Data Center Infrastructure

Who We Are
Rosenberger Hochfrequenztechnik GmbH & Co. was founded in Germany in 1958 and ranks
among the leading manufacturers of high-speed interconnect solutions worldwide. With its long
tradition of excellence and innovation, Rosenberger has excelled and earned an outstanding
reputation all over the world.

In early 2022 the Rosenberger Group announced the spinoff of its antenna and coverage
solution product portfolio with a new brand entity PROSE. The strategic focus of PROSE will
be on the development of base station antennas, microwave antennas, indoor and outdoor
coverage solutions, Open RAN sub-systems, data center, cabling system, IoT solutions, vehicle
components and related services.

As an independent entity, PROSE, with its lean, agile, and decentralized organizational
structure, will be better placed to serve global customers and manage growth by bringing
new technologies and solutions, aligned with the changing needs of customers in the telecom
industry. The PROSE product portfolio will uphold Rosenberger’s tradition of the highest
innovation and quality while delivering improved technology expertise and enhanced local
customer support around the globe.

PROSE consists of more than 3500 people, with 40+ subsidiaries sales/service offices, 4
factories, and 7 R&D centers covering mainly North America, Europe, the Middle East, Africa,
and Asia. It will continue to serve more than 100 operators/service providers worldwide
including a wide set of customized solutions for 5G deployments.

PROSE is an ISO 9001 quality system and ISO 14001 environmental system certified company.
Equipped with advanced machinery, automatically assembly, and testing centers supported by
a large group of more than 300 R&D engineers, state-of-the-art production assembly lines, and
stringent product and quality control.

PROSE’s reliability and competitiveness are the cornerstones of this sustainable growth, which
have resulted in long-term partnerships with most of the leading companies in their respective
industries. PROSE will continue to provide excellent product solutions and services for its
customers around the world.

A
B C D

A: Suzhou, China
B: Pune, India
C: New Jersey, USA
D: New South Wales, Australia
Mission
• Customer always comes first
• Drive innovation together with and for our customers
• Maintain a secure, humane and happy environment for our employees
• Develop our employees by investing in their education
• Take social responsibility
• Protect our environment with ecologically friendly products, production and
processes

Core Value
• Value Innovation
• Customer Focus
• Sustainable Growth
• Social Responsibility
Products & Services

Automatic Infrastructure Management System


Building Cabling System
Data Center Cabling System
Digital World Products
Edge Computing Data Center
Modular Data Center
MDC Cloud Management Platform

Multi-Band Antennas
Multi-Beam Hybrid Antennas
FDD+TDD Hybrid Antennas
BTS Antennas
Small Cell Antennas
5G Massive MIMO Antennas
TDD Beamforming Antennas

Active DAS Products


Tetra DAS Products
Wireless Repeater
Network Systems
Passive DAS Products
Site RF Components
In-Cabinet RF Components

Class 3 Series
Class 4 Series
Microwave Products E-Band Series
Dual-Band Series
Microwave Components

Single-Band Portfolios
Multi-Band Portfolios
O-RAN Radios
Beamforming Portfolios
Massive MIMO Portfolios

Feeder System
Power System
Fiber Solution
Archer Site Accessories
Hybrid Cable Solution
Camouflaged Antennas
Other SISO Accessories

Vehicle Antennas
Vehicle Components
Vehicle Sensors
Contents
Khipu™ Micro Data Center 6
MDC System Introduction 7
Power Distribution Box 9
Inverter Precision Air Conditioning 10
UPS (Uninterrupted Power Supply) 11
Dynamic Environment Monitoring System 12
Battery Pack 13
PDU (Power Distribution Unit) 13
Integrative Door Lock 14
Server-Rack Automatic Fire Suppression System (Option) 14

Khipu™ Micro Modular Data Center 16


Micro Modular Data Center System Introduction 17
Server Cabinet 19
Power Distribution Unit 21
Cooling Channel Product 22
Power Distribution Unit 27
UPS (Uninterrupted Power Supply) 28
Battery 30
Air Cooling 31
Dynamic Environment Monitoring System 33
Cloud Management Platform 38
Khipu™ Micro Data Center

• MDC System Introduction


• Power Distribution Box
• Inverter Precision Air Conditioning
• UPS (Uninterrupted Power Supply)
• Dynamic Environment Monitoring System
• Battery Pack
• PDU (Power Distribution Unit)
• Integrative Door Lock
• Server-Rack Automatic Fire Suppression System(Option)

PROSE Technologies | www.ProseTechnologies.com 6


MDC System Introduction

Product Introduction

From Germany and adhering to German quality, committed to providing customers with professional data center infrastructure solutions. The integrated
smart cabinet data center infrastructure solution transforms data center infrastructure construction into customized products. The integrated design
integrates the power supply and distribution system, refrigeration system, cabinet system, fire control system, dynamic monitoring system, and security
system, saving room space. IT devices such as servers, KVM, routers, and switches can be installed.

Application

Weak current room, monitoring room and small data room in government, finance, industry, communication, transportation, power energy, medical care,
education, Internet, and other industries. The room area is no more than 40 square meters.

Single cabinet Dual cabinet Triplex cabinet Quadruple cabinet

Five joint cabinet Six joint cabinet Eight joint cabinet

Certification System

Data center products strictly implement the


national and relevant industry standards,
through the corresponding national quality
management system, Theil certification, CE
certification and other authoritative certification,
with excellent quality and perfect service for
most users affirmed.

7 PROSE Technologies | www.ProseTechnologies.com


Features of Khipu™ Micro Data Center

• AC Energy Saving 30% • System Emergency Response Protection

• PUE Less Than 1.5 • Biometrics Authentication

Energy Safety

• Saving Room Space 40% • Lower Investment by 25%

• Quiet Operation Less-than 58dB • Fast Installation Only 2H

• Cascading Available for Rack


Environment Cost

• DCIM 24H Cloud O&M

• Local and Remote Alarm Modes are Available

Smart

System Specification

The cabinet dimensions can be customized as required, 1 to 10 pcs of racks can be put in cascade configuration.

Dynamic environment monitoring system Server-rack automatic fire suppression system(option)

Intelligent PDU Power Distribution Box

Battery pack
Intelligent door lock

Rack-mounted UPS Inverter precision air conditioning

PROSE Technologies | www.ProseTechnologies.com 8


Item Standard Cabinet
Height unit (customizable) 27U 42U

Cabinet size (mm) 600(800) (W) × 1200(D) × 1340(H) 600(800) (W) × 1200(D) × 2050(H)

Weight About 150kg About 180kg

Static load Up to 1800kg Up to 2000kg

Color Black or Gray

Structure composition Welding framework, cabinet seal design as a whole

Meet standard ANSI/EIA RS-310-D, IEC297-2, DIN41491, DIN41494, GB/T3047-2003

IP level IP5X

Display panel 10.1” Touch Panel LCD

Display languages English / Chinese

LED lighting BI-Color (Red & Blue)

Front door Toughened glass door with mechanical lock or fingerprint lock (Support face detector)

