Pearl Villa Rating System

Villa Energy Model Template

This energy model template has been developed to enable design teams to summarize model details and overall energy performance in order to demonstrate compliance
with the mandatory provisions of RE-R1 and optional requirements of RE-1 and RE-3 in the Pearl Villa Rating System.

This template must be populated by the Energy Modelling Specialist and verified by the Design Team MEP Engineer(s), having due consideration to the following:

* All input cells should be populated in all tabs aside from the Exceptional Method tab, which is only to be filled in if required.
* Summary 2: all model outputs should be input here, renewable and exceptional calculation methods should be input on the relevant tabs and will automatically be
deducted from the overall results.

* All other tabs should be fully populated as comprehensively as possible based upon the input data used in the energy model. Some cells have drop-down lists limiting
inputs based on the requirements, others require textual or numeric inputs. Some areas (such as Lighting) will have automatic calculations based on previously inputted
data. In these cases certain cells are deliberately locked to restrict user input.

Input Cells that may be changed by design teams

Energy Model Summary RE-R1: Minimum Energy Performance

Baseline Villa Annual Energy Consumption (kWh) 0 Mandatory Credit Achieved? No


Baseline Villa Annual Energy Consumption (kWh/m2) 0 Check Energy Model Template options on General Details tab

Proposed Villa Annual Energy Consumption (kWh) 0

Proposed Villa Annual Energy Consumption (kWh/m2) 0 RE-1: Improved Energy Performance

Annual Renewable Energy Generation (kWh) 0 Credit Points Awarded 0


Total Percentage Reduction (RE-1) 0.0%

Percentage of Energy from Renewables (RE-3) 0.0% RE-3: Renewable Energy

Credit Points Awarded 0

11-Feb-19 Version 1.1


Pearl Villa Rating System
Villa Energy Model Template

This summary provides a comparison of the relative performance of the Proposed Villa compared to the Baseline for the different energy end use types. Comparison for compliance purposes is made between the Baseline Villa Average performance and the Proposed Villa
performance inclusive of contributions from Renewables and Exceptional Methods. When the villa being modeled is assumed to represent other villas within the same development and having the same typology but different orientations, the worst case villa orientation
must be modeled as the proposed case.

Baseline Performance Proposed Performance


Annual Energy Consumption, kWh Baseline Villa, Average Annual Proposed Villa Annual Energy Consumption, kWh Exceptional Method Proposed Villa, Annual Energy Consumption,
Energy End Uses Energy Consumption, kWh (excluding Exceptional Method & Renewables) Annual Energy Savings, kWh kWh (excluding Renewables)
Baseline, 0o Rotation Baseline, 90o Rotation Baseline, 180o Rotation Baseline, 270o Rotation

Space Cooling Sensible 0 0 0

Space Cooling Latent 0 0 0

Space Heating 0 0 0

Fans 0 0 0

Interior Lighting 0 0 0

Exterior Lighting 0 0 0

Occupant Electricity 0 0 0

Domestic Hot Water (electricity) 0 0 0 0 0 0 0 0

Domestic Hot Water (solar thermal) 0 0 0 0 0 0 0 0

BASELINE TOTAL 0 Proposed Total (excluding Renewables) 0

0 Renewable Energy 0

PERCENTAGE IMPROVEMENT IN PROPOSED OVER BASELINE 0.0% PROPOSED TOTAL 0


Energy Consumption, kWh/year

Energy Consumption, kWh/year


1
1

Baseline
Proposed

Renewable Energy

1 Domestic Hot Water (solar


thermal)

Domestic Hot Water (electricity)

Occupant Electricity

1 Interior Lighting

Fans
Domestic Hot Water (solar thermal)
Domestic Hot Water (electricity)
Space Cooling Sensible

Space Cooling Latent

Occupant Electricity

0
Renewable Energy
Exterior Lighting
Interior Lighting
Space Heating

Fans

Space Heating

Space Cooling Latent

Space Cooling Sensible

0
1 2
Pearl Villa Rating System
Villa Energy Model Template

This section is intended for the Project Energy Modelling Narrative. This brief narrative should provide an overview of the project and outline how compliance with the credit
requirements is achieved. Content should include, but is not limited to, the following:
• A brief overview of the modelling process;
• Villa envelope systems & performance;
• HVAC performance;
• Justification for any significant energy savings associated with particular end-use categories in Summary 2;
• Details of any additional calculation methodologies noted in the Exceptional Method and Renewables tabs.
As well as highlighting targeted compliance within RE-1: Improved Energy Performance & RE-3: Renewable Energy Credits (where applicable).

