Professional Documents
Culture Documents
________________________________________________________
Aim: To conduct Load test on the given Cascaded Induction Motor and to draw the
Performance and Mechanical characteristics.
Apparatus Required:
Formulas Used:
Procedure:
The connections are made as the circuit diagram.
After checking the initial condition , the TPST switch is closed.
The auto-transformer is varied to get the rated voltage.
Ensure the motor speed is near to the synchronous speed.
Now the DPST switch connected in the field of the generator is closed so that field is
excited.
The field rheostat is adjusted till the voltmeter connected across the armature of the
generator reads rated voltage.
No-load readings are taken.
Then the DPST switch is connected in load side is closed.
The readings are noted at different values of load.
Model Calculation:
Reading No:___
Line Voltage,VL=_____V;Line Current, IL=______A
Generator Voltage=______V
Load Current=_____A
Wattmeter Reading=______W
K= Current coil rating × Voltage coil rating /no.of.divisions.
Tabulation:
S.no Line Line Wattmeter Voltage,Vdc Load Output Speed,N Torque Slip cos φ Input
Voltage Current Reading (V) Current,I dc Power ,PO Efficiency, rpm T(Nm) (%) power
,VL (V) , IL(A) (kW) (A) (W) (%η)
Result:
Thus the Performance and Mechanical characteristics of the Cascaded Induction
motor has been drawn and tested.