Engineering Report Structural Calculation PROPOSED THREE STOREY OFFICE BUILDING

DESIGN OF TWO-WAY SLAB m


Coefficients for nega

Slab Design S-1 ###


###
DESIGN PARAMETERS ###
f'c = 20 MPa Compressive strength of concrete ###
fy = 227 MPa Yield strength of steel bar ###
Ø= 10 mm Bar diameter ###
t= 100 mm Thickness of slab ###
L= 3.20 m Longer dimension of slab ###
B= 2.50 m Shorter dimension of slab ###
###
smax = 300 Maximum spacing of reinforcement ###
b= 1000 Width of slab ###
d= 75 Effective depth of slab
Coefficients for DL
SUPPORT CONDITIONS
m
CASE 1 CASE 2 CASE 3 CASE 4 CASE 5 CASE 6 CASE 7 CASE 8 CASE 9 ###
###
###
###
DESIGN LOADS If m > 0.5 is Two Way Slab ###
Live Load = 2.40 KPa Ratio(B/L) = 0.78 ###
Ceiling = 0.20 KPa m = 0.60 < < Manual Input !!! ###
Utilities = 0.10 KPa ###
Topping = 0.60 KPa ###
Flr Fin = 0.77 KPa ###
Mov. Part = 0.50 KPa ###
Others = 0.00 KPa ###
Slab = 2.40 KPa
Total DL = 4.57 KPa Coefficients for LL p

m
MOMENT COEFFICIENTS ###
-CaDL = 0.089 Negative moment coefficient along the shorter dimension due to dead load ###
-CaLL = 0.089 Negative moment coefficient along the shorter dimension due to live load ###
-CbDL = 0.011 Negative moment coefficient along the longer dimension due to dead load ###
-CbLL = 0.011 Negative moment coefficient along the longer dimension due to live load ###
+CaDL = 0.053 Positive moment coefficient along the shorter dimension due to dead load ###
+CaLL = 0.080 Positive moment coefficient along the shorter dimension due to live load ###
+CbDL = 0.007 Positive moment coefficient along the longer dimension due to dead load ###
+CbLL = 0.009 Positive moment coefficient along the longer dimension due to live load ###
###
###
LOCATION EQUATIONS MOMENT MTOTAL rreqd rused Spacing Sfinal Ductility Rebar spacing, mm
Negative -CaDLWuDLLa2 3.05
5.19 0.00466 0.0062 170 170 PASS 10 mm diameter @ 150 mm
Moment, Ma -C W L 2 2.14
aLL uLL a

Negative -CbDLWuDLLb2 0.62


1.05 0.000920 0.0012 856 300 PASS 10 mm diameter @ 300 mm
Moment, Mb -C W L 2 0.43
bLL uLL b

Positive Moment, +CaDLWuDLLa


2
1.82
3.74 0.003325 0.0044 237 237 PASS 10 mm diameter @ 200 mm
Ma +CaLLWuLLLa2 1.92
Positive Moment, +CbDLWuDLLb
2
0.39
0.75 0.000653 0.0009 1206 300 PASS 10 mm diameter @ 300 mm
Mb +CbLLWuLLLb2 0.35
0.00956
CASE = 4 See support conditions

150 mm 150 mm

Along La (short Span) t

200 mm

300 mm 300 mm

Along Lb (long Span) t

300 mm
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

DESIGN OF TWO-WAY SLAB m


Coefficients for nega

Slab Design S-1 ###


###
DESIGN PARAMETERS ###
f'c = 20.00 MPa Compressive strength of concrete ###
fy = 227.00 MPa Yield strength of steel bar ###
Ø= 10.00 mm Bar diameter ###
t= 100.00 mm Thickness of slab ###
L= 3.20 m Longer dimension of slab ###
B= 2.50 m Shorter dimension of slab ###
###
smax = 300 Maximum spacing of reinforcement ###
b= 1000 Width of slab ###
d= 75 Effective depth of slab
Coefficients for DL
SUPPORT CONDITIONS
m
CASE 1 CASE 2 CASE 3 CASE 4 CASE 5 CASE 6 CASE 7 CASE 8 CASE 9 ###
###
###
###
DESIGN LOADS If m > 0.5 is Two Way Slab ###
Live Load = 1.90 KPa Ratio(B/L) = 0.78 ###
Ceiling = 0.20 KPa m = 0.60 < < Manual Input !!! ###
Utilities = 0.10 KPa ###
Topping = 0.60 KPa ###
Flr Fin = 0.77 KPa ###
Mov. Part = 0.50 KPa ###
Others = 0.00 KPa ###
Slab = 2.40 KPa
Total DL = 4.57 KPa Coefficients for LL p

