Professional Documents
Culture Documents
Version 3 / 2003
Icosit® ZP Primer
Primer for aluminium and steel decks for SikaTransfloor®-352
levelling compound
Icosit® ZP Primer 1 / 1
Method of Application Important Note Note
Surface preparation Discard any primer that has gelled. The information, and, in particular, the
Clean the sanded surface recommendations relating to the
®
thoroughly with Sika Cleaner-205. application and end-use of Sika
Further Information products, are given in good faith based
Leave it to dry for at least 10 Copies of the following publications on Sika's current knowledge and
minute. Avoid dust or other are available on request: experience of the products when
contamination until the next step - Material Safety Data Sheets properly stored, handled and applied
has been carried out. - TDS SikaTransfloor®-352 under normal conditions. In practice,
- Marine Application Guide the differences in materials, substrates
Primer preparation and actual site conditions are such that
Mix up first component A then add no warranty in respect of
component B and mix the Packaging Information merchantability or of fitness for a
components thoroughly with an 3,0 kg particular purpose, nor any liability
Can (A+B) arising out of any legal relationship
electric mixer. Transfer the mixture 12,5 kg
completely to a clean container whatsoever, can be inferred either from
and mix for an other minute. this information, or from any written
Important recommendations, or from any other
Reseal container tightly immedia- For information and advice re- advice offered. The proprietary rights of
tely after use. Observe pot life. The garding transportation, handling, third parties must be observed. All
primer is applied by brush or roller. storage and disposal of chemical orders are accepted subject to our
If needed Sika® Thinner EG may products, users should refer to the current terms of sale and delivery.
be added in max. 5% of the actual Material Safety Data Sheets Users should always refer to the most
mixture. recent issue of the Technical Data
containing physical, ecological, Sheet for the product concerned,
toxicological and other safety- copies of which will be supplied on
related data. request.
Sika Schweiz AG
Industry
Tueffenwies 16
CH-8048 Zurich
Switzerland
Tel. +41 1 436 40 40
Fax +41 1 436 45 30