Rear door Enclosed steel door

Safety standard RoHS

Power Distribution Box

No. Parameter Value


1 Input rated voltage(V) 110VAC 220VAC 380VAC

2 Input rated current(A) 32A~80A 32A~80A 32A~100A

3 Input switch 32A~80A /1P 32A~80A /1P 32A~100A/3P

4 Output switch 3 × 32A/1P+16A/1P × 4 3 × 32A/1P+16A/1P × 4 7 × 32A/1P+16A/1P × 12

5 Lightning protection level Class C lightning protection

6 Dimensions(mm) W × D × H, 483 × 750 × 3U W × D × H, 483 × 750 × 9U

7 Color Black, off-white or according to customer's specification

8 Ways to enter and exit Top-in and top-out or according to customer's designation

9 Installation 19" Rack mounted

10 Cooling Natural cooling

9 PROSE Technologies | www.ProseTechnologies.com


Inverter Precision Air Conditioning

Rack-Type Air Condition Technical Specification


Type 3.5KW 6.5KW 12.5KW

Cooling Cooling capacity 3.6 6.7 12.6


Capacity Sensible heat ratio(SHR) 98% 98% 98%

Machine air volume (m³/h) 1540 2500

Energy efficiency ratio (EER) 3.36 3.22 3.10

Qty (PC) 1
Compressor
Type Enclosed inverter compressor

Fans type Hypokinesis EC centrifugal fan

Expansion valve type Electronic expansion valve

Air supply mode Upper, left, right and three side air supply

Evaporator Copper pipe + Hydrophilic fin

Freezing medium R410A

Unit standard heating (W) 500 1000 2000

Input 220V/50Hz(110V/60Hz) 220V/50Hz(110V/60Hz) 220V/50Hz(110V/60Hz)


Power
Electric power supplying parameters FLA(A) 7.8(16) 15(30) 22(44)
parameter
Recommended air switch model 16A(32A) 25A(50A) 32A(63A)

Self-draining pipe (mm) Inner p14Outer p18 Inner p14Outer p18 Inner p14Outer p18

Strong-Draining pipe (mm) Inner p5/Outer p7 Inner cp5/Outer p7 Inner p5/Outer cp7
Pipe type
Refrigerant air pipe (mm) 9.52 12.7 15.88

Refrigerant fluid pipe (mm) 6.35 9.52 9.52

Indoor machine size (mm) 440 × 700 × 217 440 × 717 × 350 440 × 717 × 440

Indoor machine weight (kg) 26 36 46

Outdoor machine size (mm) 844 × 286 × 604 882 × 396 × 803 932 × 440 × 1266

Outdoor machine weight (kg) 31 50 60

PROSE Technologies | www.ProseTechnologies.com 10


UPS (Uninterrupted Power Supply)

3-40KVA Technical Specification


Type 3KVA 6KVA 10KVA 15kVA 20kVA 25kVA 30kVA 40kVA

Capacity 2400W 4800W 8000W 13.5kw 18kw 22.5kw 27kw 36kw

46Hz~54Hz@50HzSystem
Frequency 40Hz~70Hz 40-70Hz
56Hz~64Hz@60HzSystem

Phase Single phase grounding type Single phase grounding type 3-phase+N-wire+ground wire

Output voltage 200/208/220/230/240VAC 208/220/230/240VAC 380/400/415VAC (Line Voltage)

Ambient temperature<35° C:

105% to 110%: UPS


automatically shut down
after 10 minutes in battery
mode

110% to 130%: UPS


automatically shut down
110%, Bypass after 1 hour;
after 1 minute in battery 100%~110%:30 min;
125%, Bypass after 10 min;
Overload mode 110%~130%:5 min:
150%, Bypass after 1 min;
>130%:10 seconds
150%, Bypass after 200ms
>130%:
UPS automatically shut
down after 3 seconds in
battery mode

In addition to the above, the


UPS may switch to bypass
mode when the input is
normal.

Battery voltage 96VDC 192VDC--240VDC ±240VDC(32~44 PCS Adjust)


485 × 723 ×
Size(W × D × H) mm 410 × 438 × 88[2U] 530 × 438 × 88[2U] 580 × 438 × 133[3U] 485 × 790 × 130
174
Weight(kg) 14.2 13 17 25 30 41

Noise(dB) <50dB@1 Meter <55dB@1 Meter <58dB@1 Meter 65dB@100% Load, 62dB@45% Load

Operating altitude <1000m

Interface RS-232 or RS-485 RS-485

Operation temperature 0-40°C

Storage temperature -40°C~70°C

Relative humidity 0-95% (Noncondensing)

11 PROSE Technologies | www.ProseTechnologies.com


Dynamic Environment Monitoring System

Item Technical Specification


CPU ARM Cortex A9 Quad-core, Max Frequency 1.2GHz

Operating system Android 5.1

Memory DDR3L 2GB

Flash rom 8GB eMMC Flash

Standard serial port 2 Ports RS232

Standard serial port 2 Ports RS485

Debug port 1 Port Micro USB

Digital input port 2 Ports DI

Digital output port 2 Ports DO (for relay control)

USB port 3 Ports (1 Port USB Host, 2 Ports USB Device)

Debug port 1 Port Micro USB

Output supply 6 Ports 12V/1A

Wireless Reserved for 3G, 4G and Wi-Fi module expansion slot

Ethernet 1 Port RJ45 10M/100M/1000M

Operating voltage 12V DC

Max power 35W

Size 260 mm× 173 mm× 45 mm

ESD level Contact: 8KV; Air: 15KV

MTBF ≥100000H

Operating temperature -20~60°C

Operating humidity 10%~90%RH

PROSE Technologies | www.ProseTechnologies.com 12


Battery Pack

Cabinet Power Backup Time Battery Type Quantity


3KVA 15 mins 3U Battery Pack (16pcs 9AH) 1set

6KVA 15 mins 3U Battery Pack (16pcs 9AH) 2set

10KVA 15 mins 3U Battery Pack (16pcs 9AH) 3set

15KVA 15 mins 5U Battery Pack (8pcs 38AH) 4set

20KVA 15 mins 5U Battery Pack (8pcs 38AH) 4set

25KVA 15 mins 5U Battery Pack (8pcs 24AH) 8set

30KVA 15 mins 5U Battery Pack (10pcs 24AH) 8set

40KVA 15 mins 5U Battery Pack (4pcs 65AH) 10set

Note: The backup time can be customized

PDU (Power Distribution Unit)

Item Specification
Rated current 16A 32A 63A

Rated voltage 110VAC/220VAC 50/60Hz 220VAC 50/60Hz 220VAC 50/60Hz

Output ports 8/12/16/20/24

Max power 5KW 10KW 15KW

Outline size 1217(Adjustable length) × 44 × 44 mm

Installation method Horizontal/Vertical installation

Safety certification UL/CE/CCC

Function Lightning protection, intelligent monitoring, and general circuit breaker are optional

13 PROSE Technologies | www.ProseTechnologies.com


Integrative Door Lock

Type of Device Specification


Rated operating voltage DC12V

Working current Static standby: <250mA Dynamic Electronically Controlled Unlocking: <500mA

Communication mode RS485, 9600bit/s

Service life Above 500,000 times

Color Black

Operating temperature/humidity -20°C ~50°C / 20°C90%

Storage temperature/humidity -30°C ~60°C / 20°C90%

IP rate IP65
Remote unlocking by monitoring host control software Authorized card writes the card number and swipes card
3 unlock modes
to unlock key unlock
Access control authorization 500 to 5000 fingerprints

Authorized entrance number Up to 5000

Software authorization Authorized by system software through network Communication

Event records Up to 1120 history records

Function Mechanical unlocking, password of the IC card, fingerprint and so on, can be paired with

Communication interface RS485 networking real-time monitoring, door status, handle status, real-time clock function

Server-Rack Automatic Fire Suppression System (Option)

Product Parameter Value


Model number JJQR-Q-W/C-4/1.2-WL/ZZ YF4C-W/1.2-N-Y-WL/ZZ

Control the number of cabinets Less than 4 set A maximum of five cabinets are configured

