caused by Tracking Failure in Distribution Cable and
Development of Electric Fire Protection Equipment
61. Influence of the Direction of a Electric Hair Drier on Melting of its Heater
64. A Case Report of a Fire Caused by a Down-light and an Experiment for the Proof
91. Fire Hazards of Short Circuit by Arc Discharge on Carbonized Conductive Track
(Content of this report is included in No. 15.)
94. Classification of Arc Marks on Electrical Wires (Content of this report is included in
No. 42.)95. Ignition Hazard by Short Circuit between Element Wires of a Stranded Cord
96. Studies on Thermal Phenomena of Twisted Joint Point of P.V.C. Insulated Flexible
Cords (Content of this report is included in No. 53.)
129. A Case Report of a Fire Caused by a Desk Lamp with a touch Switch
130. A Case Report of a Fire Accident Started at the Wiring of a Ceramic-type Electric
Space Heater
132. Relationship of Service Entrance Direction to the Arc Signs of Short Circuits
(Content of this report is included in No. 21.)
154. Fire Causes at Electrical Wiring Devices (Fire Cases and Their Feature, Damage
Conditions and Prevention)