96M17620 • If the product is used in a manner not specified by this manual, the

protection provided by the product may be impaired.


Part Names Installation Method
• You must perform a sufficient risk assessment for the machine where  CG-MP120T
WARNING
this product is to be installed prior to installing this product. Provide NOTICE Mount the controller in a stable location that is free from vibration.
appropriate protective fail-safe measures on the machine independent
from this product in case a failure with this product should occur.  Typical installation examples
Do not operate the unit after disassembling or modifying it. Doing so
CAUTION
may result in fire, electrical shock, or device failure.  CG-MP120T
1
Display panel, 12-inch  Installation location 2
The mounting angle is restricted by ambient temperature.
Adjust the mounting angle to suit the mounting circumstances.
CG-MP120T Avoid locations such as the following when installing the CG-MP120T/
CG-MU100: 3
Vertical direction

Display unit • Locations where the unit is exposed to direct sunlight.


• Locations where the surrounding air temperature exceeds the range
Ambient temperature: 0 to 50 °C

CG-MU100 listed in the specifications. Locations prone to rapid temperature


changes.
• Locations with poor ventilation.
Ambient temperature: 0 to 40 °C

Instruction Manual • Locations where relative humidity exceeds 85% RH. Locations subject to
condensation.
Read this manual before using the product in order to achieve maximum performance. • Locations where corrosive or flammable gasses are present.
Keep this manual in a safe place after reading it so that it can be used at any time. • Locations where there is excessive dust, salt, or iron powder. NOTICE
CAUTION
• Locations where the unit is exposed to splashes of substances such as
water, oil, or chemical agents.
Introduction • Locations where the unit is subject to direct vibrations or mechanical
shocks.
The devices described in this manual are a display panel and display unit for the • Locations where the unit may be influenced by radiation noise or static
electricity. 15° 15°
KEYENCE Vision system. To use these units safely, carefully read this manual, the • Separate the unit and the cables as far as possible from high-voltage
notes on use, and the instruction manuals for the devices to which these units are to be
6 7 4 5 8 30°
lines and power lines. Interference from such lines may result in
connected. nonstandard operation or device failure.
For settings details and instructions, see the Setup and User's Manuals provided with No Name Function
the Vision system. Manuals, CAD data, and other related materials can be downloaded 1 Display - Touch panel area Displays settings for the KEYENCE Vision System.
from the following website. Precautions on Regulations and Standards 2 Power supply LED Lights green while power is supplied to the unit.
You can also download the software and firmware of the Vision Horizontal direction
system from this website.  CE and UKCA Markings 3 USB connector (USB2.0)

