You are on page 1of 5

PERSPECTIVE

REPUBLIC OF THE PHILIPPINES

PROPOSED
WATER
PUMP
FOR
NIG
STAO
LASM
TLE
S
TIN
ICHOOLS
A-1
DEPARTMENT OF EDUCATION
DEPARTMENT OF EDUCATION
EDUCATION FACILITIES DIVISION
- PERSPECTIVE 2
MERALCO AVENUE, PASIG CITY
1000 4000 1300
4000

350 3300 350

700 GAL CAPACITY


WATER TANK

50MM Ø G.I PIPE


RAILING SCH. 20

2500

1"X1" TUBULAR BAR

1300

700 GAL CAPACITY 100mm THK MOLDING


WATER TANK

100mm THK x 600mm LEDGE


WATER PUMPING STATION

LEDGE
4000

LEDGE

AISLE

AISLE
4300

3000 4000
700 GAL CAPACITY
WATER TANK
AISLE

50MM Ø G.I PIPE


600 600 RAILING SCH. 20
100

600 1"X1" TUBULAR BAR

1200

100mm THK MOLDING

100mm THK x 600mm LEDGE

2 ROOFDECK FLOOR 3 FRONT ELEVATION 4300

A-1 A-1 SCALE NTS


SCALE NTS 3000

4000

100
700 GAL CAPACITY
4000
WATER TANK

50MM Ø G.I PIPE


RAILING SCH. 20

LEFT SIDE ELEVATION


450

350 1"X1" TUBULAR BAR


5
1200

STEEL STAIR
A-1 SCALE NTS
100mm THK x 600mm LEDGE

PUMP / UTILITY
4000 3300 AREA 3100 4300

3000

450

350 7000

100

600 350 3300 350 600

4 REAR ELEVATION
1 FLOOR PLAN A-1 SCALE NTS
A-1 SCALE NTS

REPUBLIC OF THE PHILIPPINES

PROPOSED
WATER
PUMP
FOR
NIG
STAO
LASM
TLE
S
TIN
ICHOOLS
A-2
DEPARTMENT OF EDUCATION
DEPARTMENT OF EDUCATION
EDUCATION FACILITIES DIVISION
-
-
FLOOR PLAN
ELEVATIONS 2
MERALCO AVENUE, PASIG CITY - SECYIONS
GENERAL NOTES AND SPECIFICATION
4000 4000

0.9000 0.9000

CL

PUMP / UTILITY PUMP / UTILITY


8.0000 6.2000 ROOM 8.0000 6.2000 ROOM

MD CL
0.9000 0.9000

1.9000 1.9000

POWER LAYOUT LIGHTING LAYOUT


FLOOR PLAN FLOOR PLAN ELECTRICAL RISER DIAGRAM

SCHEDULE OF LOADS

S ab

CL

SINGLE LINE DIAGRAM

REPUBLIC OF THE PHILIPPINES

PROPOSED
WATER
PUMP
FOR
NIG
STAO
LASM
TLE
S
TIN
ICHOOLS
E-1
- LIGHTING LAYOUT
DEPARTMENT OF EDUCATION
DEPARTMENT OF EDUCATION
EDUCATION FACILITIES DIVISION
-
-
POWER LAYOUT
LOAD COMPUTATION
1
MERALCO AVENUE, PASIG CITY - SINGLE LINE DIAGRAM
- RISER DIAGRAM
GENERAL NOTES:

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO DESIGN LEGENDS:
THE PHILIPPINE PLUMBING CODE, THE NATIONAL BUILDING CODE, AND THE RULES
AND REGULATION OF THE LOCAL GOVERNMENT AUTHORITIES CONCERNED.
GATE VALVE
D O UB
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND OL P T ST )
R C TA NE AL
PP E, LI TU
SPECIFICATIONS, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY WATER METER Ø LIN TER AC
2 mmTER WA RIFY E
3 A IN VE
DISCREPANCY FOUND HEREIN. W A T(
M U
DG
LE
O
CHECK VALVE Y
CIT
LE
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATIONS PA NK AIS
CA TA
REQUIRED FOR PROPER EXECUTIONS OF OTHER TRADES SHALL BE WITH PRIOR WATER CLOSET G ALTER
0 A
APPROVAL OF THE ARCHITECT OR ENGINEER. 70 W
LAVATORY
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, LD S
CO RE
DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS KITCHEN SINK 4.00
LE LE PR E, IXTU
AIS AISmØ RP LINTO F
VERIFIED BY THE CONTRACTOR. m E
ITY 32WAT PPLY
GREASE TRAP GE D TIL SU
LE /U A
MP RE
5. ALL SLOPES FOR HORIZONTAL DRAINAGES SHALL MAINTAIN 2% AS MINIMUM SHOWER PU A
UNLESS NOTED OTHERWISE.

