Frame mounted IO Basic

0 1 2 3 4 5 6 7 8 9
recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.

A
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying,

B
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.

6
4
2 3 5 7

D
1
10

8 9

1 OPTIONAL FRAME MOUNTED VIBRATION SENSOR (S10)


6 OPTIONAL COVER SWITCH SENSOR (S8)

2 OPTIONAL INLET(MD) END TEMPERATURE SENSOR (S4) 7 PINION SPEED SENSOR (S2)
F
3 OPTIONAL GB END TEMPERATURE SENSOR (S3) 8 24VDC POWER

4 BOWL SPEED SENSOR (S1) 9 ETHERNET POWERLINK

10 BASIC IO BOX ASSEMBLY


5 OPTIONAL LOAD CELL SENSOR (S7)

2
R00 inpaspla DKSOJPNA DKSOEPV 10-01-2018 Project : Page Name : Drawing No.: =
.
ALFALAVAL COPENHAGEN A/S +
. INPASPLA 05-09-2017
.
CONNECTION DIAGRAM FOR SOBORG GENERAL INTERCONNECTION 61248971
. Page No. : 1
FRAME MOUNTED IO BOX-BASIC DENMARK OVERVIEW
Rev. No. Made by Chk By Appr. By Rev. Date Made By Date Total Pages : 4
Frame mounted IO Basic

0 1 2 3 4 5 6 7 8 9
recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.

A
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying,

OPTION
ETHERNET LINK TO
CUSTOMER (S/FTP CAT5)

B
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.

CONTROL PANEL
C HMI

PANEL RESET
LIVE

EM.STOP

D USB

-42W1 POWER BACK DRIVE MOTOR (3T1,3T2,3T3,GND)

-42W8 THERMISTORS (BT1,BT2)

E +P11
+P2 -44W1 POWER GREASE PUMP (230L1,0VAC,GND)

Basic ETHERNET TO CUSTOMER (S/FTP CAT5)


MOUNTED IO BOX IO BOX
61248604-80 ETHERNET POWERLINK TO CORE CONTROLLER

+P35 24VDC POWER (+24VDC, 0VDC)

F -41W1 POWER MAIN DRIVE MOTOR(2T1,2T2,2T3,GND)


-41W8 THERMISTORS (MT1, MT2)

(L1,L2,L3,PE)
FROM CUSTOMER
POWER SUPPLY

1 Note : Control panel considered as Generic Panel 4


R00 inpaspla DKSOJPNA DKSOEPV 10-01-2018 Project : Page Name : Drawing No.: =
.
ALFALAVAL COPENHAGEN A/S +
. INPASPLA 05-09-2017
.
CONNECTION DIAGRAM FOR SOBORG GENERAL OVERVIEW 61248971
. Page No. : 2
Rev. No. Made by Chk By Appr. By Rev. Date Made By Date
FRAME MOUNTED IO BOX-BASIC DENMARK Total Pages : 4
Frame mounted IO Basic

0 1 2 3 4 5 6 7 8 9

-10X12 -10X13
recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.

A
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying,

+24V
1515
1411/1112

1421

1211
1311

1312

1321

1322

1513

1212

1221(+24VDC)
1511

1514

1222

0VDC

PE
1613
1611
-104A1
X5
1 2 PE 10/100Base-T(X)

10/100Base-T(X)

BN WH BU BK BN WH BU BK WH BK WH BK BN WH BK BN WH BK RD GN WH BK OG BN WH BU BK GY BN WH RD GN WH BK
B 1 2 3 4 1 2 3 4 2 4 2 4 1 2 4 1 2 4 1 2 3 4 5 1 2 1 2 3 4 5
BASIC IO BOX
1 2 3 4 5
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.

X1 X2 X3 X4 X5 X6 X7 X8 X9 X10

W1 W2 W3 W4 W7 W8 W9 W10

1 2 3 4 1 2 3 4 2 4 2 4 1 2 3 4 1 2 3 4 1 2 1 2 3 4

E
S1 S2 S3 S4 S7 S8 S9 S10

BOWL PINION GB END INLET (MD) END LOAD OPTIONAL OPTIONAL OPTIONAL
SPEED SPEED BEARING BEARING CELL DECANTER GREASE LEVEL FRAME
SENSOR SENSOR TEMPERATURE TEMPERATURE BD TORQUE COVER SWITCH VIBRATION
SENSOR SENSOR SENSOR SWITCH SENSOR

Note : -104A1 Terminal details on next page


2 6
R00 inpaspla DKSOJPNA DKSOEPV 10-01-2018 Project : Page Name : Drawing No.: =
.
ALFALAVAL COPENHAGEN A/S +
. INPASPLA 05-09-2017
.
CONNECTION DIAGRAM FOR SOBORG Basic IO Box 61248971
. Page No. : 4
Rev. No. Made by Chk By Appr. By Rev. Date Made By Date
FRAME MOUNTED IO BOX-BASIC DENMARK Total Pages : 4
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.

F
E
B

C
A

G
D

4
R00

Rev. No.
0

inpaspla
Frame mounted IO Basic

Made by
.
.

Chk By
.
.

Appr. By
DKSOJPNA DKSOEPV
1

Rev. Date
10-01-2018

Made By
INPASPLA
2

Date
05-09-2017
-104A1

Project :
8
1
3

‎1MΩ

CONNECTION DIAGRAM FOR


FRAME MOUNTED IO BOX-BASIC
4

1nF
5

SOBORG
DENMARK
ALFALAVAL COPENHAGEN A/S
6

8
7
5
4
6
3
2
1

Page Name :
7

Ethernet Connection
8

Drawing No.:

61248971
+
=
9

Page No. :
Total Pages :
6