m
MOMENT COEFFICIENTS ###
-CaDL = 0.080 Negative moment coefficient along the shorter dimension due to dead load ###
-CaLL = 0.080 Negative moment coefficient along the shorter dimension due to live load ###
-CbDL = 0.018 Negative moment coefficient along the longer dimension due to dead load ###
-CbLL = 0.018 Negative moment coefficient along the longer dimension due to live load ###
+CaDL = 0.048 Positive moment coefficient along the shorter dimension due to dead load ###
+CaLL = 0.065 Positive moment coefficient along the shorter dimension due to live load ###
+CbDL = 0.007 Positive moment coefficient along the longer dimension due to dead load ###
+CbLL = 0.009 Positive moment coefficient along the longer dimension due to live load ###
###
###
LOCATION EQUATIONS MOMENT MTOTAL rreqd rused Spacing Sfinal Ductility Rebar spacing, mm
Negative -CaDLWuDLLa2 2.74
4.26 0.00381 0.0051 207 207 PASS 10 mm diameter @ 200 mm
Moment, Ma -C W L 2 1.52
aLL uLL a

Negative -CbDLWuDLLb2 1.01


1.57 0.001380 0.0018 571 300 PASS 10 mm diameter @ 300 mm
Moment, Mb -C W L 2 0.56
bLL uLL b

Positive Moment, +CaDLWuDLLa


2
1.65
2.88 0.002550 0.0034 309 300 PASS 10 mm diameter @ 300 mm
Ma +CaLLWuLLLa2 1.23
Positive Moment, +CbDLWuDLLb
2
0.39
0.67 0.000588 0.0008 1339 300 PASS 10 mm diameter @ 300 mm
Mb +CbLLWuLLLb2 0.28

CASE = 8 See support conditions

200 mm 200 mm

Along La (short Span) t

300 mm

300 mm 300 mm

Along Lb (long Span) t

300 mm
Engineering Report Structural Calculation PROPOSED FOUR STOREY W/ ROOFDECK RESIDENTIAL BUILDING

DESIGN OF TWO-WAY SLAB m


Coefficients for nega

Slab Design S-1 ###


###
DESIGN PARAMETERS ###
f'c = 20.00 MPa Compressive strength of concrete ###
fy = 227.00 MPa Yield strength of steel bar ###
Ø= 10.00 mm Bar diameter ###
t= 100.00 mm Thickness of slab ###
L= 3.20 m Longer dimension of slab ###
B= 2.50 m Shorter dimension of slab ###
###
smax = 300 Maximum spacing of reinforcement ###
b= 1000 Width of slab ###
d= 75 Effective depth of slab
Coefficients for DL
SUPPORT CONDITIONS
m
CASE 1 CASE 2 CASE 3 CASE 4 CASE 5 CASE 6 CASE 7 CASE 8 CASE 9 ###
###
###
###
DESIGN LOADS If m > 0.5 is Two Way Slab ###
Live Load = 1.90 KPa Ratio(B/L) = 0.78 ###
Ceiling = 0.20 KPa m = 0.60 < < Manual Input !!! ###
Utilities = 0.10 KPa ###
Topping = 0.60 KPa ###
Flr Fin = 0.77 KPa ###
Mov. Part = 0.50 KPa ###
Others = 0.00 KPa ###
Slab = 2.40 KPa
Total DL = 4.57 KPa Coefficients for LL p

m
MOMENT COEFFICIENTS ###
-CaDL = 0.089 Negative moment coefficient along the shorter dimension due to dead load ###
-CaLL = 0.089 Negative moment coefficient along the shorter dimension due to live load ###
-CbDL = 0.011 Negative moment coefficient along the longer dimension due to dead load ###
-CbLL = 0.011 Negative moment coefficient along the longer dimension due to live load ###
+CaDL = 0.053 Positive moment coefficient along the shorter dimension due to dead load ###
+CaLL = 0.080 Positive moment coefficient along the shorter dimension due to live load ###
+CbDL = 0.007 Positive moment coefficient along the longer dimension due to dead load ###
+CbLL = 0.009 Positive moment coefficient along the longer dimension due to live load ###
###
###
LOCATION EQUATIONS MOMENT MTOTAL rreqd rused Spacing Sfinal Ductility Rebar spacing, mm
Negative -CaDLWuDLLa2 3.05
4.74 0.00425 0.0056 185 185 PASS 10 mm diameter @ 150 mm
Moment, Ma -C W L 2 1.69
aLL uLL a