www.keyence.com/vs-support
KEYENCE Corporation has confirmed that this product complies with the essential
requirements of the applicable EU Directive(s) and UK regulations, based on the 4
USB-1 connector (USB3.0/ 1 Cut open a mounting space at the size shown below for fitting the dedi-
2.0) Connect a mouse, keyboard, or other devices. cated monitor for CG-MP120T.
following specifications. Be sure to consider the following specifications when using
You can also scan the QR code to the right to access the support USB-2 connector (USB3.0/
this product in the Member States of European Union and in the United Kingdom. 5
site. 2.0)
EMC Directive (CE) and Electromagnetic Compatibility Regulations
 Symbols (UKCA) 6 ETHERNET-1 connector Used for connection to the KEYENCE Vision
The following warning symbols are used to ensure safety and to prevent human injury • Applicable standard:(BS) EN61326-1, Class A 7 ETHERNET-2 connector system.
and/or damage to property when using the system. • Use cables shorter than or equal to 30 m to connect this product and its external Connect to a DC 24 V power supply and to
devices. 8 Power connector
Indicates a hazardous situation which, if not avoided, will result in ground. +1
DANGER
death or serious injury. Remarks: These specifications do not give any guarantee that the end-product with 227.5 -0
this product incorporated complies with the essential requirements of EMC Directive
Indicates a hazardous situation which, if not avoided, could result in
and Electromagnetic Compatibility Regulations. The manufacturer of the end-product
 CG-MU100
WARNING
death or serious injury.
is solely responsible for the compliance on the end-product itself according to EMC
Indicates a hazardous situation which, if not avoided, could result in 1
CAUTION Directive and Electromagnetic Compatibility Regulations.
minor or moderate injury. 2
Indicates a situation which, if not avoided, could result in product  North American Regulations 3
NOTICE
damage as well as property damage. This product complies with the following North American regulations.
• Applicable regulationFCC Part15 Subpart B, Class A Digital Device 4
Indicates cautions and limitations that must be followed during +1
Important
operation. ICES-003, Class A Digital Apparatus 301.5 Unit: mm
5 -0
• Operation is subject to the following two conditions: (1) This device may not cause
Point Indicates additional information on proper operation. harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. 6 2 Insert the dedicated monitor for CG-MP120T into the opening of the
Indicates tips for better understanding or useful information. • FCC CAUTION industrial control panel for mounting.
Reference
Changes or modifications not expressly approved by the party responsible for 7
 Trademarks compliance could void the user’s authority to operate the equipment.
8 3 Fix the dedicated monitor for CG-MP120T onto the panel using the
• Microsoft and Windows are either registered trademarks or trademarks of the  CSA Certificate mounting brackets and tighten the screws on the mounting brackets.
Microsoft Corporation in the United States, registered trademarks or trademarks in This product complies with the following CSA and UL standards and has been certified 9
• Mounting brackets are mounted on the sides (four part of top and bottom) of the
the United States and/or other countries. by CSA. 10 dedicated monitor for CG-MP120T.
• The terms HDMI, HDMI High-Definition Multimedia Interface, HDMI Trade dress and • Applicable standard:CAN/CSA C22.2 No.61010-1
After attaching all of the mounting brackets, mount starting from the short side in
the HDMI Logos are trademarks or registered trademarks of HDMI Licensing UL61010-1
the order shown below.
Administrator, Inc. Be sure to consider the following specifications when using this product as a product No Name Function (i.e., from (1) to (4))
• Other company names and product names are registered trademarks or trademarks certified by CSA.
1 Power supply LED Lights green while power is supplied to the unit. • Please confirm the mounting brackets is next to the front side (backside of
of their respective companies. The TM mark and ® mark are omitted in this manual. • Overvoltage category I
2 USB-1 connector (USB2.0) dedicated monitor for CG-MP120T) before tightening.
• Use this product under pollution degree 2.
 Software information • Use this product at the altitude of 2000m or less. USB-2 connector (USB3.0/ (1)
• Indoor use only. 3
This product incorporates the software files developed independently by or for 2.0) Connect a mouse, keyboard, or other devices.
Keyence Corporation, software files owned and licensed by a third party, and software • Do not connect the units to devices with positive ground connections.
files subject to certain open source license agreements. USB-3 connector (USB3.0/
• Do not install the units upside down or on an incline (CG-MP120T only). 4
• The open source software files are subject to the notices and additional terms and 2.0)
conditions. For information about such open source software files, please refer to the  KC mark (Republic of Korea) 5 ETHERNET-1 connector
“License Information” in the “Version Information” menu option under “Help” in the Used for connection to the KEYENCE Vision (4)
VS Creator software for VS Series. 사 용 자 안 내 문 6 ETHERNET-2 connector system.
• Such open source software files are provided on an “AS IS” basis to the maximum 7 HDMI connector Connect to an HDMI monitor.
extent permitted by applicable law. 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가정용 환경
• If there is any discrepancy between the terms and conditions of the applicable open 에서 사용하 는 경우 전파간섭의 우려가 있습니다. Connect to a DC 24 V power supply and to
8 Power connector *
source license agreement and the “License”, the terms and conditions of the ground.
applicable open source license agreement prevail with respect to the applicable
Checking the Package Contents A power switch for use only when power is (2)
open source software. 9 Power switch
supplied from an AC adapter.
This product includes the following items. Make sure that all of the items are in the Power connector (AC Connect an AC adapter (OP-88766: available
Safety Information package. 10
adapter) * separately).
 CG-MP120T
 General precautions  Display panel, 12-inch ............................................................................................ ×1 * Power can be supplied via either the DC 24 V connector or an AC adapter. The unit (3)
• Do not use this product for the purpose to protect a human body or a  Power source block ................................................................................................ ×1 cannot be connected to two power sources simultaneously.
part of a human body.  Panel mounting brackets ........................................................................................ ×4 • Please ensure to use all the mounting brackets (x4) for installing the
• Do not use this product in a hazardous location and/or potentially  Microsoft End-User License Agreements (EULA) .................................................. ×1 dedicated monitor for CG-MP120T.
explosive atmosphere.  Instruction Manual (this document) • In the case that only one of the short sides of the dedicated monitor for
CG-MP120T is mounted or no sufficient number of brackets are used, the
DANGER • Do not use this product in an application that may cause death, serious  CG-MU100 NOTICE Protection IP65f cannot be guaranteed.
injury or serious property damage due to a failure with this product
should occur, such as nuclear power plants, on aircraft, trains, ships, or  Display unit ............................................................................................................. ×1 • Tighten with the specified torque (0.3 to 0.5 N·m).
vehicles, used within medical equipment, playground equipment, roller  Power source block ................................................................................................ ×1 • Even when tightened with the specified torque the display sheet may
coasters and other rides, etc.  DIN rail mounting adapter ...................................................................................... ×1 become wrinkled or bent depending on how it is tightened. This will not
 Screws for DIN rail mounting adapter (four M3×L=6 double SEMS screws) ...... 1 set affect operation.
 Microsoft End-User License Agreements (EULA) .................................................. ×1
 Instruction Manual (this document) Reference The dedicated monitor for CG-MP120T can not only be installed to the
panel bracket, it can be installed to the monitor stand (OP-87262: optional).