Size 483(W) × 700(D) × 2U(H)mm 483(W) × 700(D) × 2U(H)mm

Fire extinguishing agent HFC-ea. Per fluorinated hexanone

Storage pressure(20°C) 1.2MPa 1.2MPa

Injection time ≤10S ≤10S

Action temperature of fire detecting tube 170 °C ±10 °C 170 °C ±10 °C

Max. Length of fire detection tube 5m for each cabinet

PROSE Technologies | www.ProseTechnologies.com 14


Ordering Information

MDC-XX XX-XX XX-XX XX-XX X X


① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨

① Cabinet Type and Quantity ② UPS Capacity and Quantity


1: 27U × 600mm × 1200, Black 1: Single cabinet 0: Without UPS 0: 0ea
2: 27U × 600mm × 1200, Black 2: Dual cabinet 1: Rack type 3KVA 1: 1ea
3: 27U × 600mm × 1200, Gray 3: Triplex cabinet 2: Rack type 6KVA 2: 2ea
4: 27U × 800mm × 1200, Gray 4: Quadruple cabinet 3: Rack type 10KVA
5: 42U × 600mm × 1200, Black 5: Five joint cabinet 4: Rack type 15KVA
6: 42U × 800mm × 1200, Black 6: Six joint cabinet 5: Rack type 20KVA
7: 42U × 600mm × 1200, Gray 7: Seven joint cabinet 6: Rack type 25KVA
8: 42U × 800mm × 1200, Gray 8: Eight joint cabinet 7: Rack type 30KVA
9: 42U × 600mm × 800, Black 9: Nine joint cabinet 8: Rack type 40KVA
A: 27U × 600mm × 800, Black A: Ten joint cabinet

③ Uninterrupted Power Supply Time and Battery storage mode ④ Type of Precision Air Conditioning and Quantity
0: Without battery 1: Battery Pack 1: Rack type 3.5kW air conditioning 0: 0ea
1: 15 minutes 2: Lead-Acid Battery in cabinet 2: Rack type 6.5kW air conditioning 1: 1ea
2: 30 minutes 3: Lead-Acid Battery in rack 3: Rack type 12.5kW air conditioning 2: 2ea
3: 60 minutes 4: Row rooms Class 12.5KW air conditioning
4: 120 minutes 5: Natural Ventilation
6: Fans Cooling

⑤ PDU Standard and Quantity per cabinet ⑥ Dynamic environment monitoring system and Quantity
A: 12 outlet PDU, 16A, IEC 320 C13 0: 0ea 1: No display host, collects UPS, power distribution module, 0: 0ea
B: 12 outlet PDU, 16A, IEC 320 C13 Smart 1: 1ea air conditioner, water leakage, temperature and humidity, 1: 1ea
C: 24 outlet PDU, 16A, IEC 320 C13 2: 2ea smoke sensor, access control, intelligent PDU, 2: 2ea
D: 24 outlet PDU, 16A, IEC 320 C13 Smart and northbound interface
E: 24 outlet PDU, 32A, IEC 320 20 × C13+4 × C19
F: 24 outlet PDU, 32A, IEC 320 20 × C13+4 × C19 Smart 2: No display host, collect UPS, power distribution module, air
G: 24 outlet PDU, 16A, IEC 320 20 × C13+4 × C19 conditioner, water leakage, temperature and humidity, smoke
H: 24 outlet PDU, 16A, IEC 320 20 × C13+4 × C19 Smart sensor, and northbound interface
J: 24 outlet PDU, 32A, IEC 320 C13
K: 24 outlet PDU, 32A, IEC 320 C13 Smart 3: Monitors the integrated screen, collecting the UPS, power
L: 24 outlet PDU, 32A, IEC 320 C19 distribution module, air conditioner, water leakage, temperature
M: 24 outlet PDU, 32A, IEC 320 C19 Smart and humidity, smoke sensor, access control, intelligent PDU,
N: 24 outlet PDU, 32A, IEC 320 18 × C13+6 × C19 and northbound interface
O: 24 outlet PDU, 32A, IEC 320 18 × C13+6 × C19 Smart
P: 12 outlet PDU, 32A, IEC 320 9 × C13+3 × C19 4: Monitors the integrated screen, collecting the UPS, power
Q: 12 outlet PDU, 32A, IEC 320 9 × C13+3 × C19 Smart distribution module, air conditioner, water leakage, temperature
R: 8 outlet PDU, 16A, GB port, with surge protection module and humidity, smoke sensor, and northbound interface
S: 24 outlet PDU, 63A, IEC 320 24 × C13

⑦ Server-rack fire suppression unit and Quantity ⑧ Lock Type


0: None fire suppression unit 0: 0 set 0: No Lock
1: Four cabinets can be detected, but only one cabinet can be 1: 1 set 1: Mechanical lock
detected at a time 2: 2 set 2: Intelligent lock with keypad
2: One fire suppression unit controls five cabinet 3: 3 set 3: Intelligent lock with Fingerprint
4: 4 set 4: Intelligent lock with IC card
5: 5 set 5: Intelligent lock with Keypad +Fingerprint
6: Intelligent lock with Keypad + IC card
7: Intelligent lock with Keypad + IC card +Fingerprint
⑨ Quantity of PDB 8: Intelligent lock and face detect with keypad
9: Intelligent lock and face detect with Fingerprint
1: 1ea A: Intelligent lock and face detect with IC card lock
2: 2ea B: Intelligent lock and face detect with Keypad +Fingerprint
C: Intelligent lock and face detect with Keypad + IC card
D: Intelligent lock and face detect with Keypad+ IC card Fingerprint

15 PROSE Technologies | www.ProseTechnologies.com


Khipu™ Micro Modular Data Center

• Micro Modular Data Center System Introduction


• Server Cabinet
• PDU (Power Distribution Unit)
• Cooling Channel Product
• Power Distribution Cabinet
• UPS (Uninterrupted Power Supply)
• Battery
• Precision Air Conditioner
• Dynamic Environment Monitoring System

PROSE Technologies | www.ProseTechnologies.com 16


Micro Modular Data Center System Introduction

Product Introduction

Modular data center is to make the power distribution system, refrigeration system, dynamic environment monitoring system, fire protection system,
security system and cabinet cold aisle system into an intelligent platform, which further improves the safety, reliability, and health of equipment, and is
more green and energy-saving.

Modular infrastructure can meet the requirements of customers' special needs and usage, meet the requirements of prefabricated production of all
modular internal infrastructure and equipment, assemble, and deliver on site quickly, and truly realize the one-stop solution of rapid deployment of IT
equipment. It has the characteristics of modular integration, safety, and reliability, saving room floor space and energy, saving time, labor and worry in
installation, compatible architecture, quick and flexible deployment, intelligent monitoring, efficient and stable refrigeration, etc. It is a new generation of
intelligent micro-module data center products.

Application Scenario

It is mainly used in small and medium data center scenarios. Its simple design, strong architectural adaptability, and low requirements for computer
room floor height and renovation meet the data center deployment requirements of corporate headquarters or large branches, bank headquarters and
secondary branches, government, operators, education, medical care, energy, and other industries.

Certification System

Data center products strictly implement the


national and relevant industry standards,
through the corresponding national quality
management system, Theil certification,, CE
certification and other authoritative certification,
with excellent quality and perfect service for
most users affirmed.

