Professional Documents
Culture Documents
(Recommendation)
TP3 45° TP10 FEED PUMP LUBE OIL RETURN DN100(4"),RF,150#,WN 304 SS
45°
A BRANC ES DISPLACEMENT
FEED PUMP (D t t o )
Nozzles on down-down
(Turbine driven BFP) FEED
DT= 160 ℃
~742
655
DX DY D
Turbine Shaft End Z
235
235
Mx
X ITO-B +1.69 +0.84 +0.84
755
755
ALLOWABLE FORCES ON BRANC ES N,N
860
Second Grouting
+tbam 1235
765 765
150
C tt or e Vert or e F ex o o e t Tor o o e t
20
Fx=Fy Fz Mx=My Mz
20
100
TP1
70
70
SUCTION 20600 38400 7500 15500
TP2 Grounding
Grounding
Grounding
DISC ARGE 65500 122000 21500 44800
475 Grounding
842
3 MAXIMUM LOAD PER BOLT (kN) 3
Rx Ry Rz
1.MASS(Dry) -11.38
2.MASS(Wet) -11.72
3.TORQUE ±2.02
300
300
2450 Rx Ry Rz
Boiler Feed Pump Suction Boiler Feed Pump Discharge Boiler Feed Pump ITO WEIGHT(DRY) WEIGHT(WET)CARTRIDGE WEIGHT
M
R
m
925 925 MOMENT INERTIA
NO LE ±14.62 ±14.42 ±48.19
KG KG KG ² KG. ²
E7018 Electrode list of pull spaces and weight for required maintenance
Butter Layer FEED PUMP 6850 7150 4050 2.84 Cartridge weight Cartridge removal spaces
Ø129.5 Pump 4050 Kg ~3400 mm
BASE PLATE 3550 - - -
CIVIL
Ø114.3 CONTRACTOR DOCUMENT REVIEW
2 AUXILIARIES 1200 1250 - -
R MECH 2
Ø80 E
LOG DATE : V ELECT
1.6 I
E
BFP Discharge
IN COMM NO : I&C
BFP Suction
+tbam
60
TOTAL 11600 11950 - - W
60
10°
°
3 7 .5
A APPROVED SUPPORT
°
550
°
37.5
3 7 .5
B APPROVED AS NOTED CONTRACTOR
14.07
10°
°
°
60
°
Detail B C NOT APPROVED RECORD
9.13
D
1.6
8.79
I
Y 1.6 TDPA: TDPB:
I INFORMATION
S
WORKING DOCUMENT
Ø257.2 T
Ø288.9 Left side from pump to turbine view Right side from pump to turbine view APPROVAL DOES NOT RELIEVE CONTRACTOR R
Ø295.2 Sulzer WBS:100241334-0010 Sulzer WBS:100241334-0010 FROM RESPONSIBILITY FOR ERROR OR I
B
1730(Baseplate Width)
I
BY DATE : O
E7018 Electrode TENACITO 65 N
+0.000m Butter Layer Electrode Butter Layer LOG DATE :
2230
600
530
X OUT COMM NO :
00 0 0 Attention :
R3 The reducers connected pump suction /discharge/ ITO are not Sulzer's scope.
