You are on page 1of 1

Ø90mm HDPE MAIN WATER LINE (REFER TO DRAWING WATER/CE/01)

Ø50mm HDPE
FILTER

Ø15mm

Ø15mm
CENTRIFUGAL PUMP

Cu

Cu
LADIES CHG
GENTS CHG

Ø15mm Cu
Ø15mm Cu
Ø100l SOLAR
GYSER ON DISCHARGE SKIMMER
ROOF Ø15mm Ø15mm
Cu Cu

Ø20mm Cu
Ø20mm Cu

Ø15mm Cu
Ø15mm Cu
Ø15mm

Ø15mm
Cu

Cu
Ø32mm HDPE MAIN DRAINAGE
Ø20mm Cu Ø20mm Cu
Ø25mm Cu Ø20mm Cu
32mm ISOLATING
VALVE

A
POOL DETAILS N.T.S
Ø200l SOLAR
50mm ISOLATING VALVE
SECTION A-A
GYSER ON CENTRIFUGAL
32mm ISOLATING VALVE STAND

Ø90mm HDPE MAIN WATER LINE (REFER TO DRAWING WATER/CE/01)

DISCHARGE 2
COLD ROOM 2
2 x 3x 2.4m

SKIMMER 2

Ø50mm HDPE
Ø50mm HDPE
COLD ROOM 1
2 x 3x 2.4m
Ø28mm
Cu
Ø25mm
Cu SUCTION

Ø28mm SKIMMER 3
Ø15mm Ø15mm Ø15mm Cu
LADIES
GENTS

Cu Cu Cu
Ø15mm
Ø15mm Cu
Cu

SHOP KITCHEN SWIMMING


Ø15mm Ø15mm
Cu Cu POOL
Ø28mm
Cu

Ø15mm Ø15mm Ø15mm


Cu Cu Cu Ø22mm
Ø20mm Cu TO WATERFALL DISCHARGE 1
Cu
Sanitizing Rinsing Washing

SKIMMER 1
Ø22mm
Cu Ø50mm HDPE

ENTRANCE WALKWAY Ø50mm HDPE NOTES:


PORCH · GALVANIZED MILD STEEL PIPES TO BE USED ABOVE GROUND.
· HDPE 90 PN10 PIPES TO BE BURIED IN THE GROUND AND
SHOULD NOT BE EXPOSED TO THE SUN.
A · INSTALLATION TO COMPLY WITH SAN 10 400 - T 4.6.2; SANS 400-
W AND SANS 10 252 - 1 (2012)
Ø15mm Ø15mm
Ø22mm
Cu
BAR · INSTALLATION TO BE TESTED AT 15 BARS PRIOR TO COVERING
LADIES

Cu Cu
Ø15mm Cu Ø15mm UP REFER TO SANS 10 252 - 1: 2012 EDITION 3, ITEM 9.2.2.3 (B)
Cu
Ø15mm Cu
Ø15mm
Cu GENTS
Ø15mm Ø15mm Ø15mm
Ø20mm
Cu
Cu Cu Cu LEGEND
Ø32mm Ø32mm Ø25mm
HDPE Cu Cu SYMBOL DESCRIPTION
RISER
DROPPER
10

12

13

14

15

16

17

18
11

COLD WATER PIPE


1
7
9

2
4

HOT WATER PIPE


SOLAR WATER GYSER
VALVE
CENRTIFUGAL PUMP
FILTER
SKIMMER

GROUND FLOOR PLAN


CLIENT: ARCHITECT / SURVEYOR: DRAWING NUMBER SHEET No.
NOTES: DESIGNED BY VZ CONSULTANT: CNM-YBJ OFFICE:
HARARE
1. DO NOT SCALE OFF THIS DRAWING
DESIGNED CHECKED BY VZ MUDONDO ARCHITECT 9067/ME/02 SHEET 1 OF 1
Registered Architects, Interior Designers & Planning Consultants PROJECT NAME:
CNM YBJ PROJECT NUMBER SCALE
DRAWN BY SN

C 31/05/23 SN REVISED TO SUIT INFORMATION PROVIDED BY CIVILS DEPARTMENT


DRAWING CHECKED BY VZ
HARARE OFFICE
SHANDA HOUSE
BULAWAYO OFFICE
3rd FLOOR, FIDELITY LIFE CENTRE
MTS KARIBA TIGER BAY: RESORT REDEVELOPMENT AS SHOWN
17 Park St. Shanda Hse. Tel: 252224
17 PARK STREET Cnr 11th AVE / FIFE STREET
B 12/05/23 SN SWIMMING POOL WATER RETICULATION ADDED TM CONTRACT No. DATE REV No. PAPER SIZE
A 23/02/23 SN ISSUED FOR CONSTRUCTION
APPROVED
P.0. BOX ST 523, SOUTHERTON P.0. BOX FM 254 architect P.O. Box CY 934
Harare
Cell : 0773178855/0714883472
e-mail: mtsarchitect@gmail.com
DRAWING TITLE:

MARK DATE INTIALS REVISION


SIGNATURE
DATE
...........................
JUNE 2022
TEL: (+263 242) 25224/252753/705637/706762
EMAIL: cnm@iwayafrica.co.zw
TEL: (+263 292) 75709 / 75719
EMAIL: cnmybjbyo@gmail.com
MAIN BUILDING WATER AND SOLAR GEYSER LAYOUT 2022/06/30
A0