17 PROSE Technologies | www.ProseTechnologies.com


User Value of Modular Data Center Products

• AC Energy Saving 30% • System Emergency Response Protection

• PUE Less Than 1.3 • Biometrics Authentication

Energy Safety

• Saving Room Space 50% • Lower Investment by 30%

• Cascading Available for Rack • Fast Installation Only 7days

Environment Cost

• DCIM 24H Cloud O&M

• Local and Remote Alarm Modes are Available

Smart

Architecture Diagram of Micro-Module System

Cabinet Cooling channel

Battery Battery Rack


Power distribution cabinet

Air conditioner between Dynamic environment


columns Rack UPS Modular UPS Vertical UPS monitoring system

PROSE Technologies | www.ProseTechnologies.com 18


Server Cabinet

Product Introduction

In order to adapt different application scenarios, PROSE provides 9-fold cold roll steel server cabinet, flagship server cabinet and Network cabinet to meet
different needs of customers in terms of cost, use space and portability.

9-fold cold roll steel server cabinet Flagship server cabinet Network Cabinet

Main Specifications
1. Rack Unit Mechanical Specifications

9-Fold Cold Roll Steel Flagship Welded Flagship Detachable Network


Item
Server Cabinet Server Cabinet Server Cabinet Cabinet
Cabinet type NCH FCH DCH TCH

Static load Up to1800kg Up to 2000kg Up to 1500kg Up to1000kg

Color Black or Gray

Compliance with EIA-310-E, IEC297-2, DIN41491; PART1, DIN41494; PART7, GB/T3047.2-92 standard;
Standard
Compatible with ETSI standard

Frame thickness(mm) 1.5mm 1.5mm 1.5mm 1.2mm

U-column thickness(mm) 2.0mm 2.0mm 2.0mm 2.0mm

Beam thickness(mm) 1.5mm 1.5mm 1.5mm 1.5mm

Thickness (mm) 1.2mm 1.2mm 1.2mm 1.2mm


Front door
Removeable Yes& Tool-Free Yes & Tool-Free Yes & Tool-Free Yes & Tool-Free

Thickness (mm) 1.2mm 1.2mm 1.2mm 1.2mm


Rear door
Removeable Yes & Tool-Free Yes & Tool-Free Yes & Tool-Free Yes & Tool-Free

Thickness (mm) 1.2mm 1.2mm 1.2mm 1.2mm

Side door Removeable Yes & Tool-Free Yes & Tool-Free Yes & Tool-Free Yes & Tool-Free

Same door left & right Yes No No Yes

Thickness (mm) 1.2mm 1.2mm 1.2mm 1.2mm


Floorboard
Removeable No Yes Yes No

Thickness (mm) 1.2mm 1.2mm 1.2mm 1.2mm


Upper shield
Removeable No Yes No

19 PROSE Technologies | www.ProseTechnologies.com


2. Rack Unit Dimensions Specifications

Item Height(U) Width(mm) Depth(mm) Height(mm) Note


1 600 TCH Only

2 800 ALL

3 42 600 1000 2000 (Without wheels) ALL

4 1100 ALL

5 1200 ALL

6 600 TCH Only

7 800 ALL

8 42 800 1000 2000 (Without wheels) ALL

9 1100 ALL

10 1200 ALL

11 600 TCH Only

12 800 ALL

13 47 600 1000 2200 (Without wheels) ALL

14 1100 ALL

15 1200 ALL

16 600 TCH Only

17 800 ALL

18 47 800 1000 2200 (Without wheels) ALL

19 1100 ALL

20 1200 ALL

PROSE Technologies | www.ProseTechnologies.com 20


Power Distribution Unit

Application

PROSE PDU (Power Distribution Unit) provides various series of specifications with different functions, installation methods and plug combinations. It can
provide suitable rack power distribution solutions for different power environments. PDU can make the power distribution in the cabinet more orderly,
reliable, safe and professional.

Standard type Intelligent type Intelligent monitoring type

Socket Type

GB1002 10A GB1002 16A IEC320 C13 IEC320 C19

USA 15A USA 20A GER 16A UK 13A

Plug Type

GB1002 10A GB1002 16A IEC320 C14 IEC320 C20

GRE 16A UK 13A USA 15A USA 20A

IEC60309 16A/32A IEC60309 32A 380V 3P+N+E

21 PROSE Technologies | www.ProseTechnologies.com


Cooling Channel Product

The working principle of the closed cold channel is to isolate the cold air supply from the hot exhaust gas and concentrate the cooling on the air inlet
of the equipment. This process is called centralized cooling. This is achieved by installing a server cabinet with the air inlet facing the cold channel. This
cold channel containment prevents mixing of hot and cold air, which means less energy is required to maintain the system at a controlled and consistent
temperature. The cold channel closure is composed of skylight, channel door, M-shaped trunking, cabinet back panel, etc.

Flip sunroof with a width of 600mm M-type wire slot Fixed glass sunroof with a width of
600mm

Fixed glass sunroof with a width of Cabinet rear baffle


300mm

Automatic sliding door Fixed steel skylight with a width of


600mm

Reference Standard

Comply with EIA-310-E, IEC297-2 and DIN41491; PART1, DIN41494; PART7, GB/T3047-2003 standard; Compatible with ETSI standard.

Components

1) Automatic Translation Door

No. Product Measurement Surface Treatment Remark

Automatic translation, aluminum alloy wrapping and


Electrostatic spray
1 Automatic Sliding Door 1200 × 2000 toughened glass,Human body induction, lifting and
plastics
fixing without underground rail.

PROSE Technologies | www.ProseTechnologies.com 22


2) Manual Translation Door

No. Product Measurement Surface Treatment Remark

Manual translation, aluminum alloy wrapping


Electrostatic spray
1 Manual Sliding Door 1200 × 2000 and toughened glass, lifting and fixing without
plastics
underground rail.

3) Manual Sliding Door

No. Product Measurement Surface Treatment Remark

Manual door opening, consisting of metal frame and


Electrostatic spray
1 Manual Sliding Door 1200 × 2000 perspective window, supports door opening limit and
plastics
automatic closing function.

23 PROSE Technologies | www.ProseTechnologies.com


4) Fixed Steel Skylight

No. Product Measurement Surface Treatment Remark

All-steel plate design, with heightening plates on both


1 600 Width fixed metal sunroof 600 × 1200 Electrostatic spray plastics
sides

All-steel plate design, with heightening plates on both


2 300 Width fixed metal sunroof 300 × 1200 Electrostatic spray plastics
sides

All-steel plate design, with heightening plates on both


3 800 Width fixed metal sunroof 800 × 1200 Electrostatic spray plastics
sides

5) Fixed Glass Skylight

No. Product Measurement Surface Treatment Remark

All-steel+glass design, with heightening plates on


1 600-Width fixed glass skylight 600 × 1200 Electrostatic spray plastics
both sides.

All-steel+glass design, with heightening plates on


2 300 Width fixed glass skylight 300 × 1200 Electrostatic spray plastics
both sides.

All-steel+glass design, with heightening plates on


3 800-Width fixed glass skylight 800 × 1200 Electrostatic spray plastics
both sides.

PROSE Technologies | www.ProseTechnologies.com 24


6) Flip Sunroof

No. Product Measurement Surface Treatment Remark

All-steel+glass design, with heightening plates on


1 600-Width single-turn glass skylight 600 × 1200 Electrostatic spray plastics
both sides.

600-Width double-turnover glass All-steel+glass design, with heightening plates on


2 600 × 1200 Electrostatic spray plastics
skylight both sides.

All-steel+glass design, with heightening plates on


3 800-Width single-turn glass skylight 800 × 1200 Electrostatic spray plastics
both sides.

800-Width double-turnover glass All-steel+glass design, with heightening plates on


4 800 × 1200 Electrostatic spray plastics
skylight both sides.