1.00
HOSE BIBB
6. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE INDICATED. CLEAN OUT

0.35
32mmØ PPR COLD
7. AIR CHAMBER, ALL INDIVIDUAL BRANCHES TO FIXTURES OR GROUP OF FIXTURES FLOOR-CLEAN OUT WATER LINE, TAP TO
WATER SOURCE
AND OR EQUIPMENTS SHALL BE PROVIDED WITH AIR CHAMBER OF CAPPED
ERTICAL PIPE EXTENSION OF DIMENSIONS AS SHOWN IN THE DETAILS. FAUCET (VERIFY ACTUAL)

WATER PUMP
8. ALL SEWER LINES SHALL BE PVC SERIES 1000, “NELTEX”, “SANIMOLD EXTRA” OR WATER TANK 700 GAL CAPACITY 700 GAL CAPACITY
APPROVED EQUAL. WATER TANK WATER TANK
TOILET NO.
9. ALL VENT STACK AND VENT SHALL BE PVC PIPE SERIES 1000, “NELTEX”, ISOMETRIC

4.00

3.30
MANHOLE

LEDGE

LEDGE
“SANIMOLD” OR APPROVED EQUAL.

LEDGE

LEDGE
AISLE

AISLE

AISLE

AISLE
BUSTER PUMP 3 WATER LINE
10. ALL GALVANIZED IRON PIPES LAID UNDERGROUND AND WITH DIRECT CONTACT P 1 SCALE 1:50 MTS
WITH THE SOIL SHALL BE PROVIDED WITH THE THREE PROTECTIVE FLOAT VALVE
TAR-COVERING THEN WRAP WITH BURLAP. FOOT VALVE

11. MAIN WATER DISTRIBUTION LINE SHALL BE POLYPROPYLENE PIPE(PPR). ALL LAUNDRY DRAIN
FD FD
OTHER PIPES TO BE USED SHAL BE AS PER PLAN AND SPECIFICATIONS. BIDET SPRAY AISLE AISLE

0.35

0.47
32mmØ PPR COLD
WATER LINE,
12. ALL COLD WATER LINES SHALL BE TESTED 100 PSI FOR A PERIOD OF TWO (2) VENT THRU ROOF

0.60
SUPPLY TO FIXTURES PROVIDE DS DS PROVIDE
HOURS BEFORE COVERING. SPLASH SPLASH
TUB DRAIN 2.00 2.00 BLOCKS BLOCKS

13. ALL HOT WATER LINES SHALL BE PROPERLY INSULATED FLOOR DRAIN 4.00 0.60
E
DG
LE
14. ALL WET AREAS SHALL BE WATERPROOFED THRO-SEAL, HYGARD, OR APPROVED GUTTER DRAIN
ITY LE
EQUAL AND SHALL BE TESTED FOR TWENTY-FOUR (24) HOURS PRIOR TO FLOOR AC K
TAPPING.
CATCH BASIN 2 WATER LINE A
AP AN
L CR T
E
AIS
6 STORM DRAIN LINE
P 1 SCALE 1:50 MTS 0 G AT P 1 SCALE 1:50 MTS
DOWN SPOUT 70 W
15. ALL SEWER/WASTE SHALL BE TESTED AT 1.5M HEAD. FD
SEPTIC VAULT
16. WASTE LINES SHALL BE HYDRO-STATIC TESTED AT LEAST 100PSI PRIOR TO LE LE
WATER CISTERN AIS AIS DS
TAPPING. TY
GE ILI
SOIL STACK UT
D
LE 7 E
P / EA 0.4 ID
OV SH S
17. ALL SINKS (KITCHEN, PANTRY, ETC.) SHALL BE PROVIDED WITH CAST-IRON PUM AR PR SPLAOCK
BL
“METMA” OR STAINLESS STEEL GREASE TRAP WITH 10GPM MINIMUM CAPACITY. BATH TUB FD
IF NEEDED 0.6
0 0.6
FLEX. CONNECTOR 0

18. ALL SEWER/WASTE LINES, VENT AND WATER LINES SHALL BE PROVIDED WITH PRESSURE TANK DS
ADEQUATE STANDARD PIPE HANGER SUPPORT.
HYDROPNEUMATIC
FLOW
19. PROVIDE PIPE SLEEVES, AS NEEDED IN WALL PENETRATIONS. WATER PUMP E
ID
OV SH S
PR SPLAOCK 3"Ø PVC DOWNSPOUT
20. NO PIPE SHALL PASS THROUGH EXISTING BEAMS AND COLUMNS WATER LINE BL (WHERE IT OCCURS)
12MMØ ANCHOR BOLT
WELDED TO ANGLE
SEWER LINE (2 EACH SIDE TYP )
MATERIAL SPECIFICATIONS: STORM LINE
GREASE TRAP
SEWER AND VENT POLY VINYL CHLORIDE (PVC) PIPES SERIES 1000, “NELTEX”,
“SANIMOLD EXTRA” OR APPROVED EQUAL.
ISOMETRIC
COKE DISPENSER
7 STORM DRAIN LINE
DRAIN, WASTE & POLYVINYL CHLORIDE (PVC) PIPES SERIES 1000, AND CLASS 35 COKE DISP. DRAIN P 1 SCALE 1:50 MTS
VENT PIPE (DWV) SIMILAR TO EMERALD OR ITS APPROVED EQUAL WATER FILTER
16MMØ U-BOLT
COLD WATER LINE POLYPROPYLENE (PPR) PIPES BY "VESBO" OR APPRVED EQUAL CAP LIFTING HANDLE