In support of the narrative images from the thermal models of both the Proposed and Baseline thermal models should be provided.

Energy Modelling Narrative

Baseline Villa Thermal Model Image Proposed Villa Thermal Model Image
insert image of Baseline villa thermal model insert image of Proposed villa thermal model
Pearl Villa Rating System
Villa Energy Model Template

Project Details Design Team


Project Name Modelling Specialist

Project ID Company

Pearl Rating Stage PQP/PVRS Professional Name

Date PQP/PVRS Professional Number

Model Details Energy Model Template


Was the Modelling Specialist responsible for
Dynamic Simulation Modelling (DSM) Software Please select
populating this template?
Has the template been reviewed by the
DSM Software Version Number Please select
Engineer(s) responsible for MEP design?
Has the template been reviewed by the
Weather File Please select
Architect?
Has the necessary supporting documentation
Climate Zone Please select
been provided?

No

Villa Details
Location

Gross Floor Area (GFA), m2

Conditioned Floor Area (CFA), m2

Villa Footprint, m2

Number of Storeys

Number of villas within this typology


Pearl Villa Rating System
Villa Energy Model Template

The basline values are as per the prescriptive parameters of RE-R1. The U-value of each envelope element (e.g. wall, roof, window) must be
established as an area-weighted average calculation of all components present in the envelope element. To establish the overall wall U-value, all
types, thicknesses and areas of insulation must be accounted for in addition to any non-insulated areas that may be present such as structural areas,
mortar and joints. In the case of windows all glass and frame areas must be accounted for and where a centre pane U-value of 1.8W/m 2K is being used
as the compliance target, all frames must be thermally broken. Detailed U-value calculations for each envelope element must be demonstrated at
construction stage and supported by third party test certificates (e.g. test reports for insulation thermal conductivity for each type of insulation used)
and associated shop-drawings and tabulated areas associated with each component. For further clarification please contact the Estidama team.

Villa Envelope Details

Item Baseline Villa Proposed Villa

Roof Construction (U-value in W/m2K) 0.14

Above-Grade Wall Construction (U-value in W/m2K) 0.32

Below-Grade Wall Construction (U-value in W/m2K) 0.28

Exposed Floor (U-value in W/m2K) 0.15

Glazing Ratio
15.0%
(gross window-to-conditioned floor area)

Glazing U-value, (U-value in W/m2K) 2.2

Glazing SHGC 0.4

Shading Devices No shading and no window recesses

Air Leakage Rate (ACH) 0.35


Pearl Villa Rating System
Villa Energy Model Template

Note: Unless otherwise specified performance of all system components is based upon ARI test conditions. For ease of comparison between Baseline and Proposed Model components all elements should quote ARI compatible performance in preference
to local conditions.

HVAC System Overview System Details

Item Baseline Villa Proposed Villa Item Baseline Villa Proposed Villa

Fresh Air Provision

Main System Description Details of natural ventilation considerations

Details of mechanical ventilation (incl. balanced and


single aspect systems)

Details of fresh air flow rates if different from LV-R3


Heating System Ventilation Calculator
Fan power of any balanced supply and extract
Item Baseline Villa Proposed Villa systems

Heating Generation Fan power of any supply or extract only systems

Heating Fuel Source System Set Points

Seasonal Efficiency, kW/kW Details of temperature set points modelled 24oC

Details of humidity set points modelled 50%

Cooling System Other Considerations

Item Baseline Villa Proposed Villa


Details of any additional modelling considerations
Cooling Generation

Cooling Fuel Source

Coefficient of Performance (COP) 3.4


Pearl Villa Rating System
Villa Energy Model Template

This section considers the overall performance of internal and external lighting systems. Co
coverage. Lighting profiles provided must be followed in both the baseline and proposed cas

Villa Internal Lighting Load Details

Baseline
Space Units
Villa

Kitchen W/m² 12.9

Living Area (Bedroom) W/m² 11.8

Living Area (Non-Bedroom) W/m² 22.6

Toilet / Bathroom W/m² 9.7

Lounge / Recreation W/m² 12.9

Corridor / Transition W/m² 5.4

Garage W/m² 2.2

Villa External Lighting Load Details

Baseline
Space Units
Villa

Walkways <3m Wide W/linear meter 3.3

Walkways ≥3m Wide W/linear meter 2.2

Parking Lots and Drives W/m² 1.6

Main Entrance Door W/linear m of door width 98.0

Other Entrance Doors W/linear m of door width 66.0

Canopies and Overhangs W/m² 13.5

Building Façade W/m² for each illuminated surface 2.2


Entrance and Gate House W/m² of uncovered area 13.5
external lighting systems. Compliance is based upon achievement or improvement beyond the target values ou
the baseline and proposed cases.