7) M-Type Wireway

No. Product Measurement Surface Treatment Remark


1 M-slot 300 × 300 Electrostatic spray plastics

2 M-slot 300 × 600 Electrostatic spray plastics

3 M-slot 300 × 800 Electrostatic spray plastics

4 Trapezoidal span bridge 300 × 600 Electrostatic spray plastics

5 Trapezoidal span bridge 300 × 800 Electrostatic spray plastics

6 Trapezoidal span bridge 300 × 1200 Electrostatic spray plastics

7 Trapezoidal span bridge 300 × 1800 Electrostatic spray plastics

25 PROSE Technologies | www.ProseTechnologies.com


8) Cabinet Rear Baffle

No. Product Measurement Surface Treatment Remark


1 Cabinet rear baffle 200 × 300 Electrostatic spray plastics

2 Cabinet rear baffle 200 × 600 Electrostatic spray plastics

3 Cabinet rear baffle 200 × 800 Electrostatic spray plastics

4 Cabinet rear baffle 300 × 300 Electrostatic spray plastics

5 Cabinet rear baffle 300 × 600 Electrostatic spray plastics

6 Cabinet rear baffle 300 × 800 Electrostatic spray plastics

PROSE Technologies | www.ProseTechnologies.com 26


Power Distribution Unit

Application

The precision column cabinet is an intelligent integrated power distribution cabinet, which mainly provides functions such as power distribution, sub-item
power consumption measurement, feeder output protection, station-level monitoring, and other functional services for servers in computer rooms, data
centers, base stations, and other places. It is used in the field of uninterruptible power supply with high requirements on power supply reliability.
The precision column cabinet conforms to GB7251 "Low-voltage switchgear", GB50054 "Low-voltage power distribution design code" and other
standards.

Application scenarios: government, finance, education, medical care, energy, enterprise, Internet, and other data center computer rooms.

Precision Column Cabinets Modular Rack-Mounted Column Cabinet

Technical Parameter
No. Parameter Precision Column Cabinets Modular Rack-Mounted Column Cabinet
1 Input rated voltage(V) 380VAC

2 Input rated current(A) 2 × (100A~630A) 2 × (100A~400A)

3 Input switch 2 × (100A~630A) /3PMCCB 2 × (100A~400A) /3PMCCB


2 × (n × 63A/321P+n × 32A/321P+n × 16A/321P+n × 2 × (n × 63A/321P+n × 32A/321P+n × 16A/321P+n
4 Output switch
10A/321P) MCB × 10A/321P) MCB
5 Lightning protection level Class C lightning protection

6 Dimensions(mm) W × D × H, according to the cabinet size W × D × H, 483 × 750 × 24U

7 Colors Black, off-white or according to customer's specification

8 Ways to enter and exit Top-in and top-out or according to customer's designation

9 Installation Vertical floor installation 19" rack mounted

10 Cooling Natural cooling

27 PROSE Technologies | www.ProseTechnologies.com


UPS (Uninterrupted Power Supply)

PROSE introduces a new generation of three in and three out high-end UPS power supply, which adopts advanced dual core DSP digital control
technology, effectively improves product performance and system reliability, and achieves higher power density integration and miniaturization.

Application

Finance, communication, security office, machine room power, network center, electronic medical equipment, industrial control equipment and other
fields.

VT Series High Frequency RTM Series High Frequency CM Series High Frequency Online
Online Vertical UPS Online Rack Modular UPS Modular UPS

Technical Parameter
VT series 3-Phase Input 3-Phase Output 10-200KVA Technical Specification
Model VT series

Rated capacity 10-30kVA 40-60kVA 80kVA 100-120kVA 160kVA 200kVA

Rated voltage 380VAC (3-phase +N)

Frequency range 40Hz-70Hz

Power factor ≥ 0.99@100% load; ≥ 0.98@50% load

Output voltage 380/400/415VAC(3-phase+N); 20/230/240VAC (single phase+N)

Power factor 0.9 (optional 1)


< 105%, long term;
< 110%, 60 minutes; 10-125% of rated load, with load for 10 minutes;
Overload capacity
> 125-150% rated load, with load for 1 minute;
> 150%, 200ms
Number of batteries Section 32 by default; 30 ~ 44 (15 ~ 22) knots (adjustable)
800 × 600 ×
Dimension depth width × height (mm) 780 × 425 × 1200 1010 × 600 × 2000
1600
Net weight (kg) 116 141 166 230 320 460

Working temperature 0 ~ 40 C (the battery life will be shortened in the environment of > 25°C)

Relative humidity 0-95% without condensation.

Altitude 1000 meters will not be derated, and every 100 meters above 1000 meters will be derated by 1%

Noise ≤ 60db (a) @ 1m ≤ 65db (a) @ 1m

Communication interface RS-232/RS-485

PROSE Technologies | www.ProseTechnologies.com 28


RTM series 3-Phase Input 3-Phase Output 20-150KVA Technical Specification
Model RTM series

Rated capacity 20KVA 30KVA 40KVA 40KVA 60KVA 80KVA 100kVA 120KVA 150kVA

Power module capacity 10KVA 15KVA 20KVA 10KVA 15KVA 20KVA 25kVA 20KVA 25KVA

Wiring mode 3-phase +N-line +PE

Rated voltage 380/400/415Vac (line voltage)

Voltage range 304Vac~478Vac (line voltage) full load; 304Vac~228Vac (line voltage) load is derated linearly from 100%~80%

Frequency range 40Hz~70Hz

Battery voltage ±192Vdc (360~528Vdc; 30~44 batteries are adjustable, 32 batteries by default)

Power factor 1

Communication interface RS232/RS485/SNMP card (option)/programmable dry contact (option)

Working environment Working temperature: 0~40°C; Relative humidity: 0~95% (no condensation)

Cabinet type 2 module frames 4 module frames 6 module frames


482.6 × 800
Machine depth × width × height (mm) 482.6 × 800 × 353 (8U) 482.6 × 800 × 531 (12U) 482.6 × 900 × 800(18U)
× 531(12U)
Module depth × width × height (mm) 440 × 690 × 86 (2U)

Altitude 1000m will not be derated, and every 100m above 1000m will be derated by 1%

Noise ≤ 60db (a) @ 1m < 58db (a) @ 1m

Machine (Kg) 35.5 37 37.5 45.5 46 47.5 47.5 72

Module (Kg) 23 23.5 25 23 23.5 25 30 25 30

CM series 3-Phase Input 3-Phase Output 80-300KVA Technical Specification


Model CM series

Rated capacity 80kVA 120kVA 140kVA 200KVA 240kVA 100kVA 175kVA 300kVA

Power module capacity 20kVA 25kVA

Wiring mode 3-phase +N-line +PE

Rated voltage 380/400/415Vac (line voltage)

Rated frequency 50/60Hz

Battery voltage ±192Vdc (360~480Vdc; 30 ~ 40 batteries are adjustable, 32 batteries by default)

Power factor 0.9

Line feeding mode Supports uplink and downlink

Communication function RS232/RS485/SNMP card (option)/programmable dry contact (option)

Working environment Working temperature: 0 ~ 40°C; Relative humidity: 0 ~ 95% (no condensation)

Noise < 60db @ 1m

Altitude 1000m without derating, > 1000m, power derating 1% for every 100m.
4Module 6 Module 7 Module 10 Module 12 Module 4 Module 7 Module 12 Module
Cabinet type
cabinet cabinet cabinet cabinet cabinet cabinet cabinet cabinet
600 × 890 × 600 × 995 × 600 × 1010 × 600 × 890 × 600 × 960 × 600 × 1010 ×
Machine depth × width × height (mm) 600 × 995 × 1600
1200 2000 2000 1200 1600 2000
Module depth × width × height (mm) 440 × 690 × 86 (2U)

Machine (Kg) 140 124 185 207 270 150 195 270

Module (Kg) 26.5 30

29 PROSE Technologies | www.ProseTechnologies.com


Battery

Lead-Acid Battery (DC12V 9Ah-200Ah)

PROSE Lead acid battery is floating charge batteries with a designed life of 10 years. It meets IEC standard. Adopt the latest AGM valve control
technology and high purity raw materials, the battery has a reliable standby life.