TOI. HOR. SOIL PIPE


HOT WATER LINE POLYPROPYLENE (PPR) PIPES BY "VESBO" OR APPRVED EQUAL P L A N
VALVES MANUFACTURED BY "KITZ" BRAND OR APPROVED EQUAL
D
FLOOR DRAIN SQUARE STRAINER
WITH SLOT OPENING "METMA"
FLOOR DRAINS MANUFACTURED BY "METMA" BRAND OR APPROVED EQUAL M-120-G / OR APPROVED 16MMØ U-BOLT LIFTING
EQUIVALENT HANDLE WITH WASHER
D

150 X 38 X 6MM
HWL INSULATION 25mm FIBERGLASS, 65 Kg/m2 DENSITY, WITH FACTORY FLAT BAR AND NUTS 50 X 50 X 6MM FRAME
APPLIED SERVICE VAPOR BARRIER JACKET FINISH FLOOR LEVEL (ALL AROUND)
228.6 12MMØ @ 200MM
FCU INSULATION 25mm THK RUBBER INSULATION PLAN WATERPROOFING BRASS CLEAN-OUT W/ CAST PVC CLEANOUT 12Ø ANCHOR ROD
CONCRETE WELDED TO
D MEMBRANE (BY OTHERS) IRON BODY (COUNTERSUNK HEAD) PAVEMENT ANGLE (2 EACH SIDE)
DIMENSIONS WATER PROOFING
SCHEDULE
PIPE DIM. IN MM.
PVC 18 BEND
508-101.60

SIZE
IN 'A' C D EXPANSION SHIELD
50 38.10 101.60 HANGER
75 38.10 127.00 PVC 18 BEND PVC 18 BEND 4 - Ø12 GRAVEL
FLOOR 100 40.00 152.40
SECTION DRAIN
150 50.80 177.80 DETAIL OF FLOOR SAND 10MMØ HOR BARS @
200MM.0.C
BODY
CLEAN OUT DETAIL OF GROUND
FLOOR DRAIN DETAILS CLEAN OUT
GRAVEL 12MMØ VERT. BARS @
200MM.O.C

Ø10 @
10MMØ @ 200MM
200MM
S E C T I O N
1 MISCELLANEOUS DETAILS
P 1 SCALE NTS. CATCH BASIN DETAILS

REPUBLIC OF THE PHILIPPINES

PROPOSED
WATER
PUMP
FOR
NIG
STAO
LASM
TLE
S
TIN
ICHOOLS
P-1
DEPARTMENT OF EDUCATION
DEPARTMENT OF EDUCATION
EDUCATION FACILITIES DIVISION
-
-
-
DRAINAGE LAYOUT
WATER DISTRIBUTION LAYOUT
ISOMETRIC VIEW
1
MERALCO AVENUE, PASIG CITY - PLUMBING STANDARD DETAILS
1 2
4000

S C H E D U L E OF S L A B S
A

SECOND
LEVEL
4000

B
L1 L2 L3

L2/3 L2/3 L3/3 L3/3

2D 2D LAP SPLICES ARE ALLOWED 2D 2D LAP SPLICES ARE ALLOWED 2D


ONLY IN THIS PORTION ONLY IN THIS PORTION

FOUNDATION PLAN

D
L2/5 L2/5 L2/5 L3/6
2-Ø12mm SIDE BARS

1 2
TYPICAL BEAM ELEVATION
4000

4000

BEAM LAYOUT

350

TYP. FOOTING DETAIL


350

SCHEDULE OF FOOTING

REPUBLIC OF THE PHILIPPINES

PROPOSED
WATER
PUMP
FOR
NIG
STAO
LASM
TLE
S
TIN
ICHOOLS
S-1
DEPARTMENT OF EDUCATION
DEPARTMENT OF EDUCATION
EDUCATION FACILITIES DIVISION
-
-
-
FOUNDATION PLAN
COLUMN AND BEAM DETAILS
SLAB DETAIL
1
MERALCO AVENUE, PASIG CITY - FOOTING DETAIL

You might also like