Proposed Villa
Installed Load Power Density 00:00 - 01:00 - 02:00 -
Area (m2) 01:00 02:00 03:00
(W) (W/m2)
0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0:00 1:00 2:00

Proposed Villa

Area (m2) or Installed Load Power Density 00:00 - 01:00 - 02:00 -


01:00 02:00 03:00
Linear m (W) (W/m2 or W/m)

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00

0.0 Week day/end 0.00 0.00 0.00


0.0 Week day/end 0.00 0.00 0.00
nd the target values outlined in ASHRAE 90.1-2007. This may require separate calculation relating to lighting p

Profiles
03:00 - 04:00 - 05:00 - 06:00 - 07:00 - 08:00 - 09:00 - 10:00 - 11:00 - 12:00 - 13:00 - 14:00 - 15:00 - 16:00 - 17:00 -
04:00 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00

0.00 0.00 0.00 0.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.50 0.50 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.50 0.70

0.00 0.00 0.00 0.40 0.40 0.40 0.25 0.10 0.00 0.00 0.00 0.00 0.10 0.10 0.25

0.00 0.00 0.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.1 0.1 0.1 0.1 0.1 0.1 0.1 1.00

0.00 0.00 0.00 0.50 0.50 0.50 0.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25

3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00

Profiles

03:00 - 04:00 - 05:00 - 06:00 - 07:00 - 08:00 - 09:00 - 10:00 - 11:00 - 12:00 - 13:00 - 14:00 - 15:00 - 16:00 - 17:00 -
04:00 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
relating to lighting power and area of

18:00 - 19:00 - 20:00 - 21:00 - 22:00 - 23:00 -


19:00 20:00 21:00 22:00 23:00 24:00

0.00 1.00 1.00 1.00 1.00 0.00

0.70 0.70 0.30 0.30 0.00 0.00

0.45 0.50 0.50 0.45 0.25 0.08

1.00 1.00 1.00 1.00 1.00 0.00

1.00 1.00 1.00 1.00 1.00 1.00

0.50 0.50 0.50 0.50 0.50 0.50

0.25 0.25 0.25 0.25 0.25 0.25

18:00 19:00 20:00 21:00 22:00 23:00

18:00 - 19:00 - 20:00 - 21:00 - 22:00 - 23:00 -


19:00 20:00 21:00 22:00 23:00 24:00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00

0.00 0.50 0.50 0.50 0.00 0.00


0.00 0.50 0.50 0.50 0.00 0.00
Pearl Villa Rating System
Villa Energy Model Template

Baseline Villa: Minimum 50% of the total yearly hot water energy usage (kWh) associated with hot water generation for all the villas including staff usage is
to be generated from renewable sources. The system design must be based on the parameters included in the table below.

Domestic Hot Water Heating Calculation Assumptions

Item Baseline Villa Proposed Villa

Inlet Mean Water Temperature (°C) Winter 14oC / Summer 30oC Winter 14oC / Summer 30oC

Clothes washer present? Please select Please select

"Spa-tub" present? Please select Please select

Number of occupants check inputs

Hot water demand (l/person/day) 50

Number of water heaters

Storage Volume (litres) check inputs

Total Input Rating (kW)

Total Yearly Hot Water Energy Demand (kWh) 0

Total Yearly Hot Water Usage Generated from electric


0 0
heaters (kWh)
Total Yearly Hot Water Usage Generated from Renewable
0 0
Sources (kWh)

Percentage of energy generated from renewable sources


0% 0%
(%)

Basline Percentage of Domestic Hot Water tab must be at least 50%


Pearl Villa Rating System
Villa Energy Model Template

Occupant Electricity Calculation Assumptions


Number of electric range tops

Number of washing machines 0

Number of electric dryers 0

Number of fridges 0

Receptacle loads (approx. kW) 0


Pearl Villa Rating System
Villa Energy Model Template

Solar hot water systems designed to supply domestic hot water demands are included in the 'Domestic Hot Water' tab.
Supporting documentation should be provided for all associated calculations in order to demonstrate how the quoted values have been obtained.

Renewable Energy

Annual Energy Offset by


Technology Type Description
Renewable Technology (kWh)

Please select

Please select

Please select

Please select

Please select

Please select

TOTAL 0
Pearl Villa Rating System
Villa Energy Model Template
Note: For each exceptional calculation method, provide a narrative describing the calculation method and theoretical or empirical information supporting the accuracy of the method.

Exceptional Calculation Method

Description End Use Annual Energy Savings (kWh)

Please select

Please select

Please select

TOTAL 0