Application

UPS / EPS / Emergency light / Security System / Toy / Medical etc.

Technical Parameters
Rated Voltage Rated Capacity Dimensions(mm) Appr.Weight
No. Terminal Type
DC(V) AH/20HR L W H Total H (kg)
1 12 9 152 65 95 100 2.45 F2

2 12 12 152 100 97 102 3.5 F1/F2

3 12 18 181 77 167 167 5.4 F13

4 12 24 183 78 167 167 7.15 F14

5 12 26 177 167 126 126 9.08 F15

6 12 38 198 166 170 170 13.7 F3

7 12 55 229 138 210 228 15.2 F4

8 12 65 348 168 178 178 21.3 F4

9 12 75 260 168 209 214 22.5 F4

10 12 100 329 172 214 243 30 F4/F8

11 12 120 409 177 207 234 34.8 F9

12 12 150 483 170 240 240 42.4 F4/F10

13 12 200 522 240 218 244 60.6 F5/F11

14 2 100 171 72 205 210 5.6 F7

15 2 200 170 110 330 350 14.3 F7

16 2 300 171 151 330 366 20.3 F7

17 2 400 211 176 329 367 27 F7

18 2 500 241 172 330 365 32.1 F7

19 2 600 301 175 331 366 39.1 F7

20 2 800 410 176 330 365 48.1 F7

21 2 1000 475 175 327 365 64.2 F7

22 2 1200 475 175 327 365 71 F7

23 2 1500 401 351 342 378 101 F7

24 2 2000 491 351 343 383 132 F7

25 2 3000 712 353 341 382 192 F7

PROSE Technologies | www.ProseTechnologies.com 30


Air Cooling

Air cooling are efficient, energy-saving, safe and reliable, intelligent management, compact structure, and exquisite workmanship, which fully meet the
cooling needs of modern data rooms.

F Series Room-Level Air-Cooled Precision Air G Series In-Row Air-Cooled Precision Air Conditioner
Conditioner

Application

Data center computer room, communication computer room, computer room, UPS battery room and industrial control room in various industries such as
finance, government, enterprise, energy, education, medical care, Internet, etc.

Indoor AC Technical Parameters


F Series Room-Level Air- Cooled Precision Air Conditioner
Parameter Model 25KW 30KW 35KW 40KW 45KW 50KW 60KW 70KW 80KW 90KW 100KW
Parameter air
m³/h 7500 9000 10500 11500 12000 15000 18000 21000 23000 24000 25600
volume
Cooling capacity kW 26.4 31.5 36.1 38.1 45.7 52.7 62.9 72.3 76.1 91.6 100.2
Sensible cooling
kW 24.5 29.2 33.4 35.2 41.6 48.9 58.2 66.6 70.2 83.4 91.6
capacity
Electric heating kW 6 6 6 6 6 9 9 9 9 9 9
Humidification
kg/h 4.5 4.5 4.5 4.5 4.5 6.5 6.5 6.5 6.5 6.5 6.5
amount
Maximum load
A 32.12 38.20 41.05 41.05 48.97 59.74 71.92 77.60 77.60 93.44 93.44
current FLA
Width(mm) 900 900 900 900 900 1800 1800 1800 1800 1800 1800

Unit size Depth(mm) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

Height(mm) 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980

Weight kg 355 370 375 380 390 665 695 705 715 735 755

model OU-40 OU-50 OU-50 OU-50 OU-70 OU-40 OU-50 OU-50 OU-50 OU-70 OU-70
The outdoor unit
quantity 1 1 1 1 1 2 2 2 2 2 2
Dimensions of a single energy-
650 × 300 × 950
saving module (W × D × H) mm

31 PROSE Technologies | www.ProseTechnologies.com


Indoor AC Technical Parameters
G Series In-Row Air-Cooled Precision Air Conditioner
Parameter Model 25KW 40KW 50KW

Air volume m³/h 5000 8500 10500

Cooling capacity kW 25.8 40 50

Sensible cooling capacity kW 25.8 40 50

Electric heating kW 3 6

Humidification amount kg/h 1.5 3 3

Maximum load current A 28.2 40

width mm 300 600 600

Unit size depth mm 1100 1100 1200

height mm 2000 2000 2000

Weight kg 240 330 340

The outdoor unit OU-40 OU-60 OU-70

Number of outdoor units 1 1 1

Outdoor AC Technical Parameters


Parameter Model OU-40 OU-50 OU-70 OU-80
Number of fans tower 1 1 2 2

width mm 1650 1650 2010 2860

Unit size depth mm 1100 1100 1100 1100

height mm 1150 1150 1150 1150

Full load current A 2.9 4.7 5.8 5.8

Weight kg 158 168 210 256

Noise db. 60 60 62 62

PROSE Technologies | www.ProseTechnologies.com 32


Dynamic Environment Monitoring System

Dynamic Environment Monitoring System monitors and manages the running status of assets and resources in a data center and provides a
comprehensive management platform for data centers by collecting, transmitting, and managing devices. IT serves as a bridge between the equipment
room infrastructure and IT devices. IT helps O&M personnel manage data centers and improves the reliability of the equipment room and the security of
communication devices. In ordinary demand, if only do power, environmental equipment monitoring, we generally call it Dynamic environmental monitoring
system.

Alarm record Northbound interface

Alarm Lighting Remote browsing

Integrated monitoring host

Access control

Video surveillance

UPS PDB Line Air Condition Battery Humiture Smoke Sensor Leakage Sensor

Introduce

Dynamic environmental monitoring system is a centralized monitoring of power equipment and environmental variables in all kinds of computer rooms.

A set of perfect the distribution of the dynamic environment monitoring system can separate power equipment and computer room environment,
computer security monitoring objects such as signal acquisition, real-time monitoring system and equipment running status, security, recording and
processing the relevant data, detect the fault in time, and the necessary remote control, remote regulating operation, timely notify ops staff on duty to deal
with.

The purpose is to display the equipment room's few people, unattended, and centralized monitoring and maintenance management of power supply
and air conditioning and improve the reliability of the power supply system and the security of communication equipment. It provides powerful technical
support for the machine room management automation, intelligent operation and scientific decision making.

33 PROSE Technologies | www.ProseTechnologies.com


Monitoring Object Description:

Power load PUE meter Air condition load Humidity &temperature sensor

Smoke sensor

Lamp sensor

Door sensor

Leakages sensor

AFSS sensor

Battery sensor

Cable sensor

Air condition table Temperature/humidity table Alarm table

• UPS: Collect the main circuit, bypass power quality such as voltage, current, power, frequency, and other information; At the same time, the operating
state of the equipment is also monitored, such as UPS on/off state, operation mode and power supply mode, and the working state of its internal key
electrical units.

• Battery: Collect the voltage, internal resistance, temperature, and other information of a single battery. If the status reaches the warning value, it pushes
alarm information in time.

• Cabinet: Collect the doors open/close status.