E1 E2
 CG-MU100
Wiring and Operation Method Main Specifications
Secure the unit in an upright position using the holes provided for
 Connecting an Ethernet (LAN) Cable
the attachment screws. Model CG-MU100 CG-MP120T
For connections to the KEYENCE Vision system, connect an Ethernet cable to the unit’s
ETHERNET connector. For information on operating and configuring this product, see LCD panel
the Vision system setup manual. Display element TFT LCD
Point The ETHERNET-1 and ETHERNET-2 connectors are connected to each Display colors Approximately 16 million
other inside the unit via a bridge. Be careful that they do not create a Resolution 1024 (W) × 768 (H)
loop on the host network.
Backlight Life Approximately 50,000 hours
 Connecting an HDMI Monitor (CG-MU100 Only) (at room temperature and normal humidity)
Connect an HDMI monitor to the HDMI connector.
Touch screen Type Analog resistive touch screen
Point The unit supports touch screen controls via USB. Note, however, that Life Over one million activations
operation is not guaranteed with all devices.
Interface
 Connecting a 24 V Power Supply HDMI Number of ports 1
Connect the DC 24 V, 0 V, and ground connectors using the power source block
supplied with the unit’s power connector (a UL1015-AWG #16 or Resolution Up to 1920 (W) × 1080 (H)
1007-AWG #16 power cable is recommended). Ethernet Number of ports 2 (bridged)
 CG-MP120T Connector type RJ-45
Standards 1000BASE-T/100BASE-TX/10BASE-T
Reference Instead of using the holes provided for the attachment screws, you can USB Number of ports 3 *1 1 front port, 2 rear ports
attach the supplied DIN rail mounting adapter to the unit and mount the unit
on a DIN rail. Power supply
Voltage DC24V +25%/–20%
Be careful in regard to cooling the unit in the installation site
Consumption 2.3A, 44.2W (at 19.2 V) / 1.9A, 45.6W (at 24 V) 2.5A, 48W (at 19.2 V) / 2.0A, 48W (at 24 V)
(Installing the Unit Upright or on a DIN Rail)
For ventilation, keep the space free of objects for 50 mm or more 1 2 3 4 Other
above the controller and 50 mm or more for both sides. Weight Approximately 830 g Approximately 2,400 g
If spaces of 50 mm or more are ensured of even on the underside
orientations of DIN rail mounts, etc., then the units can be used at Dimensions (W × H × D) 56.5 mm × 180.0 mm × 161.4 mm 312.3 mm × 245.3 mm × 60.1 mm
higher than rated temperatures.
IP rating Built-in panel; front controls only are dust- and drip-proof
(Installing the Unit Base Down) 1 24V + power supply input (24VDC+) with a rating equivalent to IP65f *2
Install the unit in a location free of obstacles that could block the
vents. 2 0V – power supply input (24VDC–) Materials Main casing: Polycarbonate Main casing: Polycarbonate
NOTICE
Do not install the unit upside down. 3 N.C Not used (NC). Front sheet: PET
4 FG Ground connector ( ) Operating temperature 0 to +45°C (with DIN rail)/ 0 to +50°C (in vertical installations) *3
0 to +40°C (in vertical and horizontal installations)
 CG-MU100 Operating humidity 85°C RH or less (no condensation)
Certification standards CE, FCC, NRTL, KC, UKCA
*1 Can be used for touch panel control. Note, however, that operation is not guaranteed with all devices.
*2 Assumes front USB cover is closed.
1 *3 For information on the rating when the unit is installed in orientations other than the vertical, see “Installation Method” in this manual.
2
3

1 24V + power supply input (24V)


2 0V – power supply input (0 V)
3 FG Ground connector ( )

 Connecting an AC Adapter (CG-MU100 Only)


Connect an AC adapter (OP-88766: available separately) to the CG-MU100’s
AC adapter power connector.
Point Power can be supplied to the CG-MU100 via either the DC 24 V
connector or an AC adapter. Do not connect the unit to two power
sources simultaneously, as this could cause the product to
malfunction.

Reference The power switch on the CG-MU100 controls the supply of power from the
AC adapter. It has no effect when the unit is connected to a DC 24 V power
supply.

Copyright (c) 2023 KEYENCE CORPORATION. All rights reserved.


17620GB 2093-1 96M17620 Printed in Japan

E3 E4