You are on page 1of 9

Detail Specification Sheet for Approval

Customer: Comptronic AB

Product Name: Piezoelectric Transducer

Part Number: PE42300-P030C1-A

Explanation: 42mm dia. Piezo transducer without oscillator, 3KHz,

with PBT case and high temp. resisted piezo element

APPROVED BY APPROVED BY
GCI Components Limited

------------------------------------ ----------------------------------

DATE : DATE : Sep 22, 2020

1/9
CONTENTS

1 Purpose
2 Maximum Rating
3 Dimensions & Construction
4 Electrical Characteristics
5 Method of Measurement
6 Quality Control
7 Packing
8 Related Explanation
9 Appendix

2/9
1 Purpose
This document contains the detail specifications (electrical and mechanical), inspection

standard and the reliability standard for the purpose of the customer’s approval.

2 Maximum Rating
See Table 1.

No. Item Specification

2.1 Maximum Input Voltage 60Vp-p Square Ware

2.2 Operating Temperature -20 ºC~+70 ºC

2.3 Storage Temperature -30 ºC~+80 ºC

2.4 Hand Soldering Temperature 350 ºC within 5 Seconds

256 ºC within 3 Seconds


2.5 Wave Soldering Temperature
350 ºC within 1 Seconds

2.6 Short-term Exposed High Temperature 115 ºC Max. within 3 Hours

Table 1

3 Dimensions & Construction

3.1 Dimensions

See the attached relevant drawing, all dimensions are in mm

3/9
3.2 Inspection standard

See Table 2.

Table 2
Inspection By Means
No. Item Specification Remark
Of

3.2.1 Outer Diameter Φ41.5±0.5 Vernier Caliper

3.2.2 Overall Height 16.2±0.5 Vernier Caliper

Pin Length from


3.2.3 the bottom edge 3.0+0.3 Vernier Caliper
of the housing
Any rust should not be
3.2.4 Rust Eye
accepted
There should be no
3.2.5 Stain Eye
remarkable stains

Adhesive should be
made sufficiently and there
3.2.6 Adhesive Eye
should be no outflow of
adhesive.

3.2.7 Other Appearance Eye

4 Electrical Characteristics
4.1 Electrical-acoustic Characteristics

See Table 3.

Table 3
No. Item Specification
114dB±4db at 10cm/3000Hz/
4.1.1 Sound Press Level (SPL)
18.0Vp-p Square Wave
4.1.2 Operating Frequency 3.0 ±0.3 kHz

4.1.3 Capacitance 42nF ±30% at 120Hz

4.1.4 Operating Voltage 18.0 Vp-p Square Wave

4/9
4.2 Frequency Response Curve

18.0 Vp-p Square Wave / 10cm

5 Method of Measurement
5.1 Measuring Condition

Normal measuring condition is used unless the standard condition is required. See Table 4.

Table 4

Normal measuring condition Standard measuring condition

Temperature = +15℃ to +35℃, Temperature = +25±3℃,


Humidity = 35% to 85% R.H. Humidity = 35%±10% R.H.

5/9
5.2 SPL Measure Method

See attached relevant drawing.

6 Quality Control
6.1 Outgoing Inspection

Use GB 2828-87 (or MIL-STD-105) as the AQL sampling plans. See Table 5.

Table 5

Item Inspection Level AQL%

Figuration & Dimension S-3 1.0

Appearance II 1.5

No Sound II 0.25

Low Sound Press Level II 0.4

Capacitance II 0.65

Package S-3 1.0

6/9
6.2 Life Test

Normal Condition:

Test Condition: 12Vp-p Square Wave / 3000Hz

Duration Time: 500 hours

After the test, all of the electric performance must meet the requirement of table 3.

6.3 Environmental Test

The sample should be arranged into three groups and kept in normal condition for 2hrs

before experiment. See Table 6-1~6-3.

Table 6-1
Sample
No Item Test Condition Requirement
Size

1 HIGH TEMP. +90℃±2℃ for 96 hrs

2 LOW TEMP. -40℃±3℃ for 96 hrs All of the


performance
must meet the
Temperature Period
requirements on 5pcs each
table 2 and table
TEMP CYCLE -20±3℃ 30 min
3 after
(5 cycles totally) +20±3℃ 15min
3 experiment.
Without applying +70±3℃ 30 min
power +20±3℃ 15min
Transfer time < 10s
1 Cycle

7/9
Table 6-2
ITEM Test Condition Requirement Sample
No
Size

All of the
performance
must meet the
+40±2℃& 90%~95% RH
1 HUMIDITY requirements on 5pcs
for 96 hrs
table 2 and table
3 after
experiment.

Table 6-3
ITEM Test Condition Requirement Sample
No
Size

Sweep Range: 10~55~10 Hz


Vibration Scope: ±1.52 mm
VIBRATION
1 Sweep Time: 1.0 minutes
Total test time: 30 minutes

All of the
With the gravity of 100g at axial of performance
STRIKE
2 X/Y/Z for 6 times per direction. must meet the
5pcs each
requirements on
Drop a buzzer naturally from the table 2 and table
height of 700mm onto the surface of 3 after
DROP 10mm thick wooden board. Two experiment.
3 directions; that is, upper and side of
the buzzer are to be applied for this
drop test. 5times for each side.

6.4 Extra Test

a. Life test Under Extreme High Voltage:

Test Condition: 110.0Vp-p Square Wave / 3000Hz

Duration Time: 48 hours

b. Extreme High Temperature Test:

Test Condition: +115℃±2℃

Duration Time: 4Hours

8/9
7 Packing
Attaching Photo: N/A

Detail:

20pcs in one layer (put buzzers on the foam board tightly)

2 Layer, 40pcs in one Box

8Box, 320pcs in one Carton

Carton Size: 43 x 22 x28(cm)

Gross Weight per Carton: 5.4Kg

8 Related Explanation
N/A

9 Appendix
N/A

9/9

You might also like