• Air Condition: Collect the air supply/return air inlet temperature, compressor working status and temperature and humidity level status.

• Humidity &Temperature Sensor: Collect the humidity and temperature at cabinet, the system according to it adjust such as fans status, air
conditioning run and stop.

• Smoke Sensor: Collect ambient smoke status.

• Leakage Sensor: Collect environmental smoke Status. Place the device in a position with water leakage risk. If water leakage occurs, the device
detects and generates an alarm.

PROSE Technologies | www.ProseTechnologies.com 34


Application

Finance, government, enterprise, energy, education, medical, Internet and other industries of the data center room, communication room, computer
room, UPS battery room and industrial control room.

Monitoring Host

The integrated monitoring screen is 10.1 inch capacitive screen, with good man-machine interface and touch performance; A full set of configuration
software development tools, a new style interface; Built-in AI/DI/RS232/RS485 port; Fast data acquisition and processing; Cold aisle cabinet side
plate embedded installation, beautiful; Support sliding operation, pattern unlock, important data page encryption; A single device can manage multiple
intelligent devices and environment such as door status sensor smoke sensor and water leakage.

Item Technical Specification


CPU ARM Cortex A9 Quad-core, Max Frequency 1.2GHz

Operating system Android 5.1

Memory DDR3L 2GB

Flash rom 8GB eMMC Flash

Standard serial port 2 Ports RS232

Standard serial port 2 Ports RS485

Debug port 1 Port Micro USB

Digital input port 2 Ports DI

Digital output port 2 Ports DO (for relay control)

USB port 3 Ports (1 Port USB Host, 2 Ports USB Device)

Debug port 1 Port Micro USB

Output supply 6 Ports 12V/1A

Wireless Reserved for 3G, 4G and Wi-Fi module expansion slot

Ethernet 1 Port RJ45 10M/100M/1000M

Operating voltage 12V DC

Max power 35W

Size 260 mm× 173 mm× 45 mm

ESD level Contact: 8KV; Air: 15KV

MTBF ≥100000H

Operating temperature -20~60°C

Operating humidity 10%~90%RH

35 PROSE Technologies | www.ProseTechnologies.com


Technical Parameters of Micro Module
Micromodule Data Center
Standard: Width:3600mm; Height 2000mm/2200mm; Length:15000mm;Support other customization
Specification
requirements
Number of IT cabinets Maximum support 48 cabinets

Average power of single cabinet Standard 3-5 kw, supporting other customization requirements

Recommended installation method Steel structure base or epoxy floor


Two-way UPS, two-way commercial power, one-way commercial power and one-way UPS;Support other
Power supply support architecture
customization requirements.
Flip skylight Automatic turnover of glass skylight, supporting fire linkage control.

Intelligent Energy-saving LED lighting, supporting human body induction

Intelligent atmosphere lamp Intelligent atmosphere light, supporting alarm linkage color change.

Cabinet Size (W × D × H) 600/800 × 1200 × 2000/2200mm

Cabinet load bearing 1000KG/1500KG/2000KG

Enter UPS and battery system.


The maximum integrated UPS power distribution is 150KVA; Independent UPS can reach more than 200KVA;
UPS rated capacity
Single module 20KVA/25KVA/40KVA/50KVA; Adopt standard cabinet body.
Frequency range 40--70HZ

Input voltage range 300--460Vac

Output voltage 380/400/415VAC, 50--60Hz, 3Ph+N+PE

Input power factor ≥0.99

Output power factor 1

Battery cupboard Adopt cabinet battery cabinet with heat dissipation module.

Backup time Configure 15min, 30min or other customization according to the actual load.

Number of batteries A total of 16-40 12V lead-acid batteries can be installed in the battery cabinet unit.
Configure according to the actual UPS, and support to monitor the internal resistance, voltage and temperature
Battery monitoring
of each battery.
Into the precision column head cabinet

Input voltage range 360-415Vac

Distribution output The maximum support of input switch is 630A;

Input mode 1/2-way MCCB; PC/CB ATS

Output mode IT load power supply, air conditioning load power supply, other power load power supply, etc.

Examine Support measuring voltage, current, open state, real power, active power and electric energy;
Support main circuit overvoltage and undervoltage alarm, overcurrent alarm, frequency abnormality alarm, single-
Report an emergency
circuit power-off alarm, three-phase unbalance alarm, etc.
Interrow air conditioning

System cooling capacity 25KW/40KW

Sensible heat ratio 0.99

Internal dimensions (W × D × H) 300 × 1200 × 2000mm(25KW), 600 × 1200 × 2000mm(40KW)

Refrigerant R410A

Monitoring unit

Man-machine interface 10.1/13.3/15.6/19/21-inch touch screen


Temperature and humidity, smoke, temperature, camera, sound and light alarm, SMS alarm, water leakage
Monitoring category
monitoring, etc.
Integrated monitoring screen/standard 1U rack monitoring host, supporting UPS, air conditioner, battery and
power distribution cabinet monitoring; Support environmental monitoring such as temperature, humidity, smoke,
Monitoring collection input and output switching value; Support dual network ports and data export; Support SD card/hard disk to
expand storage capacity, support networking monitoring through northbound interface, support access control
system, video system monitoring and dual power supply expansion.

PROSE Technologies | www.ProseTechnologies.com 36


Ordering Information

MOC- XXX XX- XX XX- XX XX- XX XX


① ② ③ ④ ⑤ ⑥ ⑦ ⑧

① Cabinet Type and Quantity ③ Column header tank and Quantity


1: 600 × 1000 × 2000,42U 7: 800 × 1000 × 2000,42U 01: Single cabinet 1: Ordinary type 0: 0 set
2: 600 × 1100 × 2000,42U 8: 800 × 1100 × 2000,42U 02: Dual cabinet 2: Precision column head cabinet 1: 1 set
3: 600 × 1200 × 2000,42U 9: 800 × 1200 × 2000,42U 03: Triplex cabinet 3: Integrated UPS cabinet 2: 2 set
4: 600 × 1000 × 2200,47U A: 800 × 1000 × 2200,47U 04: Quadruple cabinet
5: 600 × 1100 × 2200,47U B: 800 × 1100 × 2200,47U … ...
6: 600 × 1200 × 2200,47U C: 800 × 1200 × 2200,47U 48: forty-eight cabinet

② Channel type
1: Single side cold passage 1: fixed skylights on both sides, inverted skylights in the middle (single opening without automatic resetting), automatic sliding doors on both
2: Two side cold passage sides of access doors, wiring slots at the top, and peripheral sealing plates at the top.
2: fixed skylight on both sides, inverted skylight in the middle (double-opening without automatic resetting), automatic sliding doors on both
sides of access doors, wiring trough at the top, and peripheral sealing plate at the top.
3: fixed skylight on both sides, inverted skylight in the middle (single opening without automatic resetting), manual sliding doors on both sides of
access doors, wiring trough at the top, and peripheral sealing plate at the top.
4: fixed skylight on both sides, inverted skylight in the middle (double-opening without automatic resetting), manual sliding doors on both sides
of access doors, wiring trough at the top, and peripheral sealing plate at the top.
5: fixed skylights on both sides, inverted skylights in the middle (single-opening without automatic resetting), double-opening revolving doors on
both sides of access doors, wiring ducts at the top, and peripheral sealing plates at the top.
6: The fixed skylight on both sides, the inverted skylight in the middle (double-opening without automatic resetting), the double-opening
revolving door on both sides of the access door, the top with wiring trough, and the top peripheral sealing plate.

