Installation Manual
Bandak Light Weight Taut Wire
Mk 15B
Kongsberg Part no.: 702788
178539/F 1
Bandak Light Weight Taut Wire Mk15B
Document revisions
Written by Checked by Approved by
Rev.
Date Sign. Date Sign. Date Sign.
A 23.09.04 SL 25.09.04 HT 25.09.04 SL
B 30.09.05 SL 06.10.05 HT 12.10.05 SL
C 07.02.07 HHO 08.02.07 TH 08.02.07 TF
D 08.06.07 PLB 08.06.07 TH 08.06.07 TH
E 01.10.07 SEM 01.10.07 TH 02.10.07 TH
F 09.04.08 PLB 09.04.08 TH 09.04.08 TH
The original signatures are recorded on the company’s logistic data system.
Document history
Rev. A Initial Issue.
Rev. B New type of Remote Control (RC).
Rev. C Air connection type added in sections 2 and 3.5.4.
Rev. D Note added to Electrical specifications in section 2, new drawing 4-0893 Rev. B
added and drawing 3-7728 updated to Rev..B.
Rev. E Updated cable dimension for no. 11 in Table 1.
Rev. F Drawing 3-7543B replaced by 3-8049, drawing 3-7728B replaced by 3-8050,
drawings S-03205 and S-03360 removed, and drawings 3-8011A, 4-1123A, 3-8058
and 4-1133 added.
2 178539/F
Installation Manual
Table of contents
1 INTRODUCTION....................................................................................................5
2 SPECIFICATIONS..................................................................................................6
3 INSTALLATION .....................................................................................................9
3.1 General information...........................................................................................9
3.2 Location of the units ..........................................................................................9
3.2.1 Light Weight Taut Wire Unit ........................................................................9
3.2.2 Electrical Cabinet ..........................................................................................9
3.2.3 Remote Control Unit (optional)...................................................................10
3.3 Logistics ..........................................................................................................10
3.4 Handling ..........................................................................................................10
3.4.1 Light Weight Taut Wire ..............................................................................10
3.4.2 Electrical Cabinet ........................................................................................10
3.4.3 Remote Control Panel (optional).................................................................11
3.5 Mechanical installation....................................................................................11
3.5.1 Light Weight Taut Wire Unit ......................................................................11
3.5.2 Electrical Cabinet ........................................................................................11
3.5.3 Remote Control Unit (optional)...................................................................11
3.5.4 Pressurised air..............................................................................................12
3.6 Electrical installation .......................................................................................12
3.6.1 General ........................................................................................................12
3.6.1.1 PG-glands ........................................................................................... 12
3.6.1.2 Tension relief...................................................................................... 12
3.6.1.3 Recommended cables ......................................................................... 13
3.6.1.4 Cable clamping and screen/earth connections.................................... 13
3.6.1.5 Cable terminations.............................................................................. 14
3.6.2 Light Weight Taut Wire Unit ......................................................................14
3.6.2.1 Servo Motor Junction Box.................................................................. 14
3.6.2.2 Hydraulic Motor Junction Box ........................................................... 14
3.6.2.3 Taut Wire Control Unit ...................................................................... 14
3.6.3 Electrical Cabinet ........................................................................................15
3.6.4 Remote Control Unit (optional)...................................................................15
4 INSTALLATION DRAWINGS............................................................................16
178539/F 3
Bandak Light Weight Taut Wire Mk15B
4 178539/F
Installation Manual
1 INTRODUCTION
The Light Weight Taut Wire Mk 15B is a position reference
system designed for use in a deck-mounted port or starboard
position on surface vessels. The purpose of the Light Weight
Taut Wire system is to provide accurate data of the vessel's
movements, relative to a known point, in the fore/aft (along-
ship) and port/starboard (athwart-ships) directions.
WARNING The equipment includes high voltages, which means that the
possibility for getting an electrical shock is present. Before
commencing any installation work, read the guidelines for
First Aid treatment of personnel with electrical shock.
178539/F 5
Bandak Light Weight Taut Wire Mk15B
2 SPECIFICATIONS
Mechanical specifications
Light Weight Taut Wire Mk 15B:
Height: .....................3550 mm (Parked), 1665 mm (Operational)
Width: ............................................................................ 1400 mm
Depth (Length): .......1700 mm (Parked), 5115 mm (Operational)
Weight (excluding Depressor weight): .............................2200 kg
Electrical Cabinet:
Height: ........................................................................... 1900 mm
Width: .............................................................................. 800 mm
Depth: .............................................................................. 510 mm
Weight.................................................................................250 kg
Depressor:
Volume: ............................................................................. 50 dm3
Weight: ...............................................................................360 kg
Depressor (optional):
Volume: ............................................................................. 65 dm3
Weight: ...............................................................................460 kg
Drop-in Remote Control Unit (optional):
Height: ............................................................................... 74 mm
Width: .............................................................................. 132 mm
Depth (excluding connector): ............................................ 30 mm
Weight: ..............................................................................0.38 kg
6 178539/F
Installation Manual
Electrical specifications
Input voltage:
440 VAC, +20%, -27%, 3-phase, 50 to 60 Hz (50 A fuses)
Note The input voltage must be supplied from a standard Terra
Neutral net (TN-net). A 3-phase isolation transformer is
optional for an Isolated Terra net (IT-net) supply. For further
information, please contact Bandak AS.
220 VAC, single phase, 50 to 60 Hz
Power consumption:
440 VAC: 18 kW / 37 A continuous load
220 VAC: 500 W
Batteries: ......................................PLC; lithium size ½ AA, 3.6 V
Cable specifications
See Table 1 on page 13.