Negative -CbDLWuDLLb2 0.62


0.96 0.000840 0.0011 937 300 PASS 10 mm diameter @ 300 mm
Moment, Mb -C W L 2 0.34
bLL uLL b

Positive Moment, +CaDLWuDLLa


2
1.82
3.34 0.002962 0.0039 266 266 PASS 10 mm diameter @ 250 mm
Ma +CaLLWuLLLa2 1.52
Positive Moment, +CbDLWuDLLb
2
0.39
0.67 0.000588 0.0008 1339 300 PASS 10 mm diameter @ 300 mm
Mb +CbLLWuLLLb2 0.28

CASE = 4 See support conditions

150 mm 150 mm

Along La (short Span) t

250 mm

300 mm 300 mm

Along Lb (long Span) t

300 mm
Engineering Report Structural Calculation PROPOSED TWO STOREY RESIDENTIAL BUILDING

DESIGN OF TWO-WAY SLAB m


Coefficients for nega

Slab Design S-1 ###


###
DESIGN PARAMETERS ###
f'c = 20.00 MPa Compressive strength of concrete ###
fy = 227.00 MPa Yield strength of steel bar ###
Ø= 10.00 mm Bar diameter ###
t= 100.00 mm Thickness of slab ###
L= 3.20 m Longer dimension of slab ###
B= 2.50 m Shorter dimension of slab ###
###
smax = 300 Maximum spacing of reinforcement ###
b= 1000 Width of slab ###
d= 75 Effective depth of slab
Coefficients for DL
SUPPORT CONDITIONS
m
CASE 1 CASE 2 CASE 3 CASE 4 CASE 5 CASE 6 CASE 7 CASE 8 CASE 9 ###
###
###
###
DESIGN LOADS If m > 0.5 is Two Way Slab ###
Live Load = 1.90 KPa Ratio(B/L) = 0.78 ###
Ceiling = 0.20 KPa m = 0.60 < < Manual Input !!! ###
Utilities = 0.10 KPa ###
Topping = 0.77 KPa ###
Flr Fin = KPa ###
Mov. Part = 0.50 KPa ###
Others = 0.00 KPa ###
Slab = 2.40 KPa
Total DL = 3.97 KPa Coefficients for LL p

m
MOMENT COEFFICIENTS ###
-CaDL = 0.081 Negative moment coefficient along the shorter dimension due to dead load ###
-CaLL = 0.081 Negative moment coefficient along the shorter dimension due to live load ###
-CbDL = 0.010 Negative moment coefficient along the longer dimension due to dead load ###
-CbLL = 0.010 Negative moment coefficient along the longer dimension due to live load ###
+CaDL = 0.034 Positive moment coefficient along the shorter dimension due to dead load ###
+CaLL = 0.058 Positive moment coefficient along the shorter dimension due to live load ###
+CbDL = 0.004 Positive moment coefficient along the longer dimension due to dead load ###
+CbLL = 0.007 Positive moment coefficient along the longer dimension due to live load ###
###
###
LOCATION EQUATIONS MOMENT MTOTAL rreqd rused Spacing Sfinal Ductility Rebar spacing, mm
Negative -CaDLWuDLLa2 2.41
3.95 0.00352 0.0047 224 224 PASS 10 mm diameter @ 200 mm
Moment, Ma -C W L 2 1.54
aLL uLL a

Negative -CbDLWuDLLb2 0.49


0.80 0.000699 0.0009 1127 300 PASS 10 mm diameter @ 300 mm
Moment, Mb -C W L 2 0.31
bLL uLL b

Positive Moment, +CaDLWuDLLa


2
1.01
2.11 0.001863 0.0025 423 300 PASS 10 mm diameter @ 300 mm
Ma +CaLLWuLLLa2 1.10
Positive Moment, +CbDLWuDLLb
2
0.20
0.41 0.000360 0.0005 2185 300 PASS 10 mm diameter @ 300 mm
Mb +CbLLWuLLLb2 0.22

CASE = 2 See support conditions

200 mm 200 mm

Along La (short Span) t

300 mm

300 mm 300 mm

Along Lb (long Span) t

300 mm