Professional Documents
Culture Documents
Operation Manual
Version:V1.1
RBMS 监控软件
用户操作手册
RBMS Monitor Software
User Operation Manual
编制 Write 审核 Check 批准 Approved
Document number:007-01
Operation Manual
Version:V1.1
目 录 Catalog
1. 适用范围SCOPE OF APPLICATION ........................................ 1
2. 运行环境OPERATING ENVIRONMENT ....................................... 1
3. 准备工作 PREPARATION BEFORE WORK .................................... 2
4. 软件安装SOFTWARE INSTALLATION ....................................... 4
5、软件功能操作指南SOFTWARE FUNCTION OPERATION GUIDE ................... 5
本文件适用于湖南群控能源科技有限公司生产的高压锂电池管理系统监控软件
RBMS_Monitor。
This document applies to the high-voltage lithium battery management system RBMS_Monitor
软 件 环 境
Software Environment
操作系统
Windows XP\WIN7\WIN8\WIN10\WIN11
operating system
数据管理
SQLite
Data base
硬 件 环 境
Hardware environment
建议配置(建议使用品牌机)
最低要求 Minimum requirements
Recommended configuration (brand machine)
AMD,INTEL 单 核 Single
CPU CPU AMD,INTEL 双核 Dual-core
core
内存 RAM 1G 内存 RAM 4G
Step 1:
关闭电脑上安全卫士类的杀毒软件,关闭电脑自身的防火墙以避免被误拦截,或者在系统提示
是否允许软件访问网络时勾选对应网络并确认。
Close the anti-virus software of the security guard on the computer, close the firewall of the
computer itself to prevent the program from being intercepted by mistake.
Step 2:
将待升级设备开机,用网线连接 RBMS 面板上的 LAN 接口和电脑的网口,LAN 接口位置如
下图红框处所示:
The upgraded equipment will be booted, and the LAN interface on the RBMS panel and the
computer's network interface will be connected by the wire. The LAN interface location is shown in
the red box below:
Document number:007-01
Operation Manual
Version:V1.1
RBMS 监控接口
Monitor port of RBMS
1、本软件为纯绿色软件。将软件目录直接拷贝到硬盘目录下即可使用。软件目录下文件
如下图所示:
The software is pure green software. You can use the software directory directly to the hard disk
directory. The files in the software directory are as shown below:
2、双击“RBMS_Monitor.exe”以运行软件
Document number:007-01
Operation Manual
Version:V1.1
打开软件后,将显示软件的主界面(如下图),用户可以根据需要实时查看当前电池串数,
电池电压,电流,温度,SOC,SOH 等。
After opening the software, the main interface of the software will be displayed (as below),
users can view the current battery string count, battery voltage, current, temperature, SOC, SOH, etc.
in real time as needed.
Document number:007-01
Operation Manual
Version:V1.1
1)软件运行后,在左边列表选择界面,如下图所示:
Once the software is running, select the interface in the list on the left, as shown in the following
figure:
Confirm that the Local IP is the same as wired net card IP mentioned in prepare work step.
3)选择好 IP 后,点击查找设备按钮:
After selecting IP, click the Search Devices button:
Document number:007-01
Operation Manual
Version:V1.1
4)如果设备正常连接,设备 IP 会显示在下面的设备列表。如下图所示:
If the device is connected properly, the device IP will be displayed in the device
list below. As shown in the figure below
5)当有设备连接后,选择设备 IP,点击开始监控按钮,即可以监控和管理该设备数据。当成
功启动监控后,开始监控按钮变为停止监控按钮,再次点击即可停止监控。
When a device is connected, select the device IP and click the Start Monitoring button, that is, you
can monitor and manage the device data. When the monitoring is successfully started, the Start
Monitoring button changes to Stop Monitoring button, click it again to stop monitoring.
6)当有多个设备连接时,列表会出现多个 IP,如果需要对设备进行切换,直接在设备列表中
选择 IP 即可。数据显示区域,只能显示当前 IP 设备数据。
When there are multiple devices connected, the list will appear multiple IPs, if you
need to switch the device, you can select the IP directly in the device list. Data
Document number:007-01
Operation Manual
Version:V1.1
点击”Monitor”标签页,软件界面切换如下:
Click on the "Monitor" tab and the software interface will switch as follows:
Document number:007-01
Operation Manual
Version:V1.1
信息项 信息内容
Item Description
显示系统总电压、正负半簇电流、充放电状态、SOC、SOH、最
高最低单体电压以及对应的模组编号和模组内电芯编号、最高最
低温度以及对应的模组编号和模组内温度编号
系统信息 Displays total system voltage, positive and negative half-cluster
System Information current, charge and discharge status, SOC, SOH, maximum and
minimum individual voltage and corresponding module number and
core number within the module, maximum and minimum temperature
and corresponding module number and temperature number within
the module
选择模组编号来查看各个模组内的电压和温度。
显示的电压个数由软件根据设备内参数自动决定,最多支持显示
24 个电压和 8 个温度。如果温度异常则显示为空
模组信息 Select the module number to view the voltages and temperatures
Module Information within each module.
