1. OVERVIEW
WARNING CAUTION
Before mounting or dismounting this unit to or from the GOT, When fumigants that contain halogen materials such as fluorine, This User's Manual describes the GT15 bus connection unit
MODEL GT15-QBUS/GT15-QBUS2/ always shut off GOT power externally in all phases. chlorine, bromine, and iodine are used for disinfecting and (hereinafter referred to as the bus connection unit).
Not doing so can cause a unit failure or malfunction. protecting wooden packaging from insects, they cause Use the bus connection unit for making bus connection of the GOT.
GT15-ABUS/GT15-ABUS2 malfunction when entering our products.Please take necessary Refer to the User's Manual for the GOT used for the applicable GOT.
BUS CONNECTION UNIT CAUTION
precautions to ensure that remaining materials from fumigant do
not enter our products, or treat packaging with methods other
Use this unit in the environment that satisfies the general than fumigation (heat method).Additionally, disinfect and protect
2. SPECIFICATIONS
User's Manual specifications described in the User's Manual for the GOT used. wood from insects before packing products.
Not doing so can cause an electric shock, fire, malfunction or The performance specifications of the bus connection unit are
product damage or deterioration. Manuals indicated below.
When installing this unit to the GOT, fit it to the connection The general specifications of the bus connection unit are the same
interface of the GOT and tighten the mounting screws in the The following shows manuals relevant to this product. as those of the GOT.
specified torque range (0.36 N•m to 0.48 N•m) with a Phillips- Refer to the User's Manual for the GOT used for the general
head screwdriver No.2. Undertightening can cause a drop, Detailed Manual specifications of the GOT.
failure or malfunction. Overtightening can cause a drop, failure GT15- GT15- GT15- GT15-
or malfunction due to screw or unit damage. Item
Manual number QBUS QBUS2 ABUS ABUS2
Manual name
(Model code) QCPU (Q Mode) QnA/ACPU
[WIRING PRECAUTIONS] Interface
bus connection bus connection
GT16 User's Manual (Hardware) SH-080928ENG
IN 1 1 1 1
WARNING (Sold separately) (1D7MD3) Connector
Thank you for purchasing the GOT1000 Series. Before connecting the Bus connection cable to this unit, always
OUT - 1 - 1
GT15 User's Manual SH-080528ENG
shut off GOT power and PLC CPU power externally in all 16 points 32 points
(Sold separately) (1D7M23)
phases. Not doing so can cause a malfunction. I/O occupied points (I/O assignment: (I/O assignment:
Prior to use, please read both this manual and detailed 16 intelligent points) Special 32 points)
GOT1000 Series Connection Manual
manual thoroughly to fully understand the product. SH-080868ENG
(Mitsubishi Products) for GT Works3 Internal
(1D7MC2)
CAUTION (Sold separately) current
0.44A 0.44A 0.12A 0.12A
consumption
Insert and fit the bus connection cable into the connector of the (5VDC)*
MODEL GT15-BUS-U
unit to be connected until it "clicks". After fitting, check for lift Relevant Manuals
0.13kg 0.14kg 0.13kg 0.14kg
MODEL which can cause a malfunction due to a connection fault. Weight
1D7M39 (0.29lb) (0.31lb) (0.29lb) (0.31lb)
CODE For relevant manuals, refer to the PDF manuals stored in the DVD-
[STARTUP AND MAINTENANCE PRECAUTIONS] ROM for the drawing software used. * When the GOT power is on, the internal current consumption is
IB(NA)-0800323-J(1410)MEE included in the current consumption of the GOT.
WARNING © 2005 MITSUBISHI ELECTRIC CORPORATION When the GOT power is off, the internal current is supplied from
the power supply of the PLC system.
Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or Compliance with the EMC and Low Voltage
Select the used bus connection unit according to the connection
malfunction. Directives target and connection position.
To configure a system meeting the requirements of the EMC and Low
Voltage Directives when incorporating the Mitsubishi GOT (EMC and <Bus connection unit selection example>
CAUTION Low Voltage Directives compliant) into other machinery or
Do not disassemble or modify any unit. equipment, refer to "EMC AND LOW VOLTAGE DIRECTIVES" of the
(1)Select the bus connection unit according to the
This will cause failure, malfunction, injuries, or fire. General Description included with the GOT used. connection target.
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.) Do not touch the conductive areas and electronic parts of this The CE mark, indicating compliance with the EMC and Low Voltage
QCPU (Q Mode), motion controller Q series
unit directly. Doing so can cause a unit malfunction or failure. Directives, is printed on the rating plate of the GOT.
