You are on page 1of 4

SaigonValve

Outdoor Digital Valve Controller & Datalogger

SV1/SV2/SV3 (219 × 139 x 78 mm)


Automatic and remote valve control
solution for water suppliers.
• 4G cellular data transmission supports all Vietnam’s mobile
carrier service providers.

• High-capacity built-in battery pack could provide continuous


service up to 3 years per full charge.
• Highly durable and IP68 rated aluminum enclosure
could provide years of maintenance-free service.
• GPS support helps locating all installed devices easily
for easier fleet management.
• Supporting various industrial sensor interfaces such as
4-20mA, Modbus, pulse. Please refer to this datasheet
to know which interfaces your product model support.
• 12VDC output helps supply power to your other devices in
places where electricity is unavailable.
• Logging and remote settings reconfiguring via cloud support
reduces labor and time to manage all devices. 219x139x78mm
SaigonValve SV3

Please read this document carefully for


correct usage of this product

Main I/O Functions

Sensor input interface:


 4-20mA Control output:
 Modbus  3 1C relay outputs
 Pulse formed by six 1A
relays for better
energy reservation

Cloud command input:


 Turn on/off relays (if any)
 Configure operation mode

 Automatic data processing


 Automatic relay control.
 Automatic data
transmission via 4G
connection

1
SaigonValve SV1/SV2/SV3
Standard Models

No. of 4-20mA No. of pulse


Model No. of Modbus inputs No. of relay outputs No. of 12V outputs
inputs inputs
SV1 1 2 1 0 3
SV2 4 0 1 0 3
SV3 3 1 1 6 3

Specifications

Nominal power supply voltage 24 VDC


Operating voltage range 90% to 105% of rated supply voltage
Power consumption 8 VA max. at 24VDC
Digital input:
Modbus RTU via RS485 physical lines.
Analog input:
Current input: 4 to 20 mA
Sensor input
Pulse input: 24VDC Max, 0 to 10 kHz
Current input: 10 Ω max.
Input impedance Pulse input: 100 kΩ min.
Control method ON/OFF control via relays (if any)
Control
Relay output SPDT 2A form, 240 VAC, max 5A current (resistive load), electrical life: 80,000 operations
output
Method of data
connection 4G cellular network
Data
transfer GPS support Yes
Setting method Digital setting from cloud

Installation method Wall mounting

Other functions Adaptive relay control based on settings configured by cloud


Ambient operating
20 to 55C (with no condensation or icing)
temperature
Ambient operating humidity 5% to 85%
Storage temperature 25 to 65°C (with no condensation or icing)
Altitude 2,000 m max.
Recommended fuses 0.75 to 1.5A, 250 VAC resettable fuses

2
SV1/SV2/SV3

External Connections Guide


Model Port Port description Wire number and its function
No.
1 Relay output 1 1: relay NO pin 1
2: relay COM pin
3: relay NO pin 2
2 Relay output 2 1: relay NO pin 1
2: relay COM pin
3: relay NO pin 2
3 Relay output 3 1: relay NO pin 1
2: relay COM pin
3: relay NO pin 2
4 Analog input 1 for 4-20mA interface sensor 1: V+ output
2: 4-20 mA current input
3: GND
5 Analog input 2 for 4-20mA interface sensor 1: V+ output
2: 4-20mA current input
3: GND
6 Analog input 3 for 4-20mA interface sensor 1: V+ output
SV3 2: 4-20ma current input
3: GND
7 Analog input 4 for pulse interface sensor 1: V+ output
2: pulse input
3: GND
8 Digital input 1 for Modbus via RS485 lines 1: V+ output
2: GND
3: B-
4: A+
9 / /
10 / /
11 Power output (12-24VDC @ 750 mA max) 1: 24VDC output
2: GND
12 / /
13 24VDC power supply input 1: 24VDC input
2: GND
14 Power switch /

Note: 1. Please check wire numbers carefully before making any connection to external devices. Wrong connection could lead to permanent damage.
2. Do not short circuit DC power outputs for it may cause permanent damage to this device
3. Connect your wires to those ports using suitable crimps provided in your package

3
SV1/SV2/SV3 SV1/SV2/SV3

Detailed Connection Guide

For relay ports, please note that it will automatically supply 24VDC through NO1 and NO2 wire once the corresponding relay got activated. This is custom
made relay port aimed at user friendly wiring connection support.

1.NO1 OPEN/CLOSE
Relay Water valve
2.COM GND
port motor
3.NO2 CLOSE/OPEN

Analog current ports support both 3-wire and 2-wire 4-20 mA sensors. Their respective connection diagrams are shown below.

Analog 1.V+
2-wire
current 2.4-20mA Signal +
4-20 mA sensor
port 3.GND Signal -

Analog 1.V+ VCC


3-wire
current 2.4-20mA Signal +
4-20 mA sensor
port 3.GND Signal -

Pulse sensors with 24VDC amplitude and frequency up to 10 kHz are fully supported. The connection should be made as
follows:

Digital 1.V+ VCC


Pulse
pulse 2.Pulse input Pulse output
sensor
port 3.GND GND

For sensors or devices that operate on Modbus protocol, their corresponding connection is shown below.

1.V+ VCC
Digital
2.GND GND Modbus
pulse
3.B- B- sensor
port
4.A+ A+