The number of voltages displayed is determined automatically by the
software based on the parameters in the device, and supports up to 24
voltages and 8 temperatures. If the temperature is abnormal, the
display will be empty.
模组通信状态
根据模组个数来显示,绿色表示通信正常,红色表示通信异常
Module
According to the number of modules to display, green indicates
communication
normal communication, red indicates abnormal communication
status
模组电压状态 绿色表示对应模组内电芯电压正常,红色表示异常
Module voltage Green means the voltage of the cell in the corresponding module is
status normal, red means abnormal
模组温度状态 绿色表示对应模组内温度正常,红色表示异常
Module temperature Green indicates normal temperature in the corresponding module, red
status indicates abnormal
告警状态分三级,告警状态,一级保护,二级保护。
如果告警状态,对应的状态显示为黄色。
如果一级保护或二级保护。对应的状态为红色。
The alarm status is divided into three levels, alarm status, primary protection, and secondary
Document number:007-01
Operation Manual
Version:V1.1
protection.
If the alarm status is displayed, the corresponding status is displayed in yellow.
If primary protection or secondary protection. The corresponding status is red.
如下图所示:As shown below:
其他自检状态,如下图所示
Self-test error status, as shown below
Document number:007-01
Operation Manual
Version:V1.1
2)断路器开关状态,如下图所示
Circuit breaker switch status, as shown below
名称 描述
Item Description
断路器 根据设备配置,可能会有不同的显示。
MCB 仅在断路器/接触器带有辅助触点的情况下才会显示。
正极充电接触器 无中线设备不会显示负极充电接触器状态
Positive Charge Contactor 状态有三种:
放电接触器 闭合
Discharge Contactor 断开
故障
Depending on the device configuration, different displays may be
available.
Only displayed if the circuit breaker/contactor has an auxiliary
contact.
负极充电接触器 Devices without centerline will not display negative charging
Negative Charge Contactor contactor status
There are three states:
CLOSED
Disconnected
Fault
Document number:007-01
Operation Manual
Version:V1.1
点击参数设置按钮,软件界面切换如下:
Click the parameter setting button and the software interface switches as follows.
序号 描述
Item Description
查看和设置系统额定放电功率、系统个数、模组内电芯个数、
模组内温度个数、以及设备时间
1 系统参数
View and set system power rating, number of systems, number of
System parameters
cells in the module, number of temperatures in the module, and
device time
查看和设置电池组额定充放电电压电流参数、电池组过压欠压
告警保护解除参数、电池组充放电过流告警保护解除参数
2 电池组参数
View and set battery pack rated charge/discharge voltage and
Cluster parameters
current parameters, battery pack over-voltage and under-voltage
alarm protection disarm parameters, battery pack charge/discharge
Document number:007-01
Operation Manual
Version:V1.1
注: 软件将对参数进行有效性判断,错误的参数在点击设置按钮时软件将提示非法,非法
的参数背景颜色将变为红色。默认设置参数密码为 2000
Note: The software will judge the validity of the parameters, and the wrong parameters will be
prompted by the software as illegal when clicking the set button, and the background color of the
illegal parameters will change to red. The default setting parameter password is 2000
Document number:007-01
Operation Manual
Version:V1.1
点击”Off-line Records”标签,软件界面切换如下:
Click on the "Off-line Records" tab, and the software interface will switch as follows:
序号 描述
Description
1 读取指定时间段内的离线记录
Retrieve offline records within a specified time period
2 按时间段查询
Search by time period
3 按设备 IP 地址查询
Search by IP address
4 查询对应的电池数据(暂不支持)
Temporarily not supported
5 选择 2 和 3 以后,点击此按钮,在软件已经读取到的所有离线记录中
查询
After selecting 2 and 3, click on this button to search through all the
Document number:007-01
Operation Manual
Version:V1.1
点击实时记录按钮,软件切换界面如下:
Click the”Real-time Records” button and the software interface switches as follows.
每接收到一条记录,则当前界面会自动添加一条到最下方,菜单功能参考5.4离线记录查看
Every time a record is received, the current interface will automatically add one to the bottom,
Document number:007-01
Operation Manual
Version:V1.1
点击通信日志按钮,软件切换界面如下:
序号 描述
Item Description
将当前显示的通信日志保存在软件目录下的
1 保存 work_Communication.txt 中
Save Save the currently displayed communication log in
work_Communication.txt in the software directory
2 清空 清除当前显示的所有通信日志
Clear Clear all communication logs currently displayed
Document number:007-01
Operation Manual
Version:V1.1
点击软件参数按钮,切换到软件参数页面,如下图所示:
Click the Software Parameters button to switch to the Software Parameters page, as shown in the
following figure
名称 含义 备注
Name Description Remarks
监控软件启动监控后与设备通信的周期
轮询周期
The cycle of communication with the device 1000ms
Polling cycle
after the monitoring software starts monitoring
数据返回延时 读取设备信息时,设备返回数据的超时时间 200ms
Document number:007-01
Operation Manual
Version:V1.1
6. 免责声明 Disclaimer
本公司对此文档拥有最终解释权,并有权对此规格书进行修订。产品规格如有变更,恕不
另行通知。
The company has the final interpretation of this document, and the right to amend this
specification. Product specifications are subject to change without notice.