Before using this product, please read this manual and the relevant : GT15-QBUS/GT15-QBUS2
manuals introduced in this manual carefully and pay full attention to Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.Not doing so can cause unit or cable
Compliance with the Radio Waves Act (South ACPU, QnACPU, motion controller A series
safety to handle the product correctly. The precautions given in this : GT15-ABUS/GT15-ABUS2
manual are concerned with this product. In this manual, the safety damage due to dangling, moved or accidentally pulled cables or Korea) (2) Select the bus connection unit according
precautions are ranked as "WARNING" and "CAUTION". can cause a malfunction due to a cable contact fault. This product complies with the Radio Waves Act (South Korea). to the GOT connection position.
Do not hold the cable part when unplugging any cable Note the following when using the product in South Korea.
Indicates that incorrect handling may cause connected to the unit. Doing so can cause unit or cable damage Placed midway
WARNING hazardous conditions, resulting in death or or a malfunction due to a cable contact fault. 이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 : GT15-QBUS2/GT15-ABUS2
severe injury. 사용자는 이 점을 주의하시기 바라며 , 가정외의 지역에서
Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit. 사용하는 것을 목적으 로 합니다 .
Indicates that incorrect handling may cause (The product is for business use (Class A) and meets the
CAUTION hazardous conditions, resulting in medium or Failure to do so may cause a failure or malfunctions of the unit.
electromagnetic compatibility requirements.
slight personal injury or physical damage. The seller and the user must note the above point, and use the
[DISPOSAL PRECAUTIONS] product in a place except for home.) Placed at end
Note that the CAUTION level may lead to a serious accident CAUTION : GT15-QBUS/GT15-ABUS
according to the circumstances. Always follow the precautions of Packing List GT15-QBUS2/GT15-ABUS2
both levels because they are important to personal safety. Dispose of this product as industrial waste. The following items are included. When using the bus connection, make the communication settings to
Please save this manual to make it accessible when required and perform communication between the GOT and PLC.Refer to
[TRANSPORTATION PRECAUTIONS] Model Product Quantity
always forward it to the end user. GOT1000 Series Connection Manual for details of bus connection.
Bus connection unit 1
CAUTION GT15-QBUS, When using bus connection unit, use a standard monitor OS and
[DESIGN PRECAUTIONS] GT15-ABUS Mounting screws set (2 screws, 2
1 communication driver of GT Designer2 Version2.15R or later.
Make sure to transport the GOT main unit and/or relevant unit(s) stickers) With a standard monitor OS and communication driver of an older version,
CAUTION in the manner they will not be exposed to the impact exceeding the GOT has cannot recognize the unit to perform monitoring.
Bus connection unit 1
Do not bunch the control wires or communication cables with the impact resistance described in the general specifications of
the main circuit or power wires, or lay them close to each other. the User's Manual for the GOT used, as they are precision GT15-QBUS2, Mounting screws set (2 screws, 2
2
As a guide, separate the lines by a distance of at least 100mm devices. Failure to do so may cause the unit to fail. GT15-ABUS2 stickers)
(3.94 inch) otherwise malfunctions may occur due to noise. Check if the unit operates correctly after transportation. Extension interface relay board 1
back extension unit is installed 3) Attach the extend interface relay board to the extend
98(3.86)
5) human life.
I/F-2 side on the GOT. After the installation, detach the connector
Mounting screws fixed with a • Before using the product for special purposes such as nuclear
5) Mounting screw cover from the extend inter face relay board. power, electric power, aerospace, medicine or passenger
front extension unit or GOT For the following GOT types, the extension interface relay board movement vehicles, consult with Mitsubishi.
Screw for fixing the extension is not needed.
6) Board fixing screw • This product has been manufactured under strict quality control.
• GT1655,GT155 of the GOT1000 series
A
2.5 interface relay board However, when installing the product where major accidents or
(0.10) 7) • GT27,GT25 of the GOT2000 series
X losses could occur if the product fails, install appropriate backup or
30.5(1.20)
7) Rating plate - 4) Fit the bus connection unit in the GOT case. failsafe functions in the system.
(0.85)
21.5
Tel : +44-1707-276100
98(3.86)
6) 5) Fasten the bus connection unit by tightening its mounting screws Italy Mitsubishi Electric Europe B.V. Italian Branch
(4 places) with tightening torgue 0.36 to 0.48 N•m. Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy
7) 6) Fasten the bus connection unit by tightening the board fixing Tel : +39-039-60531
screws (2 places) with the tightening torque of 0.36 to 0.48 N•m. Spain Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80,
5) 6)
A
Tel : +27-11-928-2000
D 2) 1) C Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, Hong Kong
Extension interface relay board Tel : +852-2887-8870
7) When installing an extension unit on the unit that has been China Mitsubishi Electric Automation (China) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
installed, remove the connector cover and the sticker. When not
24(0.94)
8.4” 23 (0.91) 23 (0.91) 23 (0.91) 23 (0.91) Sticker When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
5.7” 23 (0.91) 23 (0.91) - - Specifications subject to change without notice.
Printed in Japan, October 2014.
Unit: mm (inch)