63
8
8
63
2 26-JULY-2017 UPDATED FOR OWNER APPROVAL V.ZHANG L.FU D.ZOU
Suggest: Before the water pump unit is installed to the foundation, the suction, discharge
1 B 01-JULY-2017 UPDATED FOR OWNER APPROVAL V.ZHANG L.FU D.ZOU
and ITO reducers need to be welded to the pump. 0 C 12-MAY-2017 ISSUED FOR OWNER APPROVAL V.ZHANG L.FU D.ZOU
2
Earth grounding schematic
(without scale) LONTAR EXTENSION
02/2012
Bolt M10×50 General Note: COAL FIRED STEAM POWER PLANT (1X315MW)
(Copper)
Nut M10 1, All dimensions unit showed are mm ;
525 741 (Copper) Modification-According to owner's Victor Zhang Fu Lihua Daniel Zou
1
2, Minimum maintenance service spaces is more than 1.5m to nearest obstacles; h comments(2017.07.26) 1
Earth Boss 2017.07.26 2017.07.26 2017.07.26 SPEC TITLE Boiler Feed Water Pump
(SS304) 3, The Pump center elevation need according to the centerline height of turbine ;
841x1189
Modification-According to owner's Victor Zhang Fu Lihua Daniel Zou SPEC N O. 189963.67.9271
4, The revised parts see the mark symbol; g
comments(2017.06.06) 2017.07.01 2017.07.01 2017.07.01 Modify according to BV 2016.11.17 2016.11.17 2016.11.17
5, This figure signal way of lifting are only for reference, Change Language(delete chinese) Victor Zhang Fu Lihua Daniel Zou a comments(2016.11.15)
Victor Zhang Fu Lihua Daniel Zou
1950(Baseplate Length) f
final selection should be accord with local existing lifting equipment ; 2017.05.05 2017.05.05 2017.05.05 REV. MODIFICATION MODIFIED CHECKED APPROVED
Pump Base plate
6, Lifting gear are not in Sulzer scope of supply Modification-According to BV''s Victor Zhang Fu Lihua Daniel Zou SEP. PARTS LIST: - FORMAT A0 DESIGN GROUP
SULZER PUMPS SUZHOU LTD FIRST ANGLE PROJECTION
MAIN PUMP e comments(2017.01.09) REPLACED BY: - SUBSTITUTE FOR: - ORIGINAL SCALE: 1:1
2017.02.03 2017.02.03 2017.02.03
742
655
4 TP9 FEED PUMP LUBE OIL SUPPLY DN50(2"),RF,150#,WN 304 SS 4
8
63
TP9
255
255
525
525
555
555
555
PARTS LIST
720
755
775
775
ITEM QTY DESCRIPTION REMARK
660
TP9
860
1 1 Boiler Feed Pump HPT200-330/6S
2.3°
2 1 Baseplate
3 1 Guide Piece Assembly
TP10 TP5
4 1 Mechanical Seal System
TP10 5 1 Junction Box
TP7 TP6 6 1 Pressure Gauge Pan
TP5 7 1 MS Flushing Water Inlet Pipework
TP1 TP2 TP8 TP8
554 8 1 MS Flushing Water Outlet Pipework
1208 1100
3 3
4
h
8
1
TP7
7
5
TP6
10
6
9
TP8
3
14
1208
CIVIL
CONTRACTOR DOCUMENT REVIEW
2 R 2
1000
MECH
E
LOG DATE : V ELECT
I
13 IN COMM NO : E I&C
W
A APPROVED SUPPORT
605
OUT COMM NO :
915
920
CONTRACT NO : 0436.PJ/DAN.02.01/DIR/2015
TP10 TP5
LONTAR EXTENSION
1250 COAL FIRED STEAM POWER PLANT (1X315MW)
Modification-According to BV''s Victor Zhang Fu Lihua Daniel Zou SEP. PARTS LIST: - FORMAT A0 DESIGN GROUP
SULZER PUMPS SUZHOU LTD FIRST ANGLE PROJECTION
e comments(2017.01.09) REPLACED BY: - SUBSTITUTE FOR: - ORIGINAL SCALE: 1:1
2017.02.03 2017.02.03 2017.02.03
DRAWN: 2016.10.20
Modification-According to BV''s Victor Zhang Fu lihua Daniel Zou HPT OUTLINE DRAWING VICTOR ZHANG
d comments(2016.12.08
CERTIFIED FINAL DO NOT SCALE. DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED. 2016.12.15 2016.12.15 2016.12.15 200-330-6s HPT-TD Pump CHECKED: 2016.10.20
Update Revision Victor Zhang Fu Lihua Daniel Zou Fu Lihua
Lontar Extension FEED WATER PUMP
CERTIFIED FOR NOZZLE & UNLESS OTHERWISE SPECIFIED TOLERANCES c APPROVED: 2016.10.20
2016.12.01 2016.12.01 2016.12.01
FOUNDATION ONLY ANCHOR HOLES LOCATION DIMENSIONS `5 100241334 - Daniel Zou
NOZZLES LOCATION DIMENSIONS `5 Modification Victor Zhang Fu Lihua Daniel Zou
PART NO.
PRELIMINARY ONLY b
OUTLINE&AUX CONNECTION DIMENSIONS `25 2016.11.22 2016.11.22 2016.11.22 890 ZH PGA1002413340010-01 2 / 2
F E D C B A