1. Features:
DC 12V;
Relay channels: 2 ;
With Momentary function, you can use the command to operate the relay to open
2. product function
parallel;
Support the manual control of the upper computer software (the upper computer
Support self-locking mode (reverse the relay status, if the relay NO is engaged
with COM, send this command to disconnect NO from COM, and vice versa);
Support jog mode (pull in relay NO and COM, then disconnect after 0.6S);
disconnected);
Support delay mode (pull in relay NO with COM, and disconnected after nS), n
can be set;
The default baud rate is 9600BPS, and the baud rate can be selected to 1200
Relay 10A/250VAC,10A/125AC,10A/30VDC,10A28VDC
specifications
Data interface RS485
indication
indication
size 60*35*19mm
weight 32g
4. interface description
2. Relay wiring:
3. RS485 connection:
4. Power wiring:
5. Instructions for instruction
Example: Connect to PC via USB to RS485 module, open the serial port
debugging assistant, select the corresponding port, select the baud rate
9600, no parity, 8 data bits, 1 stop bit, as shown in the figure.
If you want to open all the relays, send the command 01 06 00 70 00
FF C8 51, 01 is the device address, 06 is the function code, 0070 is the
register address, 00FF means to open all the relays, the effect of sending
the command is as follows.
The serial port returns 01 06 00 70 00 FF C8 51. The return is the
same as sending, indicating that it is received correctly, and all relays
have been turned on. At this time, it can be observed that all the relay