④ UPS Capacity and Quantity ⑤ Uninterrupted Power Supply Time and Battery installation
0: Without UPS B: modular 300KVA 0: 0 set 0: Without battery 1: battery pack
1: modular 30KVA C: high frequency tower 30KVA 1: 1 set 1: 15 minutes 2: Battery cabinet
2: modular 40KVA D: High frequency tower 40KVA 2: 2 set 2: 30 minutes 3: Battery rack
3: Modular 50KVA E: high frequency tower 50KVA 3: 3 set 3: 60 minutes
4: Modular 60KVA F: high frequency tower 60KVA 4: 4 set 4: 120 minutes
5: Modular 80KVA G: high frequency tower 80KVA
6: Modular 90KVA H: high frequency tower 100KVA
7: Modular 100KVA I: high frequency tower 120KVA
8: Modular 120KVA J: high frequency tower 150KVA
9: Modular 150KVA K: high frequency tower 200KVA
A: modular 200KVA L: high frequency tower 300KVA

⑥ Type and quantity of air conditioner ⑦ PDU Standard and Quantity per cabinet
1: 12.5KW air-cooled air conditioner between trains 0: 0 A: 12 outlet intelligent PDU, 16A, IEC 320 C13 0: 0 set
2: 25KW air-cooled air conditioner between trains 1: 1 B: 12 outlets intelligent PDU, 16A, IEC 320 C13 Smart 1: 1 set
3: 40KW air-cooled air conditioner between trains 2: 2 C: 24 outlets intelligent PDU, 16A, IEC 320 C13 2: 2 set
4: 50KW air-cooled air conditioner between trains 3: 3 D: 24 outlets intelligent PDU, 16A, IEC 320 C13 Smart
5: Room-level 12.5KW air-cooled air conditioner 4: 4 E: 12 outlet PDU, 16A, IEC 320 C13
6: Room-level 20KW air-cooled air conditioner 6: 6 F: 12 outlet PDU, 16A, IEC 320 C13 Smart
7: Room-level 25KW air-cooled air conditioner G: 24 outlet PDU, 16A, IEC 320 C13
8: Room-level 30KW air-cooled air conditioner H: 24 outlet PDU, 16A, IEC 320 C13 Smart
9: Room-level 35KW air-cooled air conditioner I: 24 outlet PDU, 32A, IEC 320 20 × C13+4 × C19
A: Room-level 40KW air-cooled air conditioner J: 24 outlet PDU, 32A, IEC 320 20 × C13+4 × C19 Smart
B: Room-level 50KW air-cooled air conditioner K: 24 outlet PDU, 16A, IEC 320 20 × C13+4 × C19
C: Room-level 60KW air-cooled air conditioner L: 24 outlet PDU, 16A, IEC 320 20 × C13+4 × C19 Smart
D: Room-level 70KW air-cooled air conditioner M: 24 outlet PDU, 32A, IEC 320 C13
E: Room-level 80KW air-cooled air conditioner N: 24 outlet PDU, 32A, IEC 320 C13 Smart
F: Room-class 90KW air-cooled air conditioner O: 24 outlet PDU, 32A, IEC 320 C19
G: Room-class 100KW air-cooled air conditioner P: 24 outlet PDU, 32A, IEC 320 C19 Smart
Q: 24 outlet PDU, 32A, IEC 320 18 × C13+6 × C19
R: 24 outlet PDU, 32A, IEC 320 18 × C13+6 × C19 Smart
S: 12 outlet PDU, 32A, IEC 320 9 × C13+3 × C19

⑧ Dynamic environment monitoring system and Quantity


1: No display host, collects UPS, power distribution module, air conditioner, water leakage, temperature and humidity, smoke sensor, access 0: None
control, intelligent PDU, and northbound interface 1: 1ea
2: 2ea
2: No display host, collect UPS, power distribution module, air conditioner, water leakage, temperature and humidity, smoke sensor, and
northbound interface
3: Monitors the integrated screen, collecting the UPS, power distribution module, air conditioner, water leakage, temperature and humidity, smoke
sensor, access control, intelligent PDU, and northbound interface
4: Monitors the integrated screen, collecting the UPS, power distribution module, air conditioner, water leakage, temperature and humidity, smoke
sensor, and northbound interface

37 PROSE Technologies | www.ProseTechnologies.com


Cloud Management Platform

Cloud management platform, mainly used for centralized management, control, maintenance and data analysis of second-generation intelligent cabinets
independently developed by PROSE. Relying on modern big data platform and Internet of Things system, we provide first-class products and services to
global customers. The system has the following characteristics and advantages:

Centralized management:
• Convenient operational management, can greatly enhance the work efficiency of IT management personnel, and the information management of the
enterprise:
Remote maintenance and diagnosis:
• Real-time detect the running state of cabinets, grasps each cabinet, cooling, energy consumption, to ensure the safety of assets;
• To the remote host software upgrade, remain the state of the optimal starting cabinet various performance indicators;
Fault warning:
• On potential risk early warning, and may through SMS, E-mail, real-time APP will alarm information to the equipment administrator, avoid the user
property losses;
Big data trend analysis:
• Support export all kinds of intelligence reports, in conformity with the IT standard for IT management personnel planning data center construction,
expansion to provide data basis;
Functional and practical:
• Username visualization centralized management of all site equipment status, compared with the conventional DCIM, more targeted, more convenient
operation.

System Architecture

Platform

Multimedia Screen Display

Store Monitoring Task Alarm Authority

Business Logic Web Service Restful Interface Firewall

Device Access

Site Site Site Router Web

Router Router Router

Internet

Master 1 Master 2 Master N

PDB PDB PDB

UPS UPS UPS

AC AC AC

Hygrometer Hygrometer Hygrometer

Smoke Smoke Smoke


APP
Water leakage Water leakage Water leakage

AFSS AFSS AFSS

PROSE Technologies | www.ProseTechnologies.com 38


Software Architecture

User Login Device Management User Management

Map Management Device Authority Role Management


View Layer
Statistics Overview Remote Upgrade Region Management

Alarm Management Remote Maintian

Device Access
Business Logic Alarm Process
Data Parse
Model/Presenter Layer Device Status Log Management
Data Save
Restful Interface Data Service
Send Command

Infrastructure Layer Netty Mysql Database Web Server

Hardware Layer Hardware Physical Layer

39 PROSE Technologies | www.ProseTechnologies.com


Functional Characteristics

• Support each system status display, and • Supports multiple user unlock
graphical presentation. permissions, ensuring strong security.

• Alarm status classification management, • Different permissions can be set for


convenient operations staff priority different users and the division of labor is
processing. clear.
Management Authority
• Support web and mobile APP login view,
unattended.

• Analyze historical alarm records to • No hardware investment, can run the


determine common faults. platform.

• Analyze routine detection points based on


user history data.

Analysis • Export data analysis tables for operation Low Cost


and maintenance personnel to view.

• Supports remote upgrade without personnel


duty.

Upgrade Fast

PROSE Technologies | www.ProseTechnologies.com 40


Interface Description

Login Interface

Overview

Subsystem

41 PROSE Technologies | www.ProseTechnologies.com


PROSE Service

PROSE offers professional services that improve network design, reliability,


scalability and efficiency.

Our service core competences include:


• Network optimization
• Technical consultation
• Customized product design
• Installation & commissioning
• Onsite training & supervision
• System troubleshooting
• After-sales services

In addition, we also offer professional training, technical support and workshops for distributors and agents. We are committed to
offering exceptional services for our customers.

PROSE is much more than just a supplier – PROSE is a valued development partner and we will strive to meet new challenges
in order to scale to new heights.

PROSE Technologies | www.ProseTechnologies.com 42