Air specifications
Pressure:............................. 10 bar (maximum), 6 bar (minimum)
Flow: ............................................................. 5 Nm3/h (minimum)
Purity: ..................................................... according to ISO8573-1
Solid contamination:....................................................class 5
Maximum particle size..................................... 40 μm
Maximum concentration ............................. 10 mg/m3
Water: ..........................................................................class 3
Dew point......................................................... -20 °C
Oil: ...............................................................................class 5
Maximum concentration:............................ 25 mg/m3
Connection:...............................................................GE12LR 3/8"
178539/F 7
Bandak Light Weight Taut Wire Mk15B
Environmental specification
Light Weight Taut Wire Mk 15B:
Enclosure material: ....................Surface treated and painted steel
Enclosure protection (located on open deck): ....................... IP56
Operational temperature range: ................-15 to +65 °C, no icing
Operational humidity:........... 20 to 100 % RH with condensation
Operational Wind Strength .......................................0 to 80 knots
Storage temperature range: ......................................-25 to +70 °C
Storage humidity: .............0 to 100 % RH, sealed aluminium foil
Electrical Cabinet:
Mounting plates: ..........................................................Zinc plated
Enclosure protection (indoor location): ................................. IP22
Operational temperature range (indoor location): ...... 0 to +55 °C
Operational humidity:........... 20 to 85% RH (none condensation)
Storage temperature range: ......................................... 0 to +65 °C
Storage Humidity:................. 20 to 80% RH (none condensation)
8 178539/F
Installation Manual
3 INSTALLATION
This chapter presents the procedures for installation of the Light
Weight Taut Wire Mk 15B supplied by Bandak AS.
178539/F 9
Bandak Light Weight Taut Wire Mk15B
3.3 Logistics
Safety: General safety precautions should
be followed when working
on/with Light Weight Taut Wire
Mk 15B
Personnel qualifications: Two trained mechanical workers,
and one trained electrical workers.
Min. no. of personnel: Three.
Ship location: No recommendations.
Special tools required: None.
3.4 Handling
WARNING Never, ever pass or stay, complete or partly, under any lifted
object.
10 178539/F
Installation Manual
178539/F 11
Bandak Light Weight Taut Wire Mk15B
3.6.1.1 PG-glands
For PG-glands recommended at the Electrical Cabinet, see Table
1.
For PG-glands recommended at the Light Weight Taut Wire
Unit, see Figure 11.
The following PG-glands are pre-mounted at delivery:
• PG-gland for cable number 6 which is going into the
junction box of the Hydraulic Motor at the Light Wire Taut
Wire.
• PG-glands for cable number 7 and 8 which are going into the
junction box of the Servo Motor at the Light Wire Taut Wire
Unit.
Note PG-glands that are not pre-mounted at delivery are not included
(Customer/Yard supply).
12 178539/F
Installation Manual
Caution The additional pair wise inner screens of Cable number 8 shall
be connected together at the dedicated Earth point at its
termination rack (see drawing 3-8050). The outer screen of
Cable number 8 shall as normal be terminated at its entrance
into the Electrical Cabinet.
14 178539/F
Installation Manual
178539/F 15
Bandak Light Weight Taut Wire Mk15B
4 INSTALLATION DRAWINGS
The following figures and drawings are included after this page:
Options
LTW MK-15, Remote Panel From Sn 90, Panel Cut Out 3-8011 A 1
XBT-N 401
LTW MK-15B Wiring Diagram from S/N No. XX, 4-1123 A 1
Operator/Remote Panel
Bandak AS, LTW MK-15, Manual TSXSCA62 3-8058 - 1
LTW MK-15B, Filter 24V 4-1133 - 1
16 178539/F
Installation Manual
Figure 1 Light Weight Taut Wire Mk 15B - Side View (Deployed Position)
Figure 2 Light Weight Taut Wire Mk 15B - Plan View (Deployed Position)
178539/F 17
Bandak Light Weight Taut Wire Mk15B
Figure 3 Light Weight Taut Wire Mk 15B - Side View (Stowed Position)
18 178539/F
Installation Manual
Wire
Operational
Area
Vessel side
Plan view
Taut Wire
Gimbal Head
Vessel side
max. max.
23o 23o
(Limited by
the horizontal
distance of the
gimbal head
from the
vessel side) Wire
Operational Area
Depressor Weight
178539/F 19
Bandak Light Weight Taut Wire Mk15B
800
5
1 Cabinet
0
1
3
Service 1
Area 0
20 178539/F
Installation Manual
800 mm
31 mm
4 ea. Ø 10 mm
(max.) holes
500
mm
39
mm
178539/F 21
Bandak Light Weight Taut Wire Mk15B
625
25
(CD2600) 12 x 18.5 25
22 178539/F
Installation Manual
Between arms,
around shaft
178539/F 23
Bandak Light Weight Taut Wire Mk15B
Cable Entrances.
PG-29 (used when cable no. 4, Recommended
5, 6 and 9 are bundled together. Cable Sequence
(top-down): 6, 4, 9,
5. Recommended
PG-gland (top-
down): 21, 21, 16,
16.
Cable no.
13
24 178539/F
Installation Manual
178539/F 25
Bandak Light Weight Taut Wire Mk15B
26 178539/F
Installation Manual
178539/F 27
Bandak Light Weight Taut Wire Mk15B
28 178539/F
Connection cable XBT 7908 from
bridge control to plug 2. Length 1,8 m.
D D
UNDERSIDE LID
POSITION FOR SWITCHES
FERRITE IS MOUNTED
BY BANDAK
65
50
B B
NS-ISO 2768-1
Replaces Replaced by
Bandak AS
A LTW MK15 Drawing no Revision
A
Manual, TSXSCA62 3-8058
Scale 1:2 System Fromat Projection
Autodesk Inventor